Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC Being Lowest bidder | |
| 2 | L2₹23.7 L+₹2.2 L (10.5%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹23.8 L+₹2.3 L (10.7%)Rejected-Finance 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
8 Jun 2023, 6:00 pmClosed
Sh Himanshu, IDSE
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2023_MES_595149_1
GE(S)/PAT/T-15/N/2023-24
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Nabha
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹50,000
Yes
24 Jun 2023
13 May 2023
10 Jun 2023
13 May 2023
8 Jun 2023
26 May 2023
13 May 2023 - 19 May 2023
Amount
Dismantling of brick tiles or terracing tiles single layar on roofs complete all as specified and directed by Engr-in-Charge
Demolation of mud puska and removing on roof any thickness as directed.complete all as specified and directed by Engr-in-Charge
M&L PCC 1:3:6, type B-0 using 12.5 mm graded stone aggregates as in padding over roof ,minimum thickness at khurra as 50mm maintain a slope of 1:100 using water proofing compound complete all as specified and directed by Engr-in-Charge.
M&L PCC 1:2:4, type B-0 using 12.5 mm graded stone aggregates as in roof kerbs or mud stops/ coping etc including weathering slightly rounded or chamferred complete all as specified and directed by Engr-in-Charge
M&L for the following roof treatment. (a) 15 mm thick (average) cement screed/plaster in CM 1:4 on roof ( concrete surfces) finishing even and fair all as specified. (b) Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick weight not less than 3.60kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt, fixed as per manufacturer’s instructions complete all as specified and directed. (c) Applying one coat of bituminous primer confirming to IS-3384 @ 0.3 Ltr/Sqm. (d) Applying one coat of aluminium paint over APP membrane @ 0.50 litres per Sqm all as specified and directed. (e) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per square metre including cleaning the surfaces complete all as specified and directed by Engr-in-Charge
M&L PVC ( SWR) rain water pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete as as pecified including flat iror clamps 25x3mm complete all as specified including taking out old damaged AC rain water pipes.complete all as specified and directed by Engr-in-Charge
M&L PVC (SWR) bends of any radius for 110 mm dia rain water pipes with rubber ring joints a complete all as specified and directed by Engr-in-Charge
Taking up or down steel tubing of size15mm bore and removal to store complete all as specified and directed by Engr-in-Charge
Taking up or down steel tubing of size 20mm bore and removal to store complete all as specified and directed by Engr-in-Charge
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 20 mm bore GI tubing.complete all as specified and directed by Engr-in-Charge
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 15 mm bore GI tubing.
Dismanteling 500ltr water storage tank and removing to store complete all as specified and directed by Engr-in-Charge
S&F Rotational moulded polythene water storage tank cylindrical vertical with closed top 500ltr capacity hoisted and fixed in position incl 20 mm bore ball brass valves high pressure with polythene float and fly nut all as specified in SSR Part-1 complete all as specified and directed by Engr-in-Charge.
S &F20mm Stop valves/ gate valve , cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge
M&L Repair to RCC sunshades, Chajjas, Balconies, Columns, bands, beams, ceilings and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including cutting grooves in brick /concrete wall and preparation of surfaces to receive finishes complete all as specified and directed by Engr-in-Charge
Dismantling of asbestos cement sheets [corrugated, semi-corrugated, etc] in roof coverings complete all as specified and directed by Engr-in-Charge
Dismantling of wrought timber truss scantling 40Sq.cm and over in section framed work, provided for complete all as specified and directed by Engr-in-Charge
Dismantling of wrought timber scantling as in fillets, post rafter , purlins etc under 40Sq.cm in section framed work, provided for complete all as specified and directed by Engr-in-Charge.
M&L for rectangle / Squar /circular hollow section as in main and cross beams, hip and jack rafters purlins, where connected to common rafters and running rails and guides for structural purpose, fixed with angle cleats or other connecting plates to Fe-290 (Gde E-165) complete all as specified and directed by Engr-in-Charge
S&F for plates /cleats/connplates of Fe410-W(Gde-E-250)quality A etc for frame work all as specified.
M& L for Preparation new steel surfaces of any description not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint over one coat of red oxide as in primer complete all as specified and directed by Engr-in-Charge
S & F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed to self tapping screws as specified complete all as specified and directed by Engr-in-Charge
S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in ridges, roof covering/clading to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge
Dismantling of brick work built in cement mortar incl all quoins, arches, pillar etc complete all as specified and directed by Engr-in-Charge
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge
Taking down cement plaster of any description any thickness from external surface of walls / soffits etc including raking out joints, hacking for key, scrubbing down with water etc.complete all as specified and directed by Engr-in-Charge
M&L for cement plastering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished complete all as specified and directed by Engr-in-Charge
M & L for 15mm thick ( in two layers of 10mm and 5mm thickness) cement plastering in cement mortar 1:4 and mixig the water proofing compound as per manufactures instructions on brick or concrete surface of wall finish complete all as specified and directed by Engr-in-Charge Note : Water proofing compound shall be measured and paid saparately
Supply only integral water proofing compound ISI marked. complete all as specified and directed by Engr-in-Charge
Preparation of new plastered or unplastered surfaces of walls, two coats of cement base paint over a coat of cement primer complete all as specified and directed by Engr-in-Charge
M&L Preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion over complete all as specified and directed by Engr-in-Charge
M&L Preparation of old plastered or unplastered surfaces of walls and applying one coats of cement base paint.complete all as specified and directed by Engr-in-Charge
M&L Preparation of old plastered or unplastered surfaces of walls and applying one coat of distemper oil emulsion complete all as specified and directed by Engr-in-Charge
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-Charge
M&L anodised aluminium snap grid false ceiling of grid size 605x605mm consisting of aluminium main and "T' sections of size 25x35x1.5mm thick and wall angles of size 25x 25x 1.5 mm thick suspended with GI wire suspenders of 6mm dia of suitable length and 8-10 mm thick gypsum board, 60x60 cm size fixed with staples on snap grid complete all as specified and directed by Engr-in-Charge
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), complete all as specified and directed by Engr-in-Charge
M&L 25mm thick PCC (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregates in complete all as specified and directed by Engr-in-Charge
M&L for ceramic floor tiles of minimum size 600X600 mm 8 to 10mm thick in flooring etc set and jointed in neat cement slurry and pointed in white cement to match over and including 20mm thick screed bed in CM (1:4) laid over complete all as specified and directed by Engr-in-Charge
Dismantling posts or struts (wood,steel,or RCC) any section, including taking out embedded portion including demolition of concrete foundation and removal of waste material and making good disturbed ground ,complete all as specified and directed by Engr-in-Charge
Dismantling Chain link fencing of any size and any dia of wire,complete all as specified and directed by Engr-in-Charge
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,complete all as specified and directed by Engr-in-Charge
M & L for PCC 1:3:6, type B-1, using 40mm graded stone aggregate as in foundation for post holes ,complete all as specified and direct by Engineer-in-charge
S & F Joist, channel, angle, or tee sections, fixed independently, without connecting plates,Gde Fe-410-S as in fencing post / struts incl necessary flat iron,10mm dia MS round bars,drilling holes and binding etc. ,complete all as specified and direct by Engineer-in-charge
M&L Preparing new steel surfaces of any description,wood,steel,iron,concrete, brick, stone, etc, exceeding 10 cm width or girth and applying two coats of Black bituminous paint ,complete all as specified and direct by Engineer-in-charge
Supply and fixing chain link fencing steel galvanized fencing of size 4 mm dia and 100 x 100 mm mesh size, ,complete all as specified and direct by Engineer-in-charge
S&F mild steel, screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut, exc 5cm but not exceeding 10cm long and dia of shank 11 to 15mm ,complete all as specified and direct by Engineer-in-charge
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of flooring.,complete all as specified and direct by Engineer-in-charge
M&L Machine pressed precast concrete inter locking paver block any shape and size made of M-35 grade concrete (with grey cement and no pigment) of 60mm thickness with 6mm top layer of anti abrasive material laid over 25mm thick (compacted) fine sieved sand complete all as specified and directed.
m/s panchmukhi builders
AGGARWAL & CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .