Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAdmitted-Finance 127 102 JUHI KANPUR | KANPUR | KANPUR | UTTAR PRADESH | ₹39.7 L | L1 | Admitted-Finance |
| 2 | L2₹44.9 L+₹5.2 L (13.1%)Admitted-Finance | ₹44.9 L+₹5.2 L (13.1%) | L2 | Admitted-Finance |
| 3 | L3₹47.2 L+₹7.5 L (18.9%)Admitted-Finance | ₹47.2 L+₹7.5 L (18.9%) | L3 | Admitted-Finance |
| 4 | L4₹50.0 L+₹10.3 L (26.1%)Admitted-Finance | ₹50.0 L+₹10.3 L (26.1%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | VIBHU ENTERPRISES L1 | M/S SURAJ ASSOCIATES L2 | SANA ELECTRICALS L3 | M/s CHAUHAN ELECTRICALS L4 |
|---|---|---|---|---|---|---|---|
| 1.00Safe carriage loading unloading with proper stacking of following material from ESC Daliganj to Work Site/JE dump store. | |||||||
| 1.01 | PCC Pole 8.5 Mtr. | 200 | No. | 550 ₹1,10,000 Lowest | 550 ₹1,10,000 Lowest | 578 ₹1,15,600 | 585 ₹1,17,000 |
| 1.02 | LT ABC 3x95/120 sqmm. | 35,990 | Mtr | 25 ₹8,99,750 | 10 ₹3,59,900 Lowest | 11 ₹3,95,890 | 12 ₹4,31,880 |
| 1.03 | LT Tailless Unit 300/500 Amp | 10 | Set | 2,000 ₹20,000 Lowest | 3,000 ₹30,000 | 3,150 ₹31,500 | 3,200 ₹32,000 |
| 2.00All Decentralized Items Provided/Fixing/ Erection/Installation/Laying/Foundation with earthing by the contractor as on his own cost as per RESPO Narms. 33 KV LINE ERECTION WORK Minimum depth of laying from ground surface to the top of cable as per IS is 1)Low Voltage (1.1KV) and control cable 0.75 Mtr 2) 3.3 KV to 11 KV Cables 0.90 Mtr 3) 22 KV to 33 KV Cable 1.05 Mtr 4) Cables at Road Crossing 1.00 Mtr 5) Cable at Railway Laval Crossing ( measured from bottom 1.00 Mtr Of sleepers to top of pipe) Note- 1- The depth may be increased but not more than 1.6 Mtr 2- The Standard depth and width for laying the cable are also attached ( as per letter No 561/Director(Tech)/MVVNL/Camp/Dt 09.01.2026 with the tender form) | |||||||
| 3.00 | Proper laying & commissioning of (3X95/3X120 sq.mm) Aerial Bunched Conductor. Only ABC Provided by deptt. | 35,990 | Mtr | 28.65 ₹10,31,113.5 | 28 ₹10,07,720 Lowest | 29 ₹10,43,710 | 35 ₹12,59,650 |
| 4.00 | Dragging of ST/PCC Pole from Dump Store to pit site, digging of pit erection and grouting (As per RESPO Norms) of LT support suitable for laying of ABC Line on 8.5 Mtr Long PCC Pole by providing of necessary eye hook/Lt Shackle insulator with Clamps and its accessories etc. as per RESSPO Specification and it,s earthing at per RESPO norms. Only Pole will be Provided by the Department. | 200 | No. | 4,520 ₹9,04,000 Lowest | 7,900 ₹15,80,000 | 8,295 ₹16,59,000 | 8,310 ₹16,62,000 |
| 5.00 | Fixing of Tailless fuse Unit 300/500 Amp | 10 | No. | 10,000 ₹1,00,000 | 4,000 ₹40,000 Lowest | 4,200 ₹42,000 | 4,250 ₹42,500 |
| 6.00 | Supply and fixing of Henley type tailless fuse Unit for 250 KVA | 25 | No. | 12,000 ₹3,00,000 Lowest | 37,200 ₹9,30,000 | 39,060 ₹9,76,500 | 40,000 ₹10,00,000 |
| 7.00 | Supply and fixing of Three Phase Distribution Box | 172 | No. | 3,500 ₹6,02,000 | 2,500 ₹4,30,000 Lowest | 2,625 ₹4,51,500 | 2,650 ₹4,55,800 |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
15 Jun 2026, 12:00 pmClosed
SUPERINTENDING ENGINEER, (TECHNICAL), AMAUSI ZONE
SE, Sec-5, D, Vrindavan, Amausi Zone, Lucknow
26/SE(T)AMAUSI ZONE/2026-27
2026_MVVNL_1158429_1
26/SE(T)AMAUSI ZONE/2026-27
Open Tender
Electrical Works
Fixed-rate
90 days
LUCKNOW
As per Tender Document
2 documents required · 2 mandatory
₹3,540
E.E., EDD, CESS-Ist, LESA, Lucknow
₹45,000
22 Jun 2026
9 Jun 2026
15 Jun 2026
9 Jun 2026
15 Jun 2026
9 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Safe carriage loading unloading with proper stacking of following material from ESC Daliganj to Work Site/JE dump store. | |||||
| 1.01 | PCC Pole 8.5 Mtr. | - | No. | 100 | - |
| 1.02 | LT ABC 3x95/120 sqmm. | - | Mtr | 100 | - |
| 1.03 | LT Tailless Unit 300/500 Amp | - | Set | 10 | - |
| 2All Decentralized Items Provided/Fixing/ Erection/Installation/Laying/Foundation with earthing by the contractor as on his own cost as per RESPO Narms. 33 KV LINE ERECTION WORK Minimum depth of laying from ground surface to the top of cable as per IS is 1)Low Voltage (1.1KV) and control cable 0.75 Mtr 2) 3.3 KV to 11 KV Cables 0.90 Mtr 3) 22 KV to 33 KV Cable 1.05 Mtr 4) Cables at Road Crossing 1.00 Mtr 5) Cable at Railway Laval Crossing ( measured from bottom 1.00 Mtr Of sleepers to top of pipe) Note- 1- The depth may be increased but not more than 1.6 Mtr 2- The Standard depth and width for laying the cable are also attached ( as per letter No 561/Director(Tech)/MVVNL/Camp/Dt 09.01.2026 with the tender form) | |||||
| 3 | Proper laying & commissioning of (3X95/3X120 sq.mm) Aerial Bunched Conductor. Only ABC Provided by deptt. | - | Mtr | 10 | - |
| 4 | Dragging of ST/PCC Pole from Dump Store to pit site, digging of pit erection and grouting (As per RESPO Norms) of LT support suitable for laying of ABC Line on 8.5 Mtr Long PCC Pole by providing of necessary eye hook/Lt Shackle insulator with Clamps and its accessories etc. as per RESSPO Specification and it,s earthing at per RESPO norms. Only Pole will be Provided by the Department. | - | No. | 10 | - |
| 5 | Fixing of Tailless fuse Unit 300/500 Amp | - | No. | 10 | - |
| 6 | Supply and fixing of Henley type tailless fuse Unit for 250 KVA | - | No. | 10 | - |
| 7 | Supply and fixing of Three Phase Distribution Box | - | No. | 10 | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.68 MB
BOQ_2171063.xls
BOQ • 0.30 MB
TenderDoc.pdf
Tender Documents • 1.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .