Amount
pH meter (with 5 years AMC) make Lovibond, EUTECH, WTW, OAKTON, Metrohm pH Range -2.00 to 16.00 pH Resolution/Accuracy 0.01 pH/± 0.01 pH ORP Range ± 2000 mV Resolution/Accuracy 1.1 (± 199.9 mV) / 1 mV (beyond) 1.2 ± 0.2(± 199.9 mV) /± 2 mV (beyond) Temp. range 0.0 to 100.00 C (32.0 to 212.00 F) Resolution/Accuracy 0.1 0 C(0.1 0 F)/±0.3 ºC / ±0.5 ºF (0 to 70 ºC) ATC Yes (0 to 100 0 C) Buffer Options USA: pH 1.68, 4.01, 7.00, 10.01,12.45 NIST pH 1.68, 4.01, 6.86, 9.18 ,12.45 No. of pH Calibration Points 5points Built-in Electrode Arm Yes Memory 100data sets Electrode Included ECFC7252101B,single junction pH electrode. Temp.Probe Included LCD DISPLAY CUSTOM dual-display LCD(5.6X7.5cm) Power Requirements Included, 100 /240VAC SMPS Power Adapter with US/UK/EUR/Japan plug ,9V,6W, CENTRE
Conductivity meter /TDS METER (with AMC for 5years) Make Lovibond,EUTECH, OAKTON, WTW, Hach, Metrohm Conductivity Range 0.01 to 200.0 mS/cm Resolution/Accuracy 0.01 / 0.1 μS ; 1 / 0.01mS / 0.1 mS ±1 % full scale Resistivity Range 2.000 Ω to 20.0 MΩ Resolution/Accuracy 0.01 / 0.1 Ω ; 0.001 / 0.1 kΩ ; 0.01 MΩ ±1 % full scale Salinity Range 0.0 to 80.0 ppt Resolution/Accuracy 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt ±1 % full scale TDS Range 0.050 ppm to 500 ppt (@ TDS factor 1.00) Resolution/Accuracy 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt Resolution/Accuracy 0.10 C (0.1 0 F); ±0.3 0 C(± 0.5 0 F) Temp. Coefficient Linear & pure ; 0.000 to 10.000 % Normalization Temperature 15.0 to 30.0 0 C (59.0 to 86.0 0 F) Built-in Electrode Arm Yes Compensation ATC / MTC Memory 100 data sets electrode Included, 2 cell epoxy body Conductivity electrode, K=1.0, Power Requirements Included, 100 /240VAC SMPS Power Adapter , 9V,6W
Turbidity meter (Benchtop)/ (Portable) (with amc for 5 years) Make Eutech, WTW, Hach, Oakton Accuracy: ±2% of reading plus 0.01 FNU/NTU from 0 - 1000 FNU/NTU Certifications: CE, KC, RCM Communication: USB Compliance: ISO Data logging: 2000 total logs, includes reading log, verification log and calibration log Display: 17.8 mm colour touch screen Interface: 2 USB-A ports for USB flash drive, external printer, keyboard and barcode scanner Light source: Light-emitting diode (IR LED) at 860 ± 30 nm Measurement method: Nephelometric Operating temperature range: 0 - 40 °C Power requirements (Voltage): 100 - 240 VAC Range: 0 - 1000 NTU NTU/FNU: 0 - 1000 Reading modes: Single, continuous, Rapidly Settling Turbidity, signal averaging on or off Regulatory: Meets ISO 7027, DIN EN 27027, DIN 38404 and NFT 9033 Repeatability: ±1% of reading or 0.01 FNU/NTU, whichever is greater (under reference conditions) Response time: Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average) Sample cell compatibility: Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used. Sample requirements: 25 mm sample cell: 20 mL minimum 0 to 70 °C (32 to 158 °F) Source Lamp: LED Stabilisation time: Immediately Storage conditions: -20 to 60 °C Units: FNU and NTU
Distillation plant Make Borosil, Glassco, All Quartz Double Distillation Unit Demountable Boiler Panel Series, Vertical Model with Distillation Apparatus Power Supply Capacity 2.5 Ltr/hr
Autoclave Vertical Make POPULAR ,NST, AMBASSDOR Size-78 ltr/ 98 ltr • It should have double wall construction with boiler made of Stainless Steel 16 gauge sheet. Outer shall is also made of Stainless Steel Sheet/ Mild Steel. Boiler and outer shell is provided with air insulation. Lid is made of Stainless Steel Sheet and tightened all-round by radial locking . Joint less gaskets are made of Neoprene rubber. These sterilizers are hydraulically tested upto 40 PSI. • Should have fully automatic PID Controller • Automatic timer electronic 999 mts • Sterilizers are fitted with water level arrangement to indicate water position inside the boiler. Pressure gauge, Air/Steam release cock two safety valve are also provided. The autoclave is fitted with indfoss pizzostat and can be set between 10 to 20 PSI. • Immersion type heating element heats the water and steam to desired temp. and pressure are attained. We have provided all autoclaves to cut-off automatically when the autoclave is dry. Supplied complete with S.S. basket, cord and plug to work on 220 Volts 50 cycles A.C. supply • Traceability calibration certificate of controller should be provided • Instrument should be calibrated from NABL calibration laboratory. • Includes AMC for 5 years
Hygrometer, Make HTC Temp.Range -500C ~ +700C Temp. Measuring Accuracy: ± 10C Temp. Resolution: 0.10C Humidity Meas.Range: 10% RH ~ 99% Humidity Accuracy: ±5% RH Humidity Resolution: 1%
Thermometer simple and with probe Make LT(Type k), Thomassci, Hanna Digital LCD Thermometer with sensor probe
Analytical Balance (with 5 years AMC) Make Radwag, Mettler Toledo, Sartorius,shimazhu Analytical Balance Capacity 220 gm Accuracy 0.01 mg with internal calibration Pan Size Ø 90 mm
Calibrated Weights Make Radwag, Mettler Toledo, Sartorius,denver,wensar Standard Weight Box Class F1 capacity 1 mg to 200 gm with NABL Accredited Lab Calibration Certificate (Set of 23 wire weights)
Desiccators Make Borosil, Glassco, Thermo 250 mm along with 1 kg silia gel (Qualigen)
Bacteriological incubator Nake NST,AMBASSADOR,OPTICS TECHNOLOGY Size 18x24x18.The incubator should have double door outer is metal door and inside is glass door in stainless steel frame. There will be glass window outside .Two adjustable air ventilators are placed near the top of the sides.The temperature is controlled by an Electronic microprocessed Temperature Controller cum Indicator from few °C above ambient to 70 deg. C with sensitivity of plus minus 0.5 deg. C supplied complete with two pilot lamps, aircirculating fan perforated shelves adjustable at any level, having arrangement to fit the automatic timer to work on 220/230 volts A.C. only with cord and plug.Double walled inside Aluminum/Stainless Steel 304 qty.Steel stand should be provided along with tyres on which instrument has to kept .Good stoving enamel with adjustable wire mesh nichol plated traysTraceability calibration certificate of controller should be provided Instrument should be calibrated from NABL calibration laboratory.Includes AMC for 5 years
AC (2 TON) Make DAIKIN Mitsubishi plugged fitting with stabilizer
RAJAN SCIENTIFIC TRADERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .