Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.7 L+₹22,032 (1.52%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹16.6 L+₹2.1 L (14.8%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹21.0 L+₹6.5 L (44.8%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹24.0 L+₹9.5 L (65.6%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
7 Aug 2023, 6:00 pmClosed
Kislay Kishore, IDSE
GE (AFA) Hyderabad PIN-500043
Repair to internal electrical wiring in Tech area
2023_MES_608548_1
8351/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AFA) Hyderabad
As per tender pages
4 documents required · 4 mandatory
₹500
GE (AFA) Hyderabad
₹50,000
Yes
16 Sept 2023
10 Jul 2023
9 Aug 2023
10 Jul 2023
7 Aug 2023
24 Jul 2023
10 Jul 2023 - 23 Jul 2023
Amount
Taking down carefully un serviceable point wiring of light points, fan, socket out let on TW battens/PVC pipes/casing & caping including removing the materials from site and making good the disturbed portion of walls/floors ceiling etc including painting/colour washing/distempering complete all as per existing specification of the surroundings complete all as specified and as directed.
M&L for cutting chases, pinning in. making good to facings on brick wall / stone, concrete block where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth including painting/colour washing/distempering complete all as per existing specification of the surroundings complete all as specified and as directed.
M & L for Point wiring with 1.5 Sqmm multistranded copper conductor wire with unsheathed, FRLS grade PVC insulated, single core with earth continuity conductor of 1.5 sqmm FRLS grade PVC insulated multistranded copper conductor and including rigid PVC conduit of suitable size but not less than 20mm dia. and all accessories fixed to the surface of the roof/ walls or in chases etc. including terminal boxes made out of MS sheet of thickness should be not lessthan 1.2mm thick for fixing of switches, fan regulators socket outlet etc along-with 3mm thick top laminated bakelite sheet for housing switches, etc complete all as specified and as directed for the following :-
(a) One light point controlled by one switch
(b) One light point controlled by two nos 2 way switches
(c) One ceiling / Exhaust fan point controlled by one switch
(d) One three pin socket 5 Amps independent with 1.5 sq mm coppper conductor
(e) One Bell point controlled by one way bell switch
(f) One three pin socket 5 Amps plug point on same board
M & L for Point wiring with 1.5 Sqmm multistranded copper conductor wire with unsheathed, FRLS grade PVC insulated, single core with earth continuity conductor of 1.5 sqmm FRLS grade PVC insulated multistranded copper conductor and including rigid PVC Casing & capping of suitable size and all accessories fixed to the surface of the roof/ walls or in chases etc. including PVC terminal boxes for fixing of switches, fan regulators socket outlet etc. complete all as specified and as directed for the following :-
(a) One light point controlled by one switch
(b) One light point controlled by two Nos, 2 way switches
(c) One ceiling / Exhaust fan point controlled by one switch
(d) One three pin socket 5 Amps plug point independent
(e) One Bell point controlled by one way bell switch
(f) One three pin socket 5 Amps plug point on same board
All as per Ser item No 3 above but with 2.5 sq mm multistranded copper wire with 2.5 Sq mm multistranded copper wire as earth continuity conductor in and including PVC conduit (not less than 20 mm) complete all as specified and as directed for 15A socket.
All as per Ser item No 10 above but with 2.5 sqmm copper cable in the casing & capping complete all as specified and as directed 15A socket.
S&F in repairs of ceiling rose, three terminal, PVC/polycarbonate, insulated body, ISI marked complete all as specified and as directed.
S&F in repairs 2 way switch ISI marked complete all as specified and as directed.
S&F in repair of Switch Piano type polycorbonate white 1 way, 6A, 240Volts complete all as specified and as directed.
S&F in repair of Bell Switch flush type polycorbonate white 6A 240Volts complete all as specified and as directed.
S&F in repair of Socket outlet polycorbonate white 6A - 2/3 pin complete all as specified and as directed.
S&F of Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 flush type universal complete all as specified and as directed.
S&F in repairs of Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 flush type universal complete all as specified and as directed.
S&F of Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and as directed.
S&F in repair of Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and as directed.
S&F in repair of Switch 15 Amp flush type universal complete all as specified and as directed.
S&F in repair of Socket out let polycorbonate white 2 in 1, 3 pin, 15 Amp flush type universal complete all as specified and as directed.
S&F in repair of Bell Multi Music type / Ding Dong AC 230 V complete all as specified and as directed.
S&F of 22cms (9inch) dia Gong Bell, round shaped of operating rated voltage single phase 220V to250V, to be fixed on wall including connections complete all as specified and directed by Engineer-in-Charge.
S&F in repair of stepped type polycorbonate white electronic fan regulator flush type complete all as specified and as directed.
S&F in repair of polycarbonate white angle holder/batten holder insulated complete all as specified and as directed.
S&F in repair of PVC Gang Box suitable for 5Amps Switch Socket Combination complete all as specified and as directed.
S&F in repair of PVC Gang Box suitable for 15Amps Switch Socket Combination complete all as specified and as directed.
S & F in repair modular switch 6 Amp one way 230 V AC complete all as specified and as directed.
S & F in repair modular switch 16 Amp one way 230 V AC complete all as specified and as directed.
S & F in repair modular switch 6 Amp bell push, 230 V AC complete all as specified and as directed.
S & F in repair modular socket outlet 6Amp intel multi socket for all pins 230 V AC complete all as specified and as directed.
S & F in repair modular socket outlet 16Amp and 6/16 Amp heavy duty 230 V AC complete all as specified and as directed.
S & F in repair modular step type fan regulator heavy duty 230 V AC complete all as specified and as directed.
Supply & Fixing 1x10W LED Tube light fitting having housing with high pressure die cast alluminium, poly carbonate front diffuser cover including LED driver, Lamp and all accessories internally pre-wired, connecting up with three core twisted flexible copper conductor cable with cross sectional area 1.0 Sqmm including taking out old unserviceable one complete all as specified and as directed. Make- Luker Cat No- LT510P or equvalent
S&F surface mounting / wall mounted LED tube light fitting 1x20 Watt (Lumen output not less than 1980 lumen) high efficiency, anti glare, maintenance free operation including LED driver, Tube 20W/18W and mounting arrangements, all accessories internally pre-wired, connecting up with three core twisted flexible copper conductor cable white colour with suitable size including taking out old unserviceable one complete all as specified and as directed. Make- Luker Cat No- LT520P or equvalent
S&F LED street light luminaries 35W 230 V AC including suitable inbuilt driver and complete accessories with MS housing finished & having clear acrylic cover, and provision of 1.20 mtr bracket made with light grade GI pipe of 25 mm dia for fixing on walls with MS flat (25mm X 3mm) clamps and anchorfastner after removing the unserviceable fitting complete all as specified and as directed. Make- Luker Cat No LST- 36 or equvalent
S&F flush / surafce type light fittings of size 600x600mm suitable for 36W LED complete with inbuilt driver surface mounted/recessed type slim box type luminaries with CRCA housing white powder coated finish suitable to operate with 230 V AC, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with cross sectional area 1.0 Sqmm after removing old U/S rusted fittings complete all as specified and as directed. Make- Luker Cat No-LKM 2236 or equvalent
S&F flush surface/rcessed type light fittings square / round as per site requirement suitable for 18 W LED complete with inbuilt driver surface mounted slim box type luminaries with CRCA housing white powder coated and finish suitable to operate with 220 V AC complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size after remove old U/S rusted fittings complete all as specified and as directed. . Make- Luker Cat No- LNPR18 or equvalent
S&F laminated hylum sheet 3 mm thick with suitable chromium plated machine screws with cup washers for fixing switches/ sockets etc including cutting for accommodating the switches / sockets and removing the damaged switch plates by carefully removing the switches /wiring/ sockets for refixing and re connecting the removed wires testing the circuits complete all as specified and as directed.
Taking out old unserviceable MCB and S&F of single pole and neutral enclosure with a two pin and earth plug and socket complete with one number single pole MCB 20 Amps , 240 Volts complete all as specified and as directed.
M&L for Sub Main wiring with four runs of 10sq mm 1100 V grade (nominal area) single core FRLS grade PVC insulated unsheathed wire with multi-stranded copper conductor, drawn through and including medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable size with all necessary fittings, surface in walls/roof/floor duly earthed with two runs of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed.
Note :- (i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
(ii) Same size wire shall be used for phase, neutral & earth conductor
(iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
(iv) Six runs of cable and one run of PVC conduit / casing caping will be measured as one length.
M&L for Sub Main wiring with two runs of 6sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable sizewith all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed.
Note:-(i) Necessary PVC dummy plates & rigid PVC junction boxes for maint./inspection purpose as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
(ii) Same size wire shall be used for phase, neutral & earth conductor
(iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
(iv) Three runs of cable and one run of PVC conduit / casing caping will be measured as one uint.
M&L for Sub Main wiring with two runs of 6sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through existing conduit with all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed.
Note:-(i) Necessary PVC dummy plates & rigid PVC junction boxes for maint./inspection purpose as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
(ii) Same size wire shall be used for phase, neutral & earth conductor
(iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
M&L for Sub Main wiring with two runs of 2.5sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable sizewith all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed.
Note:-(i) Necessary PVC dummy plates & rigid PVC junction boxes for maint./inspection purpose as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
(ii) Same size wire shall be used for phase, neutral & earth conductor
(iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
(iv) Three runs of cable and one run of PVC conduit / casing caping will be measured as one uint.
M&L for Sub Main wiring with two runs of 2.5sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through existing conduit with all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed.
Note :- (i) Necessary PVC dummy plates & rigid PVC junction boxes for maint./inspection purpose as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
(ii) Same size wire shall be used for phase, neutral & earth conductor
(iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
M&L for Sub Main wiring with two runs of 4sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable sizewith all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed.
Note:-(i) Necessary PVC dummy plates & rigid PVC junction boxes for maint./inspection purpose as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral & earth conductor (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads. (iv) Three runs of cable and one run of PVC conduit / casing caping will be measured as one uint.
Taking out old unserviceable distribution board of any type and S&F of MCB DB SPN 4 way with copper bus bar & neutral link double door type to be fixed in the wall including connections and making good the disturbed surface of wall to perfectly match with the exsting wall complete all as specified and as directed.
Taking out old unserviceable distribution board of any type and S&F of MCB DB SPN 8 way with copper bus bar & neutral link double door type to be fixed in the wall including connections and making good the disturbed surface of wall to perfectly match with the exsting wall complete all as specified and as directed.
Taking out old unserviceable distribution board of any type and S&F of MCB DB SPN 12 way with copper bus bar & neutral link double door type to be fixed in the wall including connections and making good the disturbed surface of wall to perfectly match with the exsting wall complete all as specified and as directed.
Taking out old unserviceable distribution board of any type and S&Fof MCB DB double door 4 way triple pole vertical type 415 volts 50 Hz AC supply suitable for 4 pole MCCB incomer, fixed to the existing wall (concealed/surface) after removing the existing un serviceable MCB DB and reconnecting the electrical connections and making good the disturbed surface of wall to perfectly match with the exsting wall complete all as specified and as directed.
Taking out old unserviceable distribution board of any type and S&F of MCB DB,,double door 8 way triple pole vertical type 415 volts 50 Hz AC supply suitable for 4 pole MCCB incomer, fixed to the existing wall (concealed/surface) after removing the existing un serviceable MCB DB and reconnecting the electrical connections and making good the disturbed surface of wall to perfectly match with the exsting wall complete all as specified and as directed. Note : MCCB will be measured and paid separately under relavant items.
Taking out old unserviceable distribution board of any type and S&F of MCCB 4 pole 63Amps, 16KA breaking capacity, 415Volts 3-phase supply complete all as specified and as directed.
Taking out old unserviceable distribution board of any type and S&F of MCCB 4 pole 100Amps, 16KA breaking capacity, 415Volts 3-phase supply complete all as specified and as directed.
Taking out old unserviceable MCB any type and S&F of MCB SPN 6 to 32A, 10KA rupturing capacity complete all as specified and as directed.
Taking out old unserviceable MCB any type and S&F of Fix MCB SP 6 to 32 A 10 KA rupturing capacity complete all as specified and as directed.
Taking out old unserviceable distribution board of any type and S&F of MCB TPN 40 to100 Amps,10KA breaking capacity, 415Volts complete all as specified and as directed.
Supply and Fixing LED Flood Light 1x50W with integral driver with heat resistant well glass including necessary wiring with 2 core PVC sheathed weather proof flated alluminum conductor complete all as specifed and directed by Engineer-in-Charge.Make- Luker Cat No-LFLSL50NSG or equvalent
S&F flush picture light 1x12 W LED complete with inbuilt driver luminaries with CRCA housing white powder coated and finish suitable to operate with 220 V AC complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. .Make-Luker Cat No- LMCL12 or equvalent
S&F high intensity LED revolving search light with stand Energy saving, long rang, 150w beam range 400 meters IP 66, high luman> 140lm/w,PF>0.95,CCT: 5000K-6500K CRI>70, optical grade PMMA/PC Lens reflector, efficiency >95% operating rated voltage single phase 220V to 250V complete all as specified and directed by Engr-in -Charge. Make- Kalin Model No- CS-LRFLL25-PC15 or equvalent
AKSHITA ELECTRICAL
M.chandraiahsons
SRI SAI CONSTRUCTIONS
S J REDDY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .