Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC 2 8 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹16.2 L+₹1.2 L (7.80%)Rejected-Finance | L2 | Rejected-Finance BIDDER NOT LOWEST | |
| 3 | L3₹20.6 L+₹5.6 L (37.1%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L3 | Rejected-Finance BIDDER NOT LOWEST | |
| 4 | L4₹21.5 L+₹6.5 L (43.0%)Rejected-Finance | L4 | Rejected-Finance BIDDER NOT LOWEST | |
| 5 | L5₹22.0 L+₹7.0 L (46.5%)Rejected-Finance | L5 | Rejected-Finance BIDDER NOT LOWEST |
Tender Value
₹43.3 L
EMD Value
₹86,600
Closing Date
21 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST DELHI CANTT 10
GE WEST DELHI CANTT 10
COMPREHENSIVE MAINTENANCE OF E M NATURE OF WORKS IN MOHAN ENCLAVE CMP LINE CAPT LINE UNDER GE WEST DELHI CANTT 10
2022_MES_520773_1
GE/DW-52/2022-23
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE WEST DELHI CANTT
₹86,600
10 Sept 2022
25 May 2022
23 Jul 2022
26 May 2022
21 Jul 2022
7 Jul 2022
90 days
Amount
Checking and attending complaints in JCOs and ORs Married Accn in Mohan Enclave area and CMP Line,Capt Line area by means of repairing/rectifying the electric defects/faults related to elctrical equipments ,devices,accessories and fixtures maintained by MES .Tightening the loose connections complete all as specified and directed. Note : (a) The contractor has to be deployed minimum two electrician and two helper for the subject work or as drected by Engr-in-Charge and the electrician deployed by the contractor shall have good knowledge in concerned trade.Helper deployed shall have min 8th passed. (b) This item covers cost of labour for attending complaint and taking down of old material and cost of minor items such as screw, guitty,flexible wires up to 0.5 m for repair works for each complaints where required. (c). Item to be replaced under this item shall be either isued free for fixing or shall be contractor supply under respective items of this schedule. (d) Complaints noted'' NO Light'' shall be attended imediately up to 2200 hrs without fail,failing which recovery of Rs.240/ per complaint shall be effected from the RARs/ F Bill. (e)The complaints shall be attended & defects shall be rectified within 08 hrs from date and time of notifying the complaint. (f) Contracror shall arrange suitable T&P for work and safety measures complete all as specified and directed (g) Contractor or his rep will report daily at complaint cell for collection of complaints from the concerned JE's incharge,in case any defects, which is not possible to rectfy the defects within 08 hrs, same shall be brought to the notice of Engineer in charge by the contractor/his rep immediately. (h) Labour charges for this item shall not be included under items which includes 'M&L','S&F' in repair',fixing only /Fixing in repair etc in respective item of this Schedule/BOQ. (j) Job slip as per sample shall be provided by the contractor free of cost. The contractor is advised to inspect site and to note that he has to deploy daily men power to collect the complaints from complaint cells. Contractor's quoted rates shall deemed to be included this fact into account and nothing extra shall be admissible on this account. (k) All Items Required to replace such as switches,sockets,call bells,Bell push,Capacitors,Plug Tops,Metal clad sockets,ceiling roses,light fittings,fan regulators,MCBs,MCB DB's,MCCB's,security lights,all materials except fixing accessories etc any capacity shall be measured and paid seperately and no labour charges shall be paid under respect items of this BOQ (l) Item required to replace in repairs based on Day to Day complaints by the users as when as required as site. (m).Old unserviceable material obtained from site against issued by the department to be deposited to MES store Yard. (n). Minor items such as screw,gitty,flexible wire etc for day to day use shold (o) Labour charges for this item shall not be included under items which includes 'M&L','S&F' in repair',fixing only /Fixing in repair etc in respective item of this Schedule/BOQ.
M & L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 6 Sqmm in and including PVC conduit for submain wiring and connection complete including rigid PVC conduit FRLS grade,unsheathed copper conuctor cable of 4 Sqmm size stranded conductor as earthwire,including taking down complete all as specified and directed.
M & L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 10 Sqmm in and including PVC conduit for submain wiring and connection complete including rigid PVC conduit FRLS grade,unsheathed copper conuctor cable of 6 Sqmm size stranded conductor as earth wire, including taking down complete all as specified and directed.
Taking down carefully ceiling/exhaust fan from its position after disconnecting electric connection and checking it for its serviceability and refixing after carrying out necessary repairs to fans/exhaust fans under respective items here-in-after and all as specified and directed.
M&L for opening up the winding of ceiling fan 1200 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Testing of the ceiling fan after refixing in position to the entire satisfaction complete all as specified and directed.
M&L in for opening up the winding of Exhaust fan 300/250 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Testing of the ceiling fan after refixing in position to the entire satisfaction complete all as specified and directed.
S&F in repair exhaust fan blade of any make for size 225 mm to 300 mm sweep as per requirement at site complete all as specified and directed.(As per sample)
S&F in repair ceiling fan blade 1200 mm sweep made up of aluminium body having provision of free size monting nuts/screw all as per requirement at site complete all as specified and directed.
Supply and fix in Repair PVC fresh air fan 225/250 mm motor as per sample complete all as specified and directed.
Supply and fix in Repair PVC exhaust fan 300 mm motor as per sample complete all as specified and directed.
S&F in Repair SS braided pipe of 12 mm (internal dia) suitable for hot/cold water, 450 mm long with brass nuts and rubber washers complete all as specified and directed.
S&F in Repair heating element of 1.5/ 2.0 KW, for 25 Ltr Racold Geyser as per exsting sample with nut, bolt and washers complete all as specified and directed.
S&F in Repair thermostat of for 25 ltrs capacity of Racold Geysers as per exsting sample with nut, bolt and washers complete all as specified and directed.
S&F in Repair copper inner tank of 25 Ltrs capacity Racold Geysers as per exsting sample with nut, bolt and washerscomplete all as specified and directed.
M&L in Repair sluice valve/gate valve CI circular spindle with nut and bolts of size 40mm complete all as specified and dircted.
M&L in Repair sluice valve/gate valve CI circular spindle with nut and bolts of size 50mm complete all as specified and dircted.
M&L in Repair sluice valve/gate valve CI circular spindle with nut and bolts of size 80mm complete all as specified and dircted.
M&L in Repair brass B22 cap holder as per sample complete all as specified and dircted.
M&L in Repair ceiling fan capacitor 3.15/2.50 Mf as per sample complete all as specified and dircted.
M&L in Repair exhaust fan capacitor 1.50 Mf as per sample complete all as specified and dircted.
M&L in Repair fresh air fan capacitor 1.0 Mf as per sample complete all as specified and dircted.
M&L in Repair Earth leakage circuit breaker (ELCB) TPN 63Amp,3 phase 4 pole 100 mA,ISI marked as per sample complete all as specified and dircted.
M&L in Repair Earth leakage circuit breaker (ELCB) SPN 32Amp,single phase 2 pole 3 to 50 mA,ISI marked as per sample complete all as specified and dircted.
M&L in Repair pvc fresh air fan 225/250mm outer body as per sample complete all as specified and dircted.
M&L in Repair pvc fresh air fan 225/250mm blade as per sample complete all as specified and dircted.
M&L for painting of ceiling fan 1200/1400 mm sweep complete with synthetic enamel paint by spraying includind filling cavities with filler, one coat after cleaning all dust complete all as specified and directed.
S&F in repair top cover for Geysers (confirming to IS) suitable for any make/capacity/type of Geysers installed at site complete all as specified and directed.
S&F in repair bottom cover for Geysers (confirming to IS) suitable for any make/capacity/type of Geysers installed at site complete all as specified and directed.
S&F in repair cover outer for Geysers (confirming to IS) suitable for any make/capacity/type of Geysers installed at site duly painted with two quotes with enamel (Deco) paint of colour & shade complete all as specified and directed.
M&L for soldering and brazing inner copper tank of any capacity with brass solder and refixing complete (taking down and fixing shall be paid under ref item above) complete all as specified and directed.
S&F in repair stainless Steel flang assembly for geyser of 25 Ltrs capacity as per sample complete all as specified and directed.
S&F in repair of safety pressure valve of size 15 mm dia, with washer ISI marked for Geysers complete all as directed by Engr-in-Charge.
S & F in repair hole fastner madeup of MS 6" long with complete nut bolt complete all as specified and directed.
S & F in repair hole fastner madeup of MS 4" long with complete nut bolt complete all as specified and directed.
Taking down carefully copper/aluminium point wiring from wooden battan or conduits (light, fan, socket or power) complete including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc.complete all as specified and directed.
M&L point wiring in existing conduit with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing in & including rigid PVC conduit FRLS grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover for terminal boxes also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly and making good to the disturb surfaces with cement, matching with existing color by painting all as specified for the following :-
(a) One light/fan/bell point controlled by one by one way switch ( switch to be measured and paid separtely)
(b) One light point controlled by two, two way switch ( switch to be measured and paid separtely)
(c) One 3 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable as earth wire connected to common earth and to earth dully socket & switches to be measured and paid separately.
(d) -ditto- as above item No 37 but Same board.
M&L One power point in existing conduit with insulated stranded copper conductor cable 2.5 Sqmm single core and PVC insulated FRLS 1100 Volts unsheathed copper conductor 1.5 Sqmm stranded conductor as earth wire connected to dolly complete ( socket and switches to be measured and paid separately)
M&L point wiring concealed in wall with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing in & including rigid PVC conduit FRLS grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover for terminal boxes also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly and making good to the disturb surfaces with cement, matching with existing color by painting all as specified for the following :-
(a) One light/fan/bell point controlled by one by one way switch ( switch to be measured and paid separtely)
(b) One light point controlled by two, two way switch ( switch to be measured and paid separtely)
(c) One 3 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable as earth wire connected to common earth and to earth dully socket & switches to be measured and paid separately.
(d) -ditto- as above item No 10 but Same board.
M&L One power point concealed in wall with insulated stranded copper conductor cable 2.5 Sqmm single core and PVC insulated FRLS 1100 Volts unsheathed copper conductor 1.5 Sqmm stranded conductor as earth wire including PVC cunduit connected to dolly complete all as specified. ( socket and switches to be measured and paid separately)
M&L switch piano flush type 5 Amp SP one way complete all as specified and directed.
M&L switch piano flush type 5 Amp SP two way complete all as specified and directed.
M&L switch piano flush type 15 Amp SP one way complete all as specified and directed.
M&L socket outlet 5 pin 5 Amp flush type complete all as specified and directed.
M&L socket outlet 2 in 1,3 pin 5/15 Amps complete all as specified and directed.
M&L ceiling rose 3 phase PVC polycorbonate,insulated body complete all as specified and directed.
M&L electronic fan regulator 5 step connecting complete all as specified .
M&L bell push,flush type,5 amp complete all as specified and directed.
M&L bell ding dong AC,230 volts,single pole complete all as specified and directed.
M/L insulated body, angle holder (metal ring) with back plate ISI marked complete all as directed.
S&F in repair GI Pipe bracket bent to shape drilled welded made out of light grade GI pipe 25mm dia 1.5 mtr long and fixing on the wall where as directed by the Engr-in-Charge for fixing of building security light fitting including clamps, nuts, bolts and washers etc complete all as specified by the Engr-in-Charge .
M & L in repair earthing complete with copper earth plate 600x600x3.15mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to 20x3mm copper strip by means of bolts, nuts, check nuts and washers of copper strip and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 40mm bore for copper strip, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) with MS handle and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) including testing on completion all as directed .
Supply & Fix in repair LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed.
Supply and fix in repair Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix in repair Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix in repair 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Deduct Credit: for demolished/dismantled material of (-) Rs 178685.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum
GAUTAM ELECTRIC WORKS
M/s Adhikari construction co.
SETHI ENTERPRISES
RAMGARHIA CONSTRUCTION CO
M/s Krishna Construction Co.
M/s S.G. BUILDERS
Grid Infratech Pvt Ltd
Surjit and Sons
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .