Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹9.9 L+₹71,560 (7.83%)Rejected-Finance NO 6 BAJANAI KOIL CROSS STREET CHATHIRAM PATTABIRAM CHENNAI 600 072 | CHENNAI | CHENNAI | TAMIL NADU | 600072 | L2 | Rejected-Finance Being 2nd Lowest | |
| 3 | L3₹10.0 L+₹84,321 (9.23%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest |
Tender Value
₹8.7 L
EMD Value
₹17,400
Closing Date
7 Jun 2021, 6:00 pmClosed
AGE I RD AVADI
AGE I RD AVADI CHENNAI 600054
SPECIAL REPAIRS TO REPLACEMENT OF WATER PIPE LINE FROM VARIOUS BORE WELLS TO UG SUMP IN TEST TRACK AREA AT CVRDE AVADI
2021_MES_422067_2
8353/E8
Open Tender
Civil Works
Item Rate
180 days
AVADI
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹17,400
Yes
26 Jun 2021
11 May 2021
12 Jun 2021
11 May 2021
7 Jun 2021
24 May 2021
11 May 2021 - 24 May 2021
Amount
Supply and laying Galvanised steel water tubing 20 mm bore medium grade confirming to IS-1239 (Part-I) including all required fittings such a bends, tee, short piece, connectors, elbow, reducers union, sockets etc, laid in trenches and fixed in wall, ceiling and floors complete including taking down old GI pipe all as specified & directed by Engineer-in-Charge.
Supply and laying Galvanised steel water tubing 25 mm bore medium grade confirming to IS-1239 (Part-I) including all required fittings such a bends, tee, short piece, connectors, elbow, reducers union, sockets etc, laid in trenches and fixed in wall, ceiling and floors complete including taking down old GI pipe all as specified & directed by Engineer-in-Charge.
Supply and laying Galvanised steel water tubing 50mm bore medium grade confirming to IS-1239 (Part-I) including all required fittings such a bends, tee, short piece, connectors, elbow, reducers union, sockets etc, laid in trenches and fixed in wall, ceiling and floors complete including taking down old GI pipe all as specified & directed by Engineer-in-Charge.
Supply and laying Galvanised steel water tubing 80mm bore medium grade confirming to IS-1239 (Part-I) including all required fittings such a bends, tee, short piece, connectors, elbow, reducers union, sockets etc, laid in trenches and fixed in wall, ceiling and floors complete including taking down old GI pipe all as specified & directed by Engineer-in-Charge.
Supply and laying Galvanised steel water tubing 100mm bore medium grade confirming to IS-1239 (Part-I) including all required fittings such a bends, tee, short piece, connectors, elbow, reducers union, sockets etc, laid in trenches and fixed in wall, ceiling and floors complete including taking down old GI pipe all as specified & directed by Engineer-in-Charge.
S&F Gun metal globe or gate valve 20 mm dia with iron wheel head screwed both ends for GI pipe and fixed ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F Gun metal globe or gate valve 25 mm dia with iron wheel head screwed both ends for GI pipe and fixed ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F Gun metal globe or gate valve 50 mm dia with iron wheel head screwed both ends for GI pipe and fixed ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply and fix Sluice valve PN 1:0 of 80mm dia bore flanged end complete with iron wheel head and stainless steel spindle ISI marked including necessary bolts and washers including taking down old sluice valve complete all as specifed and directed by Engineer-in-Charge.
Supply and fix Sluice valve PN 1:0 of 100mm dia bore flanged end complete with iron wheel head and stainless steel spindle ISI marked including necessary bolts and washers including taking down old sluice valve complete all as specifed and directed by Engineer-in-Charge.
M&L for excavation in trenches not exceeding 1.5 metres wide and not exceeding 1.5 metres deep in any type of soil and getting out including forming bottom surface to required level or slope complete all as specified and directed. Note : (i) All execavation to be carried out by manual only. (ii) The rates for all excavation items include: Clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30 cm girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area.
M&L for returning, filling in trenches in layers not exceeding 25cm including spreading, leveling and well ramming including watering complete all as specified and directed by Engr-in-charge.
M&L for removing surplus excavated soil to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5m high from the starting point all as specified and directed by Engr-in-Charge.
M&L for demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level ) complete all as specified and as directed by Engineer-in-Charge.
SHRI BALAJI CONSTRUCTIONS
K Kumar Construction
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .