| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹23.4 L+₹2.9 L (13.9%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹23.6 L+₹3.1 L (15.0%)Rejected-Finance B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹24.9 L+₹4.4 L (21.2%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹26.5 L+₹6.0 L (29.1%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance BEING L5 |
Tender Value
Refer Docs
EMD Value
₹57,160
Closing Date
28 Apr 2021, 6:00 pmClosed
GE (AF) PALAM
GE (AF) PALAM, DELHI CANTT-110010
GENP-01/2021-22 REPAIR/MAINTENANCE OF SPLIT/WINDOW AC, WATER COOLER, REFRIGERATOR, DESERT COOLERS AND VOLTAGE STABILIZERS AT AF STATION PALAM, DELHI CANTT-10
2021_MES_434952_1
GENP-01/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) PALAM, DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) PALAM, DELHI CANTT
₹57,160
Yes
26 Jun 2021
7 Apr 2021
29 Apr 2021
7 Apr 2021
28 Apr 2021
14 Apr 2021
Amount
M&L for Servicing of window type AC 1.5/2 TR capacity including oiling, greasing of fan motor, replacement of synthetic filter & checking of electric circuit for smooth functioning of AC complete all as specified. (Note:-Unserviceable/ burnt spare parts of AC shall be meaured and paid separately under repsective items here-in-after.)
All as per item No 1 above but Split AC of 1.5/2 TR.
S&F in replacement of starting relay suitable for 1.5 TR/2TR capacity AC.
S&F in replacement of over load protector suitable for 1.5/2.0 TR capacity AC.
S &F in replacement of starting capacitor 80-100 mfd suitable for 1.5 ton capacity AC.
All as per item No 5 above but 100-120 mfd suitable for 2.0 ton capacity AC.
S&F in replacemernt of capacitor 36 mfd suitable for 1.5 capacity AC .
All as per item No 7 above but 45 mfd suitable for 2.0 ton capacity AC.
All as per item No 7 above but 45 + 6 mfd suitable for 1.5 ton capacity AC.
All as per item No 7 above but 50+6 mfd suitable for 2.0 ton capacity AC.
All as per item No 7 above but 60 + 6 mfd suitable for 2.0 ton capacity AC.
S&F in replacement of wiring kit suitable for 1.5/2 Ton capacity /Window AC complete all as specified and directed
S&F in replacement of wiring kit suitable for 1.5/2 Ton capacity Split AC all as specified and directed.
S&F in replacement of thermostate switch suitable1.5/2 Ton capacity AC all as specified and directed.
S&F in replacement of front grill suitable for 1.5/2.0 TR capacity of window AC.
All as per item No 16 above but base plate suitable for 1.5/2.0 TR capacity of window AC.
All as per item No 16 above but motor capacitor 6 mfd .
S&F in replacement of metal clad socket 20 Amp.
S&F in replacement of metal clad plug 20 Amp.
Taking out unserviceable fan-cum-blower motor and M&L for rewinding and repairing of fan-cum-blower motor of window ytpe AC 1.5/2.00 TR capacity with supper enamelled copper winding wire of existing gauge complete all as specified and directed by Egnineer-in-charge.
All as per item No 21 above but fan motor for split type AC 1.5/2.0 TR.
All as per item No 21 above but blower motor for split type AC 1.5/2.0 TR.
M&L for rewinding and repairing unserviceable reciprocating type compressor suitable for 1.5 TR window/split AC, Re-fixing on its original position and testing for smooth funcitioning including taking out old unserviceable rewinding. Make:- Techumesh/Usha Shriram/Emerson Copeland/Carrier.( Note:- (1) Supply and charging gas shall be measured and paid separtely under respective item of BOQ here-in after. (ii) Contractor will make own alternate arrangement to run the AC during the period of compressor repair and the rate shall be included in the quoted rate of item).
All as per item No 24 above but for 2 TR capacity.
S&F in replacement of reciprocating type compressor of capacity 1.5 TR. Make: Emerson copeland/Tecumesh /Carrier. (Note:-Charging of gas shall be measured and paid separately under respective item here-in-before).
All as per item No 26 above but capacity 2.0 TR.
S&F in replacement of fan-cum-blower motor with propeller, fan blade, rubber seal, holding clamps nuts & bolts for 1.5/2 TR window AC. Make- AUE/ANU/GE Motors/Marathan.
S&F in replacement of blower blade for 1.5/2 TR window AC.
S&F in replacement of fan blade for 1.5/2 TR window/split AC.
S&F in replacement of blower for 1.5/2 TR Split AC.
Supply & charging the refrigerant gas R-22 to window/split type AC upto 2 TR capacity including testing complete all as specified and directed by Engr-in-charge.
Supply & charging the refrigerant gas R-410A to split type AC upto 2 ton capacity including testing complete all as specified and directed by Engr-in-charge.
S&F in replacement of MCB 20 to 32 Amps capacity 230 volt AC supply.
Supply & fixing in replacement of sheet metal Single Pole and Neutral enclosure with a two pin and earth plug and socket compelte with one signle pole MCB 20 Amps.
S&F in replacement of condensor with copper tubing and aluminium fins suitable for 1.5/2.0 TR window AC.
S&F in replacement of condensor with copper tubing and aluminium fins suitable for 1.5/2.0 TR split AC.
S&F in replacement of rotary type compressor of capacity 1.5 TR suitable for working on R-22 Refrigerant. Make: Mitsubhishi/Tech mesh product/LG Hitach. (Note:-Charging of gas shall be measured and paid separately under respective item here-in-before).
All as per item No 38 above but 2.0 TR
S&F in replacement of rotary type compressor of capacity 1.5 TR sunitable for working on R-410 A refrigerant . Make: Mitsubishi/Techmesh /LG/HiTachi /Carrier. (Note:-Charging of gas shall be measured and paid separately under respective item here-in-before).
All as per item No 40 above but capacity 2.0 TR.
Supply & fix in replacement PCB card suitable for 1.5/2. 0 TR capacity of split AC including suitable for invertor AC's of said capacity complete all as specified and directed.
M&L for repairing of PCB card suitable for 1.5/2 TR capacity of split AC's complete all as specified and directed.
Supply & fixing in replacement of swing motor suitable for 1.5/2.0 TR capacity of window/Split AC complete all as specified and directed.
Supply & fixing in replacemnt of PVC drain pipe 15mm dia with fittings and fixing accessories complete all as specified and directed.
Labour only to convert split AC 1.5/2.0 TR from cooling mode to heating mode by heating element/reverse solenoid valve arrangement wiring interlocking as requried complete all as specified and directed.
S&F in replacemnt of reverse valve suitable for split type AC 1.5/2.0 TR including additional copper tubing of any size brazing work, pressure testing, dehydration gas charging upto required level and necessray modification in remote control unit for satisfactory function of unit in heating mode complete all as specified and directed.
S&F in replacemnt of condensor with copper tubing and aluminium fins suitable for 1.5/2.0 TR window type AC suitable for working on R-22 Refrigerant. ( Note-Supply and filling of refrigerant gas shall be measured and paid separately undrer respective item of this schedule).
All as per item No 48 above but Split type AC.
S&F in replacemnt of cooling coil with copper tubing and aluminium fins suitable for 1.5/2.0 TR window type AC suitable for working on R-22 Refrigeran.( Note-Supply and filling of refrigerant gas shall be measured and paid separately undrer respective item of this schedule).
All as per item No 50 above but Split type AC.
S&F in replacemnt of condensor with copper tubing and aluminium fins suitabel for 1.5/2.0 TR split type AC suitable for working on R-410A refriegrant.( Note-Supply and filling of refrigerant gas shall be measured and paid separately undrer respective item of this schedule).
S&F in replacemnt of cooling coil with copper tubing and aluminium fins suitabel for 1.5/2.0 TR split type AC suitable for working on R-410A refriegrant . ( Note-Supply and filling of refrigerant gas shall be measured and paid separately undrer respective item of this schedule).
Taking out old perished insulation and M&L for insulating the suction and discharge copper tubing from indoor unit to outdoor unit of split type AC of capacity 1.5/2.0 TR capacity with neoprene foam sleeves incuding sealing by applying adhesive tape of brown or white colour to avoid minimum contact with atmosphere complete all as specified and directed.
Taking out old unserviceable copper tubing and M&L for suction and discharge copper tubing of size 1/2 inch and 1/4 inch dia and 0.5mm thickness from indoor unit to outdoor unit of split type AC 1.5 TR capacity including soldering and braizing complete all as specified and directed. (Note:- Suction and discharge copper tubing together wil be measured as one unit of running metre).
All as per item No 55 above but copper tubing size 5/8 inch and 3/8 inch dia and 0.5mm thickness.
S&F in replacemnt of suction line valve assy of size 1/2" dia from outdoor unit of split tpe AC including soldering and braizing complete all as specified and directed.
All as per item No 57 above but discharge valve assy size 3/8" dia.
S&F in repair non metallic PVC conduit exclusive of junction boxes but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks et cof size 20mm dia.
All as per item No 59 above but 25mm dia.
S&F in replacement of electric cables PVC insulated rubber sheathed circular multistranded copper conductor of size 2.5 Sqmm 3 core.
Supply & fixing in replacement of AC stand wall mounted/floor mounted type suitable for existing type/Model of AC's complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacement of indoor unit suitbale for existing type 1.5/2TR capacity Split AC complete all as specified by Engr-in-charge.Make: Voltas/LG/Hi-Tachi
Supply & fixing in replacement of outdoor unit suitbale for existing type 1.5/2TR capacity Split AC complete all as specified by Engr-in-charge. Make: Voltas/LG/Hi-Tachi
Taking down copper/aluminimum point wiring (light ,fan, socket or power) complete incuding fixtures and fitings such as swtiches, ceiling roses, pandants, regulators, sockets, light fittings etc and making good disturbed surfaces of walls, floors etc.
Material and labour for point wiring with single core PVC sheathed 1100 volt grade cable FRLSH with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, with GI saddles GI screws, rawl plugs (concealed conduit wiring in walls ) including Tee, Junction boxes and provision of 3 mm thick plastic laminated sheet cover of suitable size on existing terminal boxes with new brass screws for mounting switches sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one 3 pin socket outlet 5 Amps indpendent board all as directed by Engineer-in-charge.
Material and labour for point wiring with single core PVC sheathed 1100 volt grade cable FRLSH with multi stranded copper conductor of size 4.00 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, with GI saddles GI screws, rawl plugs (concealed conduit wiring in walls ) including Tee, Junction boxes and provision of 3 mm thick plastic laminated sheet cover of suitable size on existing terminal boxes with new brass screws for mounting switches sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with stranded copper conductor of size 4.00 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one 3 pin socket outlet 15 Amps on indpendent board complete all as specified and directed by Enginer-in-charge.
S&F in replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one singe pole MCB of capacity 20 Amps complete all as specified and directed by Engineer-in-charge.
REFRIGERATOR S&F in replacement of compressor 1/8 HP suitable for refrigerator of capacity 165 to 200 ltrincluding testing on completion. Make: Techumesh/LG/Whirlpool. (Note: Supply and Charing of gas R-134 shall be paid separately under respective item)
All as per item No 69 above but refigerator capacity 220 to 320 ltrs.
S&F in replacement of evaporator cooling coil of referigerant 165 to 200 ltrs capacity complete all as speciifed and directed by Egnineer-in-charge.
S&F in replacement of evaporator cooling coil of refrigerant 220 to 320 ltrs capacity complete all as specified and directed.
S&F in replacement of relay box type/open type suitable for 1/6 to 1/8 HP refrigerator of any make & size (Make Hitech/Renturol).
S&F in replacement of overload protector suitable for refrigerator of any make & size complete all as specified and directed.
Taking out existing old rusted bottom body and frame door from refrigerator and M&L for repairing of any size & capacity or referigerator body bottom and frame door with mild steel flat, angle iron & plain GI sheet of existing gauge by electric welding incuding preparation of surface and painting with spray paint on steel and iron surface of approved make complete all as specified and directed.
M&L for spray painting of refrigerator of any size and make with two coats synthetic enamelled paint over existing surface. The work includes surface preparation, filling of damaged portion etc complete all as specified and directed.
Taking out burnt defective compressor 1/3 HP from deep freezer of capacity 425 ltr and S&F new compresor 1/3 HP capacity suitable for deep freezers 425 ltrs capacity of make : Kelvinator/Ashoka including dehydrating of system and charging of compressive oil & refeigerant gas complete all as specified and directed Make: Kirloskar/Techumesh.
S&F in replacemernt of thermostatic switch for refrigerator of any make and 165 to 320 ltrs capacity all as specified.
Supply & fixing in replacemnet of door gasket suitable for refrigerator of capacity 165/200 ltr single door.
Supply & fixing in replacemnt of door gasket suitable for refrigerator of capacity 286/300 ltrs single door.
Supply & Charging the refrigerant gas R-134A in refrigerator of capacity 165 to 200 ltrs including testing complete.
Supply & Charging the refrigerant gas R-134A in refrigerator of capacity 200 to 320 ltrs including testing complete.
Supply & Charging the refrigerant gas R-134A in deep freezerr of capacity 200 to 425 ltrs including testing complete.
WATER COOLER M&L for Servicing and cleaning of water cooler 40 to 80 ltrs capacity from inside and outside with potassium permaganatse including servicing of fan motor, condensor, fan blade and its connected water and refrigerant fitting, testing water tank leakage etc complete. (NOTE: Spare parts required for smooth fuctioning of the machine shall be measured and paid for separately under respective items).
All as per item No 84 above but capacity 120 to 150 ltrs.
S&F in replacemernt of compressor suitabe for 40 to 80 ltrs capacity water coolers any make, re-fixing on its origianl position and testing for smooth functioning. (Note: Supply & charging of gas R-22/R-1348 shall be paid separately under respective item).
All as per item No 86 above but capacity 120 to 150 ltrs.
M& L for charging refrigerant gas R-22 in the water cooler of any make 40 to 80 ltrs capacity including testing and detecting leakage with nitrogen gas and vaccum the system complete all as specified and directed by Engineer-in-charge
All as per item No 88 above but capacity 110 to 150 ltrs.
M&L for charging refrigerant gas R-134A in the water cooler of any make capacity 40 to 80 ltrs including testing and detecting leakage with nirogen gas and vaccum the system complete all as specified and directed by Engineer-in-charge
All as per item No 90 above but capacity 120 to 150 ltrs.
S&F in repalcement of overload relay box type suitable for water cooler complete all as specified and directed by Engineer-in-charge
S&F in replacement of thermostat switch suitable for water cooler of any make and size complete all as directed by Engineer-in-charge
S&F in replacement of starting relay suitable for water cooler all as specified and directed by Engineer-in-charge.
S&F in repalcmeent of overload relay make: Classic/Renutrol No 1022/522 complete all as specified and directed.
M&L for spray painting of water of cooler of any make 40 to 80 ltrs capacity as per existing colour (after scraping the old damaged paint making good to the disturbed surface to match with the existing surface) and shade with synthetic enamelled complete all as specified and directed.
All as per item No 96 above but capacity 120 to 150 ltr.
S&F in replacement of defective push cook 15mm dia chromium plated heavy duty suitable for water cooler of any make capacity complete all as specified and directed by Engineer-in-charge.
S&F in replacemnt fo PVC float valve assembly 15mm dia for water cooler of any make 40 to 80 ltrs capacity complete all as specified.
S&F in replacement of PVC float valve assembly 15mm dia for water cooler of any make 120 to 150 ltrs capacity complete all as specified and directed.
S&F in replacement of running capacitor 25 mfd complete all as specified and diirected by Engr-in-charge.
S&F in replacement of running capacitor 30 mfd complete all as specified and diirected by Engr-in-charge.
M& L in replacement of water cooler base including fabrication with angle iron frame, bottom base with MS sheet of 15 gauge including welding brazing, repalcemnt of MS hinge half swing of top cover, top gasket all as per site requirement incuding paitning a coat of red oxide primer as directed by Enginer-in-charge
S&F in replacement of fan motor suitable for water cooler of capacity 40 to 80 ltrs complete all as specified and directed.
All as per item No 104 above but capacity 120 to 150 ltrs.
S&F in replacement of aluminium fan blade suitable for 40 to 80 ltrs of water cooler all as specified and directed. .
All as per item No 106 above but capacity 120 to 150 ltrs
S&F in repalcement of condenser copper tubing with aluminium fins suitable for 40 to 80 ltr capacity water cooler.
All as per item No 108above but capacity 120 to 150 ltrs.
M& for rewiding and repairing of fan motor suitable for water cooler capacity 40 to 80 ltrs of any size with super enamelled copper conductor of existing gauge complete all as specified and directed
All as per item No 110 above but capacity 120 to 150 ltrs.
DESERT COOLER M&L for cleaning of water tank of desert coolers and cleaning of side panels with steel wire brush, scratching old paint from complete desert cooler externally and internally and painting of the same with synthetic enamel paint (ash/hammerton epint) one coat extrernally with spray painting and with a coat of wate resistance paint inside over a suitable primer coat including replacement of internal wiring of suitable size complete all as specified and directed.
Taking down existing unserviceable fan motor assembly complete with blades and mounting frame leg with rubber bush from desert coolers and S&F motor assembly complete with blades, mounting frames legs with rubber bus for desert cooler of capacity 3000/4000/5000 cum hrs and testing complete all as specified and directed by Engineer-in-charge.
M&L in replacement of unserviceable /burnt submersible pump for desert cooler suitable for operation 230 volts AC supply of capacity 18 watt complete all as specified and directed by Engineer-in-charge.
Taking out pads with nylon threads suitable for any make of desert cooler and S&F wood wool pads with nylon threads suitable for any make of desert cooler having minimum maximum capacity 3000 cum/hr to 5000 cum hrs incuding S&F iron with PVC insulated protective guards for holding the wood pads firmly complete all as specified and as directed.
S&F in replacement of body of desert cooler 4000 cum/hrs capacity made out of galvanized iron sheets with bottom tank of 18 gauges, top cover of 20 gauge and side panels of 23 gauge GI sheet duly fitted with 1/3 inch thick woold wool pads including heavy duty 22 gauge frame grill burried with one piano type switch 5 Amps complete all as specified and directed
All as per item No 116 above but 3000 cum/hr capacity.
S&F in replacement of side panels for desert cooler of capacity 3000 cum/hr made with 22 gauge GI sheet complete all as specified.
S&F in replacement of side panels for desert cooler of capacity 4000 cum/hrs made with 22 gauge GI shet complete all as specified and directed
S&F in replacement of side panels for desert cooler of capacity 5000 cum/hrs made with 22 gauge GI sheet complete all as specified.
S&F in replacement of PVC water distribution system of desert coolers complete with PVC elbow, PVC pipe heavy duty 15mm dia all as directed
S&F in replacement of 15mm float valve PVC complete all as specified .
Taking out the existing desert cooler from ground/1st floor for repairs & re-fixing only of desert cooler at ground/1st floor after servicing/repair at required position including painting complete of existing MS angle iron stand as per existing colour all as directed and complete all as specified and directed.
S&F in replacement of 4mm thick commercial plywood as in existing window at any floor including cutting of plywood all as directed (for the purpose of payment the area of plywood cut out in front of grill shall also be taken into account and other piece of plywood shall be remain with the contractor).
S&F in repairs angles iron 40mmx40mmx6mm thick as in frame cut to shape for fixing in wall in cement concrete incuding cutting and fabricating with a coat of red oxide primer complete all as specified and directed by Engr-in-charge
M&L for rewinding of desert cooler fan motor/exhaust fan motor of any make and sweep and size including replacing of suitable bearing & bushes and greasing to make fully functional complete all as specified and directed.
S&F in replacement of damaged/rusted front grill suitable for 3000 to 4000 CFM capacity desert cooler made out of GI shet of 20 gauge heavy duty complete with knob to separate the shutter including one piano type switch and one three speed seleector switch complete all as specifie and directed by Engineer-in-charge.
S&F in replacement of electric cable PVC insulated rubber sheathed circular multistranded copper conductor of size 1 Sqmm 3 core.
S&F in replacement of GI tubing 15mm bore in ground/1st floor with connected fittings such as the elbows, nipple and as directed by Engineer-in-charge.
S&F in replacement of PVC stop cook 15mm.
S&F in replacement of PVC connection 600mm long.
S&F in replacement of PVC connection 900mm long .
S&F in replacment of switch Piano type 5 Amps.
S&F in replacement of plug top 5 Amps.
S&F in replacement of plug top 15 Amps.
VOLTAGE STABILISERS M&L for opening, dismantling, tracing the faults, repairing, servicing and re-assembling the voltage stabilizer suitable for 230 volts 50 Hz, AC supply single phase of capacity 5 KVA complete all as specified and directed by Egnineer-in-charge.
M&L for rewinding of transformer compelte with super enamelled copper winding wire of same gauge including varnishsing, draying, insulating complete suitable for voltage stabilizer 5 KVA capacity suitable for working 30 volts, 50 HZ Ac supply.
All as per item No.138 above but replacement of electromagnetic power relay A-50, 24 volts series SR.
All as per item No.138 above but replacement of voltmeter (0-300) volts of Make as per existing.
All as per item No.138 above but replacement of PCB as per existing make.
All as per item No.138 above but replacement of LCD display unit complete as per existing make.
All as per item No.138 above but replacment of input and output connection terminal plate.
M& for opening, dismantling, tracing the faults, repairing, serv icing and reassem bling the voltage stablisers suitable for 230 volts 50 Hz, AC supply single phase of capacity 4 KVA complete all as specified and directed.
M&L for rewinding of transformer compelte with super enamelled copper winding wire of same gauge including varnishsing, draying, insulating complete suitable for voltage stabilizer 4 KVA capacity suitable for working 30 volts, 50 HZ AC supply.
All as per item No.145 above but replacement of electromagnetic power relay A-50, 24 volts series SR.
All as per item No.145 above but replacement of voltmeter (0-300) volts of Make as per existing.
All as per item No.145 above but replacement of PCB as per existing make.
All as per item No.145 above but replacement of LCD display unit complete as per existing make.
All as per item No.145 above but replacment of input and output connection terminal plate.
M/S Anand Enterprises
HONEY COLLECTION
SNOWY ENGINEERING INC
J.P. Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .