Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC | ₹1.7 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.7 Cr+₹7.4 L (4.48%)Rejected-Finance | ₹1.7 Cr+₹7.4 L (4.48%) | L2 | Rejected-Finance Being not L1 |
| 3 | L3₹1.8 Cr+₹15.0 L (9.06%)Rejected-Finance NO157 14 13TH B MAIN ROAD 1ST STAGE 1ST PHASE GOKULA BANGALORE 560054 | BENGALURU URBAN | KARNATAKA | 560054 | ₹1.8 Cr+₹15.0 L (9.06%) | L3 | Rejected-Finance Being not L1 |
| 4 | L4₹1.9 Cr+₹20.3 L (12.2%)Rejected-Finance | ₹1.9 Cr+₹20.3 L (12.2%) | L4 | Rejected-Finance Being not L1 |
| 5 | L5₹1.9 Cr+₹20.8 L (12.6%)Rejected-Finance | ₹1.9 Cr+₹20.8 L (12.6%) | L5 | Rejected-Finance Being not L1 |
Tender Value
₹1.9 Cr
EMD Value
₹2.6 L
Closing Date
18 Oct 2022, 6:00 pmClosed
Col Subhro Banerjee CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
IMPROVEMENT OF MARRIED ACCN AT AIR FORCE STATION, JALAHALLI EAST PHASE IV
2022_MES_548024_1
85232/E8
Open Tender
Civil Works
Item Rate
180 days
GE(M) AF JALAHALLI BANGALORE
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE(M) AF JALAHALLI
₹2.6 L
29 Nov 2022
27 Aug 2022
20 Oct 2022
27 Aug 2022
18 Oct 2022
13 Oct 2022
27 Aug 2022 - 6 Sept 2022
Amount
Demolition of cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and applying neat cement slurry by brush with 3.0 kg of cement per sq. Metre complete all as specified and directed.
Dismantling floor hearth tiling including cement mortar bedding ,removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of reinforced cement concrete in floors ,beams ,chajjas,landing slab in any position or height and similar suspended works all as specified and directed. Note :- Rate quoated shall deemed to include for seperation of old steel bars and stacking at site for measurements.
Demolition of brick work or stone masonry built in cement mortar or cement lime mortar including all quoins, arches etc complete all as specified and directed.
Demolition of cement concrete exc 15 cm thick above ground floors complete all as specified and directed.
Taking down cement plaster and raking out joints, hacking for key,scrubbing down with water built in cement mortar complete all as specified and directed.
Taking down Chowkhat or frames not exceeding 1.5 Sqm each with shutters (Without taking off shutters from the frames.
All as per item 8 above but exceeding 1.5Sqm but not exceeding 4 Sqm each
Taking down shutters of any description exceeding 1Sqm and not exceeding 2 Sqm each.
M & L Plain cement concrete 1:5:10 type E-2 using 40mm graded stone aggregate as in foundation filling and mass concrete in sunken floors all as specified.
M & L 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base, Floors, Paving finished even and fair complete all as specified.
M & L 25mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in flooring finished fair and even without using extra cement.
Material and labour for 25mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as padding for roof surfaces, finished even and smooth complete all as specified and as directed.
M/L for 40mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in flooring finished even and smooth without using extra cement
M&L Providing cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in roof, chajjas, coping, bed blocks and similar work including necessary form work.
M & L for 75mm thick plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregates as in plinth protection finished fair and even, laid in panels all as directed.
M/L reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in slabs and finishing exposed surfaces fair & even all as specified.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape reqired including cranking, bending spirally for hooping for colimns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and all as specified and directed.
Mild steel TMT bars 8mm dia and over, cut to length, bent to shape reqired including cranking, bending spirally for hooping for colimns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and all as specified and directed.
M/L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs,etc. also splays between floors and beams, etc and all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc. 6.00m mean radius built in cement mortor 1:6 and all as specified and directed.
M&L for Rendering 15mm thick in CM 1:4 on fair faces of brick/stone masonry surfaces mixed with water proofing compound to be finished even & smooth without using extra cement. Note : WPC shall be measured & paid seperately
M&L for taking down of existing sunken slab treatment from the sunken portion and removing of existing filling of sunken, cleaning the surfaces washing down with water and rubbish off the primises, cleaning and filling cracks with sealing compound, brushing neat cement [email protected]/sqm and grouting 25mm thick cement concrete type B-0 1:2:4 using 12.5mm graded stone aggregate on sunken slab portion including filling of brick bats and finishing the top surfaces even and smooth without using extra cement . (b) M&L for two coat of acrylic cementitious water proofing coating (Dr FIXIT pidfin 2K manufactured by M/S Pidilite industries Ltd or equivalent) and followed by a overlay protective screed 15mm thick CM(1:3) alongwith liquid water proofing compound approved make on top surfaces of sunken slab after prepration as mentioned above method of application for acrylic cementitious water proofing coating is followed as per manufacturs instruction complete all as specified and directed.
M&L for dubbing out average 15mm thick on irregular face of wall( brick/stone/concrete surfaces) in CM 1:6 complete all as directed.
M&L for rendering 10mm thick in CM 1:3 on fair faces of brick work or concrete surfaces as in backing coat to receive wall tiles etc.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement in two layers 10mm and 5mm respectively and top layer mixed with integral water proofing compound all as per manufactures instruction and all as specififed . WPC shall be measured and paid seperately.
M&L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement all as specififed .
Rendering 5mm thick in CM 1:3 on ceiling on fair faces of brick work or concrete surfaces & finished even and smooth without using extra cement complete all as specified.
M & L for 15mm thick screed bed in CM 1:6 for laying floor finishes.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L glazed ceramic coloured tiles 350x 250x7mm/ 450x 350x7mm thick on vertical surfaces such as skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match
M & L Non skid joint free ceramic coloured tiles 7 to 8mm thick , area of each tiles exc 0.11 sqm but not exc 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match.
All as per item No 33 hereinbefore but in skirting including necessary cutting of tiles complete all as specified and directed.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the salb including rubbing and polishing complete all as specified and directed.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and piller laid over cement screed and jointed with complete all as specified and directed.
M & L keyed pointed in CM 1:4 for squared rubbel masonry all as specified and directed.
Supply only integral water profing compound ISI marked .
M&L for pre- polished granite slab machine cut of any shade as approved by GE of 15 to 20 mm thick including necessary notching, chamfering the edges over cement screed bed including Cutting, Grinding and Mirror polishing(Granite finish) with suitable grinding stones complete all as 'specified and as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations all as specified and directed.
Hacking out old broken glass of any thickness size or description from wooden frames or metal frames fixed with wooden beads/ putty complete all as specified and directed.
4mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm each panes complete all as specified.
M&L for 2nd class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed
S/F 35 mm thick 2nd class hardwood plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treatedboard medium density, wood particle board with commercial face vineers complete all as specified and directed.
S &F 2nd class hardwood 35mm thick glazed and skeleton shutters open rebated and prepared to receive glass gauze etc divided into squares, with plain, chamfered or rounded mitred and rebated sash bars any number edges of framing plain, chamfered or rounded, fitted with cut and metered beads for securing glass etc size of members of shutters as specified in SSR Part I Sec 8 clause 8.24 (a) complete all as specified and directed.
Supplying and fixing of PVC hollow door frame of size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm thick rigid PVC foam sheet, mitre cut at two corners and joined with two nos of 150mm long brackets of 15mm x 15mm MS square tube. The two vertical door profiles are to be reinforced with 19mm x 19mm MS square tube of 19 gauge, EPDM rubber gasket, weather seal to be provided through out the frame. The doorframe shall be fixed to the wall using 65/100mm long MS screws through the frame using PVC fasteners. A minimum of four nos of screws to be provided for each vertical member and minimum of two nos of screws for each horizontal member complete as per Manufacturer’s specification and drawing and as directed.
Supply and fixing factory made solid PVC moulded door shutter 28 to 30 mm thick(stiles), with 2,4 or 6 raised panel board core design with 5mm thick moulded PVC sheet on front face & 5mm thick plain coloured PVC sheet on back face, all as specified and directed.
S&F Steel Window/ ventilators with top hung shutter including hinges, steel peg stay etc complete all as specified and directed.
Dismantling of boarding, any description, fixed in any position with nails (in floor etc) all as specified and directed.
S&F 19/ 20 mm thick Block boards, prelaminated both sides, interior grade, commercial type, fixed with screws to timber frame work all as specified and directed.
S & F 30 mm width of flap Continous (Piano) hinges, mild steel, bright finish or electrogalvanised.
S & F 40mm dia, brass cupboard knobs fixed with nut, screw and washer all as specified and directed.
S & F brass hasp and staple , 125mm safety type with mild steel hinge pin including bolt type all as specified and directed.
S & F 140mm ball catches with 8 mm dia steel ball, and brass body and striking plate including letting in all as specified and directed.
S & F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 all as specified and directed.
M&L framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed.
S & F Stainless Steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with stainless steelwire staples.
S&F 2nd class hardwwod small fittings such as brackets of any type,latch and hinge blocks, shaped door and window stops and the like including all necessary labours, articles not exceeding 200Cu.cm each all as specified and directed.
S & F 150 mm aluminium, anodised, barrel tower bolts of extruded section and fixed
S & F 200 mm aluminium, anodised, barrel tower bolts of extruded section and fixed
S & F 300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed
S&F mild steel 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete
Supply & Fixing 150 mm Aluminium handles, cast type, anodised
Supply & Fixing 125 mm Aluminium handles, cast type, anodised
S & F 100mm size Butt hinges, medium weight, cold rolled mild steel, and fixed.
S & F 50mm size Butt hinges, medium weight, cold rolled mild steel, and fixed.
S & F for mild steel powder coated pelmet rods 25mm outer dia including 2 Nos of brackets, 2 Nos of pintals or side brackets as per site requirement including 10 Nos of curtain rings in each curtain rod complete all as specified and directed.
M&L floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor 150mm.
Taking down cement plaster including existing water proofing treatment any type from roof top complete all as specified and directed.
M&L for screed bed of mortar 15 mm thick in cement mortar 1:4 with WPC over cleaned concrete surfaces. WPC shall be measured and paid seperately.
M&L for water proofing treatment on horizontal and vertical surface with polymeric water proofing membrane at the rate of 4Kg/Sqm reinforced with min160 gram/Sqm non woven polyster mat over a coat of bitumen primer @.20 Ltr/Sqm and a coat of hot blown bitumen of 85/25 or 95/15 @ 1.20 Kg/Sqm applied on the top of Polymeric membrane and finally finished with a coat of bituminous aluminium paint @ of 100 grams/Sqm all specified and directed and testing complete on completion.
Taking up or down steel tubing 15mm bore and connection including cleaning for refixing or removal to store.
Taking up or down steel tubing 20mm bore and connection including cleaning for refixing or removal to store.
Cutting chases, pinning in, making good to facing where reqd and pointing in CM 1:3 to ends of edges of landing etc and cutting chases for concealed water tubing and making good cutting exc 10 cm but n.exc 20 cm girth.
S&F steel tubes medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor bore of pipe 15mm dia. including making hole in RCC slabs for vertical pipes & making good the same with Cement Concrete I:2:4.
S&F steel tubes medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor bore of pipe 20mm dia. including making hole in RCC slabs for vertical pipes & making good the same with Cement Concrete I:2:4.
Refixing 15mm dia old steel tubing and connection in new or old position (wall ceiling floor etc including cutting altering the size or changing the new fittings etc complete all as specified .
Refixing 20mm dia old steel tubing and connection in new or old position (wall ceiling floor etc including cutting altering the size or changing the new fittings etc complete all as specified .
Dismantaling of cast iron / RCC/ PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings all as specified .
S&F for PVC (SWR) floor trap 75mm dia of outlet, plain with grating including jointing with solvent cement fixed as in repairs all as specified .
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls bore of pipe 110 mm with PVC clamps and saddles including taking down existing pipes all as specified .
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in floors, bore of pipe 110 mm with PVC clamps and saddles including taking down existing pipes complete all as specified and directed.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls bore of pipe 75 mm with PVC clamps and saddles including taking down existing pipe complete all as specified and directed.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in floors, bore of pipe 75 mm with PVC clamps and saddles including taking down existing pipes complete all as specified and directed.
S & F PVC (SWR) bends of any radius with access door for bore of pipe 110 mm all as specified and directed.
S & F PVC (SWR) bends of any radius with access door for bore of pipe 75 mm all as specified and directed.
S & F PVC (SWR) reducers for bore of pipe 110 mm all as specified and directed.
S & F PVC (SWR) couplers for bore of pipe 110 mm.
S & F PVC (SWR) couplers for bore of pipe 75 mm all as specified and directed.
S & F PVC (SWR) junction single (single T) equal or unequal with access door bore of pipe 110 mm all as specified and directed.
S & F PVC (SWR) junction single (single T) equal or unequal with access door bore of pipe 75 mm complete all as specified and directed.
S & 110mm bore PVC (SWR) vent cowl all as specified and directed.
S & F PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement complete all as specified and directed.
S & F 110mm dia PVC (SWR) branch piece, single (single Y) equal or unequal all as specified and directed.
S&F in repairs sink with drainage board made of stainless steel 1mm thick with plugs, washer and wastes including fixing in cement mortor 1:3 to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915x460mm,bowl size 410 mmx 330 mmx 160 mm including CP waste coupling all as specified.
S & F Stainless steel Plate rack 900mm x 600 mm x 200mm deep with plate racks, spoon holders, shelves etc complete all as specified and directed.
Supply and fixing in repairs wash down water closet (Pedestal pattern) of size 580mm white with water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and including S or P trap, front or back inlet excluding flushihng cistertn and flush pipe complete all as specified and directed.
Supply and fix in viterous china squatting pan Orrisa pattern size 580 x 440 mm white with "P" and "S" trap front or back inlet etc including provision of PCC (1:5:10) concrete complete all as specified and as directed
S&F toilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.
S&F health faucet, CP, 15mm bore with flexible pipe and all accessories / fittings complete all as specified and directed.
S&F in repair vitreous china white wash hand basin flat back size 550x400mm 'including CI/MS brackets, cutting for and pinning in brackets but excluding waste pipe complete all as specified and directed.
S&F in repairs10 ltrs capacity PVC valveless syphonic action type flushing cistern low level with inlet ball valve float and handle complete all as specified .
S&F in repairs for 15mm dia of pipe bib taps cast copper alloy, fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and directed.
S&F in repairs for 15mm dia of pipe stop valves,fancy type and chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for Unions and fixed complete all as specified and directed.
S&F in repairs for 15mm dia of pipe angle valves,fancy type and chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for Unions and fixed complete all as specified and directed.
Supply and fixing 25 mm dia gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
S & F PTMT shelf with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 300 gms) complete all as specified and directed.
S & F brass chromium plated pillar taps with capstan heads, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipes 15 mm dia all as specified and directed.
S&F in repairs PVC connection 15mm dia and 45cm long with two Nos of brass checknuts and washers complete all as specified and directed.
S&F in repairs brass Choromium plated shower rose with or without swivel joints 125mm size including fixing to steel pipe or union complete.
S&F grating doom 125mm dia with waste hole of PTMT (Min wt 40 gms).
S & F waste coupling of PTMT (half or full threaded) 32 mm dia.
M & L for PVC waste pipe 32 mm dia flexible with cup & pressure rating 6 kgf/cm2 to fit wash hand basin waste coupling complete all as specified and directed by Engr-in-Charge.
Supply and fixing of soap dish PTMT with multiple boxes all as specified and directed by Engr-in-charge
Supply and fixing 100 mm bore stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for nominal bore.
S&F in repairs 600mm long tubular tower rail brass chromium plated 20mm dia, D type 60cm long fixed with two plugs (Gutties) of 2nd class hard wood embeded in cement mortor 1:3 with MS screws complete all as specified.
Supply & fixing Rotational moulded Polyethylene water storage tank, 500 liters capacity (cylidrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I incl PTMT float valve 25mm dia including dismantling of water tank complete all as specified and directed.
M & L for preparation of new surfaces of wall including scrapping down, smoke soot, efflorescenting salts trading oil and greasy spots etc by applying three coats of white wash on walls ( Finishing coat shall be carried out using air less sprey tools) complete all as specified and directed.
Material & Labour for preparation of old surfaces of ceiling including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc (Plastered or unplastered surfaces) and applying one coat of white (lime) wash using air less sprey tools complete all as specified and as directed.
All as per item No 120 above but applying three coats of white wash on new surfaces ( Finishing coat shall be carried out using air less sprey tools) all as specified and as directed.
M&L for preparation of old painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint in any tint all as specified and directed
M & L for applying two coats of synthetic enamel paint over a coat of pink wood primer on new wooden surfaces including preparation of new surface all as specified and as directed.
M&L for distempering walls with two coats of washable distemper oil emulsion on new surfaes(white or tinted) as directed after washing/rubbing down and stopping of distempered and painted surfaces as in preparatory work to give uniform and smooth finish( Finishing coat shall be carried out using air less sprey tools) all as specified.
M&L for distempering walls with one coat of washable distemper oil emulsion on old surfaes(white or tinted) as directed after washing/rubbing down and stopping of distempered and painted surfaces as in preparatory work to give uniform and smooth finish using air less sprey tools all as specified.
M&L for prepration of new steel surface and iron work of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed .
M&L for prepration of old painted steel surface and iron work of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint all as specified and directed .
Material & Labour for preparation of new plastered or un- plastered surfaces and walls including cornices, pilasters etc and applying two Coats of cement base paint ( Finishing coat shall be carried out using air less sprey tools) complete all as specified .
Material & Labour for preparation of old decorated surfaces of walls including cornices, pilasters etc (Plastered or un plastered surfaces) and applying One Coat of cement base paint complete using air less sprey tools all as specified and as directed.
Resecuring or easing and adjusting wooden shutters of any description exceeding 1Sqm and not exceeding 2Sqm each with taking out and re-fixing in same opening complete all as specified and directed.
S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
M & L for Forming Construction joint 30mm deep x 10mm wide filled with sealing compound,Grade'A' all as specified and directed.
S&F for 8 feet 4 pipes pulley operated cloths drying system consisting of aluminium pipe of outer dia 22mm, inner dia 19.80mm, made up of detrin with rope guide mounted on channel pair of length 24 feet (distance between two pipes is adjustable) locking system to hide rope knot, channel to be mounted or fixed with self taping screws provided in kit. Rope will be HDPE double core of 4mm dia fixing to ceiling as specified and directed by Engr-in-Charge and minimum weight of one pipe shall not be less than 0.20kg/, minimum weight of rope shall not be less than 7700Gms/unit (for 04 pipes).
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point and all as specified and directed.
S &F 4mm thick frosted glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane and all as specified and directed.
Providing and injecting chemical emulsion using chlorpyriphos 20 percent EC with 1 percent concentartion for post constructional Anti-termite treatment along external wall below concrete or masonary apron using chemical emulsion at the rate of 2.25 literes per linear metre including drilling and plugging holes etc in apron complete all as specified and directed.
Providing and injecting chemical emulsion using chlorpyriphos 20 percent EC with 1 percent concentartion for post constructional Anti-termite treatment for treatment of soil under existing floors using emulsion at the rate of one litre per hole, 300mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1cement : 2 coarse sand) to match the existing floor complete all as specified and directed.
Providing and injecting chemical emulsion using chlorpyriphos 20 percent EC with 1 percent concentartion for post constructional Anti-termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) at the rate of 0.50 litre per hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed.
Making arrangement of scaffolding in buildings, cutting of small trees/plants at the stem, removal of the roots of the plants by using acids, cutting around the spot for removing the roots any size and making good with cement mortar 1:3 or with PCC 1:2:4 including finishing with existing complete all as directed by Enginner-in-charge.
Racking out joints / points in cement mortar to squared rubber masonry coursed or uncoursed all as specified and directed.
M&L for broken stone or boulders hardcore of gauge not exc. 63 mm , deposited, spread and levelled in layers n. exc. 100cm thick, watered and rammed to a true surface complete all as directed.
S&F chequered cement concrete tiles 30cmx30cmx25mm thick set jointed and pointed with grey cement and pigment to match the floor all as specified and directed.
Provn of Point wiring complete with 1. 5 Sq mm single Core PVC insulated FRLS cable, 1100 volts grade unsheathed with multi stranded copper conductor drawn through and including PVC rigid non metalic conduit / casing and capping with all fittings such as bend, end caps etc fixed on the surface of wall, ceiling, roof, steel structure etc. by means of suitable fixing accessories including provision of 1.5 Sq mm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor, fabricated steel terminal box made out of 1.6 mm thick MS sheet concealed in wall, with 3 mm thick laminated sheet top cover with brass screws and cup washers for housing the switches, sockets, regulators etc. all as specified and as directed complete for One light point controlled by one way switch. Note:- The rates are deemed to be included cutting chasing of any description of wall and making good the disturbed surface.
All as per item No. 143 here- in - before but for one exhaust fan point controlled by one way switch.
All as per item No. 143 here -in - before but for One 2/3 pin switch socket point controlled by 5 Amps switch on Independent board
Taking down carefully copper/aluminum point wiring (light, fan,Power) complete fittings such as switches , ceiling roses pendents , regulators sockets light fittings etc removing to store for keeping in safe costody or for taking credit and making good disturbed surface of wall, floors , roof etc all as specified.
M&L for Point wiring complete with 1. 5 Sq mm single Core PVC insulated FRLS cable, 1100 volts grade unsheathed with multi stranded copper conductor drawn through and including PVC rigid non metalic conduit / casing and capping with all fittings such as bend, end caps etc fixed on the surface of wall, ceiling, roof, steel structure etc. by means of suitable fixing accessories including provision of 1.5 Sq mm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor, fabricated steel terminal box made out of 1.6 mm thick MS sheet concealed in wall, with 3 mm thick laminated sheet top cover with brass screws and cup washers for housing the switches, sockets, regulators etc. all as specified and as directed complete for One light point controlled by one way switch. Note:- The rates are deemed to be included cutting chasing of any description of wall and making good the disturbed surface.
All as per item No. 147 here -in - before but for One light point controlled by two, two way switches.
All as per item No. 147 here -in - before but for One Ceiling fan/Exhaust fan point controlled by one one way switches.
All as per item No. 147 here -in - before but for One 3 pin switch socket outlet combination, 15 Amps, independent, with cables 2.5 sq mm but including taking down old wiring.
S&F switch piano, flush type, single pole, one way, 5 Amps, 240 V all as specified and as directed.
S&F switch piano, flush type, single pole, two way, 5 Amps, 240 V all as specified and as directed.
S&F Lamp holder, PVC / Polycarborate type with back plate suitable for battan fittings
Supply and fix switch socket combination, multipurpose 2 in 1 , 3 pin 5 Amps, flush typeuniversal all as specified and as directed.
Supply and fix switch socket combination, multipurpose 2 in 1 , 3 pin 5 Amps,/16 Amps flush type universal all as specified and as directed.
Supply and fix ceiling rose, surface bakelite type,PVC, 65 x 50 mm isolated body with three terminals all as specified and as directed.
Provision of Exhaust fan 300 mm sweep, 230/240 volt AC single phase, 1400 RPM,heavy duty including core cutting hole on stone masanery (Machine cutting) suitable for fixing exhaust fan with suitable nuts bolts and louers and make good the surface to match with existing surface complete.Make Bajaj, or equivalent approved make
Supply installation, testing and commissioning of Water heater storage type,capacity 25 litres.BEE 5 star rated, electically operated, single phase, 230V, 50Hz with vent pipe, fusible plug, thermostat, safety valve, proper earth connector, SS tank complete with all accessories required for plumbing work (inlet and out let GI pipe), grouting bolts and nuts etc, including inlet & outlet pipe connection(CP), one NRV, one bib tap and one stop cock complete all as specified and as directed by Engineer-in-Charge.
S&F LED Bulb 9W Make Bajaj or equivalent approved make
Provision of LED building security/street light fitting 20 watts made up of pressure diecast housing with toughened glass diffuser, with high power LEDs with option of secondary optic with IP66 protection, 110 LM/ watt and wired with accessories including suitable bracket & clamps with bolts & nuts all as specified and directed Make Crompton, or equivalent approved make. .
Supply and fixing in repairs 4 ft LED batten, wattage 20 w, having minimum lumen out put 1880 to 2000 with a system efficiency 100 lume/wattshort circuit and voltage cut of protection and wide operating voltage range - 140V to 270 V 6500 K colour temps, 50000 hrs life, IP 20 with all accessories internally Pre wired and including connecting up with 3 core twisted flexible copper conductor cable 0.75 sq mm from ceiling to fitting, mounted on roof/wall etc. on PVC round bush of suitable approved size as specified and as directed MAKE: BAJAJ or Equivalent approved make.
Supply and fixing in repairs 2 ft LED batten, wattage <10 w, having minimum lumen out put >900lm with with specially designed extructed thermal polycarbonate housing with high optically efficient serrated diffuse, isolated multistage CCCV driver with operating voltage range-140V to 270V temp range 0 to 50 deg C, driver efficiency >85%, power factor >0.95, THD<10% colour temp 6500 K, surge protection- 3KV in CM, safty extra low voltage safe leval<60V DC as per IEC strandard,IP 20 protection, life of 50000 hrs with luminaries efficiency > 100lm/W including connecting up with twisted flexible copper conductor cable 1.5 sq mm size from ceiling rose to connector fitting, mounted on roof/wall etc. on PVC round bush of suitable approved size all as specified and directed MAKE: BAJAJ or equivalent approved make.
S&F in repairs MCB DB SPN 8 WAY , horrizontal, double door, 240 V, AC,50 Hz, for MCB DP as incommer and and SP MCBs as out going.IP- 43 protection confirming to IS-13032, universal mounting with copper busbar, neutral link, earth link, earthing shuds detachable gland plates with knockouts on both sides all as specified and directed make Havells or equivalant approved make.
S&F in repairs MCB single pole and neutral 240 volts 40 Amps, 10 KA rupturing capacity. B series all as specified and as directed.
S&F in repairs MCB single pole 240 volts 5 to 30 Amps, 10 KA rupturing capacity.B series all as specified and as directed.
M&L for Earthing complete with galvanised steel earth plate electrode60×60cm.×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with GI protection pipe but all as specified and directed by Engineer-in-Charge. all as specified or indicated including testing on completion and taking down old earthing material.
C R R CONSTRUCTIONS
N RAJEGOWDA and CO
chowdeshwariconstructionco
M.S.Trading Company
S CHANDRASHEKAR (SREE BUILDERS)
Vinayaka Enterprises
D NAGI REDDY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .