Tender Value
₹2.8 Cr
EMD Value
₹5.6 L
Closing Date
29 Apr 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
+ Capital Works)
S AND T
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of SGCC, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
(a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing.
Defination of Similar Work :- "Any indoor or combined indoor & outdoor signaling work including design, supply, installation, testing & commissioning of electronic interlocking system for passenger carrying lines". OR "Any indoor or combined indoor & outdoor signaling work including supply, installation, testing & commissioning of Relay interlocking (RRI/PI) system/ABS/IBS for passenger carrying lines".
6 conditions · 4 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The bid must comply technical conditions of tender.
Replacement of indoor interlocking Signalling gears of Chandni (CDI) Panel by Electronic Interlocking on BSL division
BSL-N-SNT-02-2026-27
BSL-N-SNT-02-2026-27
Open
Works - General
6 Months
Jalgaon, Maharashtra
₹0
₹5.6 L
29 Apr 2026
6 Apr 2026
15 Apr 2026
346 items across 5 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 78,83,783.27 | ||
| — | 1.00 | — | — | ||
| Supply of tool kit- required for Trouble Shooting and repair of hardware and software for EI system should be supplied for stations as per schedule item 1 above. ( This includes tools required for EI maintenance sorts of crimping, insertion,removal, general purpose tools like screw drivers, spanners, PCB extractor, temp. controlled soldering iron, wire cutter,nose plier etc. & measuring instruments with carrying case/ holders/ cabinet for technicians/ J.E. for testing, Maintenance and repair at site). Each set comprises of the following :- (a) Crimping tool for all types of special cable assembly used in EI system. (b) Insertion tool for all types of special cable assembly used in EI system. (c) Removal tool for all types of special cable assembly used in EI (d) Digital multimeter Tektronics/Fluke /MEGGER / RISHAV or better) system. (e) Steel cabinet/ Almira (Godrej/Durian/Transteel) of good quality to store tool, spare cards and documents. (f) Clamp Earth Tester. (Fluke 287/MEGGER/RISHAV or better) (g) Clamp Current Meter. (Fluke 87/ MEGGER/ RISHAV or better) (h) 6 nos, Electrostatic Discharge Wrist Band for cards/modules protection." (Inspection by Consignee) | — | — | — | 1,21,963.39 | |
| — | 1.00 | — | — | ||
| Supply of as made documents (Manuals for Installation,Testing, and maintenance of the system) (One set consists of 6 set of following drawings per Station). (i) Manual for installation, Testing, Commissioning and maintenance of the system for Technicians/Jr. Engineers. Installation and maintenance level)(ii) Functioning and system overview (Higher Management Level)(iii) Completion documents as per special conditions of contract. (iv) Design & Supply of circuits and plans to suit layout given in the signalling plan for Hot Standby Architecture Electronic Interlocking (EI) system. All plans and wiring diagram shall be prepared on Autocad Drawing and supplied with CD. This will include supply of Control-cum-Indication Panel/VDU diagram, Square Sheet,Wiring Diagrams (Application Logic and Interface Circuit), Fuse Analysis, Contact Analysis, Tag Block Analysis, Power Supply Distribution / Power Equipment arrangement (with program switch) Diagram, Auto Change over diagram (if supplied by the contractor), and all other relevant drawings. NOTE : The contractor shall initially supply 1 set of documents (Paper Prints) for approval of Railways. He shall ensure that each sheet has a block for signature of Railway Official as well as a block for signature of firm, duly signed by the authorised signatory of the firm. The name of the work as given by Railways shall be written on every sheet under the work column. All the drawing shall be supplied in a good quality folder for each station. After approval of documents by Railways, the contractor will make copies of the approved documents and return the approved document to Railways. The contractor will then make necessary correction to Application Logic Software duly incorporating Railways' alterations/corrections/ comments, if any. After complete testing/ commissioning of the station, tracings of completion documents as mentioned above will be submitted to Railways for approval. Along with the completion application logic, difference report (showing addition & deletion in different colours) as compared to earlier approved application logic should also be submitted. After approval of completion application logic by Railways, 5 sets of copies of duly approved completion tracings will be submitted to Railways." (Inspection by Consignee) | — | — | — | 1,54,817.56 | |
| — | 1.00 | — | — | ||
| Supply of Portable work station for data input & configuration with necessary software/Autocad latest Version rogrammes/ Accessories,simulation and function Testing,diagnostics and trouble shooting and commissioning of EI system.Suitable Table & chair of reputed make shall be supplied by the contractor.The specfications of the PC/Laptop should be got approved from the engineer in charge before supply .Note:Portable work station should strictly adhere to specification as per annexure-I. (Inspection by Consignee) | — | — | — | 1,70,923.82 | |
| — | 3.00 | — | — | ||
| Supply of Relay Rack Assembly complete with scaffolding, fixtures and accessories including MS Bars for fixing of relay plug board, string rods, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on C. Rly. Typical part list as per Annexure-II and Rack arrangement as per Sketch no SK-727 and Rack plan as approved by Engineer incharge. (Inspection by Consignee) | — | — | — | 94,666.8 | |
| — | 20.00 | — | — | ||
| Supply of Tag Blocks 200 / 160/120 way with polycarbonate cover as per IRS S 77- 2006 (Rev 1 ) RDSO DRG. NO SA 24751, SA 24752 & SA 24753 Requirement of each type shall be specified by Engineer incharge. (Inspection by RDSO) | — | — | — | 25,295.22 | |
| — | 5.00 | — | — | ||
| Supply of Main Cable Termination rack complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, insulators, J bolt, nut/bolts & fasteners, backelite sheet, etc. Siemens type and as per extant practice on Central Railway. Typical part list as per Annexure-III and rack arrangement shall be as per sketch No. SK-727 with latest alterations. (Inspection by Consignee) | — | — | — | 1,35,890.68 | |
| — | 1.00 | — | — | ||
| Supply of Data logger for monitoring status of important relays, complete with Processor Module to monitor following inputs as per spec. RDSO/SPN/99/2006 Spec No : IRS S- 99/2006(Amdt -3) with latest amendments including power supply of adequate capacity, battery and fault diagnostic software for failure analysis. Complete data logger & Processor Module(computer) as per Annexure-IV shall be placed in President rack of suitable size to be supplied. This also includes supply of one no composite computer & printer table (Godrej/Durian/Transteel work station table ) for keeping Processor module and one no Godrej/Durian/Transteel make operator chair model 1024 digital and 32 analog inputs. (Inspection by RDSO) | — | — | — | 6,42,712.98 | |
| — | 0.50 | — | — | ||
| Supply of PVC Indoor Cable 1x60x0.6mm dia colour coding of insulation of inner core shall be in six colour Viz Blue , Red , Grey ,Green, Brown and Black conforming to IRS 76/89(Amdt 3) or latest.(Inspection by Rites) | — | — | — | 1,34,387.05 | |
| — | 0.50 | — | — | ||
| Supply of PVC Indoor Cable 1x 40x0.6mm dia. Colour coding of insulation of inner core shall be in eight colour viz Blue,Red,Grey,Green,Brown,Black, Yellow & white.conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by Rites) | — | — | — | 88,161.07 | |
| — | 1.00 | — | — | ||
| Supply of PVC indoor cable 1 x 24 x 1 mm dia. Colour coding of insulation of inner Conductor shall be in eight colour viz Blue,Red,Grey,Green,Brown,Black, Yellow & white.conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by Rites) | — | — | — | 2,61,588.91 | |
| — | 3.00 | — | — | ||
| Supply of Indoor Jumper Wire of various colour as per Railways standard practice of type ATC 1 x 0.6 mm dia.conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by Consignee) | — | — | — | 23,190.56 | |
| — | 2.00 | — | — | ||
| Supply of Indoor Jumper Wire ATC 1 x 1 mm dia. conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by Consignee) | — | — | — | 23,408.63 | |
| — | 1.50 | — | — | ||
| Supply of PVC Flexible Copper Cable, Single core, multi strand 1x2.5 sq mm(50 conductor each dia 0.25 + /- 0.01) as per specn IS 694/2010 with latest amendment. If any with insulation thickness of 0.70 mm nominal conductor resistance 7.98 ohms /km and test parameters are as per IRS (S)76/89 (Amdt .3). (Inspection by Rites) | — | — | — | 59,769.26 | |
| — | 1.00 | — | — | ||
| Supply of PVC Flexible Copper Cable, Single core, multi strand 1x6 sq mm(84 conductor each dia 0.30 + /- 0.01) as per specn IS 694/2010 with latest amendment. If any with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms /km and test parameters are as per IRS (S)76/89 (Amdt .3). (Inspection by Rites) | — | — | — | 81,896.71 | |
| — | 2.00 | — | — | ||
| Supply of PVC Flexible Copper Cable, Single core, multi strand 1x10 sq mm(80 conductor each dia 0.40 + /- 0.01) as per specn IS 694/2010 with latest amendment. If any with insulation thickness of 1.00 mm nominal conductor resistance 1.91 ohms /km and test parameters are as per IRS (S)76/89 (Amdt .3). (Inspection by Rites) | — | — | — | 2,52,185.82 | |
| — | 1.00 | — | — | ||
| Supply of PVC Flexible Copper Cable, Single core, multi strand 1x16 sq mm(126 conductor each dia 0.40 + /- 0.01) as per specn IS 2465/1984 & IS:694/2010 with latest amendment. If any with insulation thickness of 1.00 mm nominal conductor resistance 1.121 ohms /km and test parameters are as perIRS (S)76/89 (Amdt .3). (Inspection by Rites) | — | — | — | 1,87,654.91 | |
| — | 1.00 | — | — | ||
| Supply of PVC Flexible Copper Cable, Single core, multi strand 1x25 sq mm(196 conductor each dia 0.40 + /- 0.01) as per specn IS 2465/1984 & IS:694/2010 with latest amendment. If any with insulation thickness of 1.2 mm nominal conductor resistance 0.780 ohms /km and test parameters are as per IRS (S)76/89 (Amdt .3). (Inspection by Rites) | — | — | — | 2,91,604.9 | |
| — | 10.00 | — | — | ||
| Supply of wire 16/0.2(blue,red,gray,yellow,brown,black,white as per site engineer instruction)finolex/polycab/delton make.IRS:S-76/89(Amd.3),BS:4808 Part-2.Wire to be procured from RDSO approved vendor. (Inspection by Consignee) | — | — | — | 57,613.37 | |
| — | 4.00 | — | — | ||
| Supply of Transformers 230V/110V-130V Single Phase 2 KVA as per spec IRS S-72/88 (Amd.2)with latest amendments. (Inspection by RDSO) | — | — | — | 38,890.87 | |
| — | 4.00 | — | — | ||
| Transformers Rectifier Unit 110V AC/24V DC 500mA as per specn.No.CR/S&T/91-12 (Inspection by RDSO) | — | — | — | 4,628.04 | |
| — | 1.00 | — | — | ||
| Supply of Battery Charger self regulating floor mounting type with 230 V AC Single phase input and output 60V DC,40A as per spec.IRS.S.86/2000(Amd.4)with latest amendment. (Inspection by RDSO) | — | — | — | 1,16,921.83 | |
| — | 1.00 | — | — | ||
| Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 110 V DC, 40A as per spec. IRS.S.86/2000 (Amd.4) with latest amendments. (Inspection by RDSO) | — | — | — | 83,867.66 | |
| — | 4.00 | — | — | ||
| Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 24V DC,30A as per spec.IRS.S.86/2000(Amd.4)with latest amendments. (Inspection by RDSO) | — | — | — | 1,14,750.59 | |
| — | 2.00 | — | — | ||
| Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 24V DC,30A as per spec.IRS-S-86/2000(Amd.1)with latest amendments for Axle counter application(Amd.4).(Inspection by RDSO) | — | — | — | 1,06,766.34 | |
| — | 1000.00 | — | — | ||
| Supply of Rubber Mat 5 mm thick for use in signalling installation. (Inspection by Consignee) | — | — | — | 1,15,786.87 | |
| — | 1.00 | — | — | ||
| Supply of Auto changeover panel for 3 incoming supply single phase with manual bypass arrangement along with MCBs, switches, voltage sensing relays, fuses etc.of repute & approved make of suitable rating.The panel should be made up of 16 SWG powder coated MS sheet. General arrangement & scheme to be in line with RDSO spec. and approved by Engineer incharge and as per RDSO Specn.No . TI/SPC/CLS/0023 with A & C Slip No. EN-13600 with the plated surface, or latest amendments.CAPACITY 63 Amps. (Inspection by RDSO) | — | — | — | 73,185.89 | |
| — | 20.00 | — | — | ||
| Supply of QNA1 AC immunized relay 8F-8B,24VDC along with plug board, retaining clip and connectors conforming to BRS:931A,IRS:S60,IRS:S34 & IRS:S23 . (Inspection by RDSO) | — | — | — | 68,872.31 | |
| — | 10.00 | — | — | ||
| Supply of QN1 Non AC immunized natural relay 8F-8B,24VDC along with plug board, retaining clip and connectors conforming to BRS:930, IRS:S60,IRS:S34 & IRS:S23 . (Inspection by RDSO) | — | — | — | 36,028.28 | |
| — | 5.00 | — | — | ||
| Supply of QN1 Non AC immunized natural relay 12F-4B,24VDC along with plug board, retaining clip and connectors conforming to BRS:930, IRS:S60,IRS:S34 & IRS:S23 . (Inspection by RDSO) | — | — | — | 18,346.67 | |
| — | 5.00 | — | — | ||
| Supply of QNN1 Twin natural relay 24VDC 4F-4B/5F-3B/6F-2B contacts,complete with plug board, retaining clip and connectors BRS:960. (Inspection by RDSO) | — | — | — | 28,975.9 | |
| — | 13.00 | — | — | ||
| Supply of QSPA1relay, 24VDC,Slow to pick up, 8F.4B along with plug board, retaining clip and connectors conforming to BRS:933A,IRS:S60,IRS:S34 & IRS:S23. (Inspection by RDSO) | — | — | — | 51,304.58 | |
| — | 35.00 | — | — | ||
| Supply of QTA2 AC immunised track relay, 9 Ohm,2F.1B, along with plug board,retaining clip and connectors conforming to BRS:939A, 966, & appendix F2, IRS:S34& IRS:S23. (Inspection by RDSO) | — | — | — | 1,20,760.26 | |
| — | 2.00 | — | — | ||
| "Supply of QBAT track Relay, AC immunised, 2F-2B contacts, 9 ohms. complete with plug board, retaining clip & connectors as per RDSO / SPN/84 ver 2.0 or latest."(Inspection by RDSO) | — | — | — | 11,806.26 | |
| — | 20.00 | — | — | ||
| "Supply of Universal LED Lamp proving relay QECX61 relay, 4F-4B,AC conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 ,Amdt.-1 (FOR ALL ASPECT ECR FOR AC LED SIGNAL) (Inspection by RDSO) | — | — | — | 66,578.39 | |
| — | 10.00 | — | — | ||
| "Supply of QBCA1 AC immunised relay, 2FHD 4F-4B,24VDC along with plug board,retaining clip and connectors conforming to BRS:943 POINT CONTACTOR RELAY. And IRS S46. & firms specification." (Inspection by RDSO) | — | — | — | 42,341.9 | |
| — | 11.00 | — | — | ||
| Supply of QL 1 LATCH relay, 11 F-4B or 8F-6B along with plug board , retaining clip and connectors conforming to BRS:935A (Inspection by RDSO) | — | — | — | 46,576.09 | |
| — | 5.00 | — | — | ||
| "Supply of QNNA1- AC immunised relay, 6F- 2B,24VDC along with plug board,retaining clip and connectors conforming to BRS:960, IRS:S60,IRS:S34 & IRS:S23. (Inspection by RDSO) " | — | — | — | 18,348.15 | |
| — | 5.00 | — | — | ||
| "Supply of QNNA1- AC immunised relay, 4F-4B,24VDC along with plug board,retaining clip and connectors conforming to BRS:960, IRS:S60, IRS:S34 & IRS:S23. (Inspection by RDSO) " | — | — | — | 22,480.42 | |
| — | 5.00 | — | — | ||
| "Supply of Relay & plug board QNNA1 /24V, QNNAI1,2 X 6F-2B along with plug board,retaining clip and connectors conforming to BRS:960, IRS:S60, IRS:S34 & IRS:S23. (Inspection by RDSO) " | — | — | — | 23,095.56 | |
| — | 25.00 | — | — | ||
| "Supply of QNA1K relay 1000 ohm,6F/6B 24V DC as per BRS :931A, IRS:S60, IRS:S34 & IRS:S23 and RDSO spec. STS/ E/ Relays/UEA (PI) dtd.30.05.1997 Annexure II. (Inspection by RDSO) " | — | — | — | 92,696.09 | |
| — | 25.00 | — | — | ||
| "Supply of Relay & plug board QN1 /50V/ 8F-8B Metal to carbon DC neeutral-BRS:930, IRS:S60, IRS:S34 & IRS:S23. " (Inspection by RDSO) | — | — | — | 1,17,083.02 | |
| — | 2.00 | — | — | ||
| Supply of Block filter unit as per IRS:S-68/89 and Block bell equipment as per IRS:TC- 44/88 (Amdt.1). (Inspection by RDSO) | — | — | — | 45,304.23 | |
| — | 2.00 | — | — | ||
| "Supply of Block Bell equipment as per RDSO Drg.No. TCA 15080 and Specn. No. IRS- TC-44/88 (Amd.1) with amendment No. 1 Voltage 24 V DC. (Inspection by RDSO) " | — | — | — | 6,575.65 | |
| — | 2.00 | — | — | ||
| Supply of Wooden block counter of size 700mm x 700mm W X 900mm H made of teak wood frame and 12mm thick water proof ply with formica finish on top and all four sides having two compartment inside and two doors on opposite sides as per drg no RST/C/110 (Inspection by Consignee) | — | — | — | 25,830.26 | |
| — | 2.00 | — | — | ||
| Supply of Desk type Electronic Magneto Telephone as per spec No IRS TC- 79/2000 (Amdt 4 )or with latest amendments. (Inspection by Consignee) | — | — | — | 5,869.4 | |
| — | 1.00 | — | — | ||
| "Supply of Test Board & Circuit progress board for relay room as per Drg No RST/C/105 A&B. (Inspection by Consignee) | — | — | — | 11,227.29 | |
| — | 280.00 | — | — | ||
| — | — | — | 2,142.5 | ||
| — | - Supply | of PPTC Circuit.Make:LITTLEFUSE,FUZETEC,TYCO,BOURN,RAYCHEM | Consignee) | ||
| — | 280.00 | — | — | ||
| Supply of PPTC Fuse GP 250-185UL-94 Certification (24V/4A)TPR .Make:LITTLEFUSE,FUZETEC,TYCO,BOURN,RAYCHEM etc. (Inspection by Consignee) | — | — | — | 2,142.5 | |
| — | 1.00 | — | — | ||
| "Supply of Resisters, condensers, Diodes, LEDs and lugs alongwith bracket and mounting arrangement as per standard Annexure-V of Central Railway. (Inspection by Consignee) " | — | — | — | 49,645.85 | |
| — | 6.00 | — | — | ||
| "Resin cored wire as per specification No. IS:1921-1975 with Alloying element percentage as 63% SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony) 0.2% maximum , Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement." (Inspection by Consignee) | — | — | — | 6,718.09 | |
| — | 52.00 | — | — | ||
| Lacing thread rolls, black, wax coated (100 mtrs). (Inspection by Consignee) | — | — | — | 3,074.84 | |
| — | 20.00 | — | — | ||
| Design,fabrication and supply of fuse Auto changeover system for 32 Nos of external non detorating Type fuses of G type fuses from 0.6 A Amp to 4A Amp capacities used in signalling circuits.System shall have 8 cards with monitoring arrangement of 4 fuses in one card.As per RDSO spec.RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (Inspection by RDSO) | — | — | — | 4,78,419.39 | |
| — | 2.00 | — | — | ||
| Design,fabrication and supply of fuse Auto changeover system for 24 Nos of external non detorating Type fuses of G type fuses from 4 A to 10 Amp capacities generally used for point operation circuits.System shall have 6 cards with monitoring of 4 fuses in one card.As per RDSO spec.RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (Inspection by RDSO) | — | — | — | 72,429.82 | |
| — | 6.00 | — | — | ||
| Supply of FIBRE GLASS INSULATING FIRE RETARDENT SHEET of 10 mm THICKNESS AS PER ISO:10192-1982,Dielectric strength -25KV/mm with glass content 25 to 34%, in standard size of 1.10x1.10Mtr.as per spec.No.IS:10192-1982. (Inspection by Rites) | — | — | — | 28,426.02 | |
| — | 4000.00 | — | — | ||
| Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741 Alt.4., SA-23745 Alt 5, SA-23746, SA-23748 Alt -4 & SA-23756 Alt-3. (Inspection by RDSO) | — | — | — | 2,59,624.32 | |
| — | 200.00 | — | — | ||
| Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4,SA- 23749 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. (Inspection by RDSO) | — | — | — | 29,130.41 | |
| — | 200.00 | — | — | ||
| Supply of round head type non detoriating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments 2A/4A/6A capacity. (Inspection by RDSO) | — | — | — | 12,537.84 | |
| — | 6.00 | — | — | ||
| Supply of Tik-tak, piano type switches,5 A (As per IS specification). (Inspection by Consignee) | — | — | — | 179.19 | |
| — | 20.00 | — | — | ||
| Supply of Apparatus Case with godown locks with deatachable handle on both the doors. (i) Single Case as per Drg No SK 783-1&2. with latest alteration. (Inspection by RITES) | — | — | — | 2,86,406.45 | |
| — | 5.00 | — | — | ||
| Supply of Apparatus Case with godown locks with deatachable handle on both the doors. (ii) Half Case as per Drg No SK 783-1&2. with latest alteration. (Inspection by RITES) | — | — | — | 57,450.68 | |
| — | 6.00 | — | — | ||
| Supply of earth electrode assembly as per drg.No.CR/S&T /SK/815. (Inspection by RDSO) | — | — | — | 5,782.17 | |
| — | 1.00 | — | — | ||
| A CLASS EARTHING-Supply of ESR ALTEC TERRA STREAMER Lighting Arrester with SS adaptor (TSP30,50 Mtr.Radius)SPN:NFC-17-102-2011. (Inspection by RDSO) | — | — | — | 56,205.79 | |
| — | 1.00 | — | — | ||
| Supply of FRP mast with GI Mast(FRP mast at top minimum 1.5 Mtr.along with GI mast 3 Mtr.) Total 4-5 Mtr.std mast required for mounting the terminal & adaptor to mount the Air terminal with coupler / reducer.Multi strand stray wire,joints,clamps & accessories as per IS 2309:1989. (Inspection by Consignee). | — | — | — | 8,371.92 | |
| — | 1.00 | — | — | ||
| Supply of Test Link joint Kit in a IP65 weather proof enclosure of suitable dimension and approved make & design. (Inspection by Consignee) | — | — | — | 2,153.74 | |
| — | 1.00 | — | — | ||
| Supply of Lighting Strike recorder LSC 6 digit shall be weather proof type.It should have 6 digit event count & the capacity to count smallest strike(3 KA).It should be voltage sensing type counter.So that it will register nearly strikes & static discharge due to induction effect as per IS 2309:1989. (Inspection by Consignee) | — | — | — | 13,183.11 | |
| — | 1.00 | — | — | ||
| Supply of UL listed long life Maintenance Free Earthing with constant performance service warranty UL listed.250 Micron with ALLTEC-Tera Fill TF 50 & TF-50 XT Back fill should RoHS & Low resisvity certified .The Back Fill having not more than 0.20 Ohm/cm resistance,eco friendly,non degradable and non soluble.The earthing pit shall be designed & supplied with Poly-plastic Pit cover non conductive,environment friendly. (Inspection by RDSO) | — | — | — | 11,537.9 | |
| — | 40.00 | — | — | ||
| Supply of Down conductor (recommended:70 Sqmm 19 strand copper insulated cable for lightning current dissipation to earth with necessary fixing clamp,connector accessories etc.) (Inspection by RDSO) | — | — | — | 15,384.02 | |
| — | 10.00 | — | — | ||
| Maintenance Free Earth As per RDSO/SPN/197/2008 or latest consisting of :1) Copper bond steel electrode 3 Mtr long 17 mm dia with copper bonding thickness of min.250 micron & UL listed & marked -01 No 2) Earth enhancement compound RDSO Approved in sealed bag of 10Kgs-03 No 3) Copper strip 150x25x6 mm -02 No 4) Copper strip 300x25x6 mm -01 No 5)35 Sqmm Copper Cable to connect earth electrod to MEEB-15 Mtr Approx. (Inspection by RDSO) | — | — | — | 1,58,992 | |
| — | 50.00 | — | — | ||
| Supply of 35 Sq. mm. multistrand single core PVC insulated copper for connecting earth bus bar to earth electrode. (Inspection by Consignee) | — | — | — | 18,160.92 | |
| — | 20.00 | — | — | ||
| Supply of Copper Tape 25x6 mm (Bonding ring conductor) mounted on insulated standoff (1 round). (Inspection by Consignee) | — | — | — | 14,220.16 | |
| — | 1.00 | — | — | ||
| "Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC. as per RDSO/SPN/256/2002 with latest amendments. (Inspection by RDSO) " | — | — | — | 1,30,175.57 | |
| — | 6.00 | — | — | ||
| Supply of Electronic timers for DAC reset arrangement 3 sec to 30 sec with 2 NO/2NC contact working voltage 24V/60V DC siemens/ABB/L&T or SELEC(642xA programmable electronic timer switch)make (Inspection by RDSO) | — | — | — | 15,120.93 | |
| — | 2.00 | — | — | ||
| Supply of Pre-wired Crank Handle cum key lock relay box(of metal) along with LEDs,with approved type push buttons,8-way terminal strips,string rod, etc as per Drawing No.RST.C.114 (Inspection by Consignee) | — | — | — | 18,713.96 | |
| — | 36.00 | — | — | ||
| Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT.1/2004 or latest with sockets and fittings.TATA/ JINDAL/ ZENITH BIRLA Make. (Inspection by Rites) | — | — | — | 33,123.93 | |
| — | 400.00 | — | — | ||
| Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4. (Inspection by Rites) | — | — | — | 73,707.42 | |
| — | 3000.00 | — | — | ||
| Supply of Modular Terminal block of 2.5 sqmm 2 IN 2 out type disconnect type terminal along with as per RDSO Specn.No.RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps & more,The terminal should have marking at centre to view description from front.Material to be procured from RDSO approved firm only. (Inspection by RDSO) | — | — | — | 3,14,080.7 | |
| — | 60.00 | — | — | ||
| Supply of DIN channel for the terminals 1 Mtr each. (Inspection by RDSO) | — | — | — | 11,624.1 | |
| — | 260.00 | — | — | ||
| Supply of End plates for modular terminal block. (Inspection by RDSO) | — | — | — | 5,436.16 | |
| — | 260.00 | — | — | ||
| Supply of End clamp for modular terminal block. (Inspection by RDSO) | — | — | — | 3,906.88 | |
| — | 30.00 | — | — | ||
| Supply of marker card as per customer spec(10x10). (Inspection by RDSO) | — | — | — | 2,247.53 | |
| — | 500.00 | — | — | ||
| Fuse links of (400mA,630mA,1 A,1.6 A,2A,4A,6.3A & 10A). (Inspection by Consignee) | — | — | — | 19,281.42 | |
| — | 2.00 | — | — | ||
| "Operating tool (operating tool, screw driver & stripper) as per Annexure-VII, (Inspection by Consignee) | — | — | — | 15,482.71 | |
| — | 30.00 | — | — | ||
| Supply of Adhesive Tapes rolls,PVC(18 mm x25 Mtr) Steel Grip/SCOTCH/ANCHOR. (Inspection by Consignee) | — | — | — | 898.37 | |
| — | 3.00 | — | — | ||
| Supply of thermo shrink Jointing kit (Reinforced) TSF-2 type generally conforming to R D S O Specification No.RDSO/SPN/TC/57/2015 Rev 1 with modified kit contents as per CSTE Specification No.CR/SPN/TC/57 (A)/2015 dtd 06.01.2015(Table -A) to be suitable for jointing both 10/20/50 pair PIJF and 4/6 Quad cables alongwith sub-kit(Table-B) for armour continuity. (Inspection by RDSO) | — | — | — | 8,023.57 | |
| — | 10.00 | — | — | ||
| "Supply of 4.5 kg CO2 type fire extinguisher along with all accesarios, extinguisher testing certificate has to be supplied along with. - Supply of ISI marked Carbon diOxide type (BC) fire extinguisher of 4.5 Kg capacity confirming to IS 2878: 2004 from seamless cylinder, with IS marked control value, high pressure mtr., Long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting braket etc. as required by site Engineer. "(Inspection by Consignee) | — | — | — | 44,866 | |
| — | 1.00 | — | — | ||
| — | — | — | 60,086.45 | ||
| — | Modular,1 with soft function,Remote least 2 1 panel lead of certified. | Suppy,Installation,Testing & Alarm Control Panel with loop (minimum 125 keys for displaying maintenance service different makes of addressable Monitored Sounder Output.It shall capable to operate acid maintenance free operating the system for (Inspection by RDSO) | Microprocessor to 2 should connected supply,automatic normal | ||
| — | 30.00 | — | — | ||
| Suppy,Installation,Testing & Commissioning of Analogue Addressable Multisensor Detector complying to RDSO/SPN/217/2019 Ver 3 or latest As per latest VDS approved/listed. (Inspection by RDSO) | — | — | — | 91,097.08 | |
| — | 1.00 | — | — | ||
| Suppy,Installation,Testing & Commissioning of Manual call points,complying to RDSO/SPN/217/2019 Ver 3 or latest As per latest VDS approved/listed. (Inspection by RDSO) | — | — | — | 4,672.05 | |
| — | 300.00 | — | — | ||
| Suppy,Installation,Testing & Commissioning of Resettable,Analogue Type Linear Hest Sensing(LHS) Cable complying to RDSO/SPN/217/2019 Ver 3 or latest As per latest UL or FM or VDS or LPCB approved/listed. (Inspection by RDSO) | — | — | — | 3,79,227.24 | |
| — | 200.00 | — | — | ||
| — | 1.00 | — | — | ||
| — | 1.00 | — | — | ||
| — | 2.00 | — | — | ||
| — | 300.00 | — | — | ||
| — | 2.00 | — | — | ||
| — | 0.20 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
CorrectionSlips_1.pdf
ATTACHMENT
GCC_IndianRailways-April-2022.pdf
ATTACHMENT
InspectionofSafety-CriticalSignalingItemsbyRDSORSDte26.09.2025.1_1.pdf
ATTACHMENT
C.RLYDRAWINGANNEXURES-SORST-20211_compressed.pdf
ATTACHMENT
CHANDNISIPREVB.pdf
ATTACHMENT
TenderDocuments.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .