Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.9 LAccepted-AOC 143 ALLAHABADPUR GORAKHPUR | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | 273001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹34.9 L+₹12.90 (<0.01%)Rejected-Finance E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L2 | Rejected-Finance Not being lowest bidder | |
| 3 | L3₹34.9 L+₹52.98 (<0.01%)Rejected-Finance | L3 | Rejected-Finance Not being lowest bidder | |
| 4 | L4₹34.9 L+₹772.90 (0.02%)Rejected-Finance | L4 | Rejected-Finance Not being lowest bidder | |
| 5 | L5₹34.9 L+₹3,273.70 (0.09%)Rejected-Finance FLAT NO 101 UGF FRONT LHS RZ B 49 A GALLI NO 09 KAILASHPURI PALAM COLONY NEW DELHI 110045 | NEW DELHI | NEW DELHI | DELHI | 110045 | L5 | Rejected-Finance Not being lowest bidder |
Tender Value
Refer Docs
EMD Value
₹87,200
Closing Date
29 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
MANNING AND OPERATION OF MES INSTALLATIONS/PUMP HOUSES (NEW DILKUSHA, CAMPBELL LINE, NEW B.S. MARG AND OUTRAM LINE) IN THE AREA OF AGE E/M EXT (WS) UNDER GE E/M LUCKNOW
2021_MES_436517_1
GE/EM/LKO/EXT(WS)/T-01 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
334 days
Lucknow
Class D or above category d (v)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹87,200
Yes
21 Jun 2021
15 Apr 2021
31 May 2021
15 Apr 2021
29 May 2021
15 May 2021
60 days
Amount
Providing services for uninterrupted operation of pumping set installation with submersible/monoblock / centrifugal pump set, DG set (any capacity and type ) bleaching powder dozer and chloronome plant of any capacity and type situated at following locations by deploying one no of operator in each installation for each shift of 8 ( eight ) hours for three shift (for duration of 24 Hrs i.e. in three shifts) at each installation including minor repair / maintenance of each installation ,complete all as specified and directed by Engineer- in- Charge . (a) NEW DILKUSHA, PUMP HOUSE (b) CAMPBELL LINE PUMP HOUSE (c) NEW B.S. MARG PUMP HOUSE (d) OUTRAM LINE PUMP HOUSE Note :Total man power (4X3) =12 Nos of Operator, one operator in each installation in each shift (Total three shift) having passed ITI in trade Fitter / Mechanic or equivalent Army Qualification.
Notes :- Rates quoted by the contractor shall be inclusive for following item :- (i) Contractor shall provide tool kit comprising of following items - tongue testers/clamp meter -01 spanner set- 01 adjustable wrench-01, safety hand gloves and provided necessary T & P for General Maintanace and opertation . (ii) Contractor shall provided two set of uniform, Shoe with Name Plate , Mobile connection for each operator. (iii) The log sheets will be maintained by the contractor in each installations. Contractor shall provided Log book, Attendence Register,Plant running record book and rate quoted by the contractor shall deemed to included in his quoted rates . (iv) The site documents such as Log Sheet, Attendance Register etc will be checked daily by JE, weekly by Engineer-in-Charge and monthly by GE. (v)The contractor will be responsible for upkeep of the installations in neat and tidy conditions and in a presentable manner. The surrounding area of the installation will also be maintained neat and clean by removing grasses and other vegetation. (vi) All plant and machinery equipment and other items belonging to installation including safety of manpower employed shall be responsibility of the contractor.
Notes contd/--- (vii) Minor stores required should be provided by the contractor. (viii) Major stores required for ractification of complaint will be supplied by the demartment (ix) Contractor shall submit insurance cover of all the workers employed by him for 11 Month period. (x) The quoted rates shall include the upkeep of surrounding area of the plant out side periphery / installations including grass/shurb cutting & plantation of seasonal flowers to an area of entire installations. In case the contractor fails to upkeep of the installations, he shall be liable to penalty @ Rs500/- per day for not upkeep of the installations. (xi) Contractor shall submit Form 11 to establish the applicability of EPF of workmen duly signed by worker and contractor himself. EPF for all workers as applicable shall be taken into consideration and proper accounts for the same shall be opened and details of the payment of the contribution for the previous month shall be handed over to Engineer in Charge between 15th to 20th days of the current month and also submit the details of return filed alongwith each RAR as applicable.
Notes contd/--- (xii) The rate quoted for items of outsourcing shall not be less than minimum wages as notified by Government of India/ concerned State Government/ Local Body, whichever is higher and also not less than applicable rates for contribution of employee towards Employees Provident Fund (EPF),contribution towards Employees State Insurance Corporation (ESIC), contribution of Bonus and Labour Welfare Cess (LWC) as applicable under respective headings/ sub-items. In case the rates quoted are less than the prevailing rates, the bid will be treated as Non-Bonafide/Invalid, shall be disqualified and such bids will not be considered for acceptance. In such case, the lowest bidder shall be determined from amongst the valid/ bonafide bids only. The tender will be considered for financial evaluation only if the rates in Item No. 1 is found bonafied. (xiii) The GST is included in the rates quoted against all items. (xiv) Contractor is required to quote only upto two digits after decimal place (as per IS No. 2 : 1960) or otherwise it will be considered by rounding off to two digits after decimal place.
Notes contd/--- (xv) Contractor will not be allowed to execute the work by subletting or through power of attorney holder on his behalf to a third party/ another firm except sons/ daughters of proprietor/ partner/ Director and firm’s own employees, Director, Project Manager. This shall be subject to certain conditions, which will be prescribed in the NOT forming part of the tender documents. (xvi) Prior to commencement of electrical work/electrical component of works and other works as mentioned in BOQ, copy of valid Electrical License in the name of the contractor or copy of agreement with agency having valid Electrical License alongwith Agency’s Electrical License shall be submitted by the contractor to the Accepting Officer. In case contractor does not possess valid Electrical License and he intends to get such work executed through agency having valid Electrical License and with whom he has agreement prior approval of such agency shall be got done from HQ CWE Lucknow. Copy of License shall be kept on record by GE/AGE for further reference. (xvii) In addition, Supervisor for execution of electrical works/electrical component of works employed by the contractor shall possess Supervisor Certificate of Competency issued by concerned State Govt/Union Territory and the worker/tradesmen for execution of electrical works/electrical component of works shall hold necessary Permit issued by concerned State Govt/Union Territory. (xviii) Reference of Electrical License and details of Supervisor’s Certificate of Competency and permit of tradesman employed for execution of electrical work/electrical component of works shall be duly incorporated in the Works Diary and relevant site documents respectively for the whole period during which such works is executed. (xix) If the contractor fail to submit the License/permit necessary action as deemed fit shall be taken against the contractor.
Supply and Fixing including testing of sluice valve of size 150 mm bore 'ISI marked' both ends flanged and drilled cast iron body class PN-1 conforming to IS-14846/2000 complete with gun metal spindle including necessary nut bolts etc in and including taking down of old unservicable sluice valve with all fittings,complete all as specified and directed by Engineer-in-Charge. Note: For those sluice valves which are fixed with pillar of over head tank work involve such as breaking of RCC/lead flange joints will be deemed to be included in the quoted rates, contractor will also repair the demaged floor etc.to match with existing and Joints shall be measured & paid seperately.
Supply and fixing in repair (including taking down) connection and testing cast iron Non return valve(NRV) PN-1 flanged end suitable for 150mm dia ISI marked without bypass arrangement including Nut, bolts and all jointing material commissioning and testing complete all as specified and as directed by Engineer- in- Charge.
Supply only bleaching powder the chlorine intent form 35-40% chlorine powder or chromate lime, used for water treatment , complete all as specified and directed by Engineer-in-Charge.
Supply only high strength calcium based granular containing appropriate quantities of chlorination dipensates / corrosion inhibitors to prevent encrustation / scaling in distribution system in 45 / 50 Kg packing of approved and tested from Govt lab or equivalent testing agency (not more than 02 months old packing) , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing, connecting, testing and commissioning of MCCB 160 Amps, 415 volts AC 50Hz, 3 pole, breaking capacity 36 kA (adjustable type) including spreader terminals as in replacement complete all as specified and directed by Engineer-in- Charge. (Make : Legrand/L&T/Schnieder)
Supply and fixing, connecting, testing and commissioning of MCCB 125 Amps, 415 volts AC 50Hz, 3 pole, breaking capacity 16 kA (adjustable type) including spreader terminals as in replacement complete all as specified and directed by Engineer-in- Charge.(Make : Legrand/L&T/Schnieder)
Supply and fixing, connecting, testing and commissioning of MCCB 100 Amps, 415 volts AC 50Hz, 3 pole, breaking capacity 16 kA (adjustable type) including spreader terminals as in replacement complete all as specified and directed by Engineer-in- Charge.(Make : Legrand/L&T/Schnieder)
Supply and fixing as in replacement on load changeover switch pole 415 V, 50 cycles-100 Amp complete all as specified and directed by Engineer-in- Charge.(Make : Legrand/L&T/Schnieder)
Supply and fixing as in replacement MCB SPN capacity 32 amp, 'C' series , complete all as specified and directed by Engineer-in- Charge. (Make : Legrand/L&T/Schnieder)
Supply and fixing as in replacement MCB SP 6 to 32 Amps, 240 Volts of 'B' series to be housed in DBs and suitable size cable lugs to be fixed with MCBs , complete all as specified and directed by Engineer-in- Charge. (Make : Legrand/L&T/Schnieder)
Supply and fixing as in replacement distribution box epoxy powder coated ,SPN 8 way, 240 V, with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door, complete all as specified and directed by Engineer-in- Charge. (Make : Legrand/L&T/Schnieder)
Supply and fixing as in replacement distribution box epoxy powder coated ,SPN 4 way, 240 V, with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 complete all as specified and directed by Engineer-in- Charge. (Make : Legrand/L&T/Schnieder)
Supply only in replacement chequered rubber mat of size 2000 mm x 1000 mm x 12.5 mm ISI Marked , complete all as specified and as directed by Engineer- in- Charge. Make : Jyoti.
CREDIT SCHEDULE.
The items listed below from serial no. 17 to 27 pertain to Credit Schedule. Bidders have to quote their own rates based on their assessment. The contractors can visit site by prior appointment with concerned AGE to ascertain the condition of these items. The sum total of these credit items (Serial 17 to 27) will automatically be deducted from the sum total of items from Serial No. 1 to 16.
Old unsv sluice valve obtained from BOQ item Nos 2.
Old unsv NRV obtained from BOQ item Nos 3.
Old unserviceable MCCB 160 Amps obtained from BOQ Item No. 6.
Old unserviceable MCCB 125 Amps obtained from BOQ Item No. 7.
Old unserviceable MCCB 100 Amps obtained from BOQ Item No. 8.
Old unsv Changeover switch obtained from BOQ item No 9.
Old unserviceable MCB SPN/SP of any rating obtained from BOQ item Nos 10 and 11
Old unsv ammeter/voltmeter obtained from BOQ item Nos 12 and 13.
Old unserviceable MCB DB's of any type obtained from BOQ item No 14 and 15.
Old Unserviceable rubber Mat obtained from BOQ item No 16.
HIND CONSTRUCTIONS
Sanjai sales and services
Gupta Constructions
GUJRAL BUILDERS
DEV INFRATECH
M/s Sanjay and Sanjay
jay maa engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .