| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.2 LAccepted-AOC 4 KHEME KA KUA PAL ROAD JODHPUR RAJASTHAN 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹31.8 L+₹10,415 (0.33%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹35.2 L+₹3.5 L (11.0%)Rejected-Finance 602 TECHNOLOGY APARTMENTS 24 1 P EXTENSION DELHI 110092 | DELHI | DELHI | DELHI | 110092 | L3 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
18 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Improvement to RSO tower, operational bldg and misc tech stores for AF equipment at Chandan AF Stn Jaisalmer
2021_MES_469676_1
8762/GE/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹78,000
Yes
24 Sept 2021
21 Aug 2021
20 Sept 2021
21 Aug 2021
18 Sept 2021
6 Sept 2021
23 Aug 2021 - 27 Aug 2021
60 days
Amount
Taking down chowkhats or frame with shutters (without taking off shutters from the frames), area not exceeding 1.5 Sqm each complete all as specified.
Taking down chowkhats or frame with shutters (without taking off shutters from the frames), area exceeding 1.50sqm but not exceeding 4.00sqm each complete all as specified and directed.
Taking down shutters any description area exceeding 1.00 sqm each but not exceeding 2.00 sqm each complete all as specified and directed.
Solid PVC fire resistant wall panelling/ Lining consisting of 5mm thick prelaminated PVC sheet inclusive of solvent cement and fixing at site on PVC frame etc., including taking down of existing wall panelling with frame and E/M fitting/Fixtures complete all as specified and directed. Note:- Rates shall be inclusive of refixing of taking down of E/M fittings and fixtures.
5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall with screws to make PVC frame as per specification complete all as specified and directed.
10mm thick plaster in cement and sand mortar (1:6) on stone masonary surface on other than fair face of brick work or concrete surfaces or stone masonry of wall, finished even and smooth without using extra cement with wall care putty and including taking down old cement plaster complete all as specified and directed.
5mm thick ceiling plaster in cement and sand mortar (1:3) on uneven faces of concrete surfaces on fair of ceiling and finished even and smooth without using extra cement with wall care putty including taking down old cement plaster complete all as specified and directed.
15mm thick plaster in cement and mortar (1:4) on stone masonary surface on other than fair face of brick work or concrete surfaces or stone masonry of wall, including taking down old cement plaster complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Removal of excavated soil/ material to a distance exceeding 250 metre but not exceeding 500 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed.
Demolition of plain cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
Precast cement concrete (1:3:6), type C-1 (using 20mm graded stone aggregate) as solid block masonary exceeding 10cm and set in cement and sand mortar (1:6) complete all as specified and directed.
Mortice lock brass, vertical type, size 100mm 4 lever complete all as specified and directed.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in door, overall length of cover plate 140mm fixed complete all as specified and directed.
Aluminium extruded section body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851-1000mm in width & weight between 61 to 80 Kg, complete all as specified and directed.
Anodised aluminium frame & shutter for door, window, ventilator with one or more rebates including necessary joining cleats, glazing clips, rubber neoprene packing for fixing, anodised aluminium snap beading, screws etc. with powder coating (Minimum thickness of powder coating 50 micron) complete all as specified and directed.
Anodised aluminium door shutters of section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handle 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc with powder coating (Minimum thickness of powder coating 50 micron) complete all as specified and directed.
Anodized aluminium sections as in window and ventilator shutters, side hung type without sash bars (aluminium sections weighing 0.55 kg/m) including necessary jointing cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (01 Nos each shutter), extruded anodised aluminium alloy with galvanised mild steel hinge pin, 100mm long (03 Nos each shutter), extruded anodised handle of suitable type (01 No. each shutter) etc. with powder coating (Minimum thickness of powder coating 50 micron) complete all as specified and directed.
Anodized aluminium snap grid frame work for false ceiling as per manufacturer's instructions with hangers from RCC soffit/steel trusses with 6mm dia GI rod (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long with including exposed metal frame ceiling with calcium silicate 8mm thick board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid including taking down/dismentling of false ceiling boards of any discription size or thickness frame work etc complete all as specified and directed.
Machine cut kota stone slab flooring, 20-25mm thick laid in floors in squares or rectangular pattern laid over 15mm thick cement screed bed in cement and mortar (1:6) set and jointed in neat cement slurry and pointed coloured cement to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Machine cut Kota stone slab 20 to 25mm thick, as in skirting, riser of step, dado and pillar etc. laid over and including rendering of 10mm thick in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
20mm thick black granite slab/ tiles in floors/treads etc, set & jointed with neat cement slurry over and including 15mm thick screed bed in cement mortar (1:6) and pointed with white cement with admixture of pigment to match with shade of Granite stone including cutting, grinding and polishing (mirror polish i.e. full granite polish as per local trade practice) complete all as specified and as directed.
20mm thick black granite (of any type) work as in wall lining (veneering to wall) and skirting and risers over & including 15mm thick screed bed (bedding layer) in cement mortar 1:4, jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with shade of granite stone including cutting and polishing (mirror polish i.e. full granite polish as per local trade practice) all as specified & directed.
Extra over stone slabs for rounding to edges such as in steps, platform and other similiar situation complete all as specified and directed.
Hardcore of guage not exceeding 63mm deposited spread and leveled in layers not exceeding 15cm thick watered and rammed to a true surface complete all as specified and directed.
100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base of flooring finishing cement concrete surface fair and even complete all as specified and directed.
Plain cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in lintels upto 1.50m clear span, cill, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets, railing, copings and like including weathering slightly rounded or chamfered angles and throating, necessary formwork as required etc complete all as specified.
Coloured glazed ceramic tiles as in dado/skirting 450x350x7mm or 350x250x7mm thick on vertical surfaces, over and including 10mm thick cement and sand mortar (1:4) backing coat set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tile and including dismantling floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed
Coloured Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc over 15mm thick in cement and mortar (1:6) bedding set and jointed in neat cement slurry and pointed in coloured cement to match and including dismantling floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed
Double charged Vitrified ceramic tiles 10mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm, as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15mm thick screed bed in cement and sand mortar 1:6 and including dismantling floor, hearth or wall tiling including cement mortar bedding complete all as specified
Double charged Vitrified ceramic tiles 10mm thick (square/rectangular), polished, coloured (light shade as approved) on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick screed bed in cement & sand mortar 1:4 and including dismantling floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed
Machine pressed factory made rubber moulded precast concrete interlocking paver block any shape and size conforming to IS-15658-2006 of 60mm thickness, M-35 grade with grey cement with pigment and including 25mm thick machanicaly compacted thickness of sand bedding below pavor tiles laid to required level & slope complete all as specified and directed.
Preparation of newly plastered surfaces or unplastered surfase of walls and applying two coats of oil emulsion distemper complete all as specified and directed.
Preparation of newly plastered or unplastered of wall surfaces and applying two coats of cement base paint of approved tint complete all as specified and directed.
Preparation of newly plastered surfaces or unplastered surfase of ceiling and applying two coats of distemper oil emulsion complete all as specified and directed.
Preparation of old plastered surfaces of walls and applying one coat of oil emulsion distemper complete all as specified and directed.
Preparation old plastered surfaces of ceiling and applying one coat of distemper oil emulsion complete all as specified and directed.
Complete removal of existing treatment of plastered surfaces or unplastered surfaces of walls and applying two coats of Acrylic Smooth exterior paint (applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
3mm thick sheet glass ordinary quality and glazing with oil putty not exceeding 0.50 sqm in each pane and fixing new panes any building height including Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones, complete all as specified and directed.
8mm thick Toughned glass as in hinged doors, metal frame, partitions automatic doors and similar work including cutting to shape, drilling holes required, including taking down old glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
Supply only 4.80mm thick sheet glass ordinary quality not exceeding 0.50 sqm in each pane complete all as specified and directed.
Solar control film 25 micron reflactive type approved colour sticked to glass panes as per instructions of manufacturers complete all as specified and directed.
Prepariation of old steel surfaces of any description, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Prepariation of newly or previously untreated steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of newly surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified and directed.
75mm thick Plain Cement Concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection and flooring complete all as specified and directed.
Aluminium anodised tubular towel rail of 25mm dia including two Nos of brackets in each rail length fixed as in repair complete all as specified and directed.
Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and including dismantling of asbestos cement, plain or corrugated steel/fiber sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings including taking down old unserviceable complete all as specified and directed.
Mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc. conforming to Grade E-165 (Fe 290) complete all as specified and directed.
Mild steel rolled sections as in stairs framed including stringers, treades, landing, balusters, hand rails, including cleats, brackets etc. conforming to Grade E-165 (Fe 290) complete all as specified and directed.
Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Gde E-165 (Fe-290) complete all as specified and directed.
Prelaminated particle board 18/19mm thick interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, wall or stone fixed as in repair complete all as specified & as directed.
12mm thick plywood, grade BWR, type BB, fixed with screws, nut, bolts to timer or metal frame work, frequency of fixing of plywood as per operational requirement fixed as in repair complete all as specified and directed.
2nd class Hard Wood of 40mm thick for boarding in floors, skirting, staging, treads & risers of steel stairs and similar works, planed one side, with butt joints and fixed with nails, nut & bolts and fixed as in repairs complete all as specified and directed.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
Stainless steel (Grade-304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
Steel rolling shutters of 1.00mm thick laths, with out ball bearing, as specified including top cover, side guides, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, complete, gear operated type with bevel gear box and crank handle complete all as specified and directed.
Point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non metalic rigid PVC conduit 20mm dia with accessories fixed to cutting chases in walls by cutter and making good the surface in cement and sand mortar 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surfaces conduit with clamps, gutties etc for RCC ceiling with including cast iron/pressed steel/wooden terminal boxes (as per site requirement) including including providing new 3 mm thick plastic laminated sheet cover (Hylem) including taking down old unserviceable point wiring complete all as specified & directed.
All as per serial item No. 61.00 here-in-before but for one fan point controlled by one switch and regulator complete all as specified and directed.
All as per serial item No. 61.00 here-in-before but for one 3 Pin, 6 Amps, socket outlet controlled by one 6 Amps switch on same board complete all as specified and directed.
All as per serial item No. 61.00 here-in-before but for one 3 Pin, 6 Amps, socket outlet controlled by one 6 Amps switch on independent board complete all as specified and directed.
All as per serial item No. 61.00 here-in-before but for One 3 pin 6 amps socket outlet independent but below the switch board of light points in the same vertical plane complete all as specified and directed.
Point wiring for one 6 pin, 16 Amps socket outlet controlled by one 16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non metalic rigid PVC conduit 20mm dia with accessories fixed to cutting chases in walls by cutter and making good the surface in cement and sand mortar 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surfaces conduit with clamps, gutties etc for RCC ceiling with including cast iron/pressed steel/wooden terminal boxes (as per site requirement) including including providing new 3 mm thick plastic laminated sheet cover (Hylem) complete all as specified and directed.
Point wiring for one light point controlled by one way switch with 1.50 sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade including 1.50 sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated & including suitable size module boxes for housing of modular switches, sockets, regulators including taking down old unserviceable point wiring complete all as specified & directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/Anchor/Formica including machine screws and washer etc for fixing switches sockets etc including 1.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed.
All as per serial item No. 67.00 here-in-before but for one fan point controlled by one switch and regulator complete all as specified and directed.
All as per serial item No. 67.00 here-in-before but for one light point controlled by two way switch complete all as specified and directed.
All as per serial item No. 67.00 here-in-before but for one 3 pin 6 Amp socket outlet controlled by one 5/6 Amp switch on same board complete all as specified and directed.
All as per serial item No. 67.00 here-in-before but for one 3 pin 6 Amp socket outlet controlled by one 5/6 Amp switch on independent board complete all as specified and directed.
All as per serial item No. 67.00 here-in-before but for One 3 pin 6 amps socket outlet independent but below the switch board of light points in the same vertical plane complete all as specified and directed.
Point wiring for one 3 Pin, 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated & including suitable size module boxes for housing of modular switches, sockets, regulators including taking down old unserviceable point wiring complete all as specified and directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/Anchor/Formica including machine screws and washer etc for fixing switches sockets etc including 1.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed.
Switch piano, flush type, Single Pole, one way, 6 Amp, 240 Volts (ISI Marked) fixed as in repair complete all as specified and directed.
Switch piano, flush type, Single Pole, one way, 16 Amp, 240 Volts (ISI Marked) fixed as in repair complete all as specified and directed.
Switch piano, flush type, Single Pole, two way, 6 Amp, 240 volt (ISI Marked) fixed as in repair complete all as specified and directed.
Socket outlet 2 in 1, 5 pin, 16 Amps, flush type, 240 Volts (ISI Marked) fixed as in repair complete all as specified and directed.
Socket outlet, 2 in 1, 3 pin, 6 Amp, flush type, 240 Volts (ISI Marked) fixed as in repair complete all as specified and directed.
Modular switch 6 Amps, 250 Volt, AC, one way, one module (ISI Marked) fixed as in repair complete all as specified and directed.
Modular switch 20 Amps, 250 Volt, Single Pole, AC, one way with indicator one module (ISI Marked) fixed as in repair complete all as specified and directed.
Modular Socket shuttered, 6 Amps, 250 volts, 2/3 Pin combined, Single Pole, universal India two module (ISI Marked) fixed as in repair complete all as specified and directed.
Modular Socket shuttered, 6/16 Amps, 250 volts, 3 Pin combined, Single Pole, two module (ISI Marked) fixed as in repair complete all as specified and directed.
Modular Fan Regulator, step type, 120 Watt, 2 module, 250 volts grade, (ISI Marked) fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 1/2 Module fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 3 Module fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 4 Module fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 6 Module fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 8 Module fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 12/16 Module fixed as in repair complete all as specified and directed.
White colour modular blanking plate, one module blank fixed as in repair complete all as specified and directed.
White colour plates with frame for modular switch of 1 module fixed as in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 2 module fixed as in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 3 module fixed as in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 4 module fixed as in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 6 module fixed as in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 8 module fixed as in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 2 x 6 module fixed as in repair complete all as specified and as directed.
Ceiling rose surface bakelite with two or three terminal PVC/Polycarbonate, isolated body (ISI Marked), 240 volts fixed as in repair complete all as specified and directed.
Stepped type electronic fan regulator, flush type and connecting up, 120 watt, 240 volt (ISI marked) fixed as in repair complete all as specified and directed.
MCB Protected Socket (Modular AC Box, Metal clad box) Two Module, Single Pole, 20 Amps, repturing capacity 10 kA and neutral enclosure in sheet steel with a two pin and earth plug and socket including taking down old unserviceable complete all as specified and directed.
Surface and wall mounted 10 watt LED bulk head fitting in engineering plastic housing with clear prismatic diffuser complete with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 including taking down old unserviceble LED fittings complete all as specified and directed.
Decorative ultra slim round profile LED tube light fittings of capacity 9 watt LED 6000 K, basic all purpose surface and wall mounted LED batten with extruded polycarbonate housing & integrated electronic driver including taking down old unserviceble LED fittings complete all as specified and directed.
Decorative ultra slim square profile LED tube light fittings of capacity 18 watt LED 6500 K, basic all purpose surface and wall mounted LED batten with extruded polycarbonate housing & integrated electronic driver including taking down old unserviceble LED fittings complete all as specified and directed.
Decorative ultra slim square profile LED tube light fittings of capacity 20 watt LED 6500 K, basic all purpose surface and wall mounted LED batten with extruded polycarbonate housing & integrated electronic driver including taking down old unserviceble LED fittings complete all as specified and directed.
LED Panel 36 watt with 2ft x 2 ft slim panel 595X595mm with super bright recess mounting LED Slim ceiling light with white powder coated extruded aluminium housing and highly efficient light smoothing optics to deliver superior illumination including LED driver and fixing in recess ceiling suitable size of aluminium strip size as required for fixing of LED fitting complete with all accessories prewired fixed on ceiling and connecting up complete with 3 core flexible cable of size 23/0.0076 including taking down old unserviceable fittings complete all as specified and directed.
Sub main wiring with 4.00 sqmm, Single Core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 volts grade conforming to IS 694 including 4.00 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit including taking down old unserviceable submain wiring complete all as specified. Note : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
Sub main wiring with 6.00 sqmm, Single Core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 volts grade conforming to IS 694 including 6.00 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit including taking down old unserviceable submain wiring complete all as specified. Note : Two run of 6.00 sqmm cable and one run of 6.00 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
MCB, Single Pole, 6 to 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles complete, all as specified & directed.
MCB, SPN, 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles complete, all as specified & directed.
MCB, SPN, 40 to 63 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete, all as specified & directed.
MCB, TPN, 40 to 100 Amps rating, with over load and short circuit protection 'B' curve and rupturing capacity 10 kA, 415 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete all as specified & directed.
MCCB, 4 Pole, 100 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC supply, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
Sheet metal enclosure powder coated single phase DB SPN 8 ways and neutral 240 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Single Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable DB complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB SPN 12 ways and neutral 240 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Single Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable DB complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB TPN 4 ways and neutral 415 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable DB complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB VTPN 4 ways and neutral 415 Volts, AC, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable complete all as specified and directed.
Supply, installation, window type Air conditioning, electric driven single phase of capacity 1.50 TR (5 Star EER), cooling capacity 6000 K Cal per hour complete with cordless remote control and with in built air ioniser and plasma filter for better indoor air quality and connecting up all as per manufacturer’s instructions complete all as specified and directed. Note:- Cost of cutting chases/cutting holes etc in walls/floors including making good in cement mortar 1:4 and other necessary arrangement for fixing window AC & other minor extras shall be deemed to be included in quoted rate of this item.
Supply, installation, voltage stabilizer for automatic operation single phase naturally air cooled indoor type copper wound and designed for input variation between 170 volts to 250 volts with output voltage stabilized at 230 volts with accuracy of ± 2.5% of capacity 5 KVA with mounting bracket with time delay relay complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No. 3 of SSR Part-I and connection to main switch board/Test point/ panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exceeding 50 metre, charcoal and salt in alternate layer 15cm thick all around the earth plate electrode, Mild Steel Funnel with wire mesh, 20mm bore, GI pipe medium grade, 1.50 metre long for watering and 15mm bore, GI pipe light grade, 7.50 metre long for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:2:4) type B-1, using 20mm graded stone aggregate with angle iron 40x40x5mm frame 60mm thick RCC cover with 6mm steel bars 100mm centre to centre both ways etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : (i) PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) If earth resistance of earthing is not found satisfactory it will be redone by the contractor on his risk and cost.
Dismantling, taking down of old unserviceable Package type Air Conditioning Plant after electrically disconnected including ducts made out of GI sheets of any size and depositing to MES yard complete all as specified and directed.
Supply, installation, testing and commissioning of conventional optical smoke detectors with an optical measurement method for earliest fire detection and indication and type certified complete with standard base for conventional detector including taking down old unserviceable complete all as specified and directed.
Supply, installation, testing and commissioning of zonal indicator panel of upto 2 zone conventional fire alarm control panel with features such as non latching zones, false alarm management, EN 54-2, EN 54-4 LPCB approved including taking down old unserviceable complete all as specified and directed.
Supply, installation and connecting conventional type manual call point resettable, typically installed at various fire escape route locations throughout a premises including taking down old unserviceable complete all as specified and directed.
Supply, installation, connecting and testing conventional wall sounder including taking down old unserviceable complete all as specified and directed.
Remote response indicators including taking down old unserviceable complete all as specified and directed.
Sub main wiring, Single core, 2x1.5 Sqmm PVC insulated and unsheathed multi stranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 volts grade conforming to IS 694 including 1x1.50 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit including taking down old unserviceable submain wiring complete all as specified and directed. Note : Two run of 1.50 sqmm cable and one run of 1.50 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
Sub main wiring, single core, 2x2.5 Sqmm PVC insulated and unsheathed multi stranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 volts grade conforming to IS 694 including 1x1.50 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit including taking down old unserviceable submain wiring complete all as specified and directed. Note : Two run of 2.50 sqmm cable and one run of 2.50 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
M/s Fateh Enterprises
M/s Ramesh & Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .