Loading…
Loading…
Tender Value
₹83.7 L
EMD Value
₹1.7 L
Closing Date
30 Sept 2026, 11:00 am3d left
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of [V/N or 'V' whichever is less; where V = Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
Tenderer must have to submit valid Electrical Contractor license as per Indian Electricity Rules for the respective category of works issued by Government Electrical License Board on or before the closing date of tender. Copy of the electrical contractor license should be submitted along with the tender offer, otherwise, the tender will be summarily rejected.
The Similar nature of works for this instant tender shall be "Supply, installation, testing and commissioning of any LT/HT electrical work." The tenderer should have executed the similar nature of works in Central/State Government department or PSUs of Central /State Government."
50 conditions · 4 needing a document upload
Whether the cost of earnest money deposited
Migration to GST regime - Special Tender Conditions: The rates should clearly indicate the rate of applicable duties and taxes included in the prices quoted by them. Any variation in tax structure/ rate due to introduction of GST, shall be dealt with under Statutory Variation Clause. It should be ensure that bidders/tenderers are GST compliant and quoted tax structure/rates are as per GST Law.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should submit the GSTIN number and same should be mentioned in the bills along with a copy of GSTIN registration certificate while submitting the bills to accounts for audit and payment, As GST is scheduled to implemented wef 01.07.2017. Without GSTN, no bill will be accepted w.e.f. 01.07.2017
From 01.07.2017 GST has been implemented but the detail guideline is still not clear. Hence, new tax structure on materials and labour will be applicable to both Railway & contractor after getting proper notification
Payment of Earnest Money deposit (EMD) , in respect of e- tendering,should be accepted through net banking or online payment gateway only
Re-development and renovation of Agartala station - provision of 12 m FOB with Lift, Escalator, station building and improvement to circulating area in connection with development of Agartala Station (phase-1) (Electric portion).
EL-LM-26-27-03~NFR
EL-LM-26-27-03
Open
Works - General
180 Days
Hojai, Assam
₹0
₹1.7 L
3 Sept 2026
3 Sept 2026
16 Sept 2026
127 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 83,74,354.67 | ||
| — | 400.00 | — | — | ||
| Design, manufacture, display of wall /hanging / floormounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. | — | — | — | 11,34,788 | |
| — | 400.00 | — | — | ||
| Erection and installation of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided | — | — | — | 1,13,476 | |
| — | 4000.00 | — | — | ||
| Supply, fabrication, installation, testing and commissioning of station name signage in 3D illuminated/non-illuminated letters mounted on suitable structural frame, displaying station name in Hindi, English and Regional language, complete with all materials and accessories required for proper installation. The letters shall be of 3D raised type, fabricated from high quality acrylic/SS/aluminium composite material (ACP) with laser cut finish, having uniform thickness and smooth edges, with provision of internal LED illumination (if specified) using high efficiency LED modules, suitable driver, and wiring arrangement. The letters shall be weatherproof, UV resistant and suitable for outdoor installation under all climatic conditions. The supporting frame shall be made of MS/GI structure with proper anti-corrosive treatment and painting/powder coating, securely fixed to wall/structure with suitable fasteners, anchor bolts and supports. Proper alignment, spacing and aesthetic appearance shall be ensured as per approved drawing. The scope includes supply of all materials, fabrication of letters, structural frame, wiring, fixing, connection, testing and commissioning complete in all respects as per approved design and direction of the Engineer-in- Charge. | — | — | — | 10,42,600 | |
| — | 2.00 | — | — | ||
| Supply of 16 metre high mast lighting system complete with all accessories and equipment, comprising of polygonal/tapered steel mast shaft in two sections, manufactured from high tensile steel plates and hot dip galvanised as per IS 2629/IS 4759, designed to withstand wind loads as per IS:875 (Part-3). The high mast shall be complete with head frame assembly, suitable for mounting 9 Nos. luminaires symmetrically, provided with 3-point/4-point suspension system, galvanised lantern carriage arrangement, galvanised steel wire rope of 6 mm dia (7/19 construction), guide pulleys, and double drum winch mechanism for raising and lowering of luminaire carriage. The system shall include integral motorised power tool/winch mounted inside base compartment, with suitable control system, braking arrangement and manual override facility. The mast shall also be provided with lightning finial, base plate, anchor bolts, inspection door with locking arrangement, internal wiring provision, cable entry system, control gear boxes and all standard accessories required for complete high mast system. The item includes supply of all materials complete in all respects as per relevant IS standards and manufacturer's specifications. Foundation design, erection and commissioning shall be carried out separately.(The designing of high mast tower foundation should be done after testing of soil bearing capacity and approved by the competent authority). | — | — | — | 3,46,397.02 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of out door type light check control panel with 3 phase, 4-wire, complete with energy meter for energy logging & inbuilt timer based automatic control using real time clock plug auto cut switch, fuse & switches as given from item a to d below, to be mounted in a sheet steel cubical panel made of CRCA steel sheet of 3.0mm thickness on suitable size MS angle, flat etc.and to be fixed on ground by PCC and grouting bolt/nut . The panel shall be totally enclosed, weather, water, dust and vermin proof and grooved type gasket shall be provided as per IP 65 degree of protection.The panel shall be painted by powder coating over two coat of red oxide paint. All internal connection shall be done with 1100 volt grage flexible copper PVC cable of appropriate size and copper lug should be provided at both end. Meter reading window shall be provided in metering chamber. Each chamber/compartment shall have separate door and lock arrangement comprising of MCCB 4 pole 63 amps - 1 nos., MCB TPN 16 amps - 1 no., MCB DP - 20 amps - 3 no., 3 phase Reversing switch 25 amps - 1 no. | — | — | — | 1,51,274.26 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of twin dome aviation obstruction lights, suitable for mounting on high mast/tower structures, complete with two nos. red coloured obstruction light fittings (twin arrangement per mast), each fitted with 25 Watt neon/LED equivalent lamp, housed in weatherproof, UV-stabilized polycarbonate/acrylic dome with corrosion resistant die- cast aluminium/FRP base, suitable for continuous outdoor operation.The obstruction light shall be suitable for operation on 230 V, 50 Hz AC supply, with integrated control gear/driver, and shall comply with relevant aviation standards for obstruction lighting (steady burning red light) with uniform visibility over required distance. The fitting shall have adequate ingress protection (minimum IP65) and be suitable for mounting at the top of mast/tower structure. | — | — | — | 6,037.56 | |
| — | 2.00 | — | — | ||
| Supply and erection of PCC/RCC shallow foundation for towers of size and depth as per manufacturer's approved design and drawings, executed with concrete of nominal mix 1:2:4 (cement:sand:coarse aggregate) using graded stone aggregates of maximum size 20 mm and down, including all materials such as cement, fine aggregate, coarse aggregate, water and admixtures (if required), complete in all respects. The scope of work shall include setting out, excavation of foundation pits in all types of soil/rock at all depths, dressing and levelling of bed, dewatering (if required), shoring/strutting for safety, centering and shuttering, placement of reinforcement steel as per approved bar bending schedule, batching, mixing, placing, compacting using mechanical vibrator, curing, finishing and proper alignment of foundation including provision for anchor bolts/templates as per manufacturer's requirement. After completion, the pit shall be backfilled with excavated/approved earth in layers with proper compaction, including disposal of surplus earth as required, and restoration of site to original condition. The design of foundation shall be based on safe bearing capacity (SBC) of soil not less than 10 t/m², and shall consider all loads such as dead load, wind load and equipment load as per relevant IS codes. The contractor shall submit detailed foundation drawings, structural design calculations, loading data, sectional details and bar bending schedule (BBS) for approval of Railway competent authority prior to execution. The work shall be carried out complete in all respects as per approved drawings, relevant IS standards and direction of the Engineer-in-Charge at site. | — | — | — | 1,24,872.92 | |
| — | 2.00 | — | — | ||
| Erection, installation, testing and commissioning of high mast lighting tower complete as per approved drawings, manufacturer's specifications and modern engineering practices, including assembly of mast sections, head frame, lantern carriage, winch system, stainless steel wire ropes, pulleys, guide rollers, aviation obstruction light (if required), and all associated mechanical and electrical components. The work shall include proper alignment and vertical erection of mast over pre-cast/constructed foundation with foundation bolts, tightening of anchor bolts with required torque, installation of raising and lowering mechanism, mounting of luminaires on head frame, internal wiring with suitable FRLSH copper cables, termination, earthing connections and interconnection with feeder panel. The scope shall also include testing of winch mechanism, operation of raising and lowering system, insulation resistance test, functional testing of lighting system, checking of safety interlocks, and commissioning of complete high mast system to ensure safe and satisfactory operation. All tools, tackles, consumables, safety measures, manpower and accessories required for erection and commissioning shall be arranged by the contractor. The work shall be carried out complete in all respects as per direction of the Engineer-in-Charge at site. | — | — | — | 45,141.18 | |
| — | 20.00 | — | — | ||
| Supply and erection of earthing by 50 mm dia 3.60 mm thick 3 mtr long GI pipe with (25x5) mm GI strip & GI nut/bolts/washers etc as per CEE/MLGs diagram CEE/STD/1. | — | — | — | 10,866.6 | |
| — | 16.00 | — | — | ||
| Supply, fitting, fixing, connection, testing and commissioning of 150/160 Watt LED Flood Light fitting, complete set suitable for outdoor illumination, comprising of high efficiency LED module, integrated constant current electronic driver, pressure die-cast aluminium housing with corrosion resistant powder coated finish, high purity secondary optics (lens/reflector system) for uniform beam distribution, toughened glass cover, silicone gasket sealing arrangement and stainless steel hardware. The luminaire shall have ingress protection of IP65 or higher, suitable for outdoor environmental conditions, with surge protection device (minimum 4 kV), high power factor (0.95), low harmonic distortion, and suitable for operation on 230 V ±10%, 50 Hz AC supply. The fitting shall be complete with adjustable mounting bracket for tilt/aiming adjustment, suitable for pole/wall mounting, and capable of continuous operation under tropical climatic conditions with ambient temperature range 0°C to 50°C. The scope includes supply of all accessories, clamps, nuts, bolts, wiring connection using suitable FRLSH copper conductor cable, earthing connection, installation, alignment, testing, commissioning and demonstration of satisfactory operation complete in all respects as per manufacturer's specifications and direction of the Engineer-in-Charge. | — | — | — | 1,55,669.28 | |
| — | 10.00 | — | — | ||
| Supply, erection, testing and commissioning of 6.0 m height single arm( Crompton Cat. No. HM-DECO-SA-NS )decorative galvanised iron (GI) pole, hot dip galvanised as per IS 2629/IS 4759 with corrosion resistant powder coating/PU finish, complete with cast aluminium decorative single arm bracket, base plate, inspection door with locking arrangement, internal wiring provision, cable entry system, terminal box and all standard accessories required for safe outdoor installation. The pole shall be suitable for mounting of 1 No. 80 Watt tear drop type LED pendant luminaire, complete with high efficiency LED module, integrated constant current electronic driver, die-cast aluminium housing, polycarbonate diffuser, IP66 protection, surge protection and suitable for operation on 230 V, 50 Hz AC supply. The work shall also include RCC foundation as per manufacturer's approved design, including excavation, PCC/RCC foundation work, reinforcement steel (if required), anchor bolt template fixing, grouting, backfilling, compaction and finishing of ground surface to required level ensuring structural stability against wind load and site conditions. The scope includes complete supply of materials, erection of pole, mounting of luminaire, internal wiring with suitable copper conductor cable, earthing connection, testing, commissioning and demonstration of satisfactory operation as per manufacturer's specifications and direction of the Engineer-in-Charge. | — | — | — | 3,09,794.7 | |
| — | 8.00 | — | — | ||
| Supply, erection, testing and commissioning of 6.0 m height double arm (crompton cat no-HM-DECO-DA-NS or similar of Phillips /Bajaj/Havells) decorative galvanised iron (GI) pole, complete with cast aluminium decorative twin arms, hot dip galvanised as per IS 2629/IS 4759, suitable for outdoor street/landscape lighting application, including corrosion resistant powder coating/PU finish as per architectural requirement, complete with base plate, door opening for internal wiring, inspection cover, terminal box, cable entry arrangement and all standard accessories required for safe and durable installation. The pole shall be suitable for mounting of 80 Watt tear drop type LED pendant luminaires on both arms, complete with high efficiency LED module, integrated constant current driver, IP66 protection, surge protection, die-cast aluminium housing and polycarbonate diffuser, suitable for operation on 230 V, 50 Hz AC supply. The work shall also include RCC foundation as per manufacturer's design, including excavation, PCC, reinforcement steel (if required), anchor bolt fixing template, grouting, backfilling, compaction and finishing of surface to ground level, ensuring stability against wind load and environmental conditions. The scope includes complete supply of materials, erection of pole, mounting of luminaires, internal wiring with suitable copper conductor cables, earthing connection, testing, commissioning and demonstration of satisfactory operation as per manufacturer's specification and direction of the Engineer-in-Charge. | — | — | — | 3,74,718.64 | |
| — | 15.00 | — | — | ||
| Supply, fitting, fixing, erection and commissioning of 65 mm nominal diameter (medium class) galvanised iron (G.I.) pipe of 5 ft (1.5 m) length including necessary cutting, threading, welding (if required), alignment and rigid fixing over suitable RCC base foundation, complete with nut-bolt arrangement, base plate, clamps and all accessories required for proper installation of post top lamp. The work shall include construction of RCC foundation of adequate size and strength including excavation, PCC/RCC works, reinforcement (if required), grouting of foundation bolts, backfilling, compaction and finishing of surface to required level as per the direction of the Engineer-in-Charge. | — | — | — | 16,827.3 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of Solar Tree of minimum 1 kW capacity complete with high efficiency monocrystalline solar PV modules mounted on aesthetically designed MS/FRP/Aluminium structural "tree type" frame, corrosion resistant, powder coated and suitable for outdoor installation, including integrated MPPT charge controller, grid/standalone compatible inverter (if required), battery bank (maintenance free lithium/SMF type as per design), junction boxes, DC/AC distribution system, protection devices (MCB/MCCB/SPD, fuses), earthing system and complete wiring and cabling with UV resistant solar grade cables. The system shall be designed for charging facilities including USB charging ports and/or AC charging sockets as specified, with smart energy management system ensuring safe charging of mobile devices and small electronic gadgets. The solar tree shall also include integrated LED lighting arrangement for illumination of surrounding area with energy efficient LED fittings. The work shall further include provision of sitting arrangement integrated with the solar tree structure, consisting of durable weather-resistant benches/seatings made of treated wood/FRP/metal as approved, firmly anchored to foundation with RCC pedestal/base, complete with civil foundation works including excavation, PCC/RCC foundation, grouting, anchoring bolts, backfilling and site restoration. The system shall be suitable for tropical climatic conditions with wind load resistance as per IS 875 standards, protection against overcharge, deep discharge, short circuit, reverse polarity and surge protection. The complete work includes supply of all materials, erection, civil foundation, installation, wiring, testing, commissioning, performance demonstration and handing over in satisfactory working condition as per manufacturer's specification and direction of the Engineer-in-Charge. | — | — | — | 2,10,000 | |
| — | 15.00 | — | — | ||
| Supply, fitting, fixing, wiring, testing and commissioning of mobile charging point system with mobile keeping tray, suitable for concealed/surface wiring as required at site, complete with modular accessories and all necessary materials. The wiring shall be carried out using 1.5 sq.mm single core PVC insulated, flexible industrial grade, FRLSH copper conductor cable (unsheathed) drawn through heavy duty rigid PVC conduit (concealed/surface type) including all accessories such as bends, tees, junction boxes, couplers and saddles as required. Earth continuity shall be provided using 1 sq.mm single core PVC insulated unsheathed flexible copper conductor wire. The point shall be provided with modular type switches and sockets mounted on high quality modular plate and frame of suitable size, fixed on PVC/metal mounting box of minimum 3 mm thickness and internal depth not less than 50 mm, complete with screws, supports and accessories. The system shall include 6 A modular switches - 03 Nos. and 6/10 A, 5-pin modular sockets - 03 Nos., with proper internal wiring, termination, ferruling and interconnection. A mobile holding tray of suitable design and strength shall be provided for safe placement of mobile devices during charging. All accessories including PVC bends, tees, junction boxes, cover plates, screws and fixing materials shall be supplied by the contractor. In case of concealed wiring, making good of wall surface including plastering and painting matching with existing surface finish shall be done by the contractor at site. The work shall be carried out complete in all respects including supply, installation, connection, testing and commissioning as per site requirement and direction of the Engineer-in-Charge. | — | — | — | 13,721.4 | |
| — | 5.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of Crosscut furniture tripod floor lamp complete with integrated 12 Watt LED warm white light source, high efficiency LED module with in-built constant current electronic driver, suitable for operation on 230 V, 50 Hz single phase AC supply. The lamp shall be provided with aesthetically designed tripod stand made of high quality engineered wood/metal frame with stable base arrangement, fabric/metallic lamp shade for glare free warm illumination (approx. 3000K), power cable with plug top, on/off switch and all necessary internal wiring and fittings. The luminaire shall be suitable for decorative indoor lighting application with uniform light distribution, low power consumption and long service life, having high power factor (0.90) and surge protection as per manufacturer's standard design. The scope includes supply of all accessories, assembly, fixing, positioning at designated location, electrical connection, testing and commissioning complete in all respects as per manufacturer's specifications and direction of the Engineer-in-Charge at site. | — | — | — | 13,800 | |
| — | 20.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of 20 Watt LED track light fitting suitable for indoor architectural, display and accent lighting application, compatible with standard 3- phase/1-phase track rail system as applicable, complete with high efficiency COB/SMD LED light source, integrated constant current electronic driver, high quality aluminium die-cast housing with heat sink arrangement, adjustable swivel/tilt mechanism for directional focusing and glare control optical reflector/lens system, suitable for operation on 230 V, 50 Hz AC supply. The luminaire shall provide warm white light output (approx. 3000K) with high colour rendering index (CRI 80), high luminous efficacy and uniform beam distribution suitable for retail, corridor, station concourse and display area illumination. The fitting shall have surge protection, power factor 0.90 and long operational life with minimum 50,000 burning hours (L70). The track light shall be as per Philips Model No. 31446 Warm White or equivalent model of approved make having similar technical specifications and appearance.The scope includes supply of all mounting accessories, track adapter, connectors, wiring, fixing, alignment, testing and commissioning complete in all respects as per manufacturer's specification and direction of the Engineer-in-Charge. | — | — | — | 1,04,800 | |
| — | 50.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of 1500 mm sweep, 5-star rated energy efficient ceiling fan of BLDC (Brushless DC Motor) type suitable for operation on 230 V, 50 Hz single phase AC supply, having ultra-low power consumption, high air delivery, and noiseless operation. The fan shall be electronically commutated with in-built intelligent controller for speed regulation and shall be suitable for operation through remote control/wall control as per manufacturer design. The fan shall have aerodynamically designed aluminium/ABS blades with anti- dust coating, dynamically balanced rotor assembly, double ball bearing system for smooth operation and longer service life. The motor shall be high efficiency BLDC type with power factor 0.95, energy efficiency as per BEE 5-star rating norms, and suitable thermal protection for continuous duty operation under Indian climatic conditions. | — | — | — | 1,60,000 | |
| — | 4.00 | — | — | ||
| Supply, fitting, installation, testing and commissioning of 5 kVA pure sine wave inverter system suitable for 72 V DC battery bank input, microprocessor/DSP controlled, high efficiency (>85%) static inverter with built-in protection features such as overload, short circuit, deep discharge, overcharge, reverse polarity, thermal protection and automatic changeover facility, suitable for operation on 230 V ±10%, 50 Hz single phase AC output, complete with inbuilt battery charger of suitable rating, LCD/LED display for system status monitoring, alarms and indication system. The inverter shall be supplied with heavy duty powder coated MS trolley suitable for mounting of inverter and battery bank, with wheels for easy mobility, proper ventilation arrangement and provision for cable management. The scope shall include supply of all necessary accessories such as input/output cables, lugs, connectors, MCBs, fuses, terminals and interconnecting wiring between inverter and battery bank. The work shall include fitting, fixing, connection, testing, commissioning and demonstration of full load operation along with proper earthing, polarity checking and functional testing complete in all respects as per manufacturer's specifications and direction of the Engineer-in-Charge. | — | — | — | 1,33,632 | |
| — | 24.00 | — | — | ||
| Supply, installation, testing and commissioning of 150 AH, 12 V maintenance free sealed maintenance free (SMF) / valve regulated lead acid (VRLA) battery conforming to latest IS/IEC 60896 standards with all up-to-date amendments, suitable for UPS/inverter/DC power backup applications, having low internal resistance, high charge acceptance, deep cycle capability and low self-discharge characteristics, designed for operation under tropical climatic conditions, complete with factory fresh condition, test certificate and minimum one year warranty from the date of commissioning. The scope shall include supply of all necessary consumables and accessories such as battery interconnecting links, copper/aluminium terminals, nut-bolt sets, insulation sleeves/covers, anti-corrosive petroleum jelly, battery end connectors and suitable battery stand/rack arrangement, including shifting, positioning, fixing, alignment, interconnection, tightening of terminals, application of anti-corrosive protection, checking of polarity, voltage verification, load testing (where required), insulation and continuity checks, and commissioning complete in all respects as per manufacturer's recommendations and direction of the Engineer-in-Charge at site. | — | — | — | 3,08,400 | |
| — | 10.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of 12 Watt LED in-ground (ground burial) luminaire, suitable for installation in outdoor landscape/footpath/pavement/architectural lighting works, complete with corrosion resistant die-cast aluminium housing, stainless steel 304/316 grade bezel/frame, and toughened tempered glass diffuser capable of withstanding pedestrian load and occasional vehicular load as per manufacturer design. The luminaire shall be fully sealed construction with ingress protection not less than IP67, impact resistance IK10 or better, and shall be suitable for tropical climatic conditions. The fitting shall be complete with high efficiency LED module, thermally efficient heat sink arrangement, and integrated constant current electronic driver suitable for operation on 230 V AC, 50 Hz single phase supply with operating voltage range 90-260 V AC. Technical Parameters: System Wattage: 12 Watt Rated Voltage: 240 V AC, 50 Hz Operating Voltage Range: 90-260 V AC Operating Temperature: -10°C to +50°C Power Factor: 0.90 CRI: 70 Luminous Efficacy: 90-100 lm/W (minimum) Protection Class: IP67 (minimum) Impact Resistance: IK10 or better Surge Protection: Minimum 2.5 kV built-in.The installation Work Includes: Excavation of ground, making of suitable pit, providing gravel/sand bedding for drainage, laying of luminaire, proper alignment at finished ground level, backfilling, compaction, restoration of surface, cable termination, earthing connection, and testing & commissioning complete in all respects. | — | — | — | 54,563.1 | |
| — | 10.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of 4-way linear decorative LED fixture ,rated power 5 Watt suitable for architectural / facade / landscape lighting application, complete with high strength extruded aluminium housing with corrosion resistant powder coated finish, UV stabilized polycarbonate diffuser and end caps, suitable for outdoor use with ingress protection of IP67, impact resistance IK07 or better, including integrated constant current electronic LED driver (resin potted / sealed type), high efficiency LED SMD light source mounted on aluminium PCB with proper thermal management system, and all standard accessories required for safe and satisfactory operation. The fixture shall be suitable for operation on 230 V ±10%, 50 Hz AC supply with surge protection not less than 2.5 kV, power factor 0.90, THD < 10%, colour temperature Cool White 5700K ± 500K, CRI 70 and system efficacy not less than 100 lumens/Watt. The fixture shall have minimum rated life of 50,000 burning hours (L70) under standard operating conditions. The luminaire shall be suitable for wall mounting / surface mounting application with stainless steel fixing accessories, concealed brackets, and complete wiring termination arrangement. The fixture shall be suitable for continuous outdoor operation under tropical climatic conditions with ambient temperature range 0°C to 50°C. The work shall include supply of all materials, fittings, fixing accessories, wiring connections, testing, commissioning and making good the surface complete in all respects as per direction of the Engineer-in-Charge. | — | — | — | 84,537.6 | |
| — | 2.00 | — | — | ||
| Supply, fitting, installation, testing and commissioning of VTPN Distribution Board, IP- 43 protected, double door type, suitable for 415 V, 3 Phase, 4 Wire, 50 Hz system, fabricated from CRCA sheet steel with powder coated finish, dust and vermin proof construction, suitable for wall mounting, complete with internal wiring, neutral link, earth bar, DIN rail, cable termination accessories, gland plate and all standard accessories required for safe and satisfactory operation. The DB shall be complete with the following switchgears: (i) 4 Pole MCCB, 160 A - 01 No. (Incomer) (ii) 4 Pole MCB (TPMCB), suitable rating - 06 Nos. (Outgoing feeders) (iii) Single Pole MCB - 18 Nos. (Outgoing feeders) All MCCB/MCBs shall have suitable breaking capacity conforming to IS/IEC standards with thermal magnetic protection. The distribution board shall be properly phase balanced, ferruled, labeled, earthed and interconnected for safe operation. The work includes supply, fixing, connection, testing and commissioning of complete VTPN DB in all respects as per approved drawing, site requirement and direction of Engineer-in-Charge. | — | — | — | 1,20,000 | |
| — | 2.00 | — | — | ||
| Supply, fitting, installation, testing and commissioning of TPN Distribution Board (DB) suitable for 415 V, 3 Phase, 4 Wire, 50 Hz system, of sheet steel CRCA construction, powder coated finish, dust and vermin proof, floor/wall mounted type with metal door, having minimum 24 module capacity and suitable for 24 outgoing single phase circuits, complete with internal wiring, neutral link, earth bar, DIN rail, cable termination accessories, gland plate and all standard accessories required for safe and satisfactory operation. The DB shall be complete with the following switchgears: (i) 4 Pole MCB, 63 A - 01 No. (Incomer) (ii) Single Pole MCB (6-32 A) - 24 Nos. (Outgoing feeders) All MCBs shall have suitable breaking capacity conforming to IS/IEC standards with thermal magnetic protection and shall be of appropriate fault level rating. The DB shall be properly phased balanced, ferruled, labeled, earthed and interconnected for safe operation. The work includes supply, fixing, connection, testing and commissioning of complete DB in all respects as per approved drawing, site requirement and direction of Engineer-in-Charge. | — | — | — | 26,981.78 | |
| — | 900.00 | — | — | ||
| Making of cable trench dimension 300 mm wide and 1000mm deep by excavation of earth. The cable shall be protected by laying of brick in 3 sides with filling of sand as per the direction of Engineer in charge at site (Outside track crossing) and backfilling of earth/ ballast.The work shall include protection of laid cable by providing brick protection on three sides (bottom and both sides) using standard size burnt clay bricks laid properly with cement mortar where required, filling of fine sand around and over the cable for cushioning and protection, and ensuring proper compaction. After laying and protection of cable, the trench shall be backfilled with excavated earth/ballast in layers, properly compacted and dressed to original ground level/formation. Disposal of surplus material, if any, shall also be included. | — | — | — | 45,045 | |
| — | 200.00 | — | — | ||
| Making of bore for putting the cable under the track/road (Inside track/road boring) by crossing it through requisite dia as per direction of Engineer in charge at site.The work shall include setting out, site preparation, excavation of entry and exit pits, boring/drilling, maintaining alignment and required depth, protection of existing track/road structure and utilities, and insertion of suitable casing/protection pipe for cable laying. The scope also includes restoration of disturbed surfaces, backfilling, compaction, disposal of surplus earth, and making good the site to original condition complete in all respects as per direction of the Engineer-in-Charge at site. | — | — | — | 35,666 | |
| — | 300.00 | — | — | ||
| Supply, installation, laying, fitting, testing and commissioning of HDPE Pipe of 160 mm nominal diameter having wall thickness 6.2 mm, conforming to IS:4984/1995, suitable for underground/above ground utility application, complete with all necessary fittings, accessories and jointing materials required for proper installation. The work shall include handling, transportation, alignment, cutting, jointing by suitable method, fixing, supporting, testing and commissioning of the pipeline complete in all respects as per approved specifications and direction of the Engineer-in- Charge at site. | — | — | — | 1,17,834 | |
| — | 300.00 | — | — | ||
| Supply, fitting, fixing and laying of HDPE pipe of 110 mm outside diameter, working pressure 6 kgf/cm², in standard 6.0 metre length conforming to IS:4984/1995, complete with necessary threaded fittings/accessories such as tees, elbows, unions, sockets, couplers and specials required for proper installation. The HDPE pipe shall be securely clamped/fixed on pole/truss/bracket using galvanised MS flat clamp of size 50 mm x 6 mm complete with galvanised nuts and bolts of size 12 mm x 50 mm and all supporting hardware required for rigid and safe installation. The work shall include cutting, threading/jointing, alignment, fixing, supporting and proper fastening of pipe complete in all respects as per site requirement and direction of the Engineer-in-Charge at site. | — | — | — | 1,03,275 | |
| — | 600.00 | — | — | ||
| Supply, fitting, fixing and laying of 90 mm dia HDPE pipe conforming to IS:4984/1995 of working pressure 6 kgf/cm², having wall thickness of 7.6 mm, suitable for cable protection application, complete with all necessary accessories such as sockets, bends, couplers, tees, elbows, unions, reducers, clamps and specials required for proper installation. The pipe shall be properly aligned, jointed and clamped with suitable MS brackets/supports at required intervals. Threaded adaptors/fittings shall be provided wherever required to match with GI pipe fittings such as tees, elbows, unions and sockets for proper interconnection. The work shall include cutting, threading/jointing, fixing, laying, supporting and testing complete in all respects for welding line cable protection application as directed by the Engineer-in-Charge at site. | — | — | — | 1,22,460 | |
| — | 200.00 | — | — | ||
| Supply, laying, fitting and fixing of 100 mm dia Cast Iron (CI) Pipe, Class-B conforming to IS:1536/2001 with latest amendments, complete with all necessary accessories, fittings, jointing materials and specials required for proper installation. The work shall include handling, lowering, alignment, cutting, jointing, testing and commissioning of the pipeline complete in all respects as per approved specifications and direction of the Engineer-in-Charge. | — | — | — | 1,59,216 | |
| — | 6.00 | — | — | ||
| Supply, erection, testing and commissioning of 4 Core heat shrinkable type LT cable termination kit suitable for 70/95 sq.mm size, 1100 Volt grade XLPE/PVC insulated armoured cable, suitable for indoor/outdoor application, complete with all required components and accessories such as heat shrinkable sleeves, breakout boots, anti-tracking tubes, sealing mastic, insulating tape, ferrules, glands, tinned/aluminium lugs, earthing accessories and all consumables required for proper termination of cable. The work shall include cable preparation, armour clamping, gland fixing, crimping of lugs, heat shrinking, insulation of cores, continuity and insulation resistance testing, and commissioning complete in all respects for satisfactory operation as per relevant IS specifications and direction of the Engineer-in-Charge/Site Incharge. | — | — | — | 13,512 | |
| — | 6.00 | — | — | ||
| Supply, erection, testing and commissioning of 4 Core heat shrinkable type LT cable termination kit suitable for 185 sq.mm to 300 sq.mm size, 1100 Volt grade XLPE/PVC insulated armoured cable, suitable for indoor/outdoor application, complete with all required components and accessories such as heat shrinkable sleeves, breakout boots, anti-tracking tubes, sealing mastic, insulating tape, ferrules, glands, tinned/aluminium lugs, earthing accessories and all consumables required for proper termination of cable. The work shall include cable preparation, armour clamping, gland fixing, crimping of lugs, heat shrinking, insulation of cores, continuity and insulation resistance testing, and commissioning complete in all respects for satisfactory operation as per relevant IS specifications and direction of the Engineer-in-Charge/Site Incharge. | — | — | — | 17,106 | |
| — | 6.00 | — | — | ||
| Supply, erection, testing and commissioning of 4 Core heat shrinkable type LT cable termination kit suitable for 120/150/185 sq.mm size, 1100 Volt grade XLPE/PVC insulated armoured cable, suitable for indoor/outdoor application, complete with all required components and accessories such as heat shrinkable sleeves, breakout boots, anti-tracking tubes, sealing mastic, insulating tape, ferrules, glands, tinned/aluminium lugs, earthing accessories and all consumables required for proper termination of cable. The work shall include cable preparation, armour clamping, gland fixing, crimping of lugs, heat shrinking, insulation of cores, testing and commissioning complete in all respects for satisfactory operation as per relevant IS specifications and direction of the Engineer-in-Charge/Site Incharge. | — | — | — | 27,084.72 | |
| — | 200.00 | — | — | ||
| Providing Horizontal Directional Drilling (HDD) / trenchless horizontal boring for crossing of road/Railway track embankment at minimum distance of 6.0 metres from edge of embankment and at minimum depth of 2.0 metres below ground level (GL), including preparation of site, alignment marking, pit excavation, positioning of HDD machine, pilot boring, reaming and pulling of suitable protection pipe for laying of electrical cable complete through contractor's own arrangement. The work shall include making of 300 mm dia bore hole, handling of boring slurry, dewatering if required, protection of existing utilities, disposal of surplus earth/debris, refilling and restoration of site to original condition complete in all respects as per site requirement and direction of the Engineer-in-Charge. The contractor shall arrange all labour, HDD machine, tools & plants, consumables, temporary supports, safety precautions and accessories required for satisfactory completion of work without disturbing existing road/rail traffic and services. | — | — | — | 12,24,400 | |
| — | 900.00 | — | — | ||
| Laying, commissioning of LT/HT cable XLPE insulated power cables with armoured aluminum conductors of different sizes partly along the pole and partly through ground in cable trench. Loading, unloading & carrying of cable to actual work site by contractor own arrangement as per instruction of Engineer in charge at site. (Cable will be supplied by Railway.) | — | — | — | 27,405 | |
| — | 200.00 | — | — | ||
| Supply, laying, fitting and fixing of 40 mm dia heavy duty rigid PVC conduit pipe suitable for electrical wiring application, complete with all accessories such as bends, couplers, junction boxes, saddles, inspection boxes, bushings and clamps, fixed on wall/ceiling or concealed in slab/wall as required. The conduit shall be of heavy duty type conforming to relevant IS standards and suitable for mechanical protection of electrical cables/wires. The work shall include cutting, bending, fixing with suitable clamps/saddles and all accessories required for satisfactory completion of work as directed by the Engineer-in-Charge. | — | — | — | 7,962 | |
| — | 200.00 | — | — | ||
| Supply, laying, fitting and fixing of 25 mm dia heavy duty rigid PVC conduit pipe suitable for electrical wiring application, complete with all accessories such as bends, couplers, junction boxes, saddles, inspection boxes, bushings and clamps, fixed on wall/ceiling or concealed in slab/wall as required. The conduit shall be of heavy duty type conforming to relevant IS standards and suitable for mechanical protection of electrical cables/wires. The work shall include cutting, bending, fixing with suitable clamps/saddles and all accessories required for satisfactory completion of work as directed by the Engineer-in-Charge. | — | — | — | 3,362 | |
| — | 200.00 | — | — | ||
| Supply, laying, fitting and fixing of 20 mm dia heavy duty rigid PVC conduit pipe suitable for electrical wiring application, complete with all accessories such as bends, couplers, junction boxes, saddles, inspection boxes, bushings and clamps, fixed on wall/ceiling or concealed in slab/wall as required. The conduit shall be of heavy duty type conforming to relevant IS standards and suitable for mechanical protection of electrical cables/wires. The work shall include cutting, bending, fixing with suitable clamps/saddles and all accessories required for satisfactory completion of work as directed by the Engineer-in-Charge. | — | — | — | 2,230 | |
| — | 20.00 | — | — | ||
| Complete dismantling and uprooting/retrieving of existing rail pole/steel tubular pole/RSJ pole of size 40 kg/47 kg/52 kg rail section or equivalent, including dismantling of fittings and accessories wherever required, breaking and removal of cement concrete foundation by excavation, earth digging, uprooting of pole complete and stacking of released materials at suitable location as directed by the Engineer-in-Charge. The work shall also include refilling of excavated pit with available earth, proper compaction, dressing and finishing of surface complete in all respects as per site requirement and direction of the Engineer-in-Charge at site. | — | — | — | 17,523 | |
| — | 15.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of recessed mounting type mirror optic 15 Watt LED square downlight luminaire suitable for indoor false ceiling application, complete with high efficiency LED module, mirror optic reflector system, glare free diffuser, in-built constant current electronic driver, heat sink arrangement and all standard accessories required for satisfactory operation, suitable for operation on 230 Volts AC, 50 Hz supply. The luminaire shall have minimum system efficacy greater than 100 lumens/Watt and correlated colour temperature (CCT) of 6500K (Cool Day Light). The fitting shall provide uniform illumination with low power consumption and long service life. The housing shall be made of CRCA/pressure die-cast aluminium with powder coated finish and suitable spring loaded clips for recessed mounting in false ceiling. The driver shall have protection against short circuit, over-voltage and surge conditions. The scope includes supply, erection, fitting, fixing, connection, testing and commissioning complete with LED lamps/modules, mounting accessories, connectors and all hardware required for satisfactory installation and operation as directed by the Engineer-in-Charge. | — | — | — | 25,779.75 | |
| — | 10.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of recessed mounting LED light fitting of 18/20 Watt suitable for indoor false ceiling application, complete with CRCA/pressure die- cast aluminium housing, high efficiency LED module, glare free diffuser, integrated constant current electronic driver, heat sink arrangement and all standard accessories required for satisfactory operation, suitable for operation on 230 Volts AC, 50 Hz supply. The fitting shall provide uniform illumination with low power consumption, high luminous efficacy and long service life. The luminaire shall have minimum power factor of 0.95, CRI 80 and suitable colour temperature as approved by the Engineer-in-Charge. The LED fitting shall be as per Crompton Cat. No. LSDEP-18-CDL or equivalent model of Philips/Bajaj or other approved make having similar technical specifications and appearance. The work shall include supply, fitting, fixing, connection, testing and commissioning complete with all mounting accessories, connectors, hardware and wiring required for satisfactory installation and operation as directed by the Engineer-in-Charge. | — | — | — | 15,200 | |
| — | 10.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of recessed mounting LED Downlight fitting of 8/9 Watt suitable for indoor lighting application, complete with pressure die-cast aluminium/CRCA housing, high efficiency LED module, glare free diffuser, integrated constant current electronic driver, heat sink arrangement and all standard accessories required for satisfactory operation, suitable for operation on 230 Volts AC, 50 Hz supply. The fitting shall be suitable for false ceiling recessed mounting and shall provide uniform illumination with low power consumption and high luminous efficacy. The luminaire shall have minimum power factor of 0.95, CRI 80 and suitable colour temperature as approved by the Engineer-in-Charge. The LED Downlight fitting shall be as per Crompton Cat. No. LCDRO-09-CDL or equivalent model of Philips/Bajaj or other approved make having similar technical specifications and appearance. The work shall include supply, fitting, fixing, connection, testing and commissioning complete in all respects with necessary mounting accessories, connectors and hardware as directed by the Engineer-in-Charge. | — | — | — | 13,600 | |
| — | 5.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of 12 Watt LED Picture Light fitting suitable for decorative illumination of paintings, artwork, display panels and photographs, complete with aesthetically designed metallic housing, high efficiency LED light source, integrated electronic driver, diffuser/lens arrangement and all standard accessories required for satisfactory operation, suitable for operation on 230 Volts AC, 50 Hz supply. The fitting shall provide uniform glare-free illumination and shall be suitable for wall mounting application. The luminaire shall be complete with mounting brackets, hardware, wiring connections and powder coated/finished body as required for decorative indoor use. The picture light fitting shall be as per Philips Model No. 31403 Muzris or equivalent model of approved make having similar technical specifications and appearance. The work includes supply, fitting, fixing, connection, testing and commissioning complete in all respects as directed by the Engineer-in-Charge at site. | — | — | — | 17,750 | |
| — | 10.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of 12 Watt recessed/surface mounted LED Spot Light fitting suitable for indoor accent and decorative lighting application, complete with pressure die-cast aluminium housing, high efficiency LED module, integrated constant current electronic driver, heat sink arrangement and glare free optical diffuser/lens system suitable for operation on 230 Volts AC, 50 Hz supply. The fitting shall have minimum system efficacy of 90 lumens/Watt, power factor not less than 0.95, colour rendering index (CRI) 80 and correlated colour temperature (CCT) as specified by Engineer-in-Charge. The luminaire shall be complete with powder coated finish, spring loaded clips/brackets for mounting and all standard accessories required for satisfactory installation and operation. The LED driver shall have protection against short circuit, over-voltage and surge conditions. The luminaire shall be suitable for continuous operation under indoor conditions and conform to relevant IS/IEC standards. The scope includes supply, fitting, fixing, connection, testing and commissioning complete with necessary hardware, connectors and wiring accessories as required at site and as directed by the Engineer-in-Charge. | — | — | — | 34,200 | |
| — | 1000.00 | — | — | ||
| Supply, laying, drawing and fixing of sub-main wiring using single core 4 sq.mm PVC insulated multistrand flexible copper conductor cable complete with earth continuity conductor by 16 SWG bare copper wire, drawn through good quality hard PVC casing-capping/conduit complete with all accessories such as bends, tees, couplers, junction boxes and saddles. One running metre shall consist of two wires. The PVC casing/capping shall be fixed on wall/ceiling surface using MS screws of size 6 mm x 40 mm with suitable rawl plugs at intervals not exceeding 300 mm or as directed by the Engineer-in-Charge. The work shall include proper dressing of cables, termination, continuity testing and all accessories required for satisfactory completion of work complete in all respects as per site requirement and direction of the Engineer-in-Charge. | — | — | — | 66,810 | |
| — | 30.00 | — | — | ||
| Supply, wiring, fitting and fixing of 5/6 Amps, 5 pin plug point complete with flush type 5/6 Amps controlling switch mounted on hard plastic moulded board, including surface type wiring using single core 1.5 sq.mm PVC insulated multistrand flexible copper conductor cable drawn through good quality hard PVC casing-capping/conduit complete with all accessories such as bends, tees, couplers, junction boxes and saddles. The point wiring shall include earth continuity conductor by 16 SWG bare copper wire complete with proper termination and connections. The PVC casing/capping shall be fixed on wall/ceiling surface using MS screws of size 6 mm x 40 mm with suitable rawl plugs at intervals not exceeding 300 mm or as directed by the Engineer-in-Charge. The work shall include supply, fixing, connection, testing and commissioning complete in all respects with all necessary hardware, accessories and making good damaged surfaces as required at site. | — | — | — | 4,414.8 | |
| — | 30.00 | — | — | ||
| Supply, wiring, fitting and fixing of 15/16 Amps, 6 pin plug point complete with flush type 15/16 Amps controlling switch mounted on hard plastic moulded board, including surface type wiring using single core 4 sq.mm PVC insulated multistrand flexible copper conductor cable drawn through good quality hard PVC casing-capping/conduit complete with all accessories such as bends, tees, couplers, junction boxes and saddles. The point wiring shall include earth continuity conductor by 16 SWG bare copper wire complete with proper termination and connections. The PVC casing/capping shall be fixed on wall/ceiling surface using MS screws of size 6 mm x 40 mm with suitable rawl plugs at intervals not exceeding 300 mm or as directed by the Engineer-in-Charge. The work shall include supply, fixing, connection, testing and commissioning complete in all respects with all necessary hardware, accessories and making good damaged surfaces as required at site | — | — | — | 9,169.8 | |
| — | 15.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of 450 mm sweep heavy duty air circulating fan suitable for continuous operation, complete with motor, fan blades, mounting bracket/clamp, oscillation arrangement wherever applicable, wiring connections and all standard accessories required for satisfactory operation. The fan shall be suitable for operation on 230 Volts AC supply and designed for effective air circulation in indoor areas. The entire work shall be carried out complete in all respects as per site requirement and direction of the Engineer-in-Charge at site. | — | — | — | 91,769.55 | |
| — | 50.00 | — | — | ||
| Supply, fitting, fixing, connection, testing and commissioning of 18/20 Watt LED indoor light fitting complete with LED tube, electronic driver, holder, mounting accessories and all other necessary components required for satisfactory operation, suitable for operation on 230 Volts AC supply. The fitting shall be connected using 1.5 sq.mm FR PVC insulated multistrand flexible copper conductor wire drawn through suitable size PVC conduit/casing-capping as required at site, complete with proper termination, ferruling, connectors and fixing accessories. The entire work shall be carried out complete in all respects including wiring, fixing, testing and commissioning as per site requirement and direction of the Engineer-in-Charge. | — | — | — | 16,142 | |
| — | 500.00 | — | — | ||
| Supply and wiring using 0.75 sq.mm single core FR PVC insulated industrial grade multistrand flexible copper conductor cable conforming to IS:694, suitable for operation up to 1100 Volts, complete with drawing/pulling through existing conduit/casing, proper termination, ferruling, connectors and all necessary accessories required for satisfactory completion of work as directed by the Engineer-in-Charge. | — | — | — | 7,775 | |
| — | 500.00 | — | — | ||
| Supply and wiring for light fitting connection using 1.5 sq.mm single core FR PVC insulated industrial grade multistrand flexible copper conductor cable conforming to IS:694, suitable for operation up to 1100 Volts, complete with drawing/pulling through existing conduit/casing as required, proper termination, ferruling, connectors and all accessories required for satisfactory completion of work as directed by the Engineer-in-Charge. | — | — | — | 14,830 | |
| — | 200.00 | — | — | ||
| Supply and wiring for light fitting connection using 2.5 sq.mm single core FR PVC insulated industrial grade multistrand flexible copper conductor cable conforming to IS:694, suitable for operation up to 1100 Volts, complete with drawing/pulling through existing conduit/casing as required, proper termination, ferruling, lugs, connectors and all accessories required for satisfactory completion of work as directed by the Engineer-in-Charge. | — | — | — | 9,444 | |
| — | 300.00 | — | — | ||
| Supply and wiring for light fitting connection using 4 sq.mm single core FR PVC insulated industrial grade multistrand flexible copper conductor cable conforming to IS:694, suitable for operation up to 1100 Volts, complete with drawing/pulling through existing conduit/casing as required, proper termination, ferruling, lugs, connectors and all accessories required for satisfactory completion of work as directed by the Engineer-in-Charge. | — | — | — | 21,849 | |
| — | 1000.00 | — | — | ||
| Supply, laying, drawing and fixing of sub-main wiring using single core 6 sq.mm PVC insulated, unsheathed, FRLSH multistrand flexible copper conductor cable complete with earth continuity conductor by 16 SWG bare copper wire, drawn through heavy duty rigid PVC casing- capping/conduit of suitable size complete with all accessories such as bends, tees, junction boxes, couplers, saddles, screws and rawl plugs. The PVC casing/conduit shall be fixed on wall/ceiling surface using MS screws of size 6 mm x 40 mm with suitable rawl plugs at intervals not exceeding 300 mm or as directed by the Engineer-in-Charge. One run metre shall consist of two wires. The work shall include proper dressing of cables, termination, ferruling, continuity testing and making good damaged surfaces complete in all respects as per site requirement and direction of the Engineer-in-Charge. | — | — | — | 66,590 | |
| — | 200.00 | — | — | ||
| Supply, laying, fixing and wiring of concealed type main line using 1.1 kV grade HRFR PVC insulated single core 10 sq.mm multistrand flexible copper conductor cable conforming to IS:694/1990, drawn through suitable size 25 mm dia heavy duty PVC conduit pipe concealed in wall/ceiling/floor complete with necessary bends, junction boxes, inspection boxes, saddles, couplers and accessories. The work shall also include providing earth continuity conductor using HRFR PVC insulated single core multistrand flexible copper wire complete with proper termination, ferruling and connections as required. The entire work shall be carried out complete with chasing, recessing, fixing of conduit, making good damaged surfaces and testing of wiring installation complete in all respects as per site requirement and direction of the Engineer-in-Charge. | — | — | — | 45,140 | |
| — | 15.00 | — | — | ||
| Supply, fitting, fixing, testing, installation and commissioning of 45 Watt outdoor type LED Street Light fitting made of pressure die-cast aluminium housing with high power LED as lighting source and lens embedded polycarbonate (PC) cover, having top opening separate driver compartment, suitable for operation on 230 Volts AC supply, complete with integrated electronic driver, surge protection and all standard accessories. The luminaire shall have minimum IP-66 degree of protection and impact resistance of IK-07 suitable for outdoor application. The fixture shall be energy efficient, weatherproof and suitable for mounting on pole/bracket for roadway/street lighting application.The LED Street Light fitting shall conform to the technical specifications attached with the tender document and relevant IS/IEC standards. The scope includes supply, fitting, fixing, wiring connection, testing and commissioning complete with all necessary hardware, clamps, nuts, bolts and accessories required for satisfactory operation of the fitting. The entire work shall be executed complete in all respects as per approved specification and direction of the Engineer-in- Charge at site. | — | — | — | 59,926.95 | |
| — | 2.00 | — | — | ||
| Design, fabrication, supply, erection, installation, testing and commissioning of floor mounted LT Panel Board suitable for operation on 415 Volts, 3 Phase, 4 Wire, 50 Hz AC supply, fabricated from CRCA sheet steel enclosure with dust and vermin proof construction, complete with powder coated finish, suitable copper busbars of 250 Amps capacity, neutral busbar, earth busbar, internal wiring, cable alleys, gland plates, indication lamps, digital/analog ammeter, voltmeter with selector switch, CTs, interconnections and all standard accessories complete. The panel shall be complete with the following switchgears: i) 4 Pole, 250 Amps MCCB - 02 Nos. ii) 4 Pole, 125 Amps MCCB - 02 Nos. iii) 4 Pole, 63 Amps MCCB - 02 Nos. iv) 4 Pole, 32 Amps MCCB - 02 Nos. All MCCBs shall have Ics = 100% of Icu , suitable breaking capacity, thermal magnetic type with adjustable trip settings, conforming to relevant IS/IEC standards. The panel shall include internal wiring, control wiring, busbar sleeving, earthing terminals and provision for cable termination complete. The work includes supply, assembly, wiring, installation, testing and commissioning of the LT panel board complete in all respects as per approved drawing, site requirement and direction of Engineer-in- Charge. The panel should be completed with voltmeter, ammeter, selector switch, CTs, control fuses & LED indicators. Control & Metering: Digital Voltmeter with selector switch. KWH Energy meter with CTs of suitable rating. LED indication lamps - 3 Nos. Wiring & Accessories: Internal wiring: 6-16 sq.mm PVC insulated FRLSH copper wire with proper termination & crimped lugs. Cable lugs, ferrules, gland plates, earthing terminals supplied & installed. Adequate ventilation with dust-proof louvers. Panel frame and all metallic parts properly earthed. Testing & Commissioning: Functional checks, insulation resistance tests, continuity tests, protection setting verification, and site acceptance testing (SAT) as per Engineer-in-Charge instructions. Design Considerations: Outdoor ambient temperature 0-50°C, relative humidity up to 95%. Clear labeling of all switches, MCCBs, meters, busbars, and indicators. All materials, hardware and fittinwith voltmeter, ammeter, selector switch, CTs, control fuses & LED indicators. Control & Metering: Digital Voltmeter with selector switch. KWH Energy meter with CTs of suitable rating. LED indication lamps - 3 Nos. Wiring & Accessories: Internal wiring: 6-16 sq.mm PVC insulated FRLSH copper wire with proper termination & crimped lugs. Cable lugs, ferrules, gland plates, earthing terminals supplied & installed. Adequate ventilation with dust-proof louvers. Panel frame and all metallic parts properly earthed. Testing & Commissioning: Functional checks, insulation resistance tests, continuity tests, protection setting verification, and site acceptance testing (SAT) as per Engineer-in-Charge instructions. Clear labeling of all switches, MCCBs, meters, busbars, and indicators. All materials, hardware and fittings supplied as required for complete and safe operation.The drawing would be submitted by the contractor and approved by competent authority. the panel has to built & inspected in OEM factory. Inspection has to be carried out in presence of Rly's authorized representative. the control panel should be designed and manufactured by the CPRI and ISI.ISO approved manufacturer. | — | — | — | 4,79,680 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of floor mounted, indoor type, cubicle pattern, double door LT Panel Board fabricated from CRCA sheet steel of minimum 2.0 mm thickness for structure and 1.6 mm thickness for doors/covers, dust and vermin proof, duly powder coated after proper surface treatment, suitable for operation on 415 Volts, 3 Phase, 4 Wire, 50 Hz AC supply, complete with suitably rated aluminium/copper busbars, neutral bus, earth bus, interconnections, cable alleys, gland plates, danger notice plates, engraved identification labels and all standard accessories. The panel shall be complete with following switchgears: i) 250 Amps, 4 Pole MCCB - 01 No. ii) 125 Amps, 4 Pole MCCB - 02 Nos. iii) 63 Amps, 4 Pole MCCB - 02 Nos. iv) 32 Amps, 4 Pole MCCB - 03 Nos. All MCCBs shall be of suitable breaking capacity, thermal magnetic type with adjustable trip settings, conforming to relevant IS/IEC standards. The panel shall include internal wiring, control wiring, busbar sleeving, earthing terminals and provision for cable termination complete. The work includes supply, assembly, wiring, installation, testing and commissioning of the LT panel board complete in all respects as per approved drawing, site requirement and direction of Engineer-in-Charge. The panel should be completed with voltmeter, ammeter, selector switch, CTs, control fuses & LED indicators. Control & Metering: Digital Voltmeter with selector switch. KWH Energy meter with CTs of suitable rating. LED indication lamps - 3 Nos. Wiring & Accessories: Internal wiring: 6-16 sq.mm PVC insulated FRLSH copper wire with proper termination & crimped lugs. Cable lugs, ferrules, gland plates, earthing terminals supplied & installed. Adequate ventilation with dust-proof louvers. Panel frame and all metallic parts properly earthed. Testing & Commissioning: Functional checks, insulation resistance tests, continuity tests, protection setting verification, and site acceptance testing (SAT) as per Engineer-in-Charge instructions. Design Considerations: Outdoor ambient temperature 0-50°C, relative humidity up to 95%. Clear labeling of all switches, MCCBs, meters, busbars, and indicators. All materials, hardware and fittinwith voltmeter, ammeter, selector switch, CTs, control fuses & LED indicators. Control & Metering: Digital Voltmeter with selector switch. KWH Energy meter with CTs of suitable rating. LED indication lamps - 3 Nos. Wiring & Accessories: Internal wiring: 6-16 sq.mm PVC insulated FRLSH copper wire with proper termination & crimped lugs. Cable lugs, ferrules, gland plates, earthing terminals supplied & installed. Adequate ventilation with dust-proof louvers. Panel frame and all metallic parts properly earthed. Testing & Commissioning: Functional checks, insulation resistance tests, continuity tests, protection setting verification, and site acceptance testing (SAT) as per Engineer-in-Charge instructions. Clear labeling of all switches, MCCBs, meters, busbars, and indicators. All materials, hardware and fittings supplied as required for complete and safe operation.The drawing would be submitted by the contractor and approved by competent authority. the panel has to built & inspected in OEM factory. Inspection has to be carried out in presence of Rly's authorized representative. the control panel should be designed and manufactured by the CPRI and ISI.ISO approved manufacturer. | — | — | — | 1,75,220 | |
| — | 100.00 | — | — | ||
| Supply of materials and wiring of light point through concealed wiring by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire and modular type 6 amps controlling switch(with indicator type) to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface. | — | — | — | 38,948 | |
| — | 50.00 | — | — | ||
| Supply of materials and wiring of fan point/ exhaust fan point through concealed wiring by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire and modular type 6 amps controlling switch(with fan marking) and module type step fan regulator of 100 W to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface. | — | — | — | 23,791.5 | |
| — | 10.00 | — | — | ||
| Supply,fitting,fixing,testing and commissioning of 300 mm sweep wall bracket fan. All consumables regarding fixing arrangement will be supplied by the contractor as per the direction of engineer incharge at site. | — | — | — | 8,853.9 | |
| — | 1.00 | — | — | ||
| Providing and laying cement concrete foundation for DG Set of size 1.65 m x 3.70 m x 0.30 m using cement concrete in proportion 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate/chips), including dressing and leveling of foundation bed, centering/shuttering if required, mixing, laying, compacting, curing, finishing complete, including all labour, tools & plants, carriage, lead and lift, and all consumables required for execution of work as per approved drawing and direction of Engineer-in-Charge at site. Contractor shall arrange all materials including cement, sand, stone chips/aggregate and other consumables complete for proper execution of work. | — | — | — | 8,490.36 | |
| — | 15.00 | — | — | ||
| Supply, installation, testing and commissioning of IP-65 protected LED Bollard / Post Top Garden Light fitting suitable for outdoor application in parks, gardens, pathways and heritage locations, complete with pressure die-cast aluminium powder coated housing, UV stabilized polycarbonate diffuser, high efficiency LED module, integral electronic driver, surge protection, warm white LED output (3000K), operating on 230V AC, 50 Hz supply, having minimum 20 Watt LED system wattage, complete with all accessories, hardware, foundation bolts, connection terminals, internal wiring, suitable mounting arrangement and making proper connection as required at site. The fitting shall be of approved make such as Crompton Cat. No. LPTH-20-WW or equivalent model of Philips / Havells / Bajaj having IP-65 protection, die-cast housing and suitable for decorative landscape illumination. | — | — | — | 1,32,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
EL-LM-26-27-03.final_2.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .