Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹25.9 L+₹98,365 (3.94%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹26.6 L+₹1.7 L (6.61%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹26.7 L+₹1.7 L (7.01%)Rejected-Finance HOUSE NO 87 SHAH FAISAL ABAD DHOBI MOHALLA BATAMALOO SRINAGAR 190009 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190009 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹29.2 L+₹4.2 L (17.0%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹34.5 L
EMD Value
₹69,000
Closing Date
25 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE 134 Wks Engr
HQ 134 Wks Engr PIN 914134 C/o 56 APO
REPAIR / MAINT OF HT UG CABLES, HT POLES, HT EXTERNAL ELECTRIC, REPLACEMENT OF HT CONDUCTOR AND OTHER CONNECTED WORKS AT HQ CIF (K) UNDER AGE (I) CIF (K)
2022_MES_524566_1
134WE-08(T)/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Srinagar
please refer tender documents
9 documents required · 9 mandatory
₹500
Yes
AGE (I) CIF (K)
₹69,000
Yes
1 Aug 2022
18 May 2022
27 Jun 2022
18 May 2022
25 Jun 2022
8 Jun 2022
18 May 2022 - 24 May 2022
60 days
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation for erection of poles, stays, laying cables etc and getting out in hard / dense soil, complete all as specified and directed.
All as per Srl item No. 1.00 above but depth exceeding 1.50 metre and not exceeding 3.0 metre.
Returning, filling in excavated earth/soil including spreading, levelling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed.
Removing excavated soil to a distance not exc 50 metre and depositing where directed at a level not exc 1.5 metre above the starting point, complete all as specified and directed.
M&L for dry river sand, laid in trenches for cable protection, as 15cm thick below the cable and 8cm thick above the cable, complete all as specified and directed. Note :- Punned thickness of sand shall be measured & paid.
M&L for sub class 'B' brick covering protection to the eletric cable, laid dry, flat, transversally along the length of cable on sand cushioning with width equal to length of brick, complete all as specified and directed.
M&L for 80mm bore GI water tubing, light grade for road crossing, cable protection, laid in trenches or fixed to wall with suitable clamps and including taking up or down old exisiting tube, complete all as specified and directed.
All as per Srl item No. 7.00 above but 100mm bore pipe.
M&L for PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregates) as in foundation, mass concrete etc including necessary form work, complete all as specified and directed.
M&L for PCC 1:3:6, type C-2 (using 40mm graded crushed stone aggregates) as in foundation, coping etc including necessary form work, complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in coping etc. including necessary form work, complete all as specified and directed.
Dismantling old and unserviceable prestressed concrete poles of any type including breaking cement concrete complete and supply and erection new steel tubular swaged pole with cast iron base plate finial tapper plug, bolts, nuts and screws and type 410-SP-55 (11 mtr long) in truly vertical position 1.5 mtr length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30cm width (black and yellow alternatively) and painting complete with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts, complete all as specified and directed by Engr-in-Charge. Note :- Earth work and PCC shall be measured and paid seperately under respective items of BOQ.
Dismantling existing old unserviceable ACSR conductor of any size and any description and S&F new ACSR conductor including stringing through existing RCC/ steel poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc. complete of different sizes, complete all as specified and directed. Note :- Rates for new aluminium tape / copper binding wire shall be deemed included in quoted rates.
S&F mild steel cross arms channel, bracing, support, clamps etc, fabricated from structured steel, sections including nuts, bolts, washers etc and cutting to required length beat to any shape, drilling holes, fixed on poles or jointed by means of elect welding complete including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer after preparation of surfaces including taking down / dismantling the old items, complete all as specified and directed.
Dismantling of existing old unserviceable earth wire and gradle guard of any size from any position and S&F new GI wire 4mm dia (8 SWG) on poles to continuous earth wire and cradle guard etc, complete all as specified and directed.
M&L for stay assembly complete with 20mm dia stay rod with accessories, shown in electric plate No. 01 including stay clamps and including dismantling old unserviceable stay assy, complete all as specified and directed. Note :- Loop insulator, stay wire, excavation and cement concrete shall be measured and paid seperately under respective items of BOQ.
S&F in replacement galvanised stay wire of size 7/4mm, complete all as specified and directed.
S&F in replacement loop insulator, vitreous porcelian white or brown of size 90mm X 140mm, clearance hole 25.5mm, complete all as specified and directed.
S&F in replacement disc type porcelain vitreous brown or white insulator, suitable for 11 KV HT working pressure, size 145mm height and 255mm dia including one galvanised mild steel spindle, two galvanised iron washer and one GI nut, complete all as specified and directed.
S&F in replacement pin type porcelain vitreous brown of white insulator, suitable for 11 KV HT of working pressure, size 150mm height and 150mm dia including one galvanised mild steel spindle, two galvanished iron washer and one GI nut, complete all as specified and directed.
S&F in replacement shackle type porcelain vitreous brown or white insulator of size 150mm dia and 150mm height including GI strap of size of 38x5mm, insulator bolt of 14mm dia, nuts and washers for working pressure 1100 Volts, complete all as specified and directed.
Taking down triple pole mechanism complete with DO Fuse unit from the site and Supply and Install new DO fuse unit triple pole, mechanically operated, mounted on insulator and steel frame with opertaing mechanism worked from ground level with GI pipe medium grade, for current rating upto 200 Amps and air break (switch) insulator suitable for HT 11 KV, outdoor type 50 Amps (DO Fuse), complete all as specified and directed. Make :- Atlas / GEC / Pactil
S&F in replacement lightning arrester, expulsion type complete with all fittings transmission class, discharge capacity 65 kilo Amps, suitable for 11 KV, complete all as specified and directed.
S&F in replacement cable jointing kit for 11 KV grade cable, Straight through joint, heat shrink type joint, complete with jointing material and accessories, suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, complete all as specified and directed. Make :- 3M / Birla / Denson
S&F in replacement cable jointing kit for 11 KV grade cable, Straight through joint, heat shrink type joint, complete with jointing material and accessories, suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and directed. Make :- 3M / Birla / Denson
S&F in replacement cable jointing kit for 11 KV grade cable, Indoor termination, heat shrink type joint, complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, complete all as specified and directed. Make :- 3M / Birla / Denson
S&F in replacement cable jointing kit for 11 KV grade cable, Indoor termination, heat shrink type joint, complete with jointing material and accessories, suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and directed. Make :- 3M / Birla / Denson
S&F in replacement cable jointing kit for 11 KV grade cable, Outdoor termination, shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, complete all as specified and directed. Make :- 3M / Birla / Denson
S&F in replacement cable jointing kit for 11 KV grade cable, Outdoor termination, shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and directed. Make :- 3M / Birla / Denson
Supply, laying, testing and commissioning XLPE PVC insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed) of size 3 Core 95 Sqmm, laid in trenches / floor / duct / fixed on poles / through GI tubing in different locations / areas, complete all as specified and directed.
All as per Srl item No. 30.00 above but cable size 3 Core 120 Sqmm.
All as per Srl item No. 30.00 above but cable size 3 Core 150 Sqmm.
M&L for earthing complete with GI earth plate of size 60cm x 60cm x 6mm thick electrode, burried directly in ground (earth pit not less then 2.25 metres deep below from ground level) with top edge of the plate not less then 1.5 metre below normal ground level, conneceted to GI strip of size 25x4mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 03 and including earth work, PCC pit and RCC cover, watering pipe of 20mm bore light grade, funnel, wire mesh, charcoal dust, 40mm bore light grade protection pipe and salt etc. and connected to earthing test point, complete all as specified and directed and testing after completion.
M&L for carrying out primary & secondary injection test of 11 KV indoor / outdoor type current transformer (Set of three) of VCB's by using standard injection test method and checking the electrical circuits for fault condition, all relay testing and proper functioning including submitting the test report, complete all as specified and directed by Engineer-in-Charge. Note :- PIT/SIT for VCB will be carried out in 6 months intervals and each primary & secondary injection test shall be measured and paid.
S&F in replacement the following spares for indoor VCB 11 KV 630 Amps :-
Closing coil 24/30V DC.
Tripping coil 24/30V DC.
Antipumping device 24/30V DC.
11 KV porcelain bushing for VCB top.
11 KV porcelain bushing for VCB bottom.
Connector strip 16 way.
Earth fault and over current relay.
Digital type power factor indicator meter.
Digital type Voltmeter / Ammeter of size 96mm x 96mm.
LED type indicator lamp assembly.
Vacuum Interrupter for indoor VCB.
Spout incoming side.
Spout outgoing side.
Epoxy insulators bushings for incoming / out going cables / bus bar supports as per existing size of VCBs.
Insulated copper bus bar of existing size and thickness for VCBs.
Gear system assy complete with handle for charging / discharging of VCBs.
Spring charging motor for VCBs.
Dismantling old and burnt out PT unit 11000/110 volts draw out type, epoxy resin cast type taking out contact with lead and bushing from the bus bar and PT, replacing by new one of same model suitable for 11 KV VCB including testing on completion, complete all as specified and directed. Make :- Crompton or as per existing make as approved by GE.
S&F in replacement temperature gauge, suitable size for power transformer / AVR of any capacity, complete all as specified and directed.
M&L for PVC sleeves suitable for LT/HT ACSR conductor / jumper in any type in RYB colours, superior quality inserted over the existing ACSR, complete all as specified and directed.
M&L for coarse aggregates (broken stone or boulders) of size 40-80mm, laid or filling in sub station yard, complete all as specified and directed.
S&F in replecement drop out (DO) fuse unit, expulsion type, outdoor three pole 200 Amps suitable for HT 11 KV, comprising of 6 Nos post insulators, GI steel base mounting frame, GI nut bolts etc. with 30A, HT barrel type fuse, complete all as specified and directed.
S&F in replacement transmission class type drop out fuses 11000 volts rating 25-50 Amps, outdoor type, complete all as specified and directed.
S&F in repair / replacement of plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment cut to required shape and size for cable duct or any other description, confirming to Fe- 410-W (Gde-E-250) quality 'A', complete all as specified and directed.
Re-stringing only existing HT 11 KV / LT OH line / Jumpers including dismantling of existing old binding wire for tightening, complete all as specified and directed. Notes :- (a) Re-stringing of each wire shall be measured as in RM. (b) New binding wire shall be measured and paid separately under respective item of BOQ.
M&L for removing vegitation, grass, scrubs, creepers and bushes growing in Sub Station yard, around the poles/stays, along with fancing etc. by manually / mechanically and keep the sub station yard neat and clean, complete all as specified and directed. Note :- Quoted unit rates shall be included to keep the installation neat and clean through out the period of contract and each cleaning shall be measured and paid separately.
M&L for cutting and trimming of tree branches of girth 25mm to 75mm upto 3 mtr all around of any size which is obstructing illumination of street light and touching LT / HT OH line by using required tools and plants including removing trimmed tree branches, complete all as specified and directed. Notes :- (a) Each cleaning/cutting shall be measured and paid separetely. (b) All T&P and machineries shall be included in quoted rates.
S&F in replacement insulating rubber mat, ISI Marked of size 1 mtr x 2 mtr x 19mm thick, suitable for 11 KV at MRS & SS 1 OF R&O.
M&L for preparation of old surface, cleaning of the steel pole (HT), 11 Mtr long pole structures above the ground level including coping area and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and it's connected parts, complete all as specified and derected.
Supply and filling fresh transformer power oil of BDV not less than 50 KV for topping up of reduced level of transformer due to evaporation / leakage / losses due to dehydration in HT 11KV distribution transformer 100 to 600 KVA and including removing / taking up old unservicable transformer oil, complete all as specified and directed.
M&L for conducting oil filtration by stream line / vacuum type filter machine to remove the moisture / carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for power transformer & as BDV of oil 40 to 50 KV for 1 min for distribution transformer including routine testing after filtration for any capacity of transformers / AVR / CT / PT units, complete all as specified and directed. Notes :- (a) The contractor shall change the filter assy before starting the filtration of transformer / AVR of capacity 600 KVA and more capacities in presence of Engr- in-Charge). (b) Necessary documention should be submitted by the contractor to Engineer-in-Charge.
S&F in replacement brass terminal rod with nuts, bolts, washers & bushings, suitable for HT side of the transformer of any make and capacity from 100 KVA to 300 KVA, complete all as specified and directed.
All as per Srl item No. 50.00 above but LT side.
S&F in replacement brass terminal rod with nuts, bolts, washers & bushings, suitable for HT side of the transformer of any make and capacity from 315 KVA to 400 KVA, complete all as specified and directed.
All as per Srl item No. 52.00 above but LT side.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 315 KVA transformer, complete all as specified and directed.
M&L for painting the outer surface of the transformer with one coat of weather proof paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc, paint free after painting including writing the MES/SM Number with white enamelled paint, complete all as directed for capacity of transformer 100 KVA to 400 KVA (Indoor/outdoor type), complete all as specified and directed.
M&L for repair to transformer step down 11 KV / 0.433 KV of any type and capacity 250 KVA to 400 KVA, after dismantling the transformer body carefully, opening the top cover of transformer for inspection / repair, drain out the transformer oil from the tank complete, taking out the core and winding assy by disconnecting the internal connections, removing the carbon / sludge deposit in transformer housing core, renewal / replacement of unsv rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, warnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, painting of complete transformer body from outside and inside by weather proof paint using spray gun, Marking of MES/SM Number etc, replacement of conservator tank glass, reintalling the core and winding inside properly, making the all connection with suitable copper lugs, refilling of dehydrated transformer oil including dehydration, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc. Meggering the LT and HT side of the transformer and testing after completion of job, complete all as specified and directed by Engr-in-Charge. Note :- Winding wire including labour for making of coils and LT/HT bushes shall be measured & paid seperately.
M&L for super enamelled copper conductor wire of suitable gauge and size as per requirement for rewinding the HT/LT transformer of any make, complete all as specified and directed.
M/S YATTOO CONTRACTORS
M/S Noor Mohammad Shalla
M/s Lal Enterprises
CHINAR CONSTRUCTION TRADERS
M/S Sky Engineers
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .