| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST QUOTED RATES | |
| 2 | L2₹80.6 L+₹9.2 L (12.9%)Rejected-AOC SHOP NO 9 KHALSA SCHOOL MARKET MODEL TOWN PHAGWARA | L2 | Rejected-AOC HIGHEST QUOTED RATES |
Tender Value
₹68.7 L
EMD Value
₹1.4 L
Closing Date
20 Oct 2023, 10:00 amClosed
SH. HARMANPREET SINGH DIVISIONAL ENGINEER
DIVISIONAL ENGINEER OPERATION AND MAINTENANCE DIVISION PWRMDC ZILLA PARISHAD COMPLEX MALL ROAD HOSHIARPUR
DRILLING AND DEVELOPMENT, PUMP HOUSE, D-TANK BARBED WIRE AND ENERGISATION OF 02 NO. DEEP TUBWELLS AT VILLAGE RAMPUR-97 AND THAKKARWAL OF MAHILPUR BLOCK IN DISTRICT HOSHIARPUR (UNDER 72 5 NO. ALT. DEEP TUBEWELL NABARD PROJECT
2023_WR_110514_1
NITNO.60/2023/OPM/PWRMDC/DT. 05-10-2023.
Open Tender
Drilling Works
Item Rate
180 days
HOSHIARPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
Yes
₹1.4 L
Yes
2 Jan 2024
6 Oct 2023
20 Oct 2023
6 Oct 2023
20 Oct 2023
6 Oct 2023
Amount
A) Drilling, Development, Over Development of Works etc.
Drilling of 600mm dia bore with reverse rotatry rig in all kinds of soil including the cost of consumable stores,fuel oil and transportation of rig to the sit. Complete in all respect Tubewell Rampur-97 of Mahilpur Block Distt. Hoshiarpur (Zone-B)
(a) From 0 to 150 Meter.
(b) From 150 to 275 Meter.
Supplying,lowering of MS pipe as per IS :4270:2001 including MS socket having dimensions as per IS code duly welded with MS electrode to have extra strength to lower pipe into tubewell bore. (Zone-B)
(i) 300mm nominal diameter (weight 62.3 kg per metre) 8.00 mm thickness
(ii) 200mm nominal diameter ( weight 41.6 kg per metre) 8.00 mm thickness
Supplying, fixing and lowering of stainless steel cage type wire wound screen as per IS 8110-2000 or latest with ISI marked duly wellded with suitabe grade SS welding electrode to lower the strainer into tubewell bore 200mm dia Stainless Steel 8mm thick Strainer (Zone-B) "
Supplying, Fixing and lowering of Stainless Steel Socket as per IS 8110-2000 or latest ISI marked duly welded with suitable grade SS welding electrode. to lower the strainer into tubewell bore (Zone-B) 200mm diameter
Supplying, Lowering & fixing of M.S. Special Socket to connect S.S. Strainer to M.S. Pipe duly welded with suitable grade welding electrode complete in all respect (Zone-B) 200 mm internal diameter
Supplying and fixing of bail plug of MS pipe complete with invertor U-Block attached to the bttom plug complete in all respect (Zone-B) 200mm internal diameter (weight 41.6 kg per metre ) 8.00mm thick
Providing and fixing M.S. Taper/Reducer made out of 6mm thick sheet complete in all respect. M.S. Reducer 300 x 200mm dia.
Supplying and fixing Mild Steel Centering guides madeout of 32mm X 6mm thick M.S. bar complete in all respect. Center guide 300 x 200mm dia.
Supplying and fixing of well cap having thread to fix on housing pipe complete in all respect. Top well cap 300mm dia.
Supplying and fixing of MS Clamp of size 300mm X 12mm made out of MS flat 1.52m long, suitable to fit housing pipe including the cost nut and bolts of suitable size complete in all respect (Zone-B) M.S. Clamp 300mm dia.
Supplying at site wooden box of suitable size with lid and locking arrangement for preserving strata sample collected from the bore.
Making temporary water supply arrangement for drilling of tubewell with reverse rotary rig till completion of bore and packing of gravel. Depth of temporary bore upto 90 mtr
Supplying at T/well site of gravel of 1/16” to 1/8” including pouring and packing in the annular space between the pipes assembly and the bore. The gravel should be free from , dust , dirt, or the vegetable manner as per IS :4097/1967 with latest amendments (to be paid as per actual length of pipe). For proper approved size from Zirakpur/Ghagger quarry to site of work.
Making electric logging of bore hole with electronic well logger including cost of equipment at site etc. complete in all respect.
DEVELOPMENT AND OVER DEVELOPMENT CHARGES.
(a) Development and stabilizing of the T/well with Air Compressor of required capacity as directed by engineer-in charge including cost of tools, appliances and consumable to the satisfaction of engineer-in-charge. Capacity of air compressor 300 cfm at 250 PSI
(b) Development and stabilizing of the Tubewell with submersible pump of required capacity as directed by the Engineer- in – charge including the cost of tools , appliances and consumable to the satisfaction of engineer-in-charge.
Drilling of 600mm dia bore with reverse rotatry rig in all kinds of soil including the cost of consumable stores,fuel oil and transportation of rig to the sit. Complete in all respect Tubewell Thakkarwal of Mahilpur Block Distt. Hoshiarpur (Zone-A)
a) From 0 to 150 Meter
b) From 151 to 190 Meter
Supplying, lowering of MS pipe as per IS :4270:2001 including MS socket having dimensions as per IS code duly welded with MS electrode to have extra strength to lower pipe into tubewell bore (Zone-A)
1) 300mm nominal diameter ( weight 62.3 kg per metre) 8.00 mm thickness
2) 200mm nominal diameter ( weight 41.6 kg per metre) 8.00 mm thickness
Supplying, fixing and lowering of stainless steel cage type wire wound screen as per IS 8110-2000 or latest with ISI marked duly wellded with suitabe grade SS welding electrode to lower the strainer into tubewell bore 200mm dia Stainless Steel 8mm thick Strainer (Zone-A)
Supplying, Fixing and lowering of Stainless Steel Socket as per IS 8110-2000 or latest ISI marked duly welded with suitable grade SS welding electrode. to lower the strainer into tubewell bore (Zone-A) 200 mm diameter
Supplying, Lowering & fixing of M.S. Special Socket to connect S.S. Strainer to M.S. Pipe duly welded with suitable grade welding electrode complete in all respect (Zone-A) 200 mm internal diameter
Supplying and fixing of bail plug of MS pipe complete with invertor U-Block attached to the bttom plug complete in all respect (Zone-A) 200mm internal diameter (weight 41.6 kg per metre)8.00mm thick
Providing and fixing M.S. Taper/Reducer made out of 6mm thick sheet complete in all respect (Zone-A) M.S. Reducer 300 x 200mm dia
Supplying and fixing Mild Steel centering guides madeout of 32mm X 6mm thick M.S. bar complete in all respect (Zone-A) Center guide 300 x 200mm dia
Supplying and fixing of well cap having thread to fix on housing pipe complete in all respect (Zone-A) Top well cap 300mm dia
Supplying and fixing of MS Clamp of size 300mm X 12mm made out of MS flat 1.52m long, suitable to fit housing pipe including the cost nut and bolts of suitable size complete in all respect (Zone-A) M.S. Clamp 300mm dia
Extra material/items required for installation of one no. deep t/well (Zone-A)
Supplying at site wooden box of suitable of size with lid and locking arrangement for preserving strata sample collected from the bore
Making temporary water supply arrangement for drilling of tubewell with reverse rotary rig till completion of bore and packing of gravel (Zone-A) Depth of temporary bore upto 90 mtr
Supply at query site of gravel of 1/16” to 1/8” including pouring and packing in the annualar space between the pipes assembly and the bore. The gravel should be free from , dust , dirt, or the vegetable manner as per IS :4097/1967 with latest amendments (to be paid as per actual length of pipe). For proper approved size from Ghaggar (Zirakpur) quary to site of work.139 Avg. Km) S/o gravel (Zone-A)
Making electric logging of bore hole with electronic well logger including cost of equipment at site etc. complete in all respect (Zone-A)
DEVELOPMENT AND OVER DEVELOPMENT
Development and stabilizing of the t/well with Air Compressor of required capacity as directed by engineer-in charge including cost of tools, appliances and consumable to the satisfaction of engineer-in-charge (Zone-A) Capacity of air compressor 300 cfm at 250 PSI
Development and stabilizing of the tubewell with submersible pump of required capacity as directed by the Engineer- in – charge including the cost of tools , appliances and consumable to the satisfaction of engineer-in-charge (Zone-A)
Construction of Pump House Size 10'x8' and 11' ht. with 9'' thick walls with brick masonary in 1:7 Cement Sand Mortor, RB Slab 1:2:4, 6'' thick with brick plumbing, cement plaster 1:6, 12.5 mm thick on walls, cement plaster 1:4, 12.5 mm thickness on ceiling, cement pointing 1:3 deep variety outside the pump house, as per approved drawing Tubewell Rampur of Mahilpur Block Distt. Hoshiarpur (Zone-B)
Construction of D-Tank as per approved drawing with brick masonary 1:5 in cement sand mortor in foundation and above plinth level, with cement plaster 1:3, 12.5 mm thickness on walls inside, cement plaster 1:4 , 12.5 mm thick outside D-Tank (Zone-B)
Construction of barbed wire fencing around the pump house & D-Tank as per approved drawing (Zone-B)
Construction of Pump House Size 10'x8' and 11' ht. with 9'' thick walls with brick masonary in 1:7 Cement Sand Mortor, RB Slab 1:2:4, 6'' thick with brick plumbing, cement plaster 1:6, 12.5 mm thick on walls, cement plaster 1:4, 12.5 mm thickness on ceiling, cement pointing 1:3 deep variety outside the pump house, as per approved drawing Tubewell Thakkarwal of Mahilpur Block Distt. Hoshiarpur (Zone-A)
Construction of D-Tank as per approved drawing with brick masonary 1:5 in cement sand mortor in foundation and above plinth level, with cement plaster 1:3, 12.5 mm thickness on walls inside, cement plaster 1:4 , 12.5 mm thick outside D-Tank (Zone-A)
Construction of barbed wire fencing around the pump house & D-Tank as per approved drawing (Zone-A)
Supplying, Fixing & Installation of Pumping set and Control Panel & Lowering Material etc.
Submersible pumping set of 75 H.P. ISI Marked
Submersible pumping set of 50 H.P. ISI Marked
Three Core Submersible Flat Cable 25 sqmm. ISI Marked
Three Core Submersible Flat Cable 16 sqmm. ISI Marked
Control panel complete 75 H.P.
Control panel complete 50 H.P.
MS pipe (heavy) (IS:1239/3589/4270), 100 mm i/d 5.40 mm thick.
Supplying and Fixing M.S. flange 4 “ dia , 5/8” thick , outer dia. 190 mm with 4 no. holes and 2 no. cuts
M.S. nut & bolt of all sorts
M.S. Lead clamp of 100 mm dia
MS Flat for Jali
PVC Insulator four core cable for connection from Transformer to Control Pannel
Supplying and Fixing of well cap to fix on housing pipe complete in all respect-300mm internal diameter ZONE-B
Supplying and Fixing of well cap to fix on housing pipe complete in all respect-300mm internal diameter ZONE-A
M.S. bend 4” 90 degree , 5 mm thickness, leg length 40 cm ,flange thickness 15 mm , 6 no. holes
Providing & fixing C.I/D.I flanged end , stem of SS (AIS 1410) & Bronze ( gunmetal) working parts sluice valves ISI maked 14846-2000 , including jointing, Testing & cost of Nut, bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge) .Class PN-1 as per ISI 100 mm i/d Sluice Valves flanged. ZONE-B
Providing & fixing C.I/D.I flanged end , stem of SS (AIS 1410) & Bronze ( gunmetal) working parts sluice valves ISI maked 14846-2000 , including jointing, Testing & cost of Nut, bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge) .Class PN-1 as per ISI 100 mm i/d Sluice Valves flanged. ZONE-A
PVC copper wire 19/16 ISI marked
PVC copper wire 7/22 ISI marked
T/well provision soldier thimble, flexible pipe , copper earth plate, G.I. pipe 1" dia, G.I. wire, internal electrification & Double earthing, kitkat, rubber jain etc.
M.S clamp 4" dia. for 13 mm thick M.S sheet APS
Labour for lowering of pumping set Zone-B
Labour for lowering of pumping set Zone-A
Any other item as per CSR+ZP
CNC Precision Engineering
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .