Tender Value
₹1.3 Cr
EMD Value
₹2.2 L
Closing Date
13 Apr 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TENDER
17 conditions · 6 needing a document upload
Tenderer should submit their bank account no., name of the bank and bank specific code no. in separate sheet, Current valid GST registration no. and PAN CARD.
Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' shall be exempted from payment of Bid Security detailed above. 2. Labour Cooperative Societies shall submit only 50% of above Bid Security detailed above
The tenderer are advised to submit the Bid Security with the tender for the due performance with the stipulation to keep the offer open till such date as specified in the tender, under the conditions of tender. The Bid Security shall be deposited either in cash through e payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure-VIA and shall be valid for a period of 90days. beyond the bid validity period.
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V=Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. [As per GCC April 2022 Advance Correction Slip No. 1]
Tenderer should have valid electrical contractor license issued by Government Electrical License Board on or before closing date of tender, copy of which should be submitted along with the tender offer, otherwise tender would be summarily rejected.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfilment of technical eligibility criteria for different components. similar nature of work (Supply, installation, testing and commissioning of any LT/HT electrical work".)
31 conditions · 8 needing a document upload
Whether the bank account no., name of the bank and bank specific code no. in separate sheet submitted
Whether PAN Card details submitted in separate sheet.
Whether GSTIN number along with other necessary documents under GST Act (which is implemented w.e.f 01- 07- 17) submitted in separate sheet.
Whether document relevant to 1)Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' certificate submitted in case of exemption from payment of earnest money deposit. 2) Labour Cooperative Societies certificate submitted in case of deposition of only 50% of Bid Security
Whether Document verification certificate Annexure V(A) is submitted as the case may be.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
A)At NMB :Electrical works for construction of kitchen, waiting lounge, dining room, caretaker room and other ancillary works for newly proposed officer's rest house at Nambari, Maligaon. B)At NMB : Electrical work in connection with development works, boundary wall, water tank along with pipe line network for construction of New Officer's rest house at Nambari officer colony. C)At NMB : Electrical works for construction of G+1 Sub-Ordinate Rest House at Maligaon. D) At NMB : Electrical works for construction of Multi storied Officer's rest house at Nambari (Phase-I) E) At NMB : Electrical works for construction of 1st floor building at officer's rest house at Nambari, Maligaon
DYCEE-PS-MLG-HQ-64-25-26
DYCEE-PS-MLG-HQ-64-25-26
Open
Works - General
180 Days
Kamrup, Assam
₹0
₹2.2 L
13 Apr 2026
21 Mar 2026
30 Mar 2026
100 items across 4 schedules · ₹62,41,317 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply, wiring of concealed light point by PVC insulated unsheathed and multi-stranded FRLS Copper Cable 1.5 sq.mm S/C confirming to IS - 694 through suitable size (19 mm) of PVC Concealed rigid Conduit pipe of wall thickness 2mm including 10AX One-way modular switch on 1/2 M concealed unbreakable GI modular box, 2 M cover plate etc. with all accessories and ceiling rose /holder etc. as required. | Numbers | 100.00 | 386 | 38,600 |
| 2 | Supply, wiring of concealed ceiling fan point by PVC insulated unsheathed and multi stranded FRLS Copper Cable 1.5 sq.mm S/C confirming to IS - 694 through suitable size (19 mm) of PVC Concealed rigid Conduit pipe of wall thickness 2mm and ceiling rose, wire as required and 10 AX one-way modular switch, 4 step energy saving electronic BLDC fan compatible regulator on 1/2 M concealed unbreakable GI modular box, 2 M cover plate etc. with 1sq. mm unsheathed copper cable as earth continuity wire with all accessories and ceiling rose etc. as required. | Numbers | 20.00 | 785 | 15,700 |
| 3 | Supply, fixing, testing and commissioning of super energy efficient BLDC electric ceiling fan of 32W having BEE five star rating, 1400mm sweep, 230V AC 50HZ, speed 320 RPM with compatible remote control including fixing arrangement by allied engineering works. | Numbers | 12.00 | 2,840 | 34,080 |
| 4 | Supply, fitting, fixing and testing of indoor surface mounting 1x18/20 watts (4ft.) LED batten tube light fitting complete with lamp and other accessories along with connection of flexible copper cable etc. as per direction of site engineer in-charge. Lumens output should be greater than 100 Lumens/watt. LED driver's efficiency should be minimum 90% .Power factor of complete fitting should be greater than 0.90, Input operating voltage: 140V to 277V AC. | Numbers | 20.00 | 344 | 6,880 |
| 5 | Supply, installation, testing and commissioning of 15W Round LED Panel Light fitting suitable for recessed mounting complete with having LED driver, connectors, wiring, and all required accessories. Supply, fitting, fixing, testing and commissioning of recess mounting pressure die cast 15watts deep recessed anti-glare LED r o u n d d o w n light fitting complete with lamp having separate replaceable electronic driver including flexible connecting cable, ceiling rose etc. as per site requirement and as per direction of site engineer in-charge. LED driver's efficiency should be minimum 90%, Power factor of complete fitting should be greater than 0.90, Input operating voltage: 140V to 277V AC. | Numbers | 44.00 | 575 | 25,300 |
| 6 | Supply, fitting, fixing and testing of indoor 2x5Watt watts LED wall mounting decorative light fitting having chrome finish with opal glass complete with lamp and other accessories along with connection of flexible copper cable etc. as per direction of site engineer in-charge. | Numbers | 12.00 | 1,801 | 21,612 |
| 7 | Supply, installation, testing and commissioning of continuous LED profile strip lighting system of 45/50 Watt per metre, complete with extruded aluminium profile housing with opal/diffuser cover, high efficiency LED strip with minimum efficacy of 100 lm/W, suitable constant voltage LED driver of reputed make, required connectors, end caps, mounting accessories, and fixing arrangements. The work shall include cutting, bending, recess/surface mounting as required, interconnection, termination, and integration with existing electrical system, complete in all respects as per directed by the Engineer-in-Charge | Metre | 100.00 | 365 | 36,500 |
| 8 | Supply, erection and commissioning of wall mounted bracket fan 400mm sweep suitable for single phase 230 volt AC supply including fixing arrangement by allied engineering works. | Numbers | 10.00 | 2,037 | 20,370 |
| 9 | Supply, wiring of concealed 6 Amps plug socket point with 2.5 sq mm S/C PVC insulated unsheathed and multi-stranded FRLS Copper Cable through suitable size (19mm) of PVC Concealed rigid Conduit pipe of wall thickness 2mm of suitable size with 10AX one-way modular switch and 6Amp 5 pin shuttered socket on 3 M concealed unbreakable GI modular box, 3 M cover plate etc. with 1 sq. mm unsheathed copper cable as earth continuity wire. | Numbers | 60.00 | 508 | 30,480 |
| 10 | Supply, wiring of concealed 16 Amps plug socket point with 4 sq mm S/C PVC insulated unsheathed and multi-stranded FRLS Copper Cable through suitable size (19mm) of PVC Concealed rigid Conduit pipe of wall thickness 2mm of suitable size with 16AX One-way modular switch on 3 M concealed unbreakable GI modular box, 3M cover plate etc. with 1 sq. mm unsheathed copper cable as earth continuity wire. | Numbers | 48.00 | 644 | 30,912 |
| 11 | Supply, Wiring of concealed exhaust/wall bracket fan point by PVC insulated unsheathed and multi stranded FRLS Copper Cable 1.5sq.mm S/C confirming to IS - 694/1990 through suitable size (19 mm) of PVC Concealed rigid Conduit pipe of wall thickness 2mm including ceiling rose and 10 AX one way modular switch in 1/2 M concealed unbreakable GI modular box, 2 M cover plate etc. with 1sq. mm unsheathed copper cable as earth continuity wire. | Numbers | 20.00 | 419 | 8,380 |
| 12 | Supply, erection, testing and commissioning of ventilator type DX exhaust fan 250 mm sweep suitable for single phase 230 volt AC supply including fixing arrangement by allied engineering works. | Numbers | 4.00 | 1,639 | 6,556 |
| 13 | Supply, installation, testing and commissioning of High speed Industrial type Exhaust fan 380/450mm suitable for single phase 230 volt AC supply including fixing arrangement by allied engineering works. | Numbers | 6.00 | 3,400 | 20,400 |
| 14 | Supply & wiring of water heater (geyser) point through suitable size (19mm) of PVC Concealed rigid Conduit pipe by 2x4 sq.mm PVC insulated unsheathed and multi-stranded FRLS copper cable duly fitted on wall complete with 1 no. 16 AX One-way modular switch, 6-16 A 3 pin shuttered socket with 1/2M concealed unbreakable GI modular box, 2 M cover plate etc. as required at site as per direction of site Engineer. | Numbers | 2.00 | 707 | 1,414 |
| 15 | Supply & wiring of RAC point through suitable size (19mm) of PVC Concealed rigid Conduit pipe by 2x 4 sq.mm PVC insulated unsheathed and multi-stranded FRLS copper cable on wall complete with 1 No. 25 A motor starter switch, 1 No. 32A SP mini MCB, C-series, 3kA, 6-16 A 3 pin shuttered socket with 3M concealed unbreakable GI modular box, 3 M cover plate etc. as required at site including 1sq. mm unsheathed copper cable as earth continuity wire. | Numbers | 6.00 | 1,111 | 6,666 |
| 16 | Supply, Installation, Testing & Commissioning of 1.5 TR inverter type (Variable speed) split air conditioner having eco-friendly non-CFC refrigerant (R-32), latest BEE 5 star rated, Copper coil confirming IS: 1391, with rotary compressor, suitable for 230V, 50 Hz AC supply, including MS base frame for outdoor unit, connecting the unit to refrigerant piping. drain pipe, power cabling & control cabling complete. | Numbers | 6.00 | 48,938 | 2,93,628 |
| 17 | Supply, fitting, fixing and testing of 3 KW, 3 Litres capacity 5 star rated Instant Water Heater (geyser), with Colour-Changing LED Indicator, as per direction of site engineer in-charge of railway. | Numbers | 2.00 | 5,060 | 10,120 |
| 18 | Supply, installation, testing and commissioning of indoor type, grey colour12 way SPN Distribution Board Double (Metal) door having 1 No. 63 amps., B/C series, 4PMCB , 08 Nos. 20 amps SP B/C curve MCB including internal connection of suitable copper cable / strip to be provided as per direction of site Engineer in charge of Railway. | Set | 4.00 | 8,176 | 32,704 |
| 19 | Supply , testing and erection of indoor type, white colour 8 way V- TPN Distribution Board Single door having 1 No. 125 Amps 4P 27 KA thermal magnetic released MCCB and 24 Nos. 40 Amps SP B/C-curve, 10kA MCB including internal connection of suitable copper cable / strip to be provided as per direction of site Engineer incharge of Railway. | Set | 2.00 | 43,441 | 86,882 |
| 20 | Supply and wiring of sub- main line concealed by 2x2.5 sq. mm. PVC insulated unsheathed and multi stranded FRLS Copper Cable confirming to IS 694/1990 through suitable size of PVC conduit pipe with 1sq. mm unsheathed copper cable as earth continuity wire. | RM | 1200.00 | 83 | 99,600 |
| 21 | Supply and wiring of sub- main line concealed by 2x4 sq. mm. PVC insulated unsheathed and multi stranded FRLS Copper Cable confirming to IS 694/1990 through suitable size of PVC conduit pipe with 1sq. mm unsheathed copper cable as earth continuity wire. | RM | 600.00 | 102 | 61,200 |
| 22 | Supply and wiring of sub- main line concealed by 2x6 sq. mm. PVC insulated unsheathed and multi stranded FRLS Copper Cable confirming to IS 694/1990 through suitable size of PVC conduit pipe with 1sq. mm unsheathed copper cable as earth continuity wire. | RM | 300.00 | 132 | 39,600 |
| 23 | Supply and wiring of sub- main line concealed by 2x10 sq. mm. PVC insulated unsheathed and multi stranded FRLS Copper Cable confirming to IS 694/1990 through suitable size of PVC conduit pipe with 1sq. mm unsheathed copper cable as earth continuity wire. | RM | 300.00 | 180 | 54,000 |
| 24 | Supply, erection of earthing set by 80 mm Dia GI pipe 4 Mts. long including construction of earth pit with cover and earth continuity by (25x3)mm GI strip , GI nuts and bolts etc. as per direction at site Engineer. | Numbers | 6.00 | 3,323 | 19,938 |
| 25 | Supply, testing & commissioning of 40x6 mm size GI strip for earth mat as per direction of engineer in-charge of the site. | Metre | 200.00 | 111 | 22,200 |
| 26 | Supply and installation of 8 KG capacity top loading 5 star rated automatic washing machine as per instruction of site Engineer in-charge of Railway. | Numbers | 2.00 | 18,014 | 36,028 |
| 27 | Supply, fitting, fixing and testing of wall mounted plastic body fully automatic Electric hand drier machine having auto cutoff facility suitable for single phase 230 volt AC supply including flexible connecting cable as per direction of site Engineer in-charge of Railway | Numbers | 2.00 | 3,115 | 6,230 |
| 28 | OUT DOOR UNITS (20 HP) : Supply of variable refrigerant flow (VRF) system, suitable to operate between -15° C t o 49°C ambient temperature, complying with the following technical specifications. Combination of Variable Temperature &Capacity Control, Variable Inverter compressors suitable for operation on 440V (+/-)10%, 3 phase,50Hz A.C. supply for outdoor unit, fully charged with refrigerant R410A to outdoor unit and all running refrigerant pipe. It shall include anti vibration isolator pad for outdoor units, high/low pressure cut-outs, oil pressure failure switch, fan motor, safety thermostat, over current relay, fusible plugs, fuses etc. The unit shall be complete in all respect as per site requirement. The unit shall have matching air cooled condenser with copper tubes and aluminium fins duly covered by anti- corrosion and hydrophilic resin film, Oil separator suitable for the long refrigerant piping. Lot- Accumulator, liquid and gas shut-off valves and solenoid valves/modulation valve with fittings to interconnect compressor, condenser and evaporator coils | Numbers | 1.00 | 4,16,234 | 4,16,234 |
| 29 | OUT DOOR UNITS (16HP) : Supply of variable refrigerant flow (VRF) system, suitable to operate between -15° C t o 49°C ambient temperature, complying with the following technical specifications. Combination of Variable Temperature &Capacity Control, Variable Inverter compressors suitable for operation on 440V (+/-)10%, 3 phase,50Hz A.C. supply for outdoor unit, fully charged with refrigerant R410A to outdoor unit and all running refrigerant pipe. It shall include anti vibration isolator pad for outdoor units, high/low pressure cut-outs, oil pressure failure switch, fan motor, safety thermostat, over current relay, fusible plugs, fuses etc. The unit shall be complete in all respect as per site requirement. The unit shall have matching air cooled condenser with copper tubes and aluminium fins duly covered by anti- corrosion and hydrophilic resin film, Oil separator suitable for the long refrigerant piping. Lot- Accumulator, liquid and gas shut-off valves and solenoid valves/modulation valve with fittings to interconnect compressor, condenser and evaporator coils | Numbers | 1.00 | 3,52,298 | 3,52,298 |
| 30 | Supply of Indoor units with capacity 2.5 HP Ceiling Suspended 1/2 Way Cassette Type Indoor Unit with following Specification: i) IDU Power supply -AC 1ph, 230V/50Hz., ii) Nominal Cooling [Capacity - 7.1/KW, iii) Nominal Heating [Capacity - 8.5/KW, iv) Maximum Sound Pressure Level - 42 db, V) Maximum Air Flow Rate 953 CFM with Multi speed motor, coil section with DX coil. The Indoor Unit should be fire retardant, i.e. the electronic PCB of the Indoor unit should be enclosed in sheet metal box, by which fire will not spread in case of fire. | Numbers | 8.00 | 30,433 | 2,43,464 |
| 31 | Supply of Concealed type 4.0 HP Cassette Indoor Unit with fittings. Consisting of fan, Four speed motor, coil section with DX coil, outer cabinet, filter, insulated drain pan, including all accessories. Cable from indoor unit to socket and headers etc. which shall be supplied by the OEM of VRF system. complete as required. All indoor unit shall have noise level less than 48db.For critical applications requiring noise level below this limits. All indoor unit should have force shut option to connect fire alarm adopter so that the unit can be integrated with other system to stop automatically in case of such type of fire. Indoor unit shall include hanging arrangement of the unit with necessary supporting rod, nut & bolts, fastners and accessories for complete installation of Indoor unit as per site requirement. | Numbers | 2.00 | 38,671 | 77,342 |
| 32 | Supply of Concealed type 5.0HP Cassette Indoor Unit with fittings. Consisting of fan, Four speed motor, coil section with DXcoil, outer cabinet, filter, insulated drain pan, including all accessories. Cable from indoor unit to socket and headers etc. Which shall be supplied by the OEM of VRF system complete as required. All indoor unit shall have noise level less than 48db. For critical applications requiring noise level below this limits. All indoor unit should have force shut option to connect fire alarm adopter so that the unit can be integrated with other system to stop automatically in case of such type of fire. Indoor unit shall include hanging arrangement of the unit with necessary supporting rod, nut & bolts, fastners and accessories for complete installation of Indoor unit as per site requirement. | Numbers | 2.00 | 40,369 | 80,738 |
| 33 | Supply, installation and commissioning of Wired Remote for ductable type Indoor units to control of temperature inside the room as required. | Numbers | 8.00 | 1,258 | 10,064 |
| 34 | Supply of Y-Joints/T-Joints/ Ref- net separation refrigeration pipe joints and header shall be in the appropriate orientation to enable correct distribution of refrigerant for IDU as per requirement at site. | Numbers | 8.00 | 4,159 | 33,272 |
| 35 | Lifting, Shifting, Installation, testing and commissioning of Top Discharge Type Outdoor units equipped with highly efficient scroll compressors in "Variable Refrigerant Flow System" for 20 HP as per site requirement. | Numbers | 1.00 | 40,576 | 40,576 |
| 36 | Lifting, Shifting, Installation, testing and commissioning of Top Discharge Type Outdoor units equipped with highly efficient scroll compressors in "Variable Refrigerant Flow System" for 16 HP as per site requirement. | Numbers | 1.00 | 30,432 | 30,432 |
| 37 | Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with (19mm/13mmthick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor &outdoor units as per requirement at site. | RM | 37.00 | 1,983 | 73,371 |
| 38 | Supply and fixing of heavy duty rigid 32mm dia PVC piping complete with fittings, supports as per AC unit manufacture'r STD. & specifications and duly insulated with 6mm thick closed cell nitrile rubber insulation as required at site & as relevant IS. | RM | 50.00 | 160 | 8,000 |
| 39 | Supply and fixing of heavy duty rigid 25mm dia PVC piping complete with fittings, supports as per AC unit manufacture'r STD. & specifications and duly insulated with 6mm thick closed cell nitrile rubber insulation as required at site & as relevant IS. | RM | 110.00 | 137 | 15,070 |
| 40 | Supply, laying, wiring and commissioning of 2Core 1.5sqmm PVC insulated Shielded Screened and multi-stranded FRLS Copper Cable confirming to IS 694/1990 suitable size of PVC conduit pipe as per direction by site engineer in- charge. | RM | 70.00 | 160 | 11,200 |
| 41 | Supply, laying, wiring and commissioning of sub- main line by 4Core 16sqmm PVC insulated unsheathed and multi-stranded FRLS Copper Cable confirming to IS 694/1990 suitable size of PVC conduit pipe as per direction by site engineer in-charge. | RM | 50.00 | 931 | 46,550 |
| 42 | Supply, laying, wiring and commissioning of sub- main line by 4Core 2.5sqmm PVC insulated unsheathed and multi-stranded FRLS Copper Cable confirming to IS 694/1990 suitable size of PVC conduit pipe as per direction by site engineer in-charge. | RM | 72.00 | 220 | 15,840 |
| 43 | Supply and installation of following sizes of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm . | Metre | 37.00 | 1,468 | 54,316 |
| 44 | Supply, installation, testing and commissioning of indoor type (IP-44 and above), grey colour 4 way V-TPN Distribution Board Double (Metal) door having 1 No. 125 amps., Thermal magnetic release 4P MCCB, 02 Nos. 63Amps, 3P, 10KA, B/C-curve MCB including internal connection of suitable copper cable / strip to be provided as per direction of site Engineer in-charge of Railway. | Set | 1.00 | 31,822 | 31,822 |
| 45 | Supply & Installation of condenser outdoor frame structure made up of MSC-Channel including necessary C/C foundation as per requirement at site. | Numbers | 2.00 | 9,758 | 19,516 |
| 46 | Supply of Refrigerant Gas of R410A charge to outdoor unit and connected pipes between outdoor unit and AHU as per site requirement. | Kg | 30.00 | 1,116 | 33,480 |
| 47 | Supply & providing drop ceiling to cover the indoor units & supply air duct, with 3mm thick ACP sheet as per manufacturer's specification on the frame work fabricated from Aluminum hollow rectangular section of size 50mm x 25mm (2mm thick) & duly suspended by Aluminum hollow rectangular section of size 50mm x 38mm (2mm thick) and silicon sealant complete in all respect as per direction of EIC. | Sqm | 20.00 | 2,793 | 55,860 |
| Schedule total | ₹27,15,425 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
annexure
ATTACHMENT
GCC-2022.pdf
ATTACHMENT
correctionslip1to11compressed.pdf
ATTACHMENT
64-tenderdocumentofNambariORH1.pdf
ATTACHMENT
letterofcredit.pdf
ATTACHMENT
MicrosoftWord-ANNEXURES_August23to4thcorrectionslip.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .