Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹26.0 L+₹2.6 L (11.2%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹26.4 L+₹3.0 L (13.0%)Rejected-Finance 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L3 | Rejected-Finance BEING L3 |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
25 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF THANE
Kolshet Road, Sandoz Baugh Post, Thane 400607
UPGARDATION OF MGR AND SUB GUARD ROOM AND ALLIED WORKS AT STN MADH ISLAND UNDER GE(AF)THANE
2022_MES_538709_1
8185/E8
Open Tender
Civil Works
Item Rate
330 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹72,000
Yes
21 Sept 2022
26 Jul 2022
26 Aug 2022
26 Jul 2022
25 Aug 2022
12 Aug 2022
26 Jul 2022 - 12 Aug 2022
Amount
Taking down cement plaster on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work built in cement mortar including all quoins, arches, pilllars etc. and precast articles including disposal of demolished material complete all as specified and directed.
Demolition of reinforced cement Concrete in Roofs, floors (other than ground floors), beams,staircases, landing, chajjas, and similar suspended work ,complete all as specified and directed by Engr-in-charge.
M &L Brickwork with sub-class `B' brick straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Material and labour for reinforced cement concrete Type B0 1:2:4 (using 12.5mm graded stone aggregate) etc as in chajjas including necessary form work complete all as specified and as directed
M & L for Pre-cast cement concrete block masonry type C1 (using 20mm graded stone aggregate) set in cement mortar 1:6 with solid blocks, exc. 10 cm in width and setting in mortar, complete complete all as specified and as directed.
M&L for rendering 15mm thick in cm 1:6 finished with neeru finish as specified on fair faces of brick work /stone or concrete surfaces complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 20 mm thick (15 mm thick in CM 1:6 as backing coat and 5mm thick in CM 1:4 as finishing coat) on fair faces of brick work or concrete surfaces including finished even and smooth without using extra cement with using water proofing compound (water proofing compound shall be measured and paid seperately) complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm thick in cm 1:3 on fair faces of concrete as in soffit/ ceilling or slab, chajjas finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified and directed by Engineer-in-Charge.
M&L for applying two coats of acrylic water/weather proof exterior emulsion coating over one coat of primer all as per manufactures instructions including preparation of new surfaces of wall/ complete all as specified and directed by Engineer-in-Charge.
M&L for preparing newly plastered surfaces and applying 2 coats of Oil Bound Distemper over a coat of alkali resistent primer Over 1 mm thick wall care putty on walls, complete all as specified and directed by Engineer-in-Charge.
M&L for Complete removal of existing treatment on old surface of walls and applying 2 coats of Oil Bound Distemper over a coat of alkali resistant primer , complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of old surfaces of ceiling and applying two coats of oil bound distemper , complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of newly surfaces of ceiling and applying three coat of white wash complete all as specified and directed by Engineer-in-Charge.
Removing existing water proofing treatment what so ever exist (except concert padding) and removing debris/ rubbish materials off the site complete all as specified and directed by Engr-in-Charge.
M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust & brushing neat cement slurry with 3 Kgs of cement per sqm etc all as specified and directed by Engr-in-Charge.
M&L for Plain cement concrete (PCC) padding in cement concrete (1:2:4) type B0 (using 12.5 mm graded stone aggregate) finished even and smooth without using extra cement , complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick screed bed or bedding layer in cement mortar 1:4 over RCC Slab horizontal or vertical portion for laying water proofing treatment all as specified & directed by Engr-in-Charge.
M&L for APP modified roof treatment over existing RCC roof with following specification :-(a) Applying bitumen primer @ 0.4 Liters/Sqm with density of 0.87 to 0.89 Kg/Liters at 25 degree C on the prepared dry roof surface. (b) Laying 3 mm thick APP membrane weight not less than 3.50 Kg/Sqm by torch application with minimum 10cm side lap and 15cm end lap. The laying of membrane shall be done through an authorised applicator of manufacturer of APP membrane. (c) Over the membrane provide a solar reflective bituminous aluminium paint @ 0.1 Kg/Sqm prescribed by manufacturer complete all as specified and directed by Engineer-in-Charge.
Removal of existing concrete including loose/weak concrete from the concrete structure i.e. beams/columns/deckslab etc upto beyond corroded steel reinforcements to a depth of minimum 10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting and removal of debris. Concrete around the corroded reinforcement shall be removed properly. The edges of the repair locations of concrete should be saw cut to depth of at least 10mm to avoid featheredging and to provide a square edge complete all as specified and directed by Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for Preparation of surface and removal of rust in the loosely bonded concrete of the RCC deckslab, beam / girder and piles shall be chipped out using the mechanical cutter exposing the bars and applying Rust Remover using small brush and allow to react it for 16- 24 hrs. Before applying protective coating,the surface should be wire brushed and thoroughly cleaned for dust with dry cloth complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for applying two coats of Anti-Corrosive Primer two component (epoxy anti-corrosive zinc rich coating) on reinforcement steel surfaces uniformely. Coating shall be applied by the brush to the exposed and cleaned rebars with an interval of 45 minutes to 1 hour @ 40microns DFT / coat and allowed to completely dry for 24 hours complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for preparation of concrete surfaces by removing loose concrete, dust, dirt etc, cleaning the surface properly and applying one liberal coat of epoxy bonding agent ( two component agent) by brush application complete all as per manufacturer instruction and directed by Engr-in- Charge Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for Providing & executing injection/pressure grouting in the cracks in the parent concrete by fixing PVC/Aluminium nipples at 150mm to 200mm distance or specified distances as per design and detailed specifications. Pressure grouting using low viscous epoxy grout. Moisture insensitive epoxy resin injection material supplied in 1.5 Litre pack which can grout gaps ranging from 0.25mm to 9mm, having mix density 1060 Kg/m3, compressive strength 60 N/mm2, Tensile Strength 20 N/mm2, Flutural strength 45 N/mm2. Pressure grouting shall be carried out after surface preperations includes fixing nipples and filling cracks with epoxy mortar one day before grouting, injecting low viscous grout mechanically about pressure 3.5-7.0 Kg/Cm2, removing nipple after grouting and sealing with epoxy mortar etc complete as directed by Engr - in - Charge. Payment shall be made on actual grout consumed. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for Cutting, fabricating new reinforcement Fe500 and fixing with old existing reinforcement which was reduced to 20% or more of its original diameter as provided in original structure and additional steels as directed by EIC to be fixed with chemical anchor grout Lokfix E55 (Styrene free vinyl-ester resin based catridge system for anchoring reinforcement supplied in 300 ml catridge with a single mixer nozzle of Fosroc or equivalent approved make, application includes drilling hole close to old reinforcement bar with suitable drill as per dia of bar, cleaning the hole with wire brush and compressed air, putting Lokfix E55 or equivalent with gun followed by placing rebar with slide rotational motion to avoid air void formation etc complete all as per manufacturer instructions and as directed by the Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for Drilling holes into existing concrete substrate for anchoring of new rebars nwith 10mm dia shear connectors at 0.5 mtr c/c and fixed with chemical anchor Lokfix E55 or equivalent - Styrene free vinyl-ester resin based catridge system for anchoring reinforcement supplied in 300 ml catridge with a single mixer nozzle, shall be tested in accordance European approval to EAD-33087-00-0601 for use in post-installed rebar, which supersedes ETAG 001 TR 023 (rebar), LEED compliant VOC Level, Fire resistance<120mins, Seismic C1 testing as part of EAD 330499-00-0601 for specific fastening sizes etc. Typical applications includes drilling hole 14mm dia and 90mm deep as per manufacturers recommendation, cleaning the hole with wire brush and compressed air, putting Lokfix E55 with gun followed by placing shear connector with slide rotational motion to avoid air void formation etc complete as directed by EIC. HSE Guidelines : Recommended to wear tight fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for 50mm thick ( average thickness) modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar on conrete structure including applying the mortar around the reinforcement and finishing to bring it in line with existing concrete surface complete all as per manufacturer instructions and directed by the Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for micro concrete to existing concrete structure including proper tight leak proof shuttering SPL polimer modified cementitious ,low permeable'free flow 'non shrink 'self compacting micro concrete shall be grade M70 as per recommended w/c ratio and pouring as per the required thickness complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed by Engineer-in-Charge.
M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-Charge.
Dismantling floor,hearth or wall tiling including cement morter bedding (but not backing) and rubbish off the premies ,complete all as specified and as directed by Engineer-in-Charge.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed by Engr-in-Charge.
M & L for cement concrete 50mm thick, type B-2, 1:2:4 (using 40 mm graded stone aggregate) as in sub base for flooring ,complete all as specified and directed by Engr-in-Charge.
M&L for Vitrified tiles 600x600x10mm thick polished, in floors etc set and jointed in neat cement slurry and pointed in white or coloured to match over & including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for Coloured Glazed Ceramic tiles 200x300x 6-7mm thick on vertical surfaces such as skirting, dados and risers to steps etc including 10mm thick backing coat in CM 1:4 complete all as specified and directed by Engineer-in-Charge..
M&L non skid ceramic tiles(Coloured) 7 to 8mm thick (square/rectangular) area of each tile exc 0.06sqm but n.exc 0.11 sqm, in in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including screed bed 15mm thick in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
Taking up or down 20 mm dia bore steel tubing and connections, including cleaning for re- fixing or removal to store, complete all as specified and as directed by Engineer-in-Charge.
Taking up or down 15 mm dia bore steel tubing and connections, including cleaning for re- fixing or removal to store, complete all as specified and as directed by Engineer-in-Charge.
Refixing old steel tubing and connections in new or old positions of 15mm bore , complete all as specified and as directed by Engineer-in-Charge.
Refixing old steel tubing and connections in new or old positions of 20mm bore , complete all as specified and as directed by Engineer-in-Charge.
S&F GI tubing 20mm dia bore ,medium grade including all fittings fixed in floor /walls/ ceilling etc , complete all as specified and as directed by Engineer-in-Charge.
S&F GI tubing 15mm dia bore,medium grade including all fittings fixed in floor /walls / ceilling etc , complete all as specified and as directed by Engineer-in-Charge.
S&F ,in repair, stop valves for 15mm bore dia ,cast copper alloy, screwed down, high pressure with butterfly handle, screwed both ends for iron pipe or for unions ,complete all as specified and as directed by Engineer-in-Charge.
S&F,in repair, bib taps for 15mm bore dia, fancy type cast copper alloy chromium plated with butterfly handle, screwed down, screwed for iron pipe or for brass ferrule ,complete all as specified and as directed by Engineer-in-Charge.
S&F PVC connection for 15mm dia pipe and 60cm long with brass socket on both side ,complete all as specified and as directed by Engineer-in-Charge.
S&F,in repairs, PVC low level flushing cistern of 10.0 ltrs capacity with complete fitting including float valve flush pipe bracket for flush ,complete all as specified and as directed by Engineer-in-Charge.
S&, in repairs, gratings square 150 mm size of PTMT (min wt 100 gm) ,complete all as specified and as directed by Engineer-in-Charge.
S&F,in repairs, aluminium powder coated decorative draphery rod 20 to 25mm dia ,complete all as specified and as directed by Engineer-in-Charge.
S&F,in repairs, aluminium powder coated brackets suitable for decarative draphery rods 20 to 25mm dia ,complete all as specified and as directed by Engineer-in-Charge.
S&F wash down water closet (pedestal pattern/white fixed in repairs Excluding flushing cistern & flushing pipe) complete with & including connecting to drain pipe etc ,complete all as specified and as directed by Engineer-in-Charge.
S&F,in repairs, brass ball valve for 20 mm bore dia. high pressure, with ploythene float and flynut complete, screwed for iron pipe or brass ferrule ,complete all as specified and as directed by Engineer-in-Charge.
Dismantling water tanks capacity 1000 ltr including all fittings and removing to store ,complete all as specified and as directed by Engineer-in-Charge.
S&F, in repairs, Gun metal Gate valve for 20mm bore dia ,screwed both ends for iron pipe & fixed ,complete all as specified and as directed by Engineer-in-Charge.
S&F,in repairs, Rotational moulded polyethylene water storage tanks ,triple layered (cylindrical vertical with closed top) of 1000 litre capacity hoisted and fixed in position ,complete all as specified and as directed by Engineer-in-Charge.
S&F,in repairs,PTMT health faucet suitable for 15mm bore pipes ,including long pvc connection including bracket other fitting for fixing ,complete all as specified and as directed by Engineer-in-Charge.
S&F, in repairs, PTMT Angle stop valve for 15 mm bore dia of any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms) ,complete all as specified and as directed by Engineer-in-Charge.
Dismantling Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings ,complete all as specified and as directed by Engineer-in-Charge.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates ,complete all as specified and as directed by Engineer-in-Charge.
S&F mild steel confirming to FE-290(Gde-E-165),(Flat sections) as in wind ties and similar work including cutting to required length nothing ,drilling,fitting , connecting with nuts bolts and fixed in true position complete all as specified and as directed by the Engineer in charge.
S & F Plates( Plain or chequered ) of Fe-410-W (Gde-E-250) Quality -B channels,square cut or notched (ordinary and counter sunk) forming holes, without any attachment ,complete all as specified and as directed by Engineer-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws ,complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of new surfaces of steel of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide ,complete all as specified and as directed by Engineer-in-Charge.
S&F extruded aluminium alloy handles of 150mm size fabricated type anodized ,complete all as specified and as directed by Engineer-in-Charge.
S&F Aluminium mortice lock, vertical type, size 100mm, 4 levers ,complete all as specified and as directed by Engineer-in-Charge.
S&F Double action floor spring hydraulically operated made up of miniumum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass other parts made of mild steel heavy duty ,complete all as specified and as directed by Engineer-in-Charge.
S&F Aluminium handle 150mm long, cast type, anodised ,complete all as specified and as directed by Engineer-in-Charge.
S&F Aluminium handle 100mm long , cast type, anodised ,complete all as specified and as directed by Engineer-in-Charge.
S& F Butt hinge 100mm long , extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 ,complete all as specified and as directed by Engineer-in-Charge.
S&F Aluminium alloy, anodised, sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed ,complete all as specified and as directed by Engineer-in-Charge.
S&F Aluminium anodised, barrel tower bolts 150mm long of ex-truded section and fixed ,complete all as specified and as directed by Engineer-in-Charge.
S&F Aluminium anodised, barrel tower bolts 100mm long of ex- truded section and fixed ,complete all as specified and as directed by Engineer-in-Charge.
Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each with shutters (without taking off shutters from the frame) and removing from site ,complete all as specified and as directed by Engineer-in-Charge.
Taking down Shutters and refixing in same position including all necessary fitting exc 1 sq. m and n exc 2 sq. m each ,complete all as specified and as directed by Engineer-in-Charge.
S&F ,in repairs, Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples ,complete all as specified and as directed by Engineer-in-Charge.
S&F ,in repair, Solid PVC Door Frame of size 50mm x 47mm made up of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as specified in SSR Part-I ,complete all as specified and as directed by Engineer-in-Charge.
S&F,in repair,Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats ,complete all as specified and as directed by Engineer-in-Charge.
S& F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing as specified in SSR Part-I ,complete all as specified and directed by Engr-in-Charge.
S&F powder coating (powder coating thickness minimum 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. ,complete all as specified and directed by Engr-in-Charge.
S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. ,complete all as specified and directed by Engr-in-Charge.
Supply & fix Rubber beeding suitable for aluminium door/window shutters ,complete all as specified and directed by Engr-in-Charge.
Supply & fix ordinary sheet glass 4.8mm thick in square exc 0.5sqm in each panes ,complete all as specified and directed by Engr-in-Charge.
M&L for Waste fittings of 32mm dia , brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed ,complete all as specified and directed by Engr-in-Charge.
S&F in repair Grating round 140 mm size of PTMT. (Minimum weight 50gms) ,complete all as specified and directed by Engr-in-Charge.
S&F in Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) ,complete all as specified and directed by Engr-in-Charge.
S&F Shower arm 15 mm size, 195mm long with bend of 45 degree with flange of PTMT any colour.(Minimum weight 40gms) ,complete all as specified and directed by Engr-in-Charge.
S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) ,complete all as specified and directed by Engr-in-Charge.
S&F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) ,complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) pipes of 110mm bore ,single socketed, in any length with rubber ring joints, laid in trenches or in floors ,complete all as specified and directed by Engr-in-Charge.
S&F in repair Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100mm bore dia ,complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) bends of 110mm bore any radius ,complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) 'S' trap of 110mm bore ,complete all as specified and directed by Engr-in-Charge.
S&F in repair110mm PVC (SWR) WC connector bent type ,complete all as specified and directed by Engr-in-Charge.
S&F in repair Cast iron floor trap of 75mm dia of outlet ,with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) ,complete all as specified and directed by Engr-in-Charge.
S&F in repair Cast iron nahani trap of 75mm dia of outlet with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) ,complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) gully trap of 125/110 mm dia , setting and jointing with solvent cement ,complete all as specified and directed by Engr-in-Charge.
S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) ,complete all as specified and directed by Engr-in-Charge.
Taking down carefully point wiring and removing from site such as (Light,fan socket or power) Complete including fitting and fixtures,fan regulators switch boards,switches,ceiling rose's lamp holder from existing batten PVC conduit/steel conduit wiring complete excluding light fittings and fans all as specified and making good to the disturbed surfaces to match with existing all as specified and directed by Engr- in - Charge.
Taking down main Switches,MCB DB with MCBs ,complete all as specified and directed by Engr-in-Charge.
Taking down Sub main wiring of any sizes in PVC casing caping/conduit ,complete all as specified and directed by Engr-in-Charge.
M & L for point wiring with PVC insuleted unsheathed 1100 Volts grade single core multistranded Copper conductor cable 1.5 Sqmm drawn and including PVC casing caping conduit and accessories etc with necessary fixing accessories and earth continuity conductor cable of size 15 Sqmm green colour Connected to common earth and including pressed steel terminal boxes concealed in wall Covered with laminated hylum sheet top cover 3mm thick for mounting switches/ sockets/ fan regulators fixed with cadmium plated machine screws all as specified and directed for the following :-
One light / fan/Exhaust Fan point controlled by one way switch.
One socket outlet 5 Amps on independent board.
One socket outlet 5 Amps on the same board
All as per Srl item No 103.00 herein before but with 2.5 Sqmm for phase & neutral and 1.5 sqmm for earth wire for socket out let 15 Amps.
S&F ceiling rose surface type bakelite 65x50mm three terminal ,complete all as specified and directed by Engr-in-Charge.
S&F switch piano flush type, 6 amps, 230V AC, single pole, one way ,complete all as specified and directed by Engr-in-Charge.
S&F switch piano flush type 16 amps, 230V AC single pole one way ,complete all as specified and directed by Engr-in-Charge.
S&F socket out let multipurpose suitable for 2 pin and 3 pin 6 amp flush type ,complete all as specified and directed by Engr-in-Charge.
S&F socket out let multipurpose type, for 3 pin 6 and 16 amp flush type ,complete all as specified and directed by Engr-in-Charge.
Supply & fix in repair fan step regulator, electronic type, single phase, 240 Volts incl connection ,complete all as specified and directed by Engr-in-Charge.
S&F in repairs MCB DB SPN 8 Way with 200 amps rated bus bar, Double door type 240 Volts ,complete all as specified and directed by Engr-in-Charge.
S&F in repairs MCB DB TPN 12 Way Double door type 240 Volts ,complete all as specified and directed by Engr-in-Charge.
S&F in repairs MCB DB SPN 4 Way with 200 amps rated bus bar, Double door type 240 Volts ,complete all as specified and directed by Engr-in-Charge.
S&F in repairs MCB DB TPN 4 Way double door type 415 V with bus bar ,complete all as specified and directed by Engr-in-Charge.
S&F in repairs MCB TPN 63 Amps 415 Volts ,complete all as specified and directed by Engr-in-Charge.
S&F in repairs MCB SP 06 to 32 Amps 240 Volts ,complete all as specified and directed by Engr-in-Charge.
S&F in repairs MCB SPN 06 to 32 Amps 240 Volts ,complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs Isolator SPN 40 Amps ,240 Volts ,complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs Isolator TPN 63 Amps, 415 Volts ,complete all as specified and directed by Engr-in-Charge.
M&L for Sub Main wiring with two single core 2.5 Sqmm PVC insulated FR multistranded flexible copper conductor cable 660/1100 volts grade drawn in through flexible non metallic PVC Concealed conduit with and including PVC insulated 1.5 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly ,complete all as specified and directed by Engr-in-Charge.
M&L for Sub Main wiring with two single core 4 Sqmm PVC insulated FR multistranded flexible copper conductor cable 660/1100 volts grade drawn in through flexible non metallic PVC casing caping conduit with and including PVC insulated 2.5 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly ,complete all as specified and directed by Engr-in-Charge.
M&L for Sub Main wiring with two single core 6 Sqmm PVC insulated FR multistranded flexible copper conductor cable 660/1100 volts grade drawn in through flexible non metallic PVC concealed conduit with and including PVC insulated 4 Sqmm single core single strand copper conductor as continuous earth wire green in colour connected to common earth dolly ,complete all as specified and directed by Engr-in-Charge.
S&F in replacement SP MCB 20 Amp 240 Volts of single pole and neutral enclouser with a two pin and earth plug and metal clad plug socket ,complete all as specified and directed by Engr-in-Charge.
S&F energy efficient light emmitting LED light fitting aluminium body 1 x 18 watt, four feet , white fittings with LED rod complete with all accessories & Provn of three core cable of copper conductor of size 0.75 sqmm, making necessary electric connetion from ceiling rose to fitting terminal, fixing the fitting on wall including all necessary fixing accessories ,complete all as specified and directed by Engr-in-Charge.Make- Cat No :LTTB4F20WLED/W (20W- 4FT WHITE) of C&S or equivalent Make: Wipro/Philip/Bajaj/Havells.
Material and labour for taking down the out door unit of split AC any capacity from the existing position and preparing of old painted surfaces of the following appliancs except cooling coil cleaning and applying two coats of synthetic enamelled paint of approved colour by spray gun machanically and fixing at the same postition including necessary changing of refrigerant and coper pipe to function the AC,complete all as specified and directed by Engr- in-Charge
Taking down Air Termination Rod from existing place to function the AC ,complete all as specified and directed by Engr- in-Charge
Refixing the Old Air Termination Rod at the existing position ,complete all as specified and directed by Engr- in-Charge (Note: Old Serviceable rod retrived from relevent item of Sch A shall be used against this item)
S&F for Air termination rod single pointed copper rod 12mm dia and 1000mm long with nuts, bolts, washers and clamps for holding the rod ,complete all as specified and directed by Engr- in-Charge.
Taking down old serviceable/unserciveable copper strip from roof including saddles and screw from roof conductor and down conductor and making good to the disturbed surface ,complete all as specified and directed by Engr- in-Charge .
Refixing the old serviceable copper strip, ,complete all as specified and directed by Engr- in-Charge. (Note: Old Serviceable copper strip retrived from relevent item of Sch A shall be used against this item)
S&F Copper Strip of 20 x 3.15 mm Size with saddles and fixing screws etc for roof conductors and down conductors above ground on Porceline insulator suitable for running the strip of above size ,complete all as specified and directed by Engr- in-Charge
Supply and fix ,in repair, galvanised iron tubing medium grade 50 mm bore laid in trenches / floors for passing through copper strip ,complete all as specified and directed by Engr- in-Charge
S&F Porcelain cleat/insulator of suitable size 50 X 65 mm for fixing copper strip of lighting arrestor conductors ,complete all as specified and directed by Engr- in-Charge.
S&F for test point terminal block made of gun metal or phosphorus bronze size 75mm x75mm x 25mm drilled and screwed including 3 Nos 8mm dia and 25 mm long hexagonal Head screws,complete all as specified and directed by Engr- in-Charge.
M&L for PCC (1:2:4) type B1 using 20 mm graded aggregate to made PCC precast block of size 200x100x90 mm to fix on the top of roof with the help of cement mortar/fixing material for fixing of porcelain insulator etc complete all as specified and directed by Engr-in-Charge.
M&L for Cutting the existing road/hard standing surfaces to a depth of 60 cm and 0.45 cm width and getting out for laying of GI pipe for copper strip protection including removing/returning filling with top 15cm thick with PCC 1:2:4 type B1 using 20mm graded stone aggregate and finishing even and fair without using extra cement including disposal of surplus soil all as directed by Engr-in-Charge.
M & L for point wiring with PVC insulated unsheathed 1100 Volts grade single core multistranded Copper conductor cable FRLS 1.5 Sqmm drawn in and including steel enamelised conduit and with all accessories, fixed on wall/ ceiling etc with necessary fixing accessories and earth continuity conductor cable of size 1.5 Sqmm green colour Connected to common earth dolly including pressed steel terminal boxes concealed in wall Covered with laminated sheet top cover 3mm thick for mounting switches/ sockets/ fan regulators fixed with cadmium plated machine screws all as specified for the following: (a) One light / fan point controlled by one way switch
Taking down flame proof light from existing position and refixing the same in position including all necessary accessories after preparation /plastered surface ,complete all as specified and directed by Engr -in- Charge.
S&F switch flame proof rotary type with termination box in LM6, 16A Single Pole 250V including all necessary fixing accessories ,complete all as specified and directed by Engr -in- Charge.
S&F exhaust fan,steel body AC single phase, 230 V of size 300 mm sweep with blades, frame and louvers and Nut bolt etc ,complete all as specified and directed by Engr- in-Charge
CROSSLINE ENGINEERS AND CONTRACTORS
M/s Mukesh Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .