Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.3 LAccepted-AOC P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹45.9 L+₹2.0 L (4.50%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L2 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 3 | Rejected-Technical P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | - | Rejected-Technical REJECT DUE TO NOT ENLISTED IN PROPER CATEGORY IE BII | |
| 4 | Rejected-Technical A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | - | Rejected-Technical REJECT DUE TO NOT ENLISTED IN PROPER CATEGORY IE B II AND GST SUSPENDED AND ESIC NOT SUBMITTED |
| Sl No | Description | Qty | Unit | STANDARD ELECTRIC WINDERS L2 | Shree Trilok Electric Corporation L1 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation/cable trench, not exceeding 10Sqm on plan and getting out in soft/loose soil complete all as specified and as directed. | 563 | Cum | 370 ₹2,08,310 Lowest | 415 ₹2,33,645 |
| 2.00 | Returning filling including spreading, levelling and well ramming in layers not exceeding 25cm thick in soil complete all as specified and as directed. | 288 | Cum | 185 ₹53,280 | 170 ₹48,960 Lowest |
| 3.00 | Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. | 275 | Cum | 375 ₹1,03,125 | 350 ₹96,250 Lowest |
| 4.00 | M&L for sand cushioning with dry clean sand 15cm below cable and 8 cm above the cable complete all as specified and as directed.
Note : Punned thickness shall be measured for payments. | 225 | Cum | 2,200 ₹4,95,000 | 1,900 ₹4,27,500 Lowest |
| 5.00 | Supplying and laying un-reinforced precast concrete cable cover, classClass LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and directed. | 12,000 | Each | 41 ₹4,92,000 | 35 ₹4,20,000 Lowest |
| 6.00 | S&F sub class B brick, well burnt, laid breadth-wise along the axis of cable ;iad in trenches over sand cushion for cable protection complete all as specified and as directed. | 6,500 | Each | 18 ₹1,17,000 | 15 ₹97,500 Lowest |
| 7.00 | S&F in repair 50mm bore tubing “light grade” in trenches/ on pole for protection of cables complete all as specified & directed by Engineer-in-charge. | 18 | RM | 700 ₹12,600 | 670 ₹12,060 Lowest |
| 8.00 | Description all as per Ser item No.7 here-in-before but 40 mm bore | 36 | RM | 525 ₹18,900 Lowest | 550 ₹19,800 |
| 9.00 | Description all as per Ser item No.7 here-in-before but 80 mm bore | 18 | RM | 875 ₹15,750 | 850 ₹15,300 Lowest |
| 10.00 | Supply ,laying & testing in trenches / pole cable XLPE insulated screened PVC bedded galvanised steel strip or wire, armoured electric power cable (heavy duty) with stranded aluminium conductor 11000 volts earthed grade of cross sectioal area 120 sq mm 3.5 core with all fitting accessories etc. all as specified and directed. | 550 | RM | 1,050 ₹5,77,500 | 1,025 ₹5,63,750 Lowest |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
13 Oct 2025, 6:00 pmClosed
CWE DINJAN
COMMANDER WORKS ENGINEER DINJAN
CONVERSION OF LT ACSR CONDUCTOR LINES INTO LT XLPE UG CABLE REPLACEMENT OF OLD RUSTED FEEDR PILLAR BOES AND ASSOCIATED WKS AT MES GE OFFICE AND SURROUNDING AREA AT DINJAN MIL STN UNDER GE DINJAN
2025_MES_731098_1
84506/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE DINJAN
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹500
GE DINJAN
₹79,000
Yes
3 Jan 2026
16 Sept 2025
20 Oct 2025
16 Sept 2025
13 Oct 2025
30 Sept 2025
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation/cable trench, not exceeding 10Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading, levelling and well ramming in layers not exceeding 25cm thick in soil complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for sand cushioning with dry clean sand 15cm below cable and 8 cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
Supplying and laying un-reinforced precast concrete cable cover, classClass LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and directed.
S&F sub class B brick, well burnt, laid breadth-wise along the axis of cable ;iad in trenches over sand cushion for cable protection complete all as specified and as directed.
S&F in repair 50mm bore tubing “light grade” in trenches/ on pole for protection of cables complete all as specified & directed by Engineer-in-charge.
Description all as per Ser item No.7 here-in-before but 40 mm bore
Description all as per Ser item No.7 here-in-before but 80 mm bore
Supply ,laying & testing in trenches / pole cable XLPE insulated screened PVC bedded galvanised steel strip or wire, armoured electric power cable (heavy duty) with stranded aluminium conductor 11000 volts earthed grade of cross sectioal area 120 sq mm 3.5 core with all fitting accessories etc. all as specified and directed.
Descriptin all as per Ser item No. 10 here-in-before but 70 sq mm 3.5 core
Descriptin all as per Ser item No. 10 here-in-before but 35 sqmm 3.5 core
Descriptin all as per Ser item No. 10 here-in-before but 25 sqmm 3.5 core
Descriptin all as per Ser item No. 10 here-in-before but 16 sq mm 4 core
Descriptin all as per Ser item No. 10 here-in-before but 10 sqmm 4 core
Descriptin all as per Ser item No. 10 here-in-before but 25 sqmm 2 core
Descriptin all as per Ser item No. 10 here-in-before but 16 sqmm 2 core
Descriptin all as per Ser item No. 10 here-in-before but 10 sq mm 2 core
Dismantling of old/rusted aluminium conductor steel reinforced of any size and removing the same from site of work all as specified and directed.
Dismantling of old/rusted Cross arms,bracings, supports, clamps and back plates including nut bots etc any size and removing the same from site of work all as specified and directed.
Dismantling insulators any type, any size all as specified and directed.
Supply, install, testing and commissioning outdoor type LT panel of minimum size 1m x 1m x 0.6m, with IP65 factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement with magnetic door closing system, neoprene gasket and gland packing at cable entry/exit point and both front and rear door painted with powder coated paint and aluminium bus bar of 400 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items :- Note : Foundation & 75 mm thick PCC hardstanding surrounding the LT panel upto 1.5 mtrs to be included in the quoted price Incoming :- (a) MCCB, 4 Pole, 250A, 415 V, 36 kA. (I/C).Thermal magnetic adjustable type (b) multifunction 3 phase meter duly showing voltage,amps,kw,PF,frequency,kva & kVar. (c) Internal connection by aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc Outgoing :- (a) MCCB, 4 Pole, 100 Amp, 415 V, 36 kA - 01 No Thermal magnetic adjustable type (b) MCB, TPN, 63 A, 240 V, 18 kA - 01 No. (c) MCB, TPN, 32 A, 240 V, 18 kA - 05 No.
M&L for horizantal boring/drilling hole mannual under the road in soft/loose soil without cutting/disturbing the existing road and inserting GI pipe 80/50/40/32mm bore for drawing the cables complete all as specified and directed. (Note: (i) Cost of acessories required for making hole/bore deemed to be included in the quoted rate. (ii) GI pipe has been measured and paid separately)
S&F RCC cable route indicator with embrossing mark as LT cable, of size 75 cm x 15cm x 7.5cm along with foundation size 75 cm x 30 cm x30 cm and duly painted with colour coding as approved by GE.
Supply, install, testing and commissioning outdoor type LT panel minimum size 1m x 1m x 0.6m, with IP65 factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement with magnetic door closing system, neoprene gasket and gland packing at cable entry/exit point and both front and rear door painted with powder coated paint and aluminium bus bar of 300 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items :- (FP-II) Note : Foundation & 75 mm thick PCC hardstanding surrounding the LT panel upto 1.5 mtrs to be included in the quoted price Incoming :- (a) MCCB, 4 Pole, 160 A, 415 V, 25 kA. (I/C). Thermal magnetic adjustable type (b) multifunction 3 phase meter duly showing voltage,amps,kw,PF,frequency,kva & kVar. (c) aluminium bus bar 4 strip - 300 amps (d) Internal connection by aluminium strip from MCB/MCCB to busbar and busbar to MCCB/MCB etc Outgoing :- (a) MCCB, 4 Pole, 100 A, 415 V 25 kA - 01 nosThermal magnetic adjustable type (b) MCB, TPN, 32 A, 240 V, 18 kA - 05 No. (c) MCB,TPN, 63A, 240 V, 18 kA - 01 Nos.
Supply, install, testing and commissioning outdoor type LT panel of minimum size 1m x 1m x 0.6m, with IP65 factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement with magnetic door closing system, neoprene gasket and gland packing at cable entry/exit point and both front and rear door painted with powder coated paint and aluminium bus bar of 400 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (FP - IV). Note : Foundation & 75 mm thick PCC hardstanding surrounding the LT panel upto 1.5 mtrs to be included in the quoted price Incoming :- (a) MCCB, 4 Pole, 250 A, 415 V, 36 kA. (I/C).Thermal magnetic adjustable type (b) multifunction 3 phase meter duly showing voltage,amps,kw,PF,frequency,kva & kVar. (c) Internal connection by aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc. Outgoing :- (a) MCCB, 4 Pole, 100 Amp, 415 V, 36 kA - 01 No Thermal magnetic adjustable type (b) MCB,TPN, 63A, 240 V, 18 kA - 01 Nos. (c) MCB, TPN, 32 A, 240 V, 18 kA - 05 No.
Supply, install, testing and commissioning outdoor type LT panel of minimum size 1m x 1m x 0.5m, with IP65 factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement with magnetic door closing system, neoprene gasket and gland packing at cable entry/exit point and both front and rear door painted with powder coated paint and aluminium bus bar of 300 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (FP-III) Note : Foundation & 75 mm thick PCC hardstanding surrounding the LT panel upto 1.5 mtrs to be included in the quoted price Incoming :- (a) MCCB, 4 Pole, 160A, 415 V, 25 kA. (I/C). Thermal magnetic adjustable type (b) multifunction 3 phase meter duly showing voltage,amps,kw,PF,frequency,kva & kVar. (c) aluminium bus bar 4 strip - 300 amps (d) Internal connection by aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc Outgoing :- (a) MCCB, 4 Pole, 100 Amp, 415 V, 36 kA - 01 No Thermal magnetic adjustable type (b) MCB,TPN, 63A, 240 V, 18 kA - 01 Nos. (c) MCB, TPN, 32 A, 240 V, 18 kA - 04 No.
Materials and labour for PCC ( 1:4:8) type D-2 Using 40 mm graded stone aggregate as in foundation of stay assembly , poles struts etc. complete all as specified and as directed .
Dismantling of GI Earth wire 40mm or any size all as specified and directed.
M&L Earthing complete with Galvanised steel earth plate 60cmx60cmx6mm thick electrode, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 m below ground level , connected to GI earth strip 25 X 4mm up to test point by means of bolts ,nuts , check nuts and washers of GI including excavation and earth work, PCC 1:3:6 type C-1 pit, 20mm dia GI pipe medium grade, watering pipe and 20 mm bore GI pipe, light grade for protection of earth strip, MS angle iron frame 40x40x3mm, 10mm thick RCC 1:2:4 type B-1 cover reinforced with 6mm dia MS bars @ 75mm C/C both ways and with MS handle made out of 12mm dia bars, PGI Funnel, wire mesh etc complete all as shown in electrical Plate No 03 of SSR Part-I and connected to earthing test point all as specified and directed.
S&F new PVC cable Junction Box IP66 "halogen free and weather proof" for out door installation size not less than 200 x 150 x 100 mm suitable for street light incoming and outgoing cables up to 10 to 25 sqmm 4 core (with terminal) & inclusive of MCB SP 10 Amp, 60A 04 strip aluminium Bus Bar, including nuts, bolts, cable glands & MS clamps fixed to pole all as specified and directed.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire unarmoured, electric control cables with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade passed throuh PVC conduit medium grade of size Min 20 mm complete all as specified and directed.
Supply, install, testing and commissioning outdoor type LT panel of size .6m x 0.6m x 0.5m , with latest IP factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door painted with powder coated paint and aluminium bus bar 200 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (Bus Bar Panel). Note : Foundation to be included in the quoted price (a) aluminium bus bar 4 strip of 200 Amps having hole drilled on Bus Bar for fixing of cables all as specified and directed.
Supply & fix for cable straight through joint for 1100 volt, out door type terminal heat shrinkable type joint complete with all jointing material and accessories suitable for 3.5/4 core 70-150sqmm, complete all as specified and directed.
Supply & fix for cable straight through joint for 1100 volt, out door type terminal heat shrinkable type joint complete with all jointing material and accessories suitable for 2/3.5/4 core 25-50sqmm, complete all as specified and directed.
Supply & fix for cable straight through joint for 1100 volt, out door type terminal heat shrinkable type joint complete with all jointing material and accessories suitable for 2 core 10-25sqmm, complete all as specified and directed.
Material and Labour in repair, dismantling the all cable from panel, poles, MCB Main DBs taking out the cable loop stretching out the cable, carrying out end termination with new lugs, proper thimbling, fixing the joint kits connecting back to the new/existing panel board by means of nuts, bolts & washers of any size any type all as specified and directed. Note : (The work includes necessary excavation to take out the loop,and laying the cable, putting proper cable protection bricks using the old retrived bricks and refill the area properly and spreading any surplus soil (ii) The cost of Al lugs, joint kit shall be measured and paid separately under relevant items of schedule
STANDARD ELECTRIC WINDERS (BID ID -3448990)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .