Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹86.0 LAccepted-AOC C O GUPTA EMPORIUM AR BAZAR HAPPY VALLEY SHILLONG 793 004 | EAST KHASI HILLS | MEGHALAYA | 793004 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹89.2 L+₹2.7 L (3.17%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹90.2 L+₹3.7 L (4.31%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹91.0 L+₹4.5 L (5.17%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹91.6 L+₹5.1 L (5.89%)Rejected-Finance C O EROS PALA EAST LABAN ROAD SHILLONG 793004 | EAST KHASI HILLS | MEGHALAYA | 793004 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹77 L
EMD Value
₹1.4 L
Closing Date
6 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Shillong
HQ CWE Shillong, SE Falls, Shillong - 793011
SPL REPAIR FOR REPLACEMENT OF EXISTING CHLORINATION SYSTEM WITH V-100 HYDRO-DIS SYSTEM IN STN SWIMMING POOL AND CONNECTED WORKS IN NARANGI MIL STN UNDER GE NARANGI
2025_MES_703869_1
8867/NAR/E8
Open Tender
Water Equipments/ Meter/ Drilling/ Boring
Item Rate
180 days
Narangi
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE Narangi
₹1.4 L
Yes
6 Jun 2025
8 Apr 2025
8 May 2025
8 Apr 2025
6 May 2025
29 Apr 2025
Amount
Design, Supply, installation, testing & commissioning of V-100 Hydro-dis systems of required units suitable for Olympic size Stn swimming pool (minimum 04 units each flow rate 15 cum/hrs) based on dual step disinfection technique process that uses the electro-catalytic break down of water to instantly destroy water borne pathogens including bacteria, viruses and algae simultaneously converting chloride ions into chlorine, production/generate highly reactive Electrolytic Hydroxyl radicals which effectively neutralize pathogens and organic contaminants and remove any bad/foul smell/bacteria/virus odor or color from water to make it clean and safe for consumption and system designed to be energy efficient, allowing insolated and remote applications to utilize on site. Fixed in existing recirculation of water line in olympic size Stn swimming pool with continuous disinfection of water at a flow rate 60m³/Hrs including UPVC piping, fittings, valves, control panel complete. Note: The scope of work under above item shall also include following: 1. The complete system be installed and testing & commissioning by OEM and test report in duplicate be submitted to Engr-in-charge before completion. 2. The work include 08 years of warranty for Hydrodis modules & 02 years of warranty of all electromechanical components which includes complete periodical/preventive maintenance of the system to keep system fully functional . The work shall also include 02 years of AMC by OEM after completion of work certified by GE. The contractor shall quote rates accordingly and nothing extra shall be paid on this account. The contractor shall deposit two (02) fixed deposits corresponding to each year of AMC of above item. The amount of each fixed deposit shall be 1% of the quoted amount & each FS shall be released by GE after succesful completion of AMC for each year. If the contractor fails to complete AMC to entire satisfaction of GE, the corresponding fixed deposit shall be forfeited. 3. The job also includes electrical, mechanical, addn/alteration of existing pipe lines/system required for the job and make system fully functional further. 4. Any necessary statutory permission if required for installation/day to day operation for the subject work be taken to the competent authority by the contractor before starting the work and submitted to the Engr-in-charge. 5. The design shall be approved by GE before execution. If the design involves more than 04 units of V-100 Hydro-dis system no plus DO shall be admissible. 6. The contractor shall incorporate suitable clauses as per scope mentioned above in their MoU to be submitted during Cover-I. However in case of any default, the entire responsibility shall be of the contractor and contractor shall be considered liable for any default of OEM
Supply and fixing canopy for Hydrosis systems complete all as specified, directed and as shown on drawings. Notes : 1. The purlins and rafters shown in drawing shall be made of Mild Steel (Fy -250) Square section of size 50x50x3.65 mm including all fittings and fixtures complete as directed by Engr-in-Charge. 2. The outer wall shall be Half Brick thick Wall in CM 1:4 including chicken wire mess at alternate third layer. 3. The wall on one side of canopy shall also have provision of MS Door made up of MS sheet having thickness not less than 3mm with cross flat iron strip of size 25x5mm with Locking arrangement with MS sliding Door Bolt 300 mm Long including painting with two coats of synthetic enamel paints over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge. Internal Plaster - 10 mm thick 1:4 CM finished even and fair without using extra cement External Plaster - 15 mm thick in two layers (10+5)mm with using Water proofing compound @3% by weight of cement on top 5mm layer finished even and fair without using extra cement Internal and External Finishes - Three coats of white wash 4. The roof shall be of pre-painted Galvalume Corrugated sheets not less than 0.50mm thick and shall have projection not less than 300 mm on all sides. 5. Foundation shall be of PCC 1:4:8 type D-2 of thickness 150mm. The depth of foundation shall be 1.5m from NGL. 6. Flooring- The floor shall be 40 mm thick PCC 1:2:4 type B-1 finished fair and even without using extra cement laid over 75 mm thick PCC 1:3:6 type C-2 over rammed earth including filling to the required level, complete all as specified and directed.
Supply and fixing of PVC sheathed XLPE Insulated armoured aluminium cable of size 16 Sqmm 4 core, superior quality, laying over GI slotted cable tray including necessary supports and frame work complete all as specified and directed
Supply and fixing of Gl slotted cable tray 50mm high in 16 SWG 100 mm width including necessary supports and frame work complete all as specified and directed.
Material & Labour for earthing complete with copper earth plate electrode of size 60cm x 60cm x 3.15 mm buried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including copper strip of size 20x3 mm as earth lead upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40 mm bore Gl pipe connected to main control board and Gl pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mm C/C both ways with 10mm dia MS round bar as in lifting handles and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded stone aggregate) including excavation and earth work disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part I 2009.
Ms Amrik Singh Bahra (BID ID -3292015)
M/s Sohini Construction (BID ID -3292469)
Bharara construction (BID ID -3292339)
S K Construction (BID ID -3292597)
M/s Gupta Construction (BID ID -3292236)
PURBANCHAL BUILDERS (BID ID -3292497)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .