Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹95.8 LAccepted-Finance C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | ₹95.8 L | L-1 | Accepted-Finance responsive. |
| 2 | L-2₹1.0 Cr+₹8.5 L (8.83%)Accepted-Finance | ₹1.0 Cr+₹8.5 L (8.83%) | L-2 | Accepted-Finance responsive. |
| 3 | L-3₹1.3 Cr+₹31.3 L (32.6%)Accepted-Finance | ₹1.3 Cr+₹31.3 L (32.6%) | L-3 | Accepted-Finance responsive. |
| 4 | L-4₹1.5 Cr+₹51.6 L (53.9%)Accepted-Finance | ₹1.5 Cr+₹51.6 L (53.9%) | L-4 | Accepted-Finance responsive. |
Tender Value
₹1 Cr
EMD Value
₹1.8 L
Closing Date
8 Apr 2025, 2:05 pmClosed
Chief Executive Officer
Delhi Cantonment Board, Sadar Bazar Road, Delhi Cantt-110010
Term Contract for erection of steel tubular poles, octagonal poles and high mast lights and light fittings in Delhi Cantt
2025_DGDE_701695_1
DCB/8/EandM/C-21/2024-25
Open Tender
Electrical and Maintenance Works
Percentage
Delhi Cantonment Board
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Chief Executive Officer, Delhi Cantonment Board
₹1.8 L
5 May 2025
18 Mar 2025
9 Apr 2025
18 Mar 2025
8 Apr 2025
18 Mar 2025
Amount
Schedule 'A'
Supplying transporting to site and fixing of steel tubulor poles swaged type in three sections as specified Type 410, SP 25 9 metre long with single arm bracket made out of MS pipe of outer dia 60.3 mm and wall thickness 2.90 mm with 50 mm diaNippal suitable to fix light fittings, along with MS plate of size 34 CM x34 CM x6 mm thick welded at the bottom of pipe including painting of poles with two coat of aluminum paint over a coat of red oxide zinc chrome primer on exposed surfaces and black bituminous point on steel surface embedded in concrete and painting black and yellow paint strips up to 1.5m from plinth block and numbering of poles with 75 mm (3”) high letters and figure at height of 2400mm (8’) from the ground level in white paint over black paint conforming to IS: 2713 ( Part-II)-1980as specified and directed by Engineer –in-Charge.
Supplying transporting to site and fixing of steel tubulor poles swaged type in three sections as specified Type 410,SP-4 7.50 Mt. long with single arm bracket made out of MS pipe of outer dia 60.3 mm and wall thickness 2.90 mm with 50 mm diaNippal suitable to fix light fittings, along with MS plate of size 34 CM x34 CM x6 mm thick welded at the bottom of pipe including painting of poles with two coat of aluminum paint over a coat of red oxide zinc chrome primer on exposed surfaces and black bituminous point on steel surface embedded in concrete and painting black and yellow paint strips up to 1.5m from plinth block and numbering of poles with 75 mm (3”) high letters and figure at height of 2400 mm (8’) from the ground level in white paint over black paint conforming to IS: 2713 ( Part-II)-1980as specified and directed by Engineer –in-Charge.
M/L supply and erecting of octagonal poles of 7.0metre height with 150 mm bottom Dia75 mm at top made out of 3mm thick MS sheet along with galvanized base plate of size 225x225x16 mm suitable to with stand Maximum. Wind speed 169 KM/Hr and suitable for mounting double or single arm bracket with street light fitting . The internal and external surfaces of the pole shall be hot dip galvanized to 65 microns DFT. The pole will have a weather proof comonflaged junction box at about 5 mm height with flush cover for cable termination block and earth stud with nuts washers etc including provision of drawing cable size upto 2 no, 2 core , 16 sqmm including supply 4 nos 20x750 mm long J type EN8 grade foundation bolts with nuts and washers and 63 amps terminal block suitable for 2 core 16 sqmm conductor cable termination and including providing GI pipe medium grade bracket of suitable length and size as directed for fixing of light fitting. The pole should be complete in all respect with all accessories required including painting of poles as directed by Engineer-in- Charge.
S/F , laying jointing of two run of PVC insulated cable 2.5. sq mm size with copper conductor and connecting from kiosk box to light fittings and main Board to fittings all as specified and directed by Engineer in-Charge.
Providing and casting in position M-30 grade reinforced cement concrete pole foundation of size 550 mm x550mm x1500mm including providing cutting , bending and placing in position reinforcement of 8 nos. cold twisted , vertical bars of 12 mm dia and reinforcement of cold twisted bars of 8 mm dia with 190 mm spacing and fixing of J bolts , terminal blocks MCB etc including providing and placing 63 mm internal dia. DWC pipe double wall corrugated with corrugation on outer face and plain surface on minor side, HDPE pipe of suitable bore of suitable length for cable inlet and exit as specified and directed by Engineer-in- Charge.
S/F kiosk box weather proof made out of Engineering plastic one piece moulding of size 30x20x10 cm including 30 amps aluminum bus bar(two strips) mounted on the bus-bar insulator of inflammable material MCB 6 Amp Current rating for controlling street light complete to be mounted on pole with suitable clamps made out of MS flat of 25x3 mm with nut bolts and washers including provisions of shutter to be opened/closed vertically locking arrangement complete including danger notice of size not less than 10cm x 7cm with letters, figures and conventional skull and bones in signal red colour on front face of kiosk box body all as specified rates directed by Engineer-in- Charge.
Supplying /installation/testing and commissioning feeder pillar outdoor, cubical type, weather proof totally enclosed suitable for 440 V , 3 phase,50 C/s electric supply fabricated out of angle, 40 mx40m x6mm and Ms plain sheet 2 mm thick complete with two coats of spray painting of enamel paint, with a prior coat of primer, comprising of the following: a) Aluminum bus bar TPN , 3 phase, 4 strips-100 Amp. 1set. b) Incoming MCB TPN 63 Amp -1 No. c) OutgoingMCB TPN 32Amps. – 1 No. d) MCB Single phase neutral (SPN) outgoing - 4 Nos. 32 Amps. e) 24 Hrs electronic Timer- 01 no. f) 40 Amp TP Air brake contactor -01 g) Heavy duty godown lock- 02 nos. h) Termination incoming /outgoing cable with suitable size of ferrules and compression gland. i) Hinged door open able on both side with heavy duty locking system-2 no. j) Canopy at Top. k) Legs of suitable length made out of 40 mmx40mmx6 mm angle iron including grouting the legs in 1:2:4 CC.
S/F Switch fuses iron clad or sheet metal SP fused single phase 32 Amp including making connections.
M/L MCB single pole and neutral with PVC enclosures 32 Amps including connection to operate the street light
Boring hole horizontally under ground at required level with trenchless digging machine or manually suitable to pass 50 mm dia MS pipe in the bored hole under the road including passing of cable of size 2x16 sqm and disposal of spoil to a distance n exc 125 m all as specified and directed by the Engineer in Charge (MS pipe and fitting measured and paid separately).
S.F and laying into horizontal bore hole under the road 50 mm dia MS pipe heavy duty 3.25 mm wall thickness, welded and socketed ends as specified and directed by Engineer in-Charge.
M/L painting of existing pole with two coat of aluminium paint by preparing the exposed surface suitable for receiving paint including painting black and yellow paint strip upto 1.5m from plinth block and writing of pole number for any time of pole as directed by Engineer-in-Charge
M/L painting of electric poles brackets of any length, any description with aluminum paint of three coats of good quality including preparing surface of the pole smooth to receive painting as specified and directed by Engineer-in-Charge.
S/F installation testing of feeder pillar outdoor cubical type, weather proof totally enclosed suitable for 440V, 3 phase, 50 HZ electric supply fabricated out of angle 40x40x6mm & MS plain sheet of 2mm thick complete with two coats of spray painting of enameled paint, with a prior coat of primer, comprising of the following for termination of cable connection from MES feeder pillar a) Aluminium bus bar TPN-300 Amp- 1 set b) Incoming MCCB 250 Amp-01 No. c) Out going MCCB 200 Amp- 01 No. d) Conopy at the top e) Legs of suitable length made out of 40mmx40mmx6mm angle iron and including grouting of lengs in CC 1:2:4 f) Cable gland as per cable size and number of cables
S/F of bracket made out of G.I. Pipe medium grade 50 mm dia to be mounted on the existing pole or the walls buildings alongwith suitable clamps with nut bolts washers complete all as specified & directed by Engineer-in-charge
S.I.T & C of continuously tapered multifaceted and polygonal cross section High Mast as per detailed specification and details given a) ½ section having suitable sectional length with slip joints between sections without any circumpherence welding. b) Double drum winch with separate handle operation for manual operation and motorised operation of winch with a torque limiting device for safe docking of carriage. c) Raising /lowering type lantern carriage designed to carry 6 nos luminaries; of 1 x 250 watts control gear box, junction box and top pulley assemble with weather proof cover. d) Necessary suitable length for lowering and rising of lantern carriage of stainless steel wire ropes of 7/19 construction with minimum 6mm dia) and multi core flexible copper power cable e) Hinged service door in base section base plate earthing terminal. f) Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast. g) Complete with other provision for execution in the confirmation with detailed technical specifications. h) Lightning conductor finial made of 25mm dia 300 mm long G.I. tube having single prong. i) Integral single power tool (electrical) for lowering and raising of high mast . j) Anchor plate, templates, foundation bolts manufactured from special steel along with nuts washers etc. 12.00 meter High mast (two sections)
S.I.T & C of continuously tapered multifaceted and polygonal cross section High Mast as per detailed specification and details given a) ½ section having suitable sectional length with slip joints between sections without any circumpherence welding. b) Double drum winch with separate handle operation for manual operation and motorised operation of winch with a torque limiting device for safe docking of carriage. c) Raising /lowering type lantern carriage designed to carry 6 nos luminaries; of 1 x 250 watts control gear box, junction box and top pulley assemble with weather proof cover. d) Necessary suitable length for lowering and rising of lantern carriage of stainless steel wire ropes of 7/19 construction with minimum 6mm dia) and multi core flexible copper power cable e) Hinged service door in base section base plate earthing terminal. f) Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast. g) Complete with other provision for execution in the confirmation with detailed technical specifications. h) Lightning conductor finial made of 25mm dia 300 mm long G.I. tube having single prong. i) Integral single power tool ( electrical) for lowering and raising of high mast . j) Anchor plate, templates, foundation bolts manufactured from special steel along with nuts washers etc. 16.00 meter High mast (two sections)
S.I.T. & C of dust vermin and weather proof out door compartmentalized feeder pillar of suitable size made of 14 SWG M.S. sheet complete with the following :- a) Canopy at top b) Hinged door open able on both side with heavy duty locking system :- 02 nos c) Base frame with detachable cover on all side made out of 14 SWG steel sheet. d) Legs of suitable length made out of 40mmx40mmx6mm angle iron i/c grouting the legs in 1:2:4 CC (1 Cement 2 Coarse sand 4 stone aggregate of 40mm nominal size). e) Knock out holes at bottom for cable entry f) Earthing stud-02 nos g) One coat of primer and two coats of approved make & colour of synthetic enamel paint. h) 40 amps TPN MCB,16 K breaking capacity -01 No. i) 40 Amps TP air brake contactor - 01 No. j) 24 hour Electronic timer – 01 No. k) Heavy duty godown lock – 02 Nos. l) power tool control with 02 nos 09 Amps contractors m) raise/lower push button n) Termination incoming/ outgoing cables with suitable sizes of ferrules compression gland. o) Motor starter with contactor, bimetallic relay, single phasing preventer – 1 Set
Design and casting of RCC Foundation suitable for erection of high mast as per manufacturers recommendation considering safe soil bearing capacity including supplying and casting foundation anchor plate and templates, foundation bolts manufactured from special steel along with nuts, bolts washers etc including excavation as req. for a) 12 meter High Mast.
Design and casting of RCC Foundation suitable for erection of high mast as per manufacturers recommendation considering safe soil bearing capacity including supplying and casting foundation anchor plate and templates, foundation bolts manufactured from special steel along with nuts, bolts washers etc including excavation as req. for a) 16 meter High Mast.
M/L highly efficient high power LED street light with lense aesthetically designed fitting with pressure die cast aluminum housing top opening service cover, reflector and enclosed with toughened glass IP-66 protection suitable to mount on 40mm dia mast along with wiring with copper wire of suitable size 150 watt conforming to IS-10322 part 5 section 3 2012) Havells,Wipro, osram, Philips.
M/L highly efficient high power LED street light with lense aesthetically designed fitting with pressure die cast aluminum housing top opening service cover, reflector and enclosed with toughened glass IP-66 protection suitable to mount on 40mm dia mast along with wiring with copper wire of suitable size 120 watt conforming to IS -10322(part 5/Section 3 2012) Havells,Wipro, osram,Philips.
M/L XLPE insulated armoured cable with aluminum conductor 1100 Volt grade cross section area 35 x 3-1/2 core .
M/L Bus-bar chamber consisting of three phase and neutral aluminum strips of 100 Amp Capacity including connections with thimbles complete as specified
Removing excavated material 1.50 km but n. exc. 5 Km and depositing where required
Laying of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning protective covering & refilling the trench
Upto 35 Sqmm
Above 35 Sqmt upto 95 Sqmm
Supply only of XLPE insulated aluminium armoured, heavy duty power cable 1.1 kv grade of following size
50 sqmm size 4 core
95 sqmm size 4 core
25 sqmm size 4 core
16 sqmm size 4 core
Demolition of concrete/RMC of any description and in any position not otherwise specifically provided for
Providing fixing enclosure of size 1.50x1.50x1.80 high for High Mast light made up of frame of MS angle of size 40x40x6 of welded wire mesh, opening size 75x25xmm and dia of wire 4mm with one door and lockable arrangement for the protection of panel and switch gear of high mast light as specified & directed by Engineer-in-Charge.
Electric Motor with pulley, other accessories and operating arrangement 1 HP 3 phase 440 volts suitable to take up and down the GI head frame carriage with light fittings up and down for maintenance as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60x60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5m below normal ground level, connected to galvanized earth strip 25 x 3mm by means of both nuts check nuts and washer of galvanised iron or steel including concrete chamber of PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) PCC with fair finish internal surface of concrete chamber will be given 15 mm thick plaster in CM 1:4, funnel with wire guage of (0.68) 8 mess 80 mm thick RCC pit cover 320x 320 mm of RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) re-inforced with Jalli and including necessary charcoal dust and common salt all as shown electrical as per DSR (E&M) latest specifications and specified including provision of earth wire protected by 40mm dia medium grade pipe and watering pipe shall be 20mm dia medium grade including all excavation and earth work in any type of soil and connecting earthing to an earthing test point to main panel board and testing on completion all as specified & directed by Engineer-in-Charge. Note :- RCC pit cover shall be of pre cast RCC (1:2:4) type-B-1 80mm thick re-inforced with jalli weighing not less than 4 kgs/sqm in lieu of CI cover.
Earth continuity aluminium strip of size 25x5mm to be fixed to mast or any to other indicated situation as specified and directed by Engineer-in-Charge.
Boring hole horizontally under ground at required level with trenchless digging machine or manually suitable to pass 80 mm dia MS pipe in the bored hole under the road including passing of cable of size 3-1/2 x 35 sqmm and disposal of spoil to a distance n exc 125 m all as specified and directed by the Engineer in Charge (MS pipe and fitting measured and paid separately).
S.F and laying into horizontal bore hole under the road 80 mm dia MS pipe heavy duty 4.5 mm wall thickness, welded and socketed ends as specified and directed by Engineer in-Charge.
S/F testing commissioning of aviation obstruction lighting fixture with two 40W neon lamps yellow painted die cast aluminium alloy housing built in 75 VA step up transformer , heat resistant, clear thick glass and accessories aviation light including wiring from the feeder pillar to top of the mast as specified and directed by Engineer-in-Charge
S.F of the following in the in built box of mast for jointing cables for controlling the lighting system as specified and directed by Engineer-in-Charge (a) MCCB 63 Amp – 1 No. (b) Male female box – 01 No. 63Amp
M/L lighting arresters expulsion type complete with all fittings ,30 kilo Amp discharge capacity, distribution class
M/L 100mm thick cement concrete type D-2 1:4:8 (1 cement : 4 coarse sand : 8, 40mm thick stone aggregate) in sub base of flooring
M/L 100 mm thick cement concrete type A-1, 1:1.5:3 ( 1 cement : 1 ½ coarse sand : 3, 20 mm thick stone aggregate for flooring & finished without using extra cement.
Painting with synthetic enamel paint of enclosure of size 1.5x1.5x180M high made up of frame of MS angle of size 40x40x6mm of welded mesh of wire of 4mm dia for protection of panel, alongwith painting of timer panel including prepairing surfaces suitable to received the pain as specified and directed by Engineer-in-charge
Bidder Name
Amount
MINHAS CONSTRUCTIONS (GSTN-07AAQPM5739A1ZL) BID ID -3277745
AMIT ASSOCIATES (GSTN-07ACUPG0847K1Z7) BID ID -3278071
L G BUILDERS (GSTN-07AHYPG2256R1ZG) BID ID -3278075
LUMOS INFRA PVT LTD (GSTN-09AACCL9983E1Z1) BID ID -3278330
AMIT ASSOCIATES (BID ID -3278071)
LUMOS INFRA PVT LTD (BID ID -3278330)
MINHAS CONSTRUCTIONS (BID ID -3277745)
AMIT ASSOCIATES (BID ID -3278071)
MINHAS CONSTRUCTIONS (BID ID -3277745)
LUMOS INFRA PVT LTD (BID ID -3278330)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .