Providing AMC for 2 nos 125 EA set and IP Based CCTV
6878888
GEM/2024/B/5376189
Two Packet Bid
Providing AMC of 2No 125KVA,Providing AMC of 2No 125KVA Engine alternator set,Servicing BCheck of 1
30 days
Karnataka; Kolar
Total value wise evaluation
BOQ
11 documents required · 11 mandatory
3 yrs
₹3
50%
Exempted
21 Sept 2024
9 Sept 2024
21 Sept 2024
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Providing AMC of 2No 125KVA | Providing AMC of 2No 125KVA Engine alternator set with all accessories such as battery charger battery control panel MCCBs MCB meters and switch gears silencer Engine safety devices meters Fuel lines including preventive maintenance and monthly visiting and checking of all accessories such as radiator fan fan belt AVR water level battery charging dynamo charger unit self starter Control panel Replacement spares in case of faults rewinding of alternator AVR control panel accessories | 12 | Month | SK Elavazhagan 563101,BSNL Telephone exchange ,Kanakanpalaya Kolar, Kolardistrict. | 30 |
| 2 | Providing AMC of 2No 125KVA Engine alternator set | Providing AMC of 2No 125KVA Engine alternator set with all accessories such as battery charger battery control panel MCCBs MCB meters and switch gears silencer Engine safety devices meters Fuel lines including preventive maintenance and monthly visiting and checking of all accessories such as radiator fan fan belt AVR water level battery charging dynamo charger unit self starter Control panel Replacement spares in case of faults rewinding of alternator AVR control panel accessories by deputing service engineer or mechanic etc as reqd | 12 | Month | SK Elavazhagan 563101,BSNL Telephone exchange ,Kanakanpalaya Kolar, Kolardistrict. | 30 |
| 3 | Servicing BCheck of 1No100 KVA EA Set | Servicing BCheck of 1No100 KVA EA Set complete draining out engine oil from sump ic replacement of fuel filter oil filter bypass filter refilling of new 15W40 grade lube oil coolant and cleaning of DG set and accessories applying petroleum jelly on battery terminal posts checking of Vbelts mounting bolts coupling arresting of oil fuel leakage test running recording of lub oil pressure RPM Voltage frequency checking of radiator water level topping up of coolant Radiator fan checking radiator service etc as required Note 1B Check original report submitted duly signed by the Engineer in charge 21st B Check to be carried out within 15 days thereafter every 12 month of DG run hour | 1 | No | SK Elavazhagan 563101,BSNL Telephone exchange ,Kanakanpalaya Kolar, Kolardistrict. | 30 |
| 4 | Supplying and Fixing of 12V 130AH battery | Supplying and Fixing of 12V 130AH Heavy duty Lead acid sealed maintenance free battery with initial charging on buy back basis suitable for Genset cranking duty with Manufacturer warranty of Minimum 24 Months shall be replaced as per the direction of Engineer in charge etc as required | 4 | No | SK Elavazhagan Supplying And Fixing Engine 563101,BSNL Telephone exchange ,Kanakanpalaya Kolar, Kolardistrict. Control Unit Controller | 30 |
| 5 | Supplying and fixing Engine control unit Controller | Supplying and fixing Engine control unit Controller suitable for the existing 125 kVA DG Set Make Ms Ashok Leyland in the Standard manual control Panel including dismantling the faulty one making necessary interconnections testing commisioning etc complete as required | 1 | Job | SK Elavazhagan 563101,BSNL Telephone exchange ,Kanakanpalaya Kolar, Kolardistrict. | 30 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_6878888.pdf
GEM_BID
gemmakes_2024-09-09-12-11-33_1606ed70f680877c65d41e0f233c6b7f.pdf
BOQ
boq32_2024-09-09-12-11-33_c9e75adaa755ea1c1648872061518952.csv
BOQ
1725865179.xlsx
OTHER
GeM32ATC_dc28eeb1-def2-421f-ae5b1725865538976_EEEDMGL.docx
OTHER
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .