Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹4.9 Cr UNIT 4C 4TH FLOOR GOLDLINE BUSINESS CENTRE NEW LINK ROAD MALAD W MUMBAI 400 064 MAHARASHTRA | ₹4.9 Cr |
Tender Value
₹4.9 Cr
EMD Value
₹4.9 L
Closing Date
19 Apr 2025, 11:00 amClosed
Supply, Installation, Testing and Commissioning of Acoustic, Electrical incl ELV, HVAC, Fire Fighting and allied works of Theatre and Recording Studio located at 4th and 6th Floor of Phase II Building of NFDC at NFDC FD Complex, 24, Dr Deshmukh Marg, Mumbai 26
NBCC/RBG-MAH/NFDC/NIT/15/2025
NBCC/RBG-MAH/NFDC/NIT/15/2025
Open Tender-Domestic
Miscellaneous
Mumbai, Maharashtra
₹11,800
₹4.9 L
7 May 2025
10 Apr 2025
19 Apr 2025
19 Apr 2025
30 Apr 2025
Name of Work : - Acoustic, Electrical, HVAC, Fire Fighting and allied works for the theatre /recording Studio of Phase-II building
at NFDC at NFDC-FD Complex, 24, Dr. Gopalrao Deshmukh Marg, Mumbai- 400 026.
BILL OF QUANTITY
Sr. No. Description Unit Qty Rate Amount
A 4'Th Floor- Theatre
1 Inner Acoustic Wall (Refer Acoustic Drawings)
2 Construction of Framework maintaining Air gap of 2 inches, using 4" x 2' Aluminium section fixed equidistantly at 600 SqMt 333 13,200.00 43,95,600.00
mm c-to-c taking support from Wall
Fixing wiremesh to the frame from the wall Side and fill the frame with Rockwool 100 mm and 64 kg/m3 density friction
Fxing water proof 18 mm Plywood over the frame.
Fixing 2 mm Techsound over the PLy with sutable adhesive
Fixing 2 layers of 12 mm Gyproc Gypsum Board.
Fixing Frame of ply section 25mm X 100 mm placed euidistantly 600 mm vertiall & Horizontally
fixing 9 mm Acoustic Sheet Tranquill make or equivalent acheiving NRC of 0.9
NOTE- All wooden material should be Treated to be termitie resistant
3 Providing wooden frame using sal wood section of 50mm X 50 mm size placed 600 mm c to c and supported by SqMt 168 9,480.00 15,92,640.00
shock absorbers rubber blocks
Friction fitted Rockwool 50 mm thick and 94 or more kg/m3 densilty
Fixing 18 mm Ply over the Frame
NOTE- All wooden material should be Treated to termitie resistant
4 Supply and installtion of Stepped Flooring with ISI MR grade 18 mm Ply and robust stable supporting structure. SqMt 96 11,000.00 10,56,000.00
Each step shall be raised by 150 mm starting from Zero level as indicated in the Drawing.
NOTE- All wooden material should be Treated to be termitie resistant
Providing & Fixing in position,Carpet more than 800+ gsm,made with100%stain proof fibres of approved make along SqMt 72 2,850.00 2,05,200.00
5 with 5 mm under lay as per Architectural & Acoustical Design & Instructions & Complete in all aspects including al
lmaterials labour,finishing etc
6 All the stepped or raised areas shal be finished with Wood finish Interlocking SPC Laminate flooring SqMt 96 2,850.00 2,73,600.00
4mm SPC flooring, Size 1220 x 183 mm , Top wear Layer 0.3 to 0.5 mm ensuring Heat stabilty std EN434, Peeling
Strength as per EN431,Abrasion resistance as per EN660-2
BILL OF QUANTITY
Sr. No. Description Unit Qty Rate Amount
7 Supply and Providing Isolation layer on the Ceiling by constructing framework using Isoclip fixed to ceiling and GI SqMt 168 9,000.00 15,12,000.00
channel threaded through the Isoclip.
Providing Friction fitted Rockwool 25 mm and 64 Kg/m3 density in the Gap
Providing alyer of 12 mm Ply , 2 mm Techsound MLV sheet and two layers of 12 mm Gypsum followd by Dark Grey
colour paint finish
NOTE- All wooden material should be Treated to be termitie resistant
8 Providing Black Rockfon Ceiling Tiles 2t X 2ft with framing having Excellent sound control with NRC up to 0.95 and SqMt 168 4,700.00 7,89,600.00
CAC up to 35, ensuring optimal acoustic performance
Door (Refer Acoustic door Section Drawings)
9 Supply and Installtion of Double Leaf Acoustic Door with wooden all sides Stepped Frame with Provision of Heavy Sq Mt 10 56,900.00 5,69,000.00
Duty Door Closers, Hinges . The Acoustic Door should provide STC value of 50+ and should be equipped with
effective Door Seals. The Door leafs shall have Vineer finish with suitable Polish
NOTE- All wooden material should be Treated to be termitie resistant
Theatre Seating for Audience
10 Supply & Installtion of Push Back cinema chair with ppcp cup holder arms, moulded pu foam in seat & back( density of Nos 78 9,480.00 7,39,440.00
foam 50+) metal powder coating side frame in ms heavy gauge, with push back roller mechanism arm to arm centre
11 Supply and Installation of Specially Designed Table of Size 10 ft X 3 ft with Adjustable Monitor Mounts 2 Nos, Nos 1 1,42,000.00 1,42,000.00
Provision for Clean Cable Dressing
Supply and Installtion of Chair eithergonomic features, including: Nos 4 42,500.00 1,70,000.00
SpineForm™ Back Technology: Aligns with the natural S-curve of your spine to promote healthy posture.
Suspended Waterfall3D Seat: Features a double-layer seat with shock absorption to alleviate pressure on the coccyx,
and a waterfall design to enhance blood circulation to the lower limbs.
Max2D Headrest: Adjustable in height and angle to provide optimal neck support.
12 Followup3D Armrests: Soft PVC-padded armrests that adjust with your movements, ensuring continuous arm support
even when reclining.
Wire-Controlled GravitySensing Recline: Allows easy adjustment of seat recline, height, and depth with a one-click
button control, featuring GravitySensing technology for a seamless reclining experience.
BILL OF QUANTITY
Sr. No. Description Unit Qty Rate Amount
B 5Th Floor- Edit Rooms
Acoustic Wall (Refer Acoustic Drawings)
Construction of Framework using 2" GI Stud section fixed equidistantly at 600 mm c-to-c taking into GI C channel SqMt 97.21 7,590.00 7,37,838.29
fixed at Ceiling & FLoor
Fill the frame with Rockwool 50 mm and 64 kg/m3 density friction fitted.
Fxing water proof 18 mm Plywood over the frame.
Fixing 2 mm Techsound over the PLy with sutable adhesive
13 Fixing layers of 12 mm Gyproc Gypsum Board on inner & Outer sideFixing
Frame of ply section 25mm X 100 mm placed euidistantly 600 mm vertiall & Horizontally
fixing 9 mm Acoustic Sheet Tranquill make or equivalent acheiving NRC of 0.9
NOTE- All wooden material should be Treated to be termitie resistant
14 Providing Acoustic Hanging Panel made of Tranquill 9 Mm Acoustic Sheet fied on 12 MM Ply frame SqMt 35 5,200.00 1,82,000.00
15 SITC of Interlocking wooden Laminate or SPC fltiles 10 mm thick SqMt 30 2,300.00 69,000.00
16 SITC of Edit Desk size 7 ft X 3 ft Duco Paint made from 18 mm Ply with shelves on both sides. Provision Monitor No 2 56,900.00 1,13,800.00
Mounts with Height adjustments, PDU and cable Raceway at the back side
5Th Floor- Projector and Server Room
Raised Flooring
SITC of Raise flooring with Panels od size 600 X 600X33 mm, SqMt 60 3,600.00 2,16,000.00
Pedestal Set Assembly -Base 200mm FFH / Head 16mm Stud 3mm Head
Stringer C Type
17 Cconcentrated load capcity in the ranges 350 to 400 kgs and Ultimate Concentrate Load capacity of 950 Kgs with
pedestal height of 450 mm
Fixing of 25 mm Nitrile rubber sheet on the floor over PCC
18 SITC of Projector Mounting Table as per design with Load bearing capacity of 150 Kgs, provision for motorised Height Set 1 95,000.00 95,000.00
BILL OF QUANTITY
Sr. No. Description Unit Qty Rate Amount
19 SITC of Port Window Frame & Glass for Projection 5 ft X 4 Ft No 1 95,000.00 95,000.00
1. Low-Iron Glass (Ultra-Clear Glass)
•Regular glass has a greenish tint due to iron content, which can distort the projected image.
•Low-iron glass eliminates this tint, ensuring maximum light transmission and true color representation.
2. Anti-Reflective (AR) Coated Glass
•Reduces reflections and glare, which can degrade the image quality.
•Increases light transmission, allowing more of the projected image to pass through without distortion.
3. Tempered or Laminated Glass
•Ensures durability and safety.
•Withstands heat generated by the projector without warping or cracking.
D 6Th Floor- Immersive Theatre
Inner Acoustic Wall (Refer Acoustic Drawings)
20 Supply and installation of 25mmthk Woodwool Board directly onthe wall using Screw andfinished with 9mm thk SqMt 358.46 7,100.00 25,45,046.47
AcousticNon woven Board.
21 Supply and installtion of Surface finishing of Floor with PCC removing all undulations followed by Epoxy or PU SqMt 192 5,700.00 10,94,400.00
Flooring as per Architects requirement
23 Supply and installation of Open Ceiling with POP Surface finish and dark grey Paint SqMt 192 700.00 1,34,400.00
Door (Refer Acoustic door Section Drawings)
Double Leaf Acoustic Door with wooden all sides Stepped Frame with Provision of Heavy Duty Door Closers, Hinges . Nos 5 57,000.00 2,85,000.00
The Acoustic Door should provide STC value of 50+ and should be equipped with effective Door Seals. The Door leafs
24 shall have Vineer finish with suitable Polish
NOTE- All wooden material should be Treated to be termitie resistant
Control Desk (located on 7th floor control room)
25 Supply & installtion of Specially Designed Table of Size 7 ft X 3 ft with Adjustable Monitor Mounts, Clean Cable Nos 1 1,42,300.00 1,42,300.00
BILL OF QUANTITY
Sr. No. Description Unit Qty Rate Amount
Chair eithergonomic features, including: Nos 4 38,000.00 1,52,000.00
SpineForm™ Back Technology: Aligns with the natural S-curve of your spine to promote healthy posture.
Suspended Waterfall3D Seat: Features a double-layer seat with shock absorption to alleviate pressure on the coccyx,
and a waterfall design to enhance blood circulation to the lower limbs.
Max2D Headrest: Adjustable in height and angle to provide optimal neck support.
26 Followup3D Armrests: Soft PVC-padded armrests that adjust with your movements, ensuring continuous arm support
even when reclining.
Wire-Controlled GravitySensing Recline: Allows easy adjustment of seat recline, height, and depth with a one-click
button control, featuring GravitySensing technology for a seamless reclining experience.
27 View through Acoustical Window with Frame & Glass 10 ft X 6 ft No 1 1,89,700.00 1,89,700.00
E 6Th Floor- Audio Dubbing Studio (2 Nos)
Inner Acoustic Wall (Refer Acoustic Drawings)
Construction of Framework maintaining Air gap of 2 inches from the outer wall, using 2" GI Stud section fixed SqMt 314.96 12,300.00 38,74,042.75
equidistantly at 600 mm c-to-c taking into GI C channel fixed at Ceiling & FLoor
Fill the frame with Rockwool 50 mm and 64 kg/m3 density friction fitted.
Fxing water proof 18 mm Plywood over the frame.
Fixing 2 mm Techsound over the PLy with sutable adhesive
28 Fixing 2 layers of 12 mm Gyproc Gypsum Board
Fixing Frame of ply section 25mm X 100 mm placed euidistantly 600 mm vertiall & Horizontally
Fixing fabric wrapped Absorption pannels over the frame
NOTE- All wooden material should be Treated to be termitie resistant
Supply & Installation of Floating floor created by SqMt 17 7,600.00 1,29,200.00
Providing wooden frame using sal wood section of 50mm X 50 mm size placed 600 mm ctoc and supported by shock
absorbers rubber blocks
Friction fitted Rockwool 50 mm thick and 94 or more kg/m3 densilty
Fixing 18 mm Ply over the Frame
NOTE- All wooden material should be Treated to be termitie resistant
30 SITC of Wood finish Interlocking SPC Laminate flooring 4mm SPC flooring, Size 1220 x 183 mm , Top wear Layer 0.3 SqMt 17 2,800.00 47,600.00
to 0.5 mm ensuring Heat stabilty std EN434, Peeling Strength as per EN431,Abrasion resistance as per EN660-2
BILL OF QUANTITY
Sr. No. Description Unit Qty Rate Amount
Providing and installation of Isolation layer on the Ceiling by constructing framework using Isoclip fixed to ceiling and SqMt 17 9,500.00 1,61,500.00
GI channel threaded through the Isoclip.
Providing Friction fitted Rockwool 25 mm and 64 Kg/m3 density in the Gap
Providing layer of 12 mm Ply , 2 mm Techsound MLV sheet and two layers of 12 mm Gypsum,
9 mm Tranquill acoustic Sheet
NOTE- All wooden material should be Treated to be termitie resistant
32 Providing and installation of Diffuser Panels to be suspended from the Ceiling SqMt 3 5,700.00 17,100.00
Door (Refer Acoustic door Section Drawings)
33 Supply & installation of Single Leaf Acoustic Door with wooden all sides Stepped Frame with Provision of Heavy Duty Nos 9 31,700.00 2,85,300.00
Door Closers, Hinges . The Acoustic Door should provide STC value of 50+ and should be equipped with effective
Door Seals. The Door leafs shall have Vineer finish with suitable Polish. The expeted STC to be achieved would be
NOTE- All wooden material should be Treated to be termitie resistant
Supply , Installation &Testing of Typical Sound Engineer Desk for recording studio as per Design with provisoin of
Shelves for racking mounting equipment on left ^& Right Side
34 The Depth of the table shall be 3 to 3.5 feet . The Rack portion of the Table shall be tilted on both sides fo easy acces
of the equipments paced in it. There shall be provison f PDU and Cable raceways at the Back to for layin the Cables
from an to the equipments on the Desk. The Desk shall be Duco painted
35 Suuply & installation of Chair eithergonomic features, including: Nos 1 42,700.00 42,700.00
SpineForm™ Back Technology: Aligns with the natural S-curve of your spine to promote healthy posture.
Suspended Waterfall3D Seat: Features a double-layer seat with shock absorption to alleviate pressure on the coccyx,
and a waterfall design to enhance blood circulation to the lower limbs.
Max2D Headrest: Adjustable in height and angle to provide optimal neck support.
Followup3D Armrests: Soft PVC-padded armrests that adjust with your movements, ensuring continuous arm support
even when reclining.
Wire-Controlled GravitySensing Recline: Allows easy adjustment of seat recline, height, and depth with a one-click
button control, featuring GravitySensing technology for a seamless reclining experience.
F 6Th Floor- Edit + DI Room
Acoustic Wall (Refer Acoustic Drawings)
BILL OF QUANTITY
Sr. No. Description Unit Qty Rate Amount
36 Construction of Framework using 2" GI Stud section fixed equidistantly at 600 mm c-to-c taking into GI C channel SqMt 51.21 7,500.00 3,84,061.34
fixed at Ceiling & FLoor
Fill the frame with Rockwool 50 mm and 64 kg/m3 density friction fitted.
Fxing water proof 18 mm Plywood over the frame.
Fixing 2 mm Techsound over the PLy with sutable adhesive
Fixing layers of 12 mm Gyproc Gypsum Board on inner & Outer sideFixing
Frame of ply section 25mm X 100 mm placed euidistantly 600 mm vertiall & Horizontally
fixing 9 mm Acoustic Sheet Tranquill make or equivalent acheiving NRC of 0.9
NOTE- All wooden material should be Treated to be termitie resistant
37 Supply & installation of Fixing Frame of ply section 25mm X 100 mm placed equidistantly 600 mm vertiall & SqMt 24 5,200.00 1,24,800.00
fixing 9 mm Acoustic Sheet Tranquill make or equivalent acheiving NRC of 0.9
NOTE- All wooden material should be Treated to be termitie resistant
38 Supply & installation of Interlocking wooden Laminate tiles 10 mm thick SqMt 24 2,300.00 55,200.00
39 Control Desk
Supply Installation testing & Commissioning of Specially Designed Table of Size 2100 mm L X 1000 mm D x 700 Nos 1 1,42,300.00 1,42,300.00
mm H Adjustable Monitor Mounts 2 Nos, Provision for Clean Cable Dressing
41 Supply and installation of Chair eithergonomic features, including: Nos 2 42,600.00 85,200.00
SpineForm™ Back Technology: Aligns with the natural S-curve of your spine to promote healthy posture.
Suspended Waterfall3D Seat: Features a double-layer seat with shock absorption to alleviate pressure on the coccyx,
and a waterfall design to enhance blood circulation to the lower limbs.
Max2D Headrest: Adjustable in height and angle to provide optimal neck support.
Followup3D Armrests: Soft PVC-padded armrests that adjust with your movements, ensuring continuous arm support
even when reclining.
Wire-Controlled GravitySensing Recline: Allows easy adjustment of seat recline, height, and depth with a one-click
button control, featuring GravitySensing technology for a seamless reclining experience.
BILL OF QUANTITY
Sr. No. Description Unit Qty Rate Amount
G ELECTRICAL ITEMS
42 Supply & Installation Linear LED fixtures 1200 mm Length 28 W black Body Nos 200 2,850.00 5,70,000.00
SITC of Electrical Panels ( Reffer Annexure-B and Drawing of Panels)
LT Panles for floors along with Bus Bars, Switchgears, Volt/Amp meters, Energy meters, capicitors,with necessary Nos 4 3,79,000.00 15,16,000.00
Accessories as per Design.
44 SITC of UPS Panels for floors along with Bus Bars, Switchgears, Volt/Amp meters, Energy meters, capicitors,with Nos 1 5,74,000.00 5,74,000.00
necessary Accessories as per Design
45 SITC of INPUT /OUTPUT Isolator Boxes for UPS Nos 2 2,37,000.00 4,74,000.00
46 SITC of TAP Boxes with Switch gear for Tapping Power for the Exisiting Runner BUS Bars in the Building Nos 6 71,000.00 4,26,000.00
47 SITC of Electricals for Theatre & Immmersive Studio including Incomer Armoured cables, LT Panel ,DBs, TPN DBs, Job 1 14,23,000.00 15,00,000.00
4P-MCBs, 2P MCBs,32 Amp Industrial Switch Socket, 5/16 Amp Switch Sockets Asthetic Lighting for Theatre using
LED profiles,Flexible cabling from TPN DBs to Power points Industrial Sockets, Power Points
TPN 8 WAY, double door,considiting of
80 A 4P MCB - 1 No
63A DP MCB -3 Nos
20A SP MCB-12 Nos & 32A SP MCB-6 Nos
Incomer Cables from UPS- 50 Sqmm 4C Armouredb-120 MTR
Both side Cable Terrminations
Industrial Socket with MCB 32 AMP- 15 Nos
Switch Sockets 5/16 Amps -30 Nos
LED Lights for Indirect Lighting with Profiles & Driversin Theatre-100 Mtr
H SURVEILLANCE
49 SITC of 24-Port Gigabit Ethernet PoE+ Smart Switch with 2 SFP Ports (190W)/ Cloud Managed
50 SITC of SFP Modules Nos 10 9,400.00 94000
51 SITC of PC for Monitoring Nos 1 71,000.00 71000
52 SITC of Monitor TV 65 inches Nos 2 56,000.00 112000
SITC of 48-Port Gigabit Ethernet Smart Switch With 2 Dedicated & 2 Combo SFP Ports
BILL OF QUANTITY
Sr. No. Description Unit Qty Rate Amount
SITC of AX5400 4X4 Dual Band PoE Multi-Gig WiFi 6 Access Point & with 6 year cloud managed
SITC of 24-Port Gigabit Ethernet PoE+ Smart Switch with 2 SFP Ports (190W)/ Cloud Managed
56 SITC of Cat 6A Cable (305 Mtr Roll) Mtr 3250 55.00 1,78,750.00
57 SITC of SFP Module Nos 10 9,400.00 94,000.00
58 SITC of Fibre Cable for Switch to Switch Connnection Mtr 125 115.00 14,375.00
59 SITC of LIU 24 port ( 5th Floor) Fully Loade ( MOLEX) Nos 1 20,300.00 20,300.00
60 SITC of LIU6 port (4th, 6th, 7th Floor) Fully Loaded ( MOLEX) Nos 3 38,500.00 1,15,500.00
61 SITC of 1 mtr/3 mtr Fibre Patch Cord Nos 10 1,150.00 11,500.00
J HVAC WORK OF THEATRE
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable
Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed
inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor
based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable
foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even
at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz
AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP
at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5
BILL OF QUANTITY
Sr. No. Description Unit Qty Rate Amount
Supply and delivery at MDL site of Ceiling Suspended Double Skin Air Handling unit (AHU) with thermal break profile
and integral internal coaming, double skin panels minimum 43±2 mm thick fabricated out pre-plasticized 22 swg GSS
on outer side and plain 22swg GI on inner side with PUF insulation density not less than 38 kg/m3 sandwiched
between inner and outer sheet for comfort area. The AHU shall comprise of Fresh Air Module with G-4 filter and
volume control damper suitable for manual & motorised operation, Mixing Chamber, Pre-filter section with G-4 Filters,
Coil Section with Minimum 6 Row DX interleaved copper coil, DX Coil Fins to be provided with hydrauphilic coating
and insulated SS drain pan, Blower section with backward curve centrifugal DIDW blower and High Energy Efficient
(EFF1) motor with belt and pulley drive assembly & Variable Frequency Drive (VFD). Unit to be provided with Limit
switches for AHU doors, inspection lamps with fire proof Double Canvass connection (Fungal and Lint free) & anti
vibration pads complete as required. Selected model of AHU should be BMS compatible as per specification. The
AHU shall be designed considering Saline Environment condition. (Selected Model of AHU should be BMS Compatible
as per specfication).
Capacity : 6000 CFM (18.00 TR) & 70 mm Static Pressure
Capacity : 6000 CFM (18.00 TR) & 70 mm Static Pressure
Supply, Installation, Testing & Commissioning of AHU KIT for connection of VRF ODU with Third Party AHU
Supplying, erecting, testing and commissioning centralised programmable remote control panel (HMI) touch manager
controls minimum 16 system of 64 ODU's can be controlled and up to 992 IDU's can be individually mounted and
controlled indoor units having colour min 200mm size LCD touch panel, yearly schedule, power proportional
distribution function, temperature limitation, history function complete erected on wall integrated with provided
Providing vaccumising the airconditioner system to 200 micron and charging with R32 / R410A
refrigerant for AC unit.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates,
chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting,
drilling and welding complete erected at the position with necessary materials duly painted with one coat of red
oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
71 REFREGRENT PIPE
BILL OF QUANTITY
Sr. No. Description Unit Qty Rate Amount
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal
sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable
adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O
tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified
thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :(5.0
38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19
mm thick insulation
41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19
mm thick insulation
supply & installation of PVC piping complete with fittings, supports as per specifications and insulated with 9
mm thick closed cell elastomeric nitrile rubber insulation.
K ELECTRICAL SECTION
Supply, Installation, Testing & Commissioning of All control cables between indoor and
outdoor unit laid in PVC Piping and clamped.
79 Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper
conductor complete erected on wall/ ceiling complete as per specification.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100
79 V, 3 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided M 120 285.00 34,200.00
trench/ pipe as per specification.
80 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100
V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided M 20 1,050.00 21,000.00
trench/ pipe as per specification.
BILL OF QUANTITY
Sr. No. Description Unit Qty Rate Amount
81 LOW SIDE WORKS
82 Supply, Installation, Testing & Commissioning of Pre fabricated - Factory Fabricated Galvanised Sheet Steel of 180
GSM, Rectangular Ducting as per specification complete (as per approved make) with Tie rod supports, nut-bolts,
washer, neoprene gaskets duly installed. Leak Testing of ducts at site shall be carried out as per SMACNA standard
etc all complete as required
83 Thickness 0.63 mm sheet (24G) sqm 0 2,050.00 -
84 Thickness 0.80 mm sheet (22G) sqm 0 2,400.00 -
85 Thickness 1.00 mm sheet (20G) sqm 400 2,400.00 9,60,000.00
86 Thickness 1.25 mm sheet (18G) sqm 0 3,500.00 -
Supply, fabrication, installation and testing of flexible canvas connections constructed between
ductable unit/ventilation fans / dampers/ducting of suitable size with fire resist flexible double canvas sleeve complete.
88 Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene
rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications
89 Supplying, installing, testing and commissioning of Bird screen shall made out of 25 x 25 mm
2.5mm GI wire mesh inset with 0.8mm GI frame and bolted to the enclosure flange at 150mm center using 12mm MS sqm 1 4,900.00 4,900.00
brass bolts and nuts.
90 Grills & Diffusers -
91 Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium
volume control dampers with anti smudge ring & removable core.
92 Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume
control dampers with anti smudge ring & removable core.
93 Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium
volume control dampers as per specifications.
94 THERMAL, ACOUSTIC INSULATION & UNDERDECK WORKS
95 Supply, installation, testing and commissioning of 19 mm thick Duct Thermal insulation fire retardant , closed
cell structured factory laminated 7 mill glass cloth Nitrile insulation of density 40-60 kg/m3 shall be with two
coats of lag coating ( Anti-fungal & vapour barrier -5590 standard) wrapped with glass woven clothed surface For
Supply and return insulation.
96 Supply, installation, testing and commissioning of closed cell structure both side plain type 25mm thick nitrile
rubber insulation of density 40-60 kg/m3 for underdeck ceiling insulation with food grade adhesive and proper
fixing with required accessories etc. with two coats of lag coating ( Anti-fungal & vapour barrier -5590 standard)
over it.( For Below Terrace & Service Floor)
BILL OF QUANTITY
Sr. No. Description Unit Qty Rate Amount
97 VENTILATION SYSTEM
98 Supply, installation, testing and commissioning of Inline fans for exhaust and fresh air shall be complete with speed
control, louver shutter, suitable starter panel, rain protection louver, bird screen. Fans to be ring mounted on suitable
frame provided by AC Contractor. Power will be provided 5 ft away from fan and necessary wiring with plug will be
provided by AC contractor.
Starter panel shall be BMS compatible.
Exhaust and Frsh Air Fan,2400 CFM / 42 MM Static - Fresh Air Fan Each 2 2,85,000.00 5,70,000.00
99 Supply, Installation, Testing and Commissioning of perforated painted with powder coating
M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with
M.S. suspenders including bolts & nuts, painting suspenders etc. as required.
100 150 mm width X 50 mm depth X 1.6 mm thickness Each) M 190 1,470.00 2,79,300.00
101 Supply, installation, testing and commissioning of PLC sequential controller for sequencing, programming and
scheduling the interconnected AHUs with pre-defined duty cycle for equal run, auto stand'by changeover, fault
take'off, etc. as per working requirements complete all as
specified and directed by the engineer-in-charge.
L FIRE ALARM SYSTEM
Design, Supplying, installing, testing and Commissioning of Microprocessor based Addressable Fire Alarm system.
102 Complying to IS and UL listed / Loss Prevention Control Board (LPCB ) Mark The System shall comply to complying to
IS 2189 , FRelevat IS Standards ,Local Fire Officer requirement, Specification and Relevant
103 Supply, Installation, Testing, and Commissioning in position approved make Manual Call Point with talk back facility
and break glass push button in metal enclosure
104 Supply, Installation, Testing, and Commissioning in position approved make Hooters cum strobe with CRCA
Supply, Installation, Testing, and Commissioning in position approved make Smoke Detector (SURFACE MOUNTED) Nos. 40 3,800.00 1,52,000.00
Supply, Installation, Testing, and Commissioning in position approved make Heat Detector (SURFACE MOUNTED) Nos. 8 6,750.00 54,000.00
Supply, Installation, Testing, and Commissioning in position approved make UL-FM Approved Potential-free, Form-C,
SPDT contact based relay module to trigger 3rd party utilities like AHU shut-off, Pressurization fan activation, etc.
BILL OF QUANTITY
Sr. No. Description Unit Qty Rate Amount
Supply, Installation, Testing, and Commissioning in position approved make Microprocessor based addressable 4 loop
Fire Alarm Control Panel (FACP) suitable to cater to Above Call points and Hooters etc to complete the System Nos. 1 3,50,000.00 3,50,000.00
as per IS standard.
109 Supply, Installation, Testing, and Commissioning in position approved make Wiring for Addressable Fire Alarm system
with 2 core 1.5 sq.mm Stranded FRLS copper conducter cable in the concealed 20MM Rigid MMS PVC conduit PVC Mtr 500 170.00 85,000.00
conduit as per specification and Relevant drawings as required.
110 Supply, Installation and Commissioning of Beam Detector comprising of 4 wire system with Infrared emitter
and receiver in a single housing and single reflector plate - 5-50mtrs. Range - equipped with built-in
automatic compensation - in-built laser light for easy alignment - Option for remote indication - Three
sensitivity threshold of 18%, 30% & 50%
M Supply Installation Testing & Commissioning of Access Control System
111 ESSL AirfaceMagnum FACE, Biomatric & card Access Control System, Drop Bolt Lock / EM Lock, SET 6 40,000.00 2,40,000.00
Grand Total = C 4,90,69,297.00
Grand Total = C 4,90,69,297.00
Total Amount Including GST =( Four Crore Ninety Lakh Sixty Nine Thousand Two Hundred Ninety Seven Only)
Total Amount Including GST =( Four Crore Ninety Lakh Sixty Nine Thousand Two Hundred Ninety Seven Only)
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT.pdf
Tender Document
FINAL BOQ THEATRE WORK.pdf
Tender Document
SCC.pdf
Tender Document
6GCCPMCContracting2022mergedcompressed.pdf
Tender Document
List of Approved Make.pdf
Tender Document
Panels Specifications Annexure-B.pdf
Tender Document
1 4th FlOOR THEATRE Acoustics-Ceiling Details.pdf
Tender Document
2 4th FlOOR THEATRE Acoustics-Floor Details.pdf
Tender Document
3 4th FlOOR THEATRE Acoustics-Wall Details.pdf
Tender Document
4 4th FlOOR THEATRE Acoustics-Wall-Ceiling-Floor section.pdf
Tender Document
5 4th FlOOR THETRE Acoustics-Plan ELevation.pdf
Tender Document
6 6th FLOOR AUDIO STUDIO Acoustics-Acoustic Ceiling.pdf
Tender Document
7 6th FLOOR AUDIO STUDIO Acoustics-Acoustic Ceilng -Wall-Flooring.pdf
Tender Document
8 6th FLOOR AUDIO STUDIO Acoustics-Acoustic Flooring.pdf
Tender Document
9 6th FLOOR AUDIO STUDIO Acoustics-Acoustic Inner Wall.pdf
Tender Document
10 6th FLOOR AUDIO STUDIO Acoustics-Audio Studio Layout.pdf
Tender Document
11 Acoustics-Cabin Conf Room Walls.pdf
Tender Document
12 Acoustics-Edit DI Room Walls.pdf
Tender Document
13 Door Section Details.pdf
Tender Document
14 Floor LT PANEL.pdf
Tender Document
15 IICT-PHASE-I-Layout DWG-28MAR25-4th FLOOR.pdf
Tender Document
16 IICT-PHASE-I-Layout DWG-28MAR25-5th FLOOR.pdf
Tender Document
17 IICT-PHASE-I-Layout DWG-28MAR25-6th FLOOR.pdf
Tender Document
18 IICT-PHASE-I-Layout DWG-28MAR25-7th FLOOR.pdf
Tender Document
19 Power Distribution Plan Panel Placements-A0.pdf
Tender Document
20 SLD for Electrical Distribution-28MAR25.pdf
Tender Document
21 UPS PANEL.pdf
Tender Document
corrigendum-3748-CORRI02NFDC.pdf
pdf • 0.44 MB
corrigendum-3721-NFDCCORRI01.pdf
pdf • 0.59 MB
addendum-8e5d06437855-Addendum01.pdf
pdf • 0.73 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .