Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹69.1 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L-1 | Accepted-AOC being L-1 | |
| 2 | L-2₹72.2 L+₹1.4 L (1.98%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹72.2 L+₹1.4 L (2.01%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L-3 | Rejected-Finance Being L-3 | |
| 4 | Rejected-Technical 1446 ELITE ENTERPRISES NORTH SOLAPUR NEAR SUSHIL MARATHI SCHOOL SOLAPUR MAHARASHTRA 413004 | SOLAPUR | MAHARASHTRA | 413004 | - | Rejected-Technical Not Recommended for opening due to two class below of eligible class and not enlisted in cat C (iii) and DD not uploaded | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Recommended for opening due to two class below of eligible class and not enlisted in cat b (i), c (iii), d (v) |
Tender Value
₹70.7 L
EMD Value
₹1.3 L
Closing Date
1 Jan 2024, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
MANNING AND OPERATION OF WATER SUPPLY INSTALLATION, DG SET AND MAINT TO DG SET, AMF PANEL AT 31 WEU THANE, NRS THANE AND REPAIR/ MAINT OF EOT AND HOT CRANE AND SECURITY LIGHTS, GARDEN LIGHTS AND COOLING AND SUMMER APPLICANCES UNDER GE (NW) MANKHURD
2023_MES_630889_1
8853/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
MANKHURD
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) MANKHURD
₹1.3 L
14 Feb 2024
2 Dec 2023
3 Jan 2024
2 Dec 2023
1 Jan 2024
25 Dec 2023
Amount
Comprehensive repairs & maintenance to HOT cranes (2 Nos )having 1 Ton capacity with 10 metrs span located in Torpedo workshop to be carried out as under:- (a) Opening of the chain pulley block for location of faults and replacement of unserviceable parts as required at site including attending routine complaints of users to keep the chain pulley block operational through out the year (maximum break down period shall not exceed more than 24 hrs from the time of receipt of complaint) (b) Checking the alignment of the ISMB for free movement of mechanically operated trolley. (c) Repairs/ maintenance of mechanically operated trolley including replacement of worn out parts complete for smooth functioning of the crane. (d) Application of grease to components and chain as per the manufacturers instructions. (e) Load testing of the crane after every repairs as per the instructions of 'handling explosive devices/ ammunition. (f) Load testing as per SWL of crane capacity. Note: Load will be arranged by the department within the radius of 2 KM from the testing site. However shifting of the loads to testing site and back to the place by engaging suitable crane/transport with man power shall be the contractors responsibility and the quoted rate shall be deemed to include for the same.
All as per Item No 1.00 above but for 22 cranes of capacity 2 Ton, located in EKM workshop, APR 2, P-50 HTL, A to G structure Magazine NAD Trombay and P-75 to P-78.
All as per Item No. 1.00 above but for 6 cranes of capacity 3/3.5 Ton, located in EKM workshop at NAD Trombay and NSD T-66.
Comprehensive repairs & maintenance and repairs to 1 No of EOT crane having capacity 2 Tons with 8 meters span of 4 M lift located in WED Sonobouy workshop with the following repairs :- (a) Opening of gear box of LT/CT, crab for examination, replacement of worn out parts and tightening the loosened components, checking, locking systems and closing up including testing commissioning in whenever required in any number of times through out the year including load test after every repair as per the instruction by Engineer in Charge. The permissible break down period for repair shall not exceed 24 hr from the time of receipt of complaint. (b) Checking the alignment of the ISMB for free movement of mechanically operated trolley and replacement of the chain if required. (c) Repair/replacement of worn out/burned unserviceable electrical items as required at site. (d) Tightening the DSL conductors and replace the supports if found necessary. (e) Applying grease to the components whenever required and replacement of Gear oil as per manufacturers instructions. (f) Testing of the limit switches, breaks and settings as required and to be replaced whenever unserviceable for smooth functioning through out the year. (g) Load testing as per SWL of Crane capacity. (h) Painting of the 1 SMB/ equipments of HOT/EOT as required and existing to be done once in a year as per the directions given by the Engineer in Charge.
All as per Item No.4.00 above but for 1 crane of capacity 2 Ton having 10 meter span of 4 meter lift located in WED TP Sonobouy.
All as per Item No.4.00 above but for 2 cranes of capacity 3/3.5 Ton having 11 meters span of 4 meter lift located in EKM Workshop and section 5 at NAD (T).
All as per Item No.4.00 above but for 1 crane of capacity 5 Ton having 11 meters span and 8 meters lift located in Shed No -16 and AK- 230 at WED mankhurd.
All as per Item No.4.00 above but for 1 crane of capacity 20 Ton having 12 meters span and 11 meters lift located in WED shed No-7. NOTE :- Load will be arranged by the department within the radius of 2 Km from the testing site. However, shifting of the loads to testing site and back to the place by engaging suitable crane/transport with man power shall be the contractors responsibility and the quoted rate shall be deemed to include for the same.
Comrehensive preventive maintenance by technically qualified technician and rendering operationally 2 Nos EOT crane of 30 TON capacity at DSRV as mentioned below including assemblies inspection to maintenance of longitude travel/cross travel system assy and checking lubricating of gear system topping up of lubricant upto desired level, replacement of gasket, nut, bolts, washer, split pins for proper tightness and safety including replaement of worn out part such as slip rings, Rubber Buffer, checking of coupling unit travel track etc all other miscellaneous item & ensure safe operation of crane. Preventive maintenance of housing system assy comprising of inspection checking including topping up/ charging of lubricants & gasket inspection and checking of bracing, pulley, nut, dolys washer, split pins, bushes, hooks, checking of housing pulley and lubrication thereof inspection of hoisting rope for cut aberration etc & cleaning up all greasy/ clipping materials inspection servicing, setting and testing breaking limit system for its safe operation. Inspection, checking and setting out. Preventive maintenance of elecrical control system complete all as specified and directed by Engr-in-Charge. Note: (a) Ispection checking decarbonising & tightning of electrical connection in total system includig replacment of thimbles etc. (b) Inspection & checking of fuses, setting & tightning the same as per their capacity. (c) Inspection & setting of voltage system including replacement of fused indicating lamp etc. (d) Spares for EOT crane will be measured and paid seperately. (e) Contractor will carry out comprehensive maintenance once in a month for 12 months and maintain the record of the same as per the performa of monthly maintenanc check. (f) Contractor ensure serviceability and safety of crane during his each visit by way of maintining job card duly signed by JE E/M. (g) The contractor will also send Technician on call basis in case of any fault. Fault to be rectified within 8 hrs of receipt of complaint failing which Rs. 500/- per day will be deducted till rectification of defect. (h) Rates of all consumables such as lubricant, gear oil, nut bolt, split pins, bushes, gasket are deemed to be included in the rates. (j) The tenders are required to submit the intent of MoU from any one of the OEM's i.e, M/s Rockwell Hoisto Cranes Pvt Ltd, M/s Poineer Cranes, M/s Hercules Hoisto, M/s Turbo Fergusan (India) Pvt Ltd, M/s Dinesh Enterprises, M/s Cranex, M/s USCGC, M/s Garlik, M/s Morri, M/s Hindustan Livers, M/s Grip Engineers, M/s Meta feb, M/s JPSENT, M/s Joel Industries. (k) The maintenance & repair under this contract shall be done through MoU issued by any one of OEM e.i M/s Rockwell Hoisto Cranes Pvt Ltd, M/s Poineer Cranes, M/s Hercules Hoisto, M/s Turbo Fergusan (India) Pvt Ltd, M/s Dinesh Enterprises, M/s Cranex, M/s USCGC, M/s Garlik, M/s Morri, M/s Hindustan Livers, M/s Grip Engineers, M/s Meta feb, M/s JPSENT, M/s Joel Industries. (l) Note : Crane load test certification to be certified by Govt recognised/approved agency and rate shall be included in the quoted rate. Note : For item No 1 to 9 : Crane load test certification to be certified by Govt recognised/approved agency and rate shall be included in the quoted rate. Painting of the HOT/EOT as required and existing to be done once in a year as per the directions given by the Engineer in Charge.
Material and labour for load testing 2 Nos of EOT crane of 30 Ton having 29 Meters span and 12 Meters hook height lift located in DSRV including all necessary preparation of test such as collecting of load block and re-depositing in the existing location, binding work, welding and all related material which may be required on ground to complete the whole testing procedure ascomplete job for both cranes. Note : (a) Crane load Test certification to be conducted by recognised crane manufacturer/ govt approved testing agent and submit to this office. Rate for the same shall be inclusive in the quoted rate. (b) Arrangement of mobile lifting machines, man power and supervisory staff for the complete test as specification above shall be the complete test as specified above shall be the sole responsibility of the contractor and rate shall be included in the quoted rate. (c) Any damage which may take place due to mishandling of testing procedure, inefficient of supervisory staff etc shall be made good by the contractor. (d) Load Cell required at site during testing will be provided by the contractor and rate shall deem to be in the quoted rate. (e) Any item which is not mentioned here-in-before but technically required while conducting the test shall be incorporated by the contractor to enable to complete the test satisfactorily and rate of the same shall deemed to be included in the quoted rate. (f) Load base platform suitable to carry safety the load (i.e not less than 50 Ton capacity) with sling of required Nos, shackle etc duly certified of their capacity/strength shall be provided for conducting the load and rate of the same shall be included in the quoted rate.
Supply & fixing in repair Two way lever type Limit switch Two contect Type LS/2SH/2 in IP 54 enclosure complete all as specified and directed by Engr-in-charge
Supply & fixing in replacement of A.C Drive (VVVF) 22 KW/ 30 HP for C.T Type A1000, 400 V complete all as specified & directly by Engr-in-Charge
Supply & fixing in replacement of A.C Drive (VVVF) 22 KW/ 5 HP for C.T Type A1000, 400 V complete all as specified & directly by Engr-in-Charge
Supply & fixing in repair to Three Pole power contactor 32 Amp with Aux contect coil voltage 110 V AC complete all as specifed & directed by Engr-in-Charge
Supply & fixing in repair to Three Pole power contactor 45 Amp with Aux contect coil voltage 110 V AC complete all as specifed & directed by Engr-in-Charge
Supply & fixing in repair to Three Pole power contactor 80 Amp with Aux contect coil voltage 110 V AC complete all as specifed & directed by Engr-in-Charge
Supply & fixing in repair Rodio Remote Control suitable for existing crane complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repair Rotary type limit switch in Dia cast alu. Housing IP 67 Normal action 1 N.O + 1 N.C complete all as specified and directed by Engr -in- Charge
M & L or rewinding of squirrel cage induction electric motor 3 pahse, 415 volts, crane duty of cap 30 HP CDF 60%, 740 rpm complete all as specified and direced by Engr-in-Charge.
M & L or rewinding of squirrel cage induction electric motor 3 pahse, 415 volts, crane duty of cap 5 HP CDF 60%, 740 rpm complete all as specified and direced by Engr-in-Charge.
Supply and fix in repair long travel bearing 2/3 TON capacity complete all as specified and directed by Engr-in-charge.
Supply and fix in repair cable Trolley suitable for existing crane complete all as specified and directed by Engr-in-charge.
Supply and fix in repair Flameproof thuster bearing and coil of existing crane complete all as specified and directed by Engr-in-charge.
Supply and fix in repair wheel chain 2/3 TON capacity complete all as specified and directed by engr-in-charge.
Dismantling and taking down the Trolley Gun Metal Gear Wheel 2 Nos and Plane wheel 2 Nos in repairs and replacing with new ones as per the existing.
Dismantling and taking down the Trolley Gun Metal non Gear wheel 2 Nos and Plane wheel 2 Nos in repairs and replacing with new ones as per the existing.
Supply and fix in repairs Timer for Hoist resistance from EOT crane complete all as specified and directed by engr-in-charge
Supply and fix in repairs Bobin Insulated complete all as specified and directed by Engr-in-charge
Supply and fix in repairs floating shaft drive and provision of wheel pin spacers complete all as specified and directed by engr-in-charge
Supply and fix in repairs Electro Hydraulic thruster brake liner 300 mm dia, up to 62 Kgm suitable for existing brake system complete.
Supply and fix in repairs Electro Hydraulic thruster brake liner 150 mm dia, up to 9 Kgm suitable for existing brake system complete.
Supply and fix in repairs Hydraulic thruster break liner 200 mm Dia for hoist
Supply & replacement of Transformer oil suitable for hydralic thruster brake for EOT Crane including draining out old perished oil complete.
Supply in repairs Gear Oil complete all as specified and directed including taking down old u/s complete.
Taking down the defective damaged chain pulley block operating trolley of HOT crane and design fabricating supply and fixing in repairs HOT trolley complete with ENS 9 wheels , Hand chain wheel drum and hand chain complete as per the existing of capacity 2.0 Ton.
Taking down the defective damaged and broken long travel chain gear wheel mechanism and design fabricating supply and fixing in repairs long travel chain wheel mechanism as per the existing including alingment to line shaft complete all as specified and directed for the HOT crane of capacity 2 TON.
Taking down the defective damaged and broken long travel chain non gear wheel mechanism and design fabricating supply and fixing in repairs long travel chain wheel mechanism as per the existing including alingment to line shaft complete all as specified and directed for the HOT crane of capacity 2 TON.
Taking down old defective chain pulley block and providing new chain pulley block assembly of 1 Ton capacity in repairs all as per directed by Engr-in-Charge.
Taking down old defective chain pulley block and providing new chain pulley block assembly of 2 Ton capacity in repairs all as per directed by Engr-in-Charge.
Taking down old defective chain pulley block and providing new chain pulley block assembly of 3/3.5 Ton capacity in repairs all as per directed by Engr-in-Charge.
M & L for Plumber block with bearing including sleeve complete in repairs all as specified and directed by Engr-in-Charge.
Taking down the defective travelling flexible cable PVC insulated multistranded copper / Aluminium conductor of 4 Sqmm 4 Core and supply and fix new travelling flexible PVC insulated multistranded copper conductor 4 Sqmm 1100 volts grade complete.
S&F in repair, MCCBs in existing FP/panel, connecting to bus-bar with all connecting accessories and modification in busbar (if Necessary), connection complete and testing after completion, all as specified and directed, of following capacities :- Make:- ABB/Legrand/Siemens/L&T/C&S.
(a)MCCB 63 Amps,16 kA,FP, 50 Hz,Thermal magnetic release,lcs=100% lcu.
(b)MCCB 100 Amps,16 kA,FP,50 Hz,Thermal magnetic release,lcs=100% lcu.
(c)MCCB 160 Amps,25 kA,FP,50 Hz,Thermal magnetic release,lcs=100% lcu.
(d)MCCB 200 Amps,25 kA,FP,50 Hz,Thermal magnetic release,lcs=100% lcu.
S&F in replacement of wall mounted outdoor type double door LT panel made out of 3mm thick CRCA sheet the panel shall be provided with flame proof MCB DB made out of cast aluminium alloy LM6, inside and out side light gray epoxy powder coating shade 'O' ring endless neoprene rubber gasket with 1 Nos cable entry for incoming cable and three Nos cable entry for out going circuit with and including cable glands and stopping plug 1 No MCB SPN 32 Amps as incming and 4 Nos MCB SP 6 to 32 Amps for out going connections IP 65 protections as per IS 2147/1962. The panel shall be powder coated front from CPRI approved manufacturer complete all as specified and directed by Engineer in Charge.
S&F in replacement of wall mounted outdoor type double door LT panel made out of 3mm thick CRCA sheet the panel shall be provided with flame proof MCB DB made out of cast aluminium alloy LM6, inside and out side light gray epoxy powder coating shade 'O' ring endless neoprene rubber gasket with 1 Nos cable entry for incoming cable and three Nos cable entry for out going circuit with and including cable glands and stopping plug 1 No MCB SPN 32 Amps as incming and 2 Nos MCB SP 6 to 32 Amps for out going connections IP 65 protections as per IS 2147/1962. The panel shall be powder coated front from CPRI approved manufacturer complete all as specified and directed by Engineer in Charge.
M&L for dismantling overhauling ,packing and refixing of 5 HP, 3 Phase motor after opening carefully and stripping all parts cleaning removing defective burnt winding . Rewinding the motor with super enamelled copper conductor of the existing guage and number of turns as per the original winding pattern of the manufacturer varnishing with quick dry varnish drying it properly oiling and greasing of moving parts ,assembling , reinstalling testing on completion all as directed
Mannual rescue and operation rescue of water distribution sluice valves of various sizes etc with one valveman per shift, operation for 01 shifts/per day, (08 hours each shift) including Sundays and holidays including routine maintenance checks and upkeeping the installation and with the under laid components complete all as specified and as directed by the Engineer-in-charge. Location: 31 WEU Thane (a) Pumping set centrifugal type of capacity 12 litres/sec with 38 m head with electrically driven induction motor 15HP, 3 phase- 02 No. (b) Chemical dozing plant with injection assembly booster pump with induction motor of 1.5HP, 3 phase - 01 No. (c) Vertical type pressure filter of capacity 1000 glns/hr including blower unit with induction motor 5HP, 3 phase - 01No (d) LT electric control panel with all accessories and components - 02 Nos
Note : (a) In case any operator is missing or absent from duty, a penalty of Rs 650/- per shift shall be recovered from any of dues of the contractor and the Engr-in-Charge decision shall be final and binding on this account. (b) The operator shall keep the paints, machineries and valve chamber surrounding area clean and tidy. (c) Contractor shall provide uniform and necessary tools required by the men employed by him. (d) Contractor shall submit the details of payments and wages for staffs employed through Aadhar link bank account Nos for payment purpose. (e) Painting of the equipments of pumps as required and existing to be done once in a year as per the directions given by the Engineer in Charge.
Supply and lay in repairs/ replacement XLPE 4.0 Core 16 Sqmm insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of following sizes laid in trenches/along the wall/pole including making all connections complete as required at site and as directed by Engr-in-Charge.
Supply and lay in repairs/ replacement XLPE 4.0 Core 10 Sqmm insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of following sizes laid in trenches/along the wall/pole including making all connections complete as required at site and as directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/loose soil for laying of under ground cable all as specified and directed by the engineer-in-charge.
Returning filling in including spreading, leveling watering and well ramming in layer not exceeding 25 Cms all as specified and directed by the engineer-in-charge.
Removal of excavated surplus soil not exceeding 50 m and depositing where directed at al level not exceeding 1.5 m above the starting point all as specified and directed by the engineer-in-charge.
M&L for sand cushioning by spreading in trenches fine dry river sand by gently by punning down manually as in cable protection all as specified and as directed by EIC.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified..
S& F in repair of Fuel level assembly complete all as specified and directed by Engineer-In-Charge.
M & L for servicing of Air compressor machine complete all as specified and directed by Engineer-In-Charge.
Supply only bleaching powder for treatment of water and other purposes etc complete all as specified and directed.
M&L for scraping/cleaning surface of pipe lines of size 40mm to 150mm size and preparation of entire surface and applying one coat of Synthetic enamel paint epoxy coated ( Sea green colour for suction and discharge pipe lines) including writing, marking in stencil all as directed.
M&L for scraping/cleaning surface of pumpset, and preparation of entire surface and applying two coat of Synthetic enamel paint epoxy coated ( grey colour and red colour for fan cowl) all as directed.
Supply and fixing Air filter compressor assembly complete in repair including taking down old u/s Air filter as per sample size all as directed by Engineer-In-Charge.
M & L for carrying out 'B' check of 600 KVA DG Set including of 'B' check kit consisting of the following under laid complete all as specified and as directed by the Engineer-In-Charge. (i) S & F Primary Fuel Filter - 01 Set (ii) S & F Secondary Fuel Filter - 01 Set (iii) S & F Oil Filter - 01 No. (iv) Complete cleaning of DG Set (v) Examination and rectification of engine RPM (vi) Monitoring of output and maintaining and adjusting speed governor (vii) Painting of DG sets with two coats of synthetc enamel paint of colour as directed by the Engineer-In-Charge. (viii) Engine oil as required shall be measured and paid separately).
-Ditto all as per item No 61.00 above but 320 KVA DG Set.
-Ditto all as per item No 61.00 above but 250 KVA DG Set.
-Ditto all as per item No 61.00 above but 200 KVA DG Set.
M & L for servicing to AMF panel of DG sets of any capaity including routine/ preventive maintenance checks for trouble free functioning as directed. Note :The rate Quoted deemed to be included all the minor spares such as screws, washers, clips., battery terminals and other spares will be measured and paid seperately under supply only items.
Supply only distilled water in sealed bottles of 1 litre capacity complete all as specifed.
Supply only multi-grade 20 W 40 engine oil for topping upto required levels complete all as specified and as directed by the Engineer-In-Charge.
Supply only coolent for engines for topping up to required levels complete all as specified and as directed by the Engineer-In-Charge.
M & L for dismantling fuel tank of 250 KVA DG Set and draining out fuel in tank, cleaning the tank using pressure jet process, de-scaling the tank completely and refixing the tank in original position and refilling the tank with fuel retrieved on duly calibrating the same through authorised agencies of the manufacture (of DG Sets) complete all as specified and directed by the engineer - in - charge.
Dismantling the U/S stator exiter coil assembly from the 200 /250/ 320 KVA engine housing transporting the same to contractor workshop & refixing testing the same at site after the following repairs (i) dismantling the old U/S winding and rewinding the stator with equivalent size size of super enamalled copper wire to match the original rating & output complete with E class insulation & Lamination
Supply and fixing in repairs fan belts including replacement of u/s fan belts for 125 to 320 KVA DG Set as per sample size all as directed.
Supply and fixing in repairs Residential Silencer including replacement of U/S Silencer for 250 KVA DG Set as per sample size all as directed.
Supply and fixing in repairs Residential Silencer including replacement of U/S Silencer for 200 KVA DG Set as per sample size all as directed.
S&F in repairs relay 12 V DC. suitable for existing AMF panel of suitable capacity.
Supply and Fix in repairs Change Over FP 250 Amps 415 Volt IN SHEET STEEL ENCLOSURE in open construction, panel mounted type with base plate for mounting in panel, including taking down of old Change over and reconnecting the cabes with proper glands.Make: Indo Asian /ABB/Havells/ Standerd
Supply and Fix in repairs Change Over FP 400 Amps 415 Volt IN SHEET STEEL ENCLOSURE in open construction, panel mounted type with base plate for mounting in panel, including taking down of old Change over and reconnecting the cabes with proper glands.Make: Indo Asian /ABB/Havells/ Standerd
Supply and fix in repairs MCCB 300 Amp TP ,415 V, 25 KA fixed type, including taking down of old unsv MCCB after disconnecting existing cables and reconnecting the cabes with proper lugs and glands to new MCCB's complete all as specified and directed. Make : Schneider/Indo Asian/Havells/standard
Supply and fix in repairs MCCB 400 Amp TP ,415 V, 36 KA fixed type, including taking down of old unsv MCCB after disconnecting existing cables and reconnecting the cabes with proper lugs and glands to new MCCB's complete all as specified and directed. Make : Schneider/Indo Asian/Havells/standard
Supply and fix in repairs Fuel Injector Calibration for Fuel pump DG Set of any capacity complete all as specifed and as directed by the Engineer-In-Charge.
Supply and fix in repairs Power Capacitors of Rating 25 KVAR 415 Volt in repairs Naturally air cooled Double dielectric heavy duty, MPP type 440 Volt 50 HZ Watt Less Power Capacitors wattage not more than 0.5 Watt per KVAR conforming to IS 13340 and 13341 ISI Marked all as specified.
All as per item No 80.00 above but Power Capacitors of Rating 20 KVAR 415 Volt
All as per item No 80.00 above but Power Capacitors of Rating 15 KVAR 415 Volt
All as per item No 80.00 above but Power Capacitors of Rating 10 KVAR 415 Volt
All as per item No 80.00 above but Power Capacitors of Rating 7.5 KVAR 415 Volt
All as per item No 80.00 above but Power Capacitors of Rating 5 KVAR 415 Volt
All as per item No 80.00 above but Power Capacitors of Rating 2 KVAR 415 Volt
Supply and fix in repairs power factor controller relay 8 Stage RPM 8, 415 volts, 50 cycles suitable for manual / automatic operation with indication for each stage, power factor adjustment setting knob / screw, display.
M & L for testing of APFC panel for proper functioning in manual & auto mode, including re-wiring the burnt out wires, replacing the wiring ducts/casing Capping, fuse units and cleaning and testing complete all as specified and directed.
Supply and Fix in replacement of Contactor Three Pole 415 volts 25 Amps AC 3 Rating including add on Blocks suitable for driving POWER Capacitors, including making addition/Alternation to existing Wiring/circuit system
All as per item No 89 above but Contactor Three Pole 415 volts 40 Amps AC 3 RatingConforming to Type - MNX - 40 & Cat no - CS94190 of L & T or equivalent.
All as per item No 89 above but Contactor Three Pole 415 volts 70 Amps AC 3 Rating Conforming to Type - MNX - 70 & Cat no - ST19002 of L & T or equivalent.
M & L for dismantling carefullly fly wheel ring of 250 KVA DG Set and supply and fix new wheel ring to match the grooves of starter of existing model complete and testig for satisfactorily functioning.
S & F in replacement solenoid switch for control of fuel governor, operation in 12 Volts DC supply as per existing model fixed complete all as specified and as directed by the Engineer-In-Charge.
M & L for dismantling fuel level indicator pipe and supply and fix new PVC heavy duty white transparent pipe to botton and top fuel level knob and mark the levels of fuel tank including two nos. jublee clips of suitable size all as specified and as directed by Engineer-In-Charge.
M & L for servicing Fuel injection pump of 200/ 250 KVA DG Set by striping off complete and cleaning each part in volatile liquid cleaner / petrol removing scales, cleaning, injector, spray nozzle including replacement of wornout parts such as injector heads including re-calibration from authorised service centre for smooth functioning etc. including testing and refixing in the same position all as specified and as directed by Engineer-In-Charge.
M&L for dismantling existing unserviceable radiator and carrying out repair by draining out water/coolant,carring out pressure test and rectifying leakage by brezing/soldering test and reinstalling including filling fresh coolant (approx 60 ltrs) all as directed and specified for 250 Kva DG set
M&L for dismantling existing unserviceable exhaust pipe of 200KVA/ 320KVA/ /250 KVA DG set and supply and fix new exhaust pipe of exiting model complete including lapping asbestos rope making good all disturbed surface area to match the surrounding
S & F in repair to Generator controller panel display meter for 200 KVA DG Set as per existing make all as directed.
S&F Battery Charger 230 V, AC Input and 24 Volt DC out put suitable for AMF panel as per exising make complete all as specified and directed by Engineer-In-Charge.
S & F new movable battery charger for battery charging purpose of the DG Set as a back up in case of any failure to the panel for the uninterrupted DG supply all as specified and as directed by Engineer-In-Charge.
S & F in replacement of Power contactor current rating 200A fixed complete all as specified and as directed by the Engineer-In-Charge.
S & F in replacement of Power contactor current rating 300A fixed complete all as specified and as directed by the Engineer-In-Charge.
S & F in replacement of Power contactor current rating 400A fixed complete all as specified and as directed by the Engineer-In-Charge.
M&L for provn of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 1.5M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification.
M&L for Spray painting of canopy of DG set of size from 200 to 315 KVA from outside with good quality enamel paint including cleaning with suitable cleaning agent, rubbing with emery paper, finishing, filling with putty for smoothness complete all as specified and directed.
Supply and Fix in repairs 230 Volts push buttons complete of colour red/ green with NO/NC elements including taking down old u/s complete.
S & F in repairs 230 Volts indication lamp complete(R Y B ) for mounting on LT panel including taking down old u/s complete.
M & L spray painting inside, outside complete to the LT panel boards outdoor type of size not exceeding 2.0 Mtr width 2.5 mtr in height and 0.75 mtr in depth with single coat of synthetic enameled paint of superior quality and approved colour after preparation of steel surface.
S&F cast iron covers, circular, for overhead PVC / RCC water storage tanks of any size, with MS strip / flat iron framework, with all necessary fixing and locking arrangements, nuts, bolts, washers, all as per BMC standards, with a shop coat of primer, including all necessary scaffolding / staging as required to cater at heights, taking out and disposing off old PVC covers, making any required addition / alteration to the tank for fixing of new CI covers, etc. complete all as specified, as directed by the Engineer-in-charge. (weight of tank cover not less than 10 KG). Make : As per sample
Dismantling unserviceable chemical dosing pump and replace with capacity of flow 10 LPM at max 5 Kg/cml pressure, 240 V, 50 Hz, complete with suction straner, pipe and dosing pipe including testing complete all as specified and directed. Make : Declibac Technologies pvt Ltd / Raclod / Milton Roy
Supply, fixing, jointing and testing of 80 mm, CI Sluice Valve heavy duty PN 1.6 with iron wheel head jointing, coupling both ends for cast iron pipes including nuts, bolts, rubber gaskets etc including taking down old unserviceable sluice valves complete all as specified and directed.
-Ditto- all as per item No 112.00 above but 100 mm bore
S & F foot valve of size 80mm dia cast iron body, ball type, with flanged and drilled ends and synthetic rubber coated MS ball, conformimg to relevant IS, ISI marked, including all joints, gaskets, bolts and nuts, washers, including taking up/down old unserviceable valves from any position and any addition/alteration for fixing required complete all as specified and directed by the engineer in charge.
M & L for dismantiling the existing valve chamber of size 900 X 900 X 900 mm including necessary earth work in any type of soil, PCC foundation D-2 1:3:6 in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 6 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made-out of 40 X 40 X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all metal works including necessary excavation earth work all plastered surfaces of valve chambers complete all as specified and directed by Engr-in-Charge.
S & F in repairs float ball valve assembly 20 mm bore , high pressure grade, with polythene float, fly nuts, screwed to GI pipe or brass ferrule, CI fittings viz. nipples, check nuts, reducers, elbow, sockets, etc. fixed complete all as specified and as directed by the Engineer-in-charge for the following bores of pipes:
-Ditto- all as per item No 116 above but 25 mm bore
-Ditto- all as per item No 116 above but 40 mm bore
M & L for servicing of Centrifugal pump set upto 20 HP by taking to workshop and opening end covers, greasing the bearings, replacing worn out nut, bolts, gasket, air release valve key, gland stuffing box male/ female set, Rubber bush and painting one coat of synthetic enamel paint, including writing/marking in 1" size letters SM & MES No and reinstalling in existing foundation complete with testing all as specified and directed by Engr-in-Charge. Note :- (i) Parts if required for pump shall be measured and paid separately here-in-after under another item as 'supply only.
-Ditto- all as per item No 119 above but Pump set 5 HP
Supply and adding Calcium hypo chlorite 65% -70% chlorine content granular based water disinfectent in sealed containers complete all as specified and as directed.Brands having pan india availability, acceptability & being manufactured /processed in open market termed as traditional products .The brands /makes must have certified by All India Institute of Hygenic & Public Health. Note-: The chemical shall be brought in three lot and period to be procured only before previous batch completed.
Material and labour for taking out unserviceable burnt out electric monoblock/centrifugal motor with pump from the foundation of pump capacity 25 HP, 440 Volts, 50 Hz by opening/diconnecting all mechanical and electrical connection and transporting to nearest work shop and rewinding the same by using approved make super enamelled insulation copper wire of suitable insulation class of approriate size after pulling out burnt out copper wires from the sloths of stator including replacement of minor accessories like mica paper, sleeves, glass fibre, bamboo pieces etc inlcuding varnishing/heating at heat chamber suitably and opening the monoblock pump assy for replacement of unserviceable parts maintaince and reassembling all as per existing complete and taking back the whole pump sets to its original location and fixed or placed suitabley including making the electrical and pipe connection including testing to get satisfactory result complete all as specified and as directed. Note: (i) Parts if required for pump shall be measured and paid separately here-in-after under another item as 'supply only.
M&L for chemical potability test for water before and after cleaning / desiliting waterby authorised chemical laboratory ,BMC approved. Test result to be submitted in duplicate all as specified and directed
M& L for attending day to day complaint of minor nature including replacement of fittings such as elbow,socket,tee etc and deposting the complaint slip in complaint cell after user signature complete as per directed by engineer in charge.
Mannual Rescue and Operation Rescue of water supply installation with all connected equipments, electric driven pump set, 10,000 Gph, supply lines and machineries (as listed herein under) and internal and external electrification, external water supply system, sumps, overhead reservoirs, service tanks, etc with one operator / technician operation for 02 shifts/per day, (08 hours each shift) including Sundays and holidays including routine maintenance checks and upkeeping the installation and with the under laid components complete all as specified and as directed by the Engineer-in-charge. Location: Thane (a) Pumping set centrifugal type of capacity 12 litres/sec with 38 m head with electrically driven induction motor 15HP, 3 phase- 02 No. (b) Chemical dozing plant with injection assembly booster pump with induction motor of 1.5HP, 3 phase - 01 No. (c) Vertical type pressure filter of capacity 1000 glns/hr including blower unit with induction motor 5HP, 3 phase - 01No (d) LT electric control panel with all accessories and components - 02 Nos
Note : (a) In case any operator is missing or absent from duty, a penalty of Rs 650/- per shift shall be recovered from any of dues of the contractor and the Engr-in-Charge decision shall be final and binding on this account. (b) The operator shall keep the paints, machineries and valve chamber surrounding area clean and tidy. (c) Contractor shall provide uniform and necessary tools required by the men employed by him. (d) Contractor shall submit the details of payments and wages for staffs employed through Aadhar link bank account Nos for payment purpose. (e) Painting of the equipments of pumps as required and existing to be done once in a year as per the directions given by the Engineer in Charge.
M & L in replacement of PVC Service Water Tank including tank nipple, bends, sockets complete all fitting required at site all including taking down the existing tanks as specified and directed by Engineer-in-Charge of 500 Ltrs capacity. Make : Legrand / L&T/Havells
-Ditto- all as per item No 126 above but 1000 Ltrs capacity.
-Ditto- all as per item No 126 above but 2000 Ltrs capacity.
Taking up or down steel water tubing of upto 50 mm bore and connections including cleaning and setting a side for refixing, etc complete all as specified and directed by the engineer-in-charge.
Supplying, laying, connecting and testing of GI tubing med gde of 25 mm dia with and including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions,etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post all as specified and directed by Engineer-in-charge.
-Ditto- all as per item No 131 above but 40 mm dia.
-Ditto- all as per item No 131 above but 50 mm dia.
-Ditto- all as per item No 131 above but 80 mm dia.
-Ditto- all as per item No 131 above but 100 mm dia.
M&L for dismantling overhauling ,packing and refixing of 5 HP, 3 Phase motor after opening carefully and stripping all parts cleaning removing defective burnt winding . Rewinding the motor with super enamelled copper conductor of the existing guage and number of turns as per the original winding pattern of the manufacturer varnishing with quick dry varnish drying it properly oiling and greasing of moving parts ,assembling , reinstalling testing on completion all as directed
Material and labour for carrying out vaccum test, pressure test and detecting leakage rectifying the leak and charging the refrigerant (R-22) complete for Tower/split/window type A/C of any capacity Note : (i) Job includes dismentling equipment from any site, height and transporting to workshop if necessary and reinstalled in situ and testing (ii) Above Job to be guaranteed for minimum one year
--ditto -- all as per item No.136 but for water cooler of any capacity
--ditto -- all a s per item No.136 above but suitable for refrigertor/ deep freezer of any capacity
M & L for repairs to base/body/stand of water cooler of any capacity by cutting out rusted portion, replacing with new M.S sheet of existing gauge including finishing wall surface and painting complete body of water cooler of any capacity Note :- Job includes dismantling equipment transporting to workshop and back included' re-installing in situ.
Supply and fix in repairs chasis made out of 2mm thick MS sheet suitable for 1.5 TR/ 2.0 TR capacity window type AC including dismantling accessories and re-installing on new chasis, painting complete body and required parts incld connection with new wiring etc all as directed
Material and labour for servicing of A/C window type or split type A/C, tower AC of capacity 1.5/2/2.5 TR including washing with sodash the cooling coil/condensor coil base body drying with air blower checking complete wiring testing and re-installing in situ and testing the unit.
M & L for dismentling unserviceable compressor from the window type AC, Split type A/C 1.5 TR/ 2.0 TR capacity from any location , supply and fix new hermatically sealed compressor unit , assembling, brazing pressure/vaccum testing initial oil charging, gas charging,reinstalling A/C in situ and connecting to electric supply and testing all as directed and specified. Make : Voltas/Carrier/Kirloskar /bluestar Note : (i) Job including removing A/C from any site/height/location (ii) Transporting A/C unit to repair workshop and back to site (iii) Loading/unloading etc
--ditto -- all as per item 142 above but suitable for refrigerator 165 to 320 ltrs capacity
--ditto -- all as per item 142 above but suitable for water cooler 40 t0 150 ltrs capacity
--ditto -- all as per item 142 above but suitable for deep freezer of 200 to 500 ltrs capacity
Supply and fix in repair AC fan motor for window/split type A/C of 1.5/2 TR ,Tower AC 2.5 TRcapacity single phase 230 volt 50 HZ complete with fan blade/blower including any addition/alteration to suit new fitting of motor.
--ditto -- all as per item 146 but for Water cooler any capacity
--ditto -- all as per item 146 but for deep freezer any capacity
Supply and fix in repair Relay for A/C split/window type,Tower AC
Supply and fix in repair Relay for WATER COOLER/DEEP FREEZER
Supply and fix in repair Thermostat for A/C 1.5 TR/2 TR,Tower AC
-ditto- all as per item No 151 but for water cooler of any capacity
Supply and fix in repair Air filtter for window type/split type AC, Tower AC as per sample
Supply and fix in repair Starting capacitor 80-100 mfd 220 volt 50 HZ
Supply and fix Starting capacitor of capacity 120 - 150 MFD for 2 TR, 2.5 TR capacity
Supply and fixing in repair of Running capacitors of capacity 45 MFD 220 volt 50Hz complete all as specified and directed by Engr-in-Charge
-ditto- all as per item No 156 but 36 MFD
-ditto- all as per item No 156 but 6 MFD
-ditto- all as per item No 156 but 4 MFD
Supply and fix in repair 3 core 4 sqmm flexible cable PVC insulated sheathed copper 1100 volts grade.
Supply and fix in repair 3 core 2.5 sqmm flexible cable PVC insulated sheathed copper 1100 volts grade.
Supply and fix in repair earthed metal clad socket outlet with earthed plug top 20 Amps capacity with sheet metal enclosure and one 20 Amps MCB SP all as specified and directed. Make : Legrand / L&T/Havells
M & L for power point wiring with PVC insulated sheathed copper wire 4 Sqmm size 1100 volts grade IS-654 in and including PVC casing and capping with all accessories including one run of 2.5 Sqm earth lead wire all as directed and specified.
Supply and fix in repair copper tube of size 6mm bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge
Supply and fix in repair copper tube of size 10 mm bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge.
Supply and fix in repairs 8mm dia hand shut off valve
Supply and fixing in repair and testing fan blade of motor for water cooler of 80/100/120/150 Ltrs capacity including removing old fan blade.
Supply and fixing in repair and testing fan blade suitable for window type Air conditioner of 1.5 Ton/2 Ton capacity including removing old fan blade.
Supply and fix in repairs front grill as per sample suitable for window type AC 1.5 TR/2 TR capacity.
Supply and fixing in repair of blower drum suitable for window type Air concitioner of capacity 1.5Ton /2TON.
Supply and fix in repair stainless steel tank of capacity 40 ltrs capacity water cooler of existing size shape
--do-- all as per item No 171 but 80 ltrs capacity
--do-- all as per item No 171 but 120 ltrs capacity
Supply and fix in repair waste water tray suitable for single/double tap with waste hose.
Supply and fix in repair PVC float valve wih PVC ball suitable for 15mm dia
Supply and fix in repairs bibtap push type stainless steel 15mm dia
Supply and fix in repairs gun metal gate valve with iron wheel head screwed both ends for iron pipe of size 20mm.
Supply and fix in repairs gun metal gate valve with iron wheel head screwed both ends for iron pipe of size 15mm.
Supply and fix in repairs remote sensor kit with Manual control pendent suitable for split type A/C,Tower AC 1.5 TR to 2.5 TR capacity work on 230 volt SP 50 HZ
Supply and fix base tray suitable A/C 1.5/2 TR made out of 2mm thick of existing size and shape including painting one coat zine chrome red oxide and two coats of synthetic enamelled paint
Supply and fix in repairs ventury and blower drum suitable for A/C window type 1.5 TR/2 TR as per existing model, size, and shape
Supply and fix in repairs condensor coils suitable for 1.5 TR to 2.5 TR capacity including dismentling old one brazing, testing, leakage rectification all as directed.
Supply and fix in repairs cooling coil suitable for 1.5 TR to 2.5 TR A/C of existing model including taking out old defective coil, brazing work, brass charging to full pressure
Supply and fix in repairs thermal over load relay 415 volts 66 - 110 Amps rating MMX R-4 model
Supply and fix in repairs thermal over load relay 415 volts 32 - 50 Amps rating MMX R-4 model
M&L in repair for wall mounted powder coated MS bracket suitable for 1.5TR/2TR Split type AC, Towre AC 2.5 TR out door unit
M&L for repair of rubberised insulation and tape for copper tubes of size 6mm/10mm.
M&L in repair sub main wiring with two single core PVC-FRLS insulated unsheathed multistranded copper conductor cable of size 4 sqmm drawn in PVC casing caping with 4 Sqmm PVC-FRLS insulated unsheathed multistranded copper conductor as a continuous earth wire complete all as specified. Note : (i) Two single core cable one run of earth copper conductor & one run of PVC casing & caping will be measured and paid as one unit length.
S&F in repair of building Security light fitting 35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge. Make :- Crompton/ Havells/ Bajaj/ Phillips
S&F in repair of Street light fitting made up of pressure die cast alluminium body with mid power 60 Watt LED (PINNACLE PLUS) as lighting sources and PC cover having Top opening seperate driver compartment with IP66 protection Including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge. Make :- Crompton/ Havells/ Bajaj/ Phillips
cooltech engineering services
shakti engineering and electrical works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .