Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.0 LAccepted-AOC | 1 | Accepted-AOC Lowest Bid | |
| 2 | 2₹19.9 L+₹1.9 L (10.7%)Rejected-Finance C 134 GALI NO 08 NORTH GHONDEA DELHI PIN 110053 | NORTH EAST | DELHI | 110053 | 2 | Rejected-Finance Highest Bid |
Tender Value
₹25.4 L
EMD Value
₹51,000
Closing Date
4 Jan 2024, 4:00 pmClosed
Commandant Engr J and K Zone CRPF jammu
Office of SDG J and K Zone CRPF Jammu
Repairing maintenance of Fire fighting and fire alarm system at GC CRPF Gurugram HR
2023_CRPF_787038_1
B.V-8/2023-24-JKZ -C-CELL-GC GGM6
Open Tender
Civil Works - Others
Works
75 days
DIG GC CRPF Kadarpur Gurugram HR
As per NIT
2 documents required · 2 mandatory
₹0
₹51,000
24 Feb 2024
23 Dec 2023
5 Jan 2024
23 Dec 2023
4 Jan 2024
23 Dec 2023
23 Dec 2023 - 4 Jan 2024
Dismantling of existing main pump model no.DSM 100/36 Kirlosker make from house and send to workshop and replaced new accessories in place of defective accessories & fixing alignment the same place complete with testing and commissioning etc. as reqd.
Dismantling of existing Jockey pump Kirlosker make from house and send to workshop and replaced new accessories in place of defective accessories & fixing alignment the same place complete with testing and commissioning etc. as reqd.
Dismantling of existing Diesel Engine pump model no. 4R1040-T Kirlosker make from Site and send to workshop and replaced new accessories in place of defective accessories & fixing alignment the same place complete with testing and commissioning with mobil oil, 100 Ltr Diesel and filters of engine etc. as reqd.
Supplying & Fixing of Following Size PN.1.6 rising spindle sluice valve ISI marked CI body Stainless steel shaft i/c rubber packing nut and bolts after dismantling of defected & unserviceable sluice valve complete testing as required. (Make Kirloskar/Kalpana/ Kartar) 150 mm
Supplying & Fixing of Following Size PN.1.6 rising spindle sluice valve ISI marked CI body Stainless steel shaft i/c rubber packing nut and bolts after dismantling of defected & unserviceable sluice valve complete testing as required. (Make Kirloskar/Kalpana/ Kartar) 100 mm
Supplying & Fixing of Following Size PN.1.6 rising spindle sluice valve ISI marked CI body Stainless steel shaft i/c rubber packing nut and bolts after dismantling of defected & unserviceable sluice valve complete testing as required. (Make Kirloskar/Kalpana/ Kartar) 80 mm
Dismantling & servicing , repairing / Replacement of defective Suice Valve of following size complete with rubber packing , greacing & fixing in the existing position with nut and bolts etc. as required. 150 mm
Dismantling & servicing , repairing / Replacement of defective Suice Valve of following size complete with rubber packing , greacing & fixing in the existing position with nut and bolts etc. as required. 100 mm
Dismantling & servicing , repairing / Replacement of defective Suice Valve of following size complete with rubber packing , greacing & fixing in the existing position with nut and bolts etc. as required. 80 mm
Supplying & Fixing of following size PN 1.6 non return valve as CI body i/c rubber packing nut & bolts after dismantling of defective & unserviceable non return valve complete testing commissioning etc. as required. (make Kirloskar / Kalpana / Kartar) 150 mm
Supplying & Fixing of following size PN 1.6 non return valve as CI body i/c rubber packing nut & bolts after dismantling of defective & unserviceable non return valve complete testing commissioning etc. as required. (make Kirloskar / Kalpana / Kartar) 100 mm
Supplying & Fixing of following size PN 1.6 non return valve as CI body i/c rubber packing nut & bolts after dismantling of defective & unserviceable non return valve complete testing commissioning etc. as required. (make Kirloskar / Kalpana / Kartar) 80 mm
Dismantling & servicing , repairing / Replacement of defective NON Return Valve of following size complete with rubber packing , greacing & fixing in the existing position with nut and bolts etc. as require 150 mm
Dismantling & servicing , repairing / Replacement of defective NON Return Valve of following size complete with rubber packing , greacing & fixing in the existing position with nut and bolts etc. as require 100 mm
Dismantling & servicing , repairing / Replacement of defective NON Return Valve of following size complete with rubber packing , greacing & fixing in the existing position with nut and bolts etc. as require 80 mm
Supplying & Fixing of first aid hose reel wall mounting wall swinging type fitted with 30 mtr long 20 mm high pressure hose confirming to IS:1532 with 6 mm dia outlet GM shut of nozzle and shut of valve and 20 mm dia outlet GM inlet gate valve as per IS:884 finished with postal red paint etc. complete as required. (Make:-Getech / Lifeguard / Safeguard)
Dismantling of existing hose reel drum & repairing /Replacement of defective spare parts with 1 No. union or 1 No. 25 mm ball valve & 20mm dia 63 mtr long type 2 thermo plastic pipe in the existing drum with two nos clamp & 1 Nos shut of nozzle complete the same as required.
Supplying & Fixing of SS metal ISI Mark fire hydrant Single landing valve with 80 mm NB flanged inlet, brass spindle controlled 63 mm dia female instaneous outlet type SS coupling blank cap, chain, twist release type lugs & all accessories Confirming to IS:5290. Including testing commissioning etc. as required. (Make Getech / Lifeguard / Safeguard)
Dismantling of Single landing valve ( Hydrant ) and repairing/ replacement of defective parts and rubber packing complete with nut bolts & fixing the same as required.
Supplying & fixing of GM/SS female coupling ( Adapter) in the existing landing valve where is mis place complete as required.
Dismantling of FBC and repairing/ replacement of defective parts and rubber packing complete with nut bolts & fixing the same as required.
Providing and fixing 63 mm dia 15 mtr. long rubberized fabric lined hose including SS male & female instantaneous type coupling approved by fire authority, machined wound with SS wire complete in all respect, hose shall conform to IS : 636 TYPE „B‟ and coupling to IS 903-1990 with ISI certificate (Make:-Getech/Safefire/Safeguard).
Supply & Installation of 63 mm dia instantaneous pattern SS metal branch short pipe , 20 mm di nozzle confirming to IS 903, suitable for inter connection to hose pipe coupling complete as required. (Make:-Getech/ Lifeguard/Safeguard)
Supplying and fixing of hydrant box made out of 1.2mm thick MS sheet of size 900mm x 600mm x 500mm 16 gauge to accommodate two no‟s hose pipe and branch pipe double door with locking arrangement and 4mm acrylic sheet on front with writing “Break Glass in case of fire”. Complete with complete as required. (Make:- Getech/Lifegaurd/Safeguard)
Supplying / Fixing of following accessories complete testing , commossioning etc as required Pressure guage
Supplying / Fixing of following accessories complete testing , commossioning etc as required Pressure Switch
Supplying / Fixing of following accessories complete testing , commossioning etc as required 25mm Air release Valve
Supplying / Fixing of following accessories complete testing , commossioning etc as required 25mm Ball Valve
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paint of required shade complete as required (Make:- Jindal/ Tata 150 MM
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paint of required shade complete as required (Make:- Jindal/ Tata 100 MM
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (Make:- Jindal/ Tata 150 mm
Cutting of RCC for fixing of 150mm pipe 450mmX100mm deep and repairing and making by RCC and finished with plaster complete as required.
Supplying and fixing of 12Volt following Capacity SMF battery Exide Make with four no. battery terminal and battery terminal lead complete with testing commissioning etc as reqd 180 AH
Supplying and fixing of 12Volt following Capacity SMF battery Exide Make with four no. battery terminal and battery terminal lead complete with testing commissioning etc as reqd 60 AH
Supplying and fixing of Manufacturing of spare parts in the existing electrical panel of fire fighting system :- Power Contactor 25 Amp ML 1.5
Supplying and fixing of Manufacturing of spare parts in the existing electrical panel of fire fighting system :- Power Contactor 110 Amp ML 6
Supplying and fixing of Manufacturing of spare parts in the existing electrical panel of fire fighting system :- Control Relay
Supplying and fixing of Manufacturing of spare parts in the existing electrical panel of fire fighting system :- Timer 12-120 Secs
Supplying and fixing of Manufacturing of spare parts in the existing electrical panel of fire fighting system :- Single Phase Preventor
Supplying and fixing of Manufacturing of spare parts in the existing electrical panel of fire fighting system :- LED Indicator Light Red/Yellow/Blue/Green
Supplying & fixing of 4 mm Acrylic Sheet for in the existing hydrant Box complete as required
Rectification of faults of 2 Loop addressable Bosch make fire alarm panel by locating the type of faults from Resiential Block & Barrack in all rooms wherever required including faulty detectors, faulty cable lines and associated accessories complete wherever required below & above false ceiling and setting right all the faults by necessary repairing/ replacement of parts & tapping/tightening of connection cables including reprogramming/ recommissioning of the panel by Boch software etc. complete as required Bosch Panel
Rectification of faults of 2 Loop addressable Bosch make fire alarm panel by locating the type of faults from Resiential Block & Barrack in all rooms wherever required including faulty detectors, faulty cable lines and associated accessories complete wherever required below & above false ceiling and setting right all the faults by necessary repairing/ replacement of parts & tapping/tightening of connection cables including reprogramming/ recommissioning of the panel by Boch software etc. complete as required Agni Panel
Checking, Repairing existing unlock macroprocessor based existing fire alarm panel complete with testing only main panel as required.
Checking, Repairing existing unlock macroprocessor based existing fire alarm panel complete with testing only Zonal Floor panel as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning of manual call boxes of MS construction insurface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
AZIM ALI SHAH
AZIM ALI SHAH
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .