| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-AOC 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹44.1 L+₹7.2 L (19.4%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹47.6 L+₹10.7 L (28.8%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | Rejected-Technical OPP SHRI NAVNIKETAN H S SCHOOL CHHOLA KANCHI BHOPAL M P | BHOPAL | MADHYA PRADESH | 462010 | - | Rejected-Technical Cost of Tender Documents not submitted | |
| 5 | Rejected-Technical | - | Rejected-Technical not enlisted in requisite category |
Tender Value
₹44.9 L
EMD Value
₹89,800
Closing Date
30 Aug 2021, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
DAY TO DAY MAINT OF EM SERVICES AND REPAIR MAINT OF INTERNAL ELECTRIFICATION AND FIXTURES TO CERTAIN OFFRS JCOS OR MD ACCN AT BAIRAGARH UNDER GE BHOPAL
2021_MES_460793_1
8802/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
BHOPAL
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE BHOPAL
₹89,800
Yes
25 Oct 2021
17 Jul 2021
1 Sept 2021
17 Jul 2021
30 Aug 2021
17 Aug 2021
Amount
NOTE: - (i) The works/items given below are for attending day to day complaints (of int. electricfication, fans, geysers, etc) by deploying sufficient skilled trades men/materials and making functional the complaint. (ii) The quoted rate deems to include for all minor expenses required for making the complaint functional. (iii) The trades man shall report to E/M complaint cell Bairagarh daily at 8.30 am to take complaints from concren JE E/M. The complaint must be attended on same day in stuiplate time period by providing material required and by deploying sufficient manpower by the contractor. The complaint slip duly signed by the user shall be returned back at the complaint cell with proper feed back in the evening. (iv) The tradesman deployed for work shall wear proper uniform with full shirt and full pant with their names & contractors name on the uniform. Colour code of uniform will be decided by Engineer-in-charge.
Taking down carefully existing point wiring (any type viz. aluminum or copper) with wooden batten/surface PVC conduit (with its fittings)/PVC casing-capping or any other type for light, fan, power point (including switch, socket, ceiling rose, etc.) and making good disturbed surface of wall/ceiling to match with existing surface after necessary rewiring complete all as specified and directed.
M&L for point wiring for one light / fan / bell point/ one 3 pin 5 Amp socket outlet on independent board with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in & including non metallic rigid PVC conduit (ISI marked) medium grade not less than 20mm diameter with all conduit accessories in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 (except on ceiling for fan point only, surface casing capping will be used in lieu of concealed PVC conduit) including one run of 1.5 sqmm copper conductor FRLS as earth continuity wire connected to common earth dolly, sunk sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. [Make of Cable : Polycab/ L&T/ Havells] Note :(i) Wiring to be done as per approved colour code in IE rule. (ii) Rate includes chase cutting for concealed wiring.
All as per item No. 2.00 here-in-before but for one light point controlled by two 2 way switches, with FRLS cables of 1.5 sqmm complete all as specified and directed.
All as per BOQ item No.2.00 above, one three pin socket outlet 5 Amp, controlled by one switch on same board with other switches complete all as specified and directed.
All as per item No. 2.00 here-in-before but wiring with 2.5 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
All as per item No. 2.00 here -in- before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
M&L for point wiring for one light / fan / bell point/one 3 pin 5 Amp socket outlet on independent board with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in existing concealed/surface conduit including one run of 1.5 sqmm copper conductor FRLS as earth continuity wire connected to common earth dolly by suitable lugs and 3mm thick laminated hylum sheet cover including taking old point wiring (any type without conduit) complete all as specified and directed. [Make of Cable : Polycab/ L&T/ Havells] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No. 7.00 above, but for one light point controlled by two 2 way switches complete all as specified and directed.
All as per BOQ item No.7.00 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per BOQ item No. 7.00 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination on independent board and provision of 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
All as per item 7.00 herein before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
M&L for point wiring for one light / fan / bell point/one 3 pin 5 Amp socket outlet on independent board with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLS cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed FRLS copper wire, ISI marked of green colour for continous earth, including sunken box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted with two coated of aluminium paint on internal surface and two coat of anti corrosive paint over external surface, including laminated hylum sheet cover, ISI marked of Make" Hylem" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per arroved colour code. Make of Cable : Polycab/ L&T/ Havells
All as per item 12.00 herein before One light point controlled by two 2-way switches.
All as per BOQ item No.12.00 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per item 12.00 herein before but wiring with 2.5 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
All as per item 12.00 herein before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Switch piano, flush type, single pole, two way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Socket outlet multipurpose having provision for 2 & 3 pin, 6 Amp flush type, 240 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in repairs switch socket combination outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, piano flush type, 230 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/ LEGRAND/ HAVELLS as approved by GE]
Supply and replacement of 3 pin plug top AC-230 v 15 Amp. complete all as specified and directed. Make : Anchor/ L&T/Havells
Supply and replacement of PVC insulated PVC sheathed, flexible circular cable 3 core, 2.5 Sqmm strandered copper conductor AC 230 V complete all as specified and directed. Make Havells/ Palza/ Polycab/Anchor
Supply and replacement of PVC insulated PVC sheathed, flexible circular cable 3 core, 1 Sqmm strandered copper conductor AC 230 V complete all as specified and directed. Make Havells/ Palza/ Polycab/Anchor
Dismantling geyser of any capacity and of any description, M&L for cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet, overflow, geyser element, thermostat, U assembly etc. with brush & cleaning rods and using and circulating concentrated de-scaling solution mixed with water in suitable proportion till the complete deposits/scale is removed and approved by the Engineer-in-Charge, fixing the serviceable parts in position, replacing the unserviceable parts, setting insulation properly as required, reassembling the complete geyser after cleaning, fixing & installation of the geyser in position and its testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. NOTE:- (i) De-scaling chemical shall be concentrated HCL of make as approved by GE. (ii) The quoted rates includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts will be measured and paid for separately under appropriate item of BOQ.
Supply and fixing the following spares of geyser in repair and testing after replacing the defective part for proper functioning of gyser complete all as specified and directed.
Thermostat ISI marked Make : Danfoss / Ranco / Indfoss
Triangle Heating element 1.5 KW, ISI marked Make : Bajaj / Usha/Theta
Triangle Heating element 2 KW, ISI marked Make : Bajaj / Usha/Theta
Indicator lamp with flexibe copper wire of suitable size Red/Green
Round Heating element 1.5 KW, ISI marked Make : Bajaj / Usha/Theta
Round Heating element 2 KW, ISI marked Make : Bajaj / Usha/Theta
PVC Connection with steel reinforced pipe for hot water connection of Size 18" x 1/2" including rubber washers.
S&F in repairs laminated hylum sheet cover, ISI marked of Make" Hylem" cut with grooves for mounting of fittings like switches, sockets, fan regulators etc. including fixing in location with new galvanised screw and cup washer complete all as specified and directed of following sizes :
11 x 13 inches
9 x 11 inches
5 x 8 inches
5 x 5 inches
Taking down old ceiling fan/Exhaust fans/Wall mounting fan of any cap/sweep after disconnecting the electric supply from any site, checking for its electrical defect and opening fans for checking of mechanical defect after dismentlling of fan, carried out repair/over hauling including removing dust and grease, and cleaning of internal mechanical parts of fan with kerosene oil, checking of alignment of shaft, oiling and greasing, checking of worn out bearing and other defective parts, winding, condenser etc and re-assembling, and connecting/refixing of fans in its original position by providing new GI nut bolt, lock washer and lock/split pin complete all as specified and directed by Engr-in-charge. NOTE: (i) Rewinding and replacement of defective parts, Painting etc shall be measured and paid seperately
S&F the following new parts suitable for ceiling fan, exhaust fans, wall mounting fans of any description, any sweep as repaired under under serial No. 62.00 of BOQ complete all as specified and directed. :- NOTE:-The new parts shall be suitable to match with the existing.
Ball Bearing No 6201 (set of two) [Make:SKF/NBC/FAG as approved by GE]
Ball Bearing No 6202 (set of two) [Make:SKF/NBC/FAG as approved by GE]
Condenser 2.5 mfd [Make: Epcos/Tibcon as approved by GE]
Condenser 4.0 mfd [Make: Epcos/Tibcon as approved by GE]
M&L for rewinding of ceiling fan of sweep 1200 mm with suitable gauge copper winding wire (super enamelled) including all insulating material after necessary heat varnishing, testing, etc. complete all as specified and directed.
M&L for rewinding of exhaust fan of 280/300 mm, 1400 RPM with suitable gauge copper winding wire (super enamelled) including all insulating material after necessary heat varnishing, testing, etc. complete all as specified and directed.
M&L for Taking out old led tube /fitting batten18/ 20/21/22 watt , 220 volt, 50 HZ by changing diod and connected accessoories and refixing in old position complete all as specified and directed.
S&F polycarbonate Switch piano flush button, single pole one way 15 Amp, 240 volt, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F ceiling fan regulator electronic steped type 240 V, AC 50 Hz single pole, 100 watts flush type complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings with & including LED lamp white 9 watt retrofit, 230 volts complete all as specified and directed. [MAKE FOR HOLDER:-ANCHOR (PENTA PC series)/ LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE] & LAMP : BAJAJ/PHILIPS/SYSKA]
S&F buzzer, Ding Dong type, electric, single phase, 240 volt, AC complete all as specified and as directed. [MAKE:-ANCHOR / LEADER/ LEGRAND /HAVELLS as approved by GE]
S&F Bell push, flush type, 6 Amp piano type, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Bell, Ding Dong type, electric, single phase, 240 volt, AC complete all as specified and as directed. [MAKE:-ANCHOR / LEADER/ LEGRAND /HAVELLS as approved by GE]
Taking down unserviceable sub main wiring including service connections, of any size and any description including conduit pipe complete all as specified and directed.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 25mm external diameter and PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells/Polycab as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 25mm external diameter and PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells/ Polycab as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 10 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 25mm external diameter and PVC insulated stranded copper conductor of 10 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells/ Polycab as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 10.0 sqmm cable, one run of 10.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 4.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed by EIC. Make of Cable : V-MARC/ Plaza/ Havells/ Polycab as approved by GE
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 6.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed by EIC. Make of Cable : V-MARC/ Plaza/ Havells/ Polycab as approved by GE
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 10.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed by EIC. Make of Cable : V-MARC/ Plaza/ Havells/ Polycab as approved by GE
Taking down old unserviceable MCB DB of any size and capacity including wooden boards complete all as specified and directed.
S&F sheet metal enclosure for MCB, DB, TPN 415 Volts 200 amps rated busbar 4 way Double door factory made Conf to IS:13032 fabricated out of CRCA sheet not less than 1.2mm thick fitted with DIN channel , neutral link and 200 amp , 440 volt rated bus bar suitable for mounting 63/100 Amp Mccb.DB shall be semi glossy finished with epoxy polyster based powder paint sprayed (RAL 9003) and baked at high temperature with anti rust conditoning protection against corrosive atmosphere . IP 43 protection class . DB shall also be provided with lable marking indicating the incoming and outgoing circuit .complete all as specified and directed by Engr-in-charge.Make Legrand/ Seimens/ Schinder.
S&F sheet metal enclosure for MCB, DB, VTPN 415 Volts 200 amps rated busbar 4 way Double door ( Vertical DB ) factory made Conf to IS:13032 fabricated out of CRCA sheet not less than 1.2mm thick fitted with DIN channel , neutral link and 200 amp , 440 volt rated bus bar, 25 KA .DB shall be semi glossy finished with epoxy polyster based powder paint sprayed (RAL 9003) and baked at high temperature with anti rust conditoning protection against corrosive atmosphere . IP 43 protection class . DB shall also be provided with lable marking indicating the incoming and outgoing circuit .complete all as specified and directed by Engr-in-charge. Make Legrand/ Seimens/ Schinder/L&T
S&F MCCB TPN 100 Amps, 16 KA breaking capacity, including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F MCCB TPN 40 to 63 Amps, 10 KA breaking capacity, including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar 10 KA, 12 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar 10 KA, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar 16 KA, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar 16 KA, 2 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F in repair electronic ballast 1 x 36 watt, 240 V, 50 HZ. complete all as specified and directed. (Ballast replaced without taking down of fitting will be measured under this item) [MAKE: CG/Bajaj/ Philips as approved by GE]
S&F MCB SP, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 5 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F MCB SPN, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 5 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F in repair MCB TPN 40 to 63 Amps, 10 KA breaking capacity, including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F single pole and neutral enclosure with two pin and earth, plug and socket, suitable for single phase 240 V, complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, complete all as specified and as directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F in replacement LED 20/21Watt tube light fitting (T8 type) , including LED retrofit tube 20/21 W one side connection type, 240 v, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative patti suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :-Havells cat Part No. BS20WLED840SPCWH or equivalent in Philips/ Crompton/Bajaj (Titania LED tube with Regal batten LED) as approved by GE.
S&F in replacement LED tube light rod 20/21 Watt (reterofit type, T8 pattern, single side connection) 240 V, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, to be fixed in existing or new batten/ patti including taking down of existing tube light fitting and changing the wiring suitable for T8 LED retrofit lamp in existing tube light fitting complete all as specified & directed. Make :- Wipro / Havells/ Philips as approved by GE.
S&F in replacement LED tube Highly durable surface mounted LED batten constructed of fire retardant engineering grade extruded plastic and decorative end caps. 20/21 Watt (reterofit type, T8 pattern, single side connection) 240 V, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, to be fixed in existing or new batten including taking down of existing tube light fitting and changing the wiring suitable for T8 LED retrofit lamp in existing tube light fitting complete all as specified & directed. Make :- Wipro / Havells/ Philips as approved by GE.
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR-2009 Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade GI pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. NOTE :- (i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe medium grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
S&F GI tubing light grade 40 mm dia with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps including necessary nut,bolt and washer or for protection of GI wire, etc including taking down old rusted pipe complete all as specified and directed.
S&F GI tubing light grade 50 mm dia with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps including necessary nut,bolt and washer or for protection of GI wire, etc including taking down old rusted pipe complete all as specified and directed.
S&F GI tubing light grade 15 mm dia with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps including necessary nut,bolt and washer or for protection of GI wire, etc including taking down old rusted pipe complete all as specified and directed.
Supply and fixing earth continuity conductor or main earthing lead of 4 mm GI wire laid in pipe/ fixed to wall on batton or recess or chases or buried in ground or drawn in conduit / pipe or any other indicated situation for loop earthing etc including jointing by using suitable size lugs, GI nuts, bolts and washer complete and all as specified and directed.
Supply and fixing switch socket combination 5-in-1, 5A/15 Amps, 6 pin, 240 volts controlled by one switch, flush type complete and all as specified and directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F bulk head luminare weather proof, including one No. LED lamp 9W and connecting with copper flexible three core 23/0.0076 and all necessary fittings complete and all as specified and directed. Make: Bajaj/ Philips/Wipro/Crompton/Havells.
M&L for cutting PCC/floor/road for taking out/ laying of cable, GI earth wire etc in protection pipe and making good, including material as per existing after laying of pipe for cable protection, GI wire etc, size of trench not more than 0.30 x 0.30 m complete all as specified and directed.
Supply and fixing switch socket combination 5-in-1, 5A/15 Amps, 6 pin, 240 volts controlled by one switch, flush type, including taking out old unserviceable Switch socket combination complete and all as specified and directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/ HAVELLS as approved by GE]
S&F in replacement LED 9/10 Watt mirror tube light fitting intergated type, approx 2 feet, 240 V, PF > 0.90, colour Temp 6500 K, suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :-C&S /n Wipro/ Philips/ Crompton as approved by GE.
Supply, laying, fixing or passing through pipe, 1100 volt grade heavy duty cable with PVC insulated multi stranded alunimium conductor served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 10 Sqmm x 2 core nominal cross section in service connections in ulding taking down old cable complete all as specified and directed. [MAKE:- POLYCAB /HAVELLS INDIA LTD/ KEI/V-MARC as approved by GE]
Excavating in trenches, nott exceeding 1.5m wide and not exceeding 1.5m in depth for pole foundation, cable trench, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed. at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. [Note:-Compacted/punned thickness shall be measured & paid]
Supplying and laying sub class 'B' bricks (modular) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed
S&F in repair single phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V, 5-30 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) in existing position by providing wooden board wooden board first quality of size 250 mm x 300 mm, including making complete elctric connections complete all as specifed and directed. Make : Secure/HPL/ L&T Note : Old meter to be deposite in AGE E/M store.
S&F in repair Three phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V per phase , 5-30 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) in existing position by providing wooden board first quality of size 250 mm x 300 mm, including making complete elctric connections complete all as specifed and directed. Make : Secure/HPL/ L&T Note : Old meter to be deposite in AGE E/M store.
Supply and fixing in relacement of Panel light, square type 2 ftX 2ft of 36 W, color temperature 3500 - 4100 K, AC 220 -240 V, 50 Hz, High surge Protection 2.5 KV, ISI, Lumen>4000, working lifetime hour 50000 pc lens for better light distribution including nut, LED lamp, wire all connecting accessories complete all as specified and directed. Make: Philips/wipro/bajaj
Schedule of credit (calculation will be done off line) Rs. 170879.00
M/s VIKAS TRADERS
SHIV SHANKAR MISHRA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .