Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAdmitted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | L1 | Admitted-Finance | |
| 2 | L2₹18.1 L+₹1.4 L (8.54%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Premier Engineering Company L1 | VISHNU ELECTRICAL & MILL HARD STORE L2 |
|---|---|---|---|---|---|
| 1.01 | Dismantling of old ACB & other accessories from existing Panel, removing of all cable connection after taking shut down with heavy labor etc. | 10 | Jobs | 43,500 ₹51,330 Lowest | 45,000 ₹53,100 |
| 1.02 | Air circuit breakers (ACB), 3 pole, 3200Amp. EDO type with microprocessor based Make L.K | 1 | No | 6,53,678 ₹7,71,340.04 Lowest | 7,10,000 ₹8,37,800 |
| 1.03 | Replacement of Amp. Meter digital with selector switch Make: LK | 6 | Nos. | 25,500 ₹30,090 Lowest | 27,000 ₹31,860 |
| 1.04 | Replacement of Volt Meter digital with selector switch Make LK | 2 | Nos. | 8,500 ₹10,030 Lowest | 9,000 ₹10,620 |
| 1.05 | Replacement of UV release Make LK | 6 | Nos. | 1,01,700 ₹1,20,006 Lowest | 1,11,000 ₹1,30,980 |
| 1.06 | Replacement of digital over current/ earth fault relay type MC3I MakeLK | 2 | Nos. | 83,400 ₹98,412 Lowest | 90,400 ₹1,06,672 |
| 1.07 | Retrofitting of ACB (3200A, 3 Pole) as above in existing panel by carrying out following works:- 1) Supply of necessary hardware, supports etc. 2) Making /supply of M.S angle base frame/supports of size as suitable to the mounting of new ACB. Fixing of the same at the panel chamber with the help of nuts bolts /welding etc. as suitable for installation of new ACB /their cradles. 3) Dismantling the existing circuit breaker from the chambers of the LT panel including its cradles and disconnecting the bus bar connections with the main bus bars, disconnecting the outgoing cables etc. 4) Installation of new ACB cradle in the panel by the help of nuts bolts etc in proper condition for connecting the bus bars. Fixing the ACB in the cradles in the proper condition including checking the movement. Making control wiring connection for the ACBs. 5) Connecting the main bus bars to the incoming sides of the ACB by re-arrangement/modification/addition of bus bar lengths in Aluminum construction for retrofitting of ACB. 6) making a new M.S. door in 2mm CRCA Sheet, powder coated as suitable size to match symmetry. Connecting the bus bar at the outgoing side of the ACB by re-arrangement/modification/addition of bus bar lengths in Aluminum for retrofitting of ACB. 7) Testing of the ACB for ON-OFF operation first at NO load and then at ON load including operation, manual charging system etc. | 1 | Job | 1,60,000 ₹1,88,800 Lowest | 1,75,000 ₹2,06,500 |
| 1.08 | Cleaning of incoming & outgoing bus bar for (3Nos. 3200Amp. ACB & 8Nos. 800) Amp. ACB horizontal bus bar Aluminum& insulation with heat shrinkable PVC sleeve/PVC tape throughout in red, yellow & blue color to identify three phases & black for neutral | 11 | Jobs | 82,500 ₹97,350 Lowest | 85,800 ₹1,01,244 |
| 1.09 | Cleaning of ACB 3200Amp. removal of old grease and re-greasing of all movable parts with recommended grease, setting of tripping mechanism, wiring of under voltage coil, complete cleaning of ACB with making all incoming & out going cable connection with thimbling. | 2 | Jobs | 47,500 ₹56,050 Lowest | 51,000 ₹60,180 |
| 1.10 | Cleaning of ACB 800Amp. removal of old grease and re-greasing of all movable parts with recommended grease, setting of tripping mechanism, cleaning of ACB with making all incoming & out going cable connection with thimbling. | 7 | Jobs | 1,27,400 ₹1,50,332 Lowest | 1,43,500 ₹1,69,330 |
Tender Value
Refer Docs
EMD Value
₹33,600
Closing Date
26 Oct 2026, 3:15 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE ENM M 7
MU BLOCK PITAMPURA
Repair Renovation of L and T Make LT panel installed at Lawrance Road BPS in AC 17
2026_DJB_300278_2
NIT No. 17(2026-27)M-7
Open Tender
Miscellaneous Works
Item Rate
60 days
EE ENM M 7
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No. 50448339804
₹33,600
Yes
3 Nov 2026
19 Oct 2026
26 Oct 2026
19 Oct 2026
26 Oct 2026
19 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Dismantling of old ACB & other accessories from existing Panel, removing of all cable connection after taking shut down with heavy labor etc. | 10 | Jobs | 80 | ₹800 |
| 1.02 | Air circuit breakers (ACB), 3 pole, 3200Amp. EDO type with microprocessor based Make L.K | 1 | No | 80 | ₹80 |
| 1.03 | Replacement of Amp. Meter digital with selector switch Make: LK | 6 | Nos. | 80 | ₹480 |
| 1.04 | Replacement of Volt Meter digital with selector switch Make LK | 2 | Nos. | 80 | ₹160 |
| 1.05 | Replacement of UV release Make LK | 6 | Nos. | 80 | ₹480 |
| 1.06 | Replacement of digital over current/ earth fault relay type MC3I MakeLK | 2 | Nos. | 80 | ₹160 |
| 1.07 | Retrofitting of ACB (3200A, 3 Pole) as above in existing panel by carrying out following works:- 1) Supply of necessary hardware, supports etc. 2) Making /supply of M.S angle base frame/supports of size as suitable to the mounting of new ACB. Fixing of the same at the panel chamber with the help of nuts bolts /welding etc. as suitable for installation of new ACB /their cradles. 3) Dismantling the existing circuit breaker from the chambers of the LT panel including its cradles and disconnecting the bus bar connections with the main bus bars, disconnecting the outgoing cables etc. 4) Installation of new ACB cradle in the panel by the help of nuts bolts etc in proper condition for connecting the bus bars. Fixing the ACB in the cradles in the proper condition including checking the movement. Making control wiring connection for the ACBs. 5) Connecting the main bus bars to the incoming sides of the ACB by re-arrangement/modification/addition of bus bar lengths in Aluminum construction for retrofitting of ACB. 6) making a new M.S. door in 2mm CRCA Sheet, powder coated as suitable size to match symmetry. Connecting the bus bar at the outgoing side of the ACB by re-arrangement/modification/addition of bus bar lengths in Aluminum for retrofitting of ACB. 7) Testing of the ACB for ON-OFF operation first at NO load and then at ON load including operation, manual charging system etc. | 1 | Job | 80 | ₹80 |
| 1.08 | Cleaning of incoming & outgoing bus bar for (3Nos. 3200Amp. ACB & 8Nos. 800) Amp. ACB horizontal bus bar Aluminum& insulation with heat shrinkable PVC sleeve/PVC tape throughout in red, yellow & blue color to identify three phases & black for neutral | 11 | Jobs | 80 | ₹880 |
| 1.09 | Cleaning of ACB 3200Amp. removal of old grease and re-greasing of all movable parts with recommended grease, setting of tripping mechanism, wiring of under voltage coil, complete cleaning of ACB with making all incoming & out going cable connection with thimbling. | 2 | Jobs | 80 | ₹160 |
| 1.1 | Cleaning of ACB 800Amp. removal of old grease and re-greasing of all movable parts with recommended grease, setting of tripping mechanism, cleaning of ACB with making all incoming & out going cable connection with thimbling. | 7 | Jobs | 80 | ₹560 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.06 MB
BOQ_400772.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .