| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹49.5 L+₹204.58 (<0.01%)Rejected-Finance | L2 | Rejected-Finance Quoted High | |
| 3 | L3₹49.5 L+₹425.78 (<0.01%)Rejected-Finance | L3 | Rejected-Finance Quoted High |
Tender Value
₹49.5 L
EMD Value
₹98,900
Closing Date
14 Nov 2022, 2:00 pmClosed
Divisional Forest Officer
Chirang Forest Division, Kajalgaon
Plantation of General Park alongwith 1 one Green House No.1 Smart fencing Athiabari Forestry under Bengtol VCDC, Sidli Block in Chirang Forest Division for the year 2022-23, Package No.CRD/ 2022-23/06
2022_BoTC_27556_1
CRD/04 of 2022-23
Open Tender
Civil Works - Building
Item Rate
180 days
Chirang
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
₹98,900
Yes
12 Dec 2022
2 Nov 2022
14 Nov 2022
2 Nov 2022
14 Nov 2022
2 Nov 2022
2 Nov 2022 - 14 Nov 2022
Amount
Construction of Office Room: Earth work in surface excavation not exceeding 30cm in depth but excluding 1.5m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50m, as directed by Engineer-in-Charge.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth level. (1cement: 3 coarse sand (Zone-III derived from natural source; 6 graded stone aggregate 20mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, beding, placing in position and binding all complete upto plinth level. Thermo-mechanically treated bars of grade FE-500D or more
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttress, plinth and string course, fillets, columns, pillars, piers, abutments, post and struts etc., above plinth level upto floor five level, excluding cost of centering, shuttering, finishing and reinforcement.(1cement: 3 coarse sand (Zone-III derived from natural source; 6 graded stone aggregate 20mm nominal size derived from natural sources)
(B) In super-structure
Centering and shuttering including strutting, propping etc. and removal of form for a) Foundations, footings bases of column etc.
b) Columns, pillars, piers, abutments, posts and struts
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in (b) In prop.1:4
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level.
Steel work in built upto tubular (round, square or rectangular hollow tubes etc) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes
Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers of G.I. limpet washer filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlaping of sheets complete. 0.63mm thick with Zinc coating not less than 275 gm/ sqm.
Providing ridges or hips of width 60cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, Bolts and Nuts 8mm dia G.I. limpet and bitumen washers complete. 0.63mm thick with Zinc coating not less than 275 gm/ sqm.
Providing wood work in frames of Doors, windows, clerestory windows and other frame, wrought framed and fixed in position with (hold fast lugs or with dash fastener shall be paid for separately). a) With Sal wood
Providing and fixing panelled or panelled for doods, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge (Note- Butt hinges and necessary screws shall be paid separately).
Cement concrete flooring 1:2:4 (1 Cement: 2 Coarse Sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and fixing MS grills of required pattern in frames of windows with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/ wooden frames with rawl plugs screws etc.
15mm cement plaster on rough side of single or half brick wall of mix: Rough side (1 cement : 4 coarse sand)
Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) Natural colour insulating board. 12mm thick
Painting with oil type wood preservative of approved brand and manufacture. Old work ( one or more coats)
Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surface free from mortar droppings and other foreign matter and including preparating the surface even and sand papered smooth
(b) Providing vitrified floor tiles of approved quality of specified size…........ as directed.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
For Internal and External Electrification (Wiring, Fand, bulb etc.)
Providing, fitting and fixing information board at work site.
GI Barbed Wire Fencing with Iron Gate Earth work in surface excavation not exceeding 30cm in depth but excluding 1.5m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50m, as directed by Engineer-in-Charge.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth level. (1cement: 3 coarse sand (Zone-III derived from natural source; 6 graded stone aggregate 20mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, beding, placing in position and binding all complete upto plinth level. Thermo-mechanically treated bars of grade FE-500D or more
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttress, plinth and string course, fillets, columns, pillars, piers, abutments, post and struts etc., above plinth level upto floor five level, excluding cost of centering, shuttering, finishing and reinforcement.(1cement: 3 coarse sand (Zone-III derived from natural source; 6 graded stone aggregate 20mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for a) Foundations, footings bases of column etc.
b) Columns, pillars, piers, abutments, posts and struts
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in (b) In prop.1:4
15mm cement plaster on rough side of single or half brick wall of mix: Rough side (1 cement : 4 coarse sand)
Providing and fixing 1.8m height GI barbed wire fencing with 2.4m RCC M15 grade 150mm x 150mm concrete post placed ever 3m centre-to-centre founded in M15 grade cement concrete, 0.6m below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with G.I. staples, turn buckles etc. complete as per clause 1705.
Supplying, fitting and fixing leaf heavy duty iron gate, frame made from 50mm x 6mm MS flat iron with another horizontal flat at the middle 20mm dia bars at 200mm apart from bottom flat to top flat and 20mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete.
Const. of Green house and Plantation of Orchid plants. Earth work in surface excavation not exceeding 30cm in depth but excluding 1.5m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50m, as directed by Engineer-in-Charge.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth level. (1cement: 3 coarse sand (Zone-III derived from natural source; 6 graded stone aggregate 20mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, beding, placing in position and binding all complete upto plinth level. Thermo-mechanically treated bars of grade FE-500D or more
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttress, plinth and string course, fillets, columns, pillars, piers, abutments, post and struts etc., above plinth level upto floor five level, excluding cost of centering, shuttering, finishing and reinforcement.(1cement: 3 coarse sand (Zone-III derived from natural source; 6 graded stone aggregate 20mm nominal size derived from natural sources)
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in (b) In prop.1:4
Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tube.
Supplying, fitting and fixing of Green net (As per market rate)
Supplying, Planting of Orchid plants
Construction of Latrine, Toilet and Water supply: Earth work in surface excavation not exceeding 30cm in depth but excluding 1.5m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50m, as directed by Engineer-in-Charge.
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth level. (1cement: 3 coarse sand (Zone-III derived from natural source; 6 graded stone aggregate 20mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, beding, placing in position and binding all complete upto plinth level. Thermo-mechanically treated bars of grade FE-500D or more
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttress, plinth and string course, fillets, columns, pillars, piers, abutments, post and struts etc., above plinth level upto floor five level, excluding cost of centering, shuttering, finishing and reinforcement. (1 cement: 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregatge 20mm nominal size derived from natural sources).
b) In superstructure
Centering and shuttering including strutting, propping etc. and removal of form for a) Foundations, footings bases of column etc.
b) Columns, pillars, piers, abutments, posts and struts
c) Edges of slabs and breaks in floors and walls.
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in (b) In prop.1:4
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level.
Providing wood work in roof truss, rafter, parlin, tie …. to MS straps. Second class teak wood
Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers of G.I. limpet washer filled with white lead, including a coat of approved paint on overlapping of sheets complete. 0.63mm thick with Zinc coating not less than 275 gm/ sqm.
Providing ridges or hips of width 60cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, Bolts and Nuts 8mm dia G.I. limpet and bitumen washers complete. 0.63mm thick with Zinc coating not less than 275 gm/ sqm.
Cement concrete flooring 1:2:4 (1 Cement: 2 Coarse Sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.
15mm cement plaster on rough side of single or half brick wall of mix: Rough side (1 cement : 4 coarse sand)
Providing wood work in frames of Doors, windows, clerestory windows and other frame, wrought framed and fixed in position with (hold fast lugs or with dash fastener shall be paid for separately). a) With Sal wood
Providing and fixing panelled or panelled for doods, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge (Note- Butt hinges and necessary screw shall be paid separately)
Painting with oil type wood preservative of approved brand and manufacture. Old work ( one or more coats)
Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surface free from mortar droppings and other foreign matter and including preparating the surface even and sand papered smooth.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
Internal and External electrification with 1/2 KW Motor for water tank.
Construction of Septic Tank Earth work in surface excavation not exceeding 30cm in depth but excluding 1.5m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50m, as directed by Engineer-in-Charge.
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth level. (1cement: 3 coarse sand (Zone-III derived from natural source; 6 graded stone aggregate 20mm nominal size derived from natural sources.
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in (b) In prop.1:4
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttress, plinth and string course, fillets, columns, pillars, piers, abutments, post and struts etc., above plinth level upto floor five level, excluding cost of centering, shuttering, finishing and reinforcement. (1 cement: 3 coarse sand (Zone-III) derived from natural source : 6 graded stone aggregate 20mm nominal size derived from natural sources)
Providing, fixing and fitting of H.C.I. Manhole cover (600mm x 450mm)
15mm cement plaster on rough side of single or half brick wall of mix: Rough side (1 cement : 4 coarse sand)
Installation of Tube Well : Supplying fitting and fixing Maya Hand pump No.6. For 40mm dia Tube well etc. ii) Mayur
Labour for sinking tube well with 40mm (internal) dia G.I. pipe upto having strata, having etc.
Providing of Tube Well platform with brick work, CC work plastering etc.
Supplying fitting and fixing Water Tank
500 Litre Water tank
Pipes fitting (PVC pipes, bends, junctions, Tee etc.
Earth filling: Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth breaking clods, watering, rolling each layer with 1/2 tonne roller or wooden or steel rammers and rolling every 3rd and top most layer with power roller minimum 8 tonne and dressing up in embankments for roads, floods banks, marginal banks and guide banks or filling up ground depression, lead upto 50m and lift upto 1.50m. All kinds of soil
Construction of Cement concrete pavement inside: Construction of sub-grade and earthen shoulder with approved materials obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope compacting to meet requirement of tables 300.2 with a lead upto 1000m as per technical specification clause 303.1. i) Private land
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification clause 401. (ii) For Grading II material.
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 Kn in stages to proper grade and camber, applying and brooming, stone screeing to fill up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification clause 405. (A) By Manual means.
Constructiodn of un-reinforced dowel jointed at expansion and const. of joint only, plain cement concrete pavement, thickness as per design, over a prepared sub-base, with 43 grade cement or any other type as per clause 1501.2.2 M30 grade, coarse and fine aggregate conforming to IS 383 maximum size of coarse aggregate not exceeding 25mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork, spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrator and finished.
Johnson Narzary
PROBONATH BORGOYARY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .