Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.0 LAccepted-Finance 5 B 2 1ST FLOOR OPP METRO PILLOR 484 TILAK NAGAR DELHI 110018 | WEST | DELHI | 110018 | ₹54.0 L | L1 | Accepted-Finance L1, hence it is Accepted. |
| 2 | L2₹60.2 L+₹6.2 L (11.4%)Rejected-Finance | ₹60.2 L+₹6.2 L (11.4%) | L2 | Rejected-Finance L2, hence it is rejected. |
| 3 | L3₹63.7 L+₹9.7 L (18.0%)Rejected-Finance | ₹63.7 L+₹9.7 L (18.0%) | L3 | Rejected-Finance L3, hence it is rejected. |
| 4 | L4₹71.5 L+₹17.5 L (32.4%)Rejected-Finance 201 PLOT NO 32 SHALAKA BLDG TPS II JUHU ROAD SANTACRUZ WEST MUMBAI SUBURBAN MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | ₹71.5 L+₹17.5 L (32.4%) | L4 | Rejected-Finance L4, hence it is rejected. |
| 5 | L5₹77.2 L+₹23.2 L (43.1%)Rejected-Finance | ₹77.2 L+₹23.2 L (43.1%) | L5 | Rejected-Finance L5, hence it is rejected. |
| Sl No | Description | Qty | Unit | J.K.DEFENCE FIRE ENGG. SERVICES L3 | Delta Leonis Building Solutions L2 | DElite System Engineering (India) Pvt. Ltd. L4 | VOID FIRE CONSULTANTS L1 | ILLUMECH ENGINEERING L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00SH I : FIRE FIGHTING SYSTEM AND HYDRANT SYSTEM | ||||||||
| 2.00 | Supplying, Installation, Testing and Commissioning of Diesel engine driven main Fire Pump at underground pump house suitable for Automatic & Manual operation and consisting of following:
Horizontal type Split casing centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, Mechanical Seal to ensure a minimum pressure of 3.5 Kg/sq.cm at highest and farthest outlet at specified flow of 2280 lpm at 70 metre Head conforming to IS 1520, Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS& IS standard complete with auto starting mechanism, Engine Control Panel, emergency stop button, 12 volts/24 Volts electric starting equipment, 200 Ltrs Diesel day tank with water level indicator & necessary fuel line valves, Exhaust pipe extended upto 1 m outside pump house from underground pump house, duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, Residential silencer, Instruments and protection as per specification, Emergency Stop button, painted with post office red colour, M.S. fabricated Common base plate, coupling guard, including cement concrete foundation upto 600mm height, foundation bolts, AVM pads, Bellows, all sides duly plastered & painted, all interconnections between Diesel Engine to main electrical panel & fuel Pipe line connections with Day tank, body earthing with 25 x 5 mm GI earth strip etc. complete as required.
Note : As Pump is installed in UnderGround sump, the pump and motor shall be brought separately and assembled at site by OEM/Dealer as per site condition.
(Make : As per List of Preferred makes) | 1 | NO. | 9,50,000 ₹9,50,000 | 6,19,999 ₹6,19,999 | 7,00,000 ₹7,00,000 | 5,90,000 ₹5,90,000 Lowest | 8,76,780 ₹8,76,780 |
| 3.00 | Supplying, Installation, Testing and Commissioning of Electric driven main Fire pump at underground pump house suitable for Automatic & Manual operation and consisting of following:
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 Kg/sq.cm at highest and farthest outlet at specified flow of 2280 lpm at 70 Metre head conforming to IS 1520, suitable HP Squirrel cage induction motor, IE-3, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class F Insulation, conforming to IS:325, M.S. fabricated Common base plate, coupling guard, including cement concrete foundation upto 600mm height, foundation bolts, AVM pads, Bellows, all sides duly plastered & painted, body earthing with 25 x 5 mm GI earth strip etc. complete as required.
Note : As Pump is installed in UnderGround sump, the pump and motor shall be brought separately and assembled at site by OEM/Dealer as per site condition.
(Make : As per List of Preferred makes) | 1 | NO. | 7,00,000 ₹7,00,000 | 4,14,997 ₹4,14,997 | 5,00,000 ₹5,00,000 | 3,89,000 ₹3,89,000 Lowest | 7,21,965 ₹7,21,965 |
| 4.00 | Supplying Installation, Testing and Commissioing of Electric driven pressurisation pump/Jockey Pump at underground pump house suitable for Automatic & Manual operation and consisting of following:
Multistage centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal and flow of 180 lpm at 70 metres head conforming to IS : 1520, Suitable HP Squrrel cage induction motor, IE-3, TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class F Insulation, conforming to IS:325, M.S. fabricated Common base plate, coupling guard, including cement concrete foundation upto 600mm height, foundation bolts, AVM pads, Bellows, all sides duly plastered & painted, body earthing with 25 x 5 mm GI earth strip etc. complete as required.
(Make : As per List of Preferred makes) | 1 | NO. | 2,50,000 ₹2,50,000 | 1,35,193 ₹1,35,193 Lowest | 2,50,000 ₹2,50,000 | 1,40,000 ₹1,40,000 | 2,12,100 ₹2,12,100 |
| 5.00 | Providing, laying, testing & commissioning of MS Heavy class Pipe conforming to IS 1239 including cutting, welding etc. etc. complete with all fittings viz. tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts, bolts, washer, foot valve including Installation/fixing the pipe with MS supports i/c clamps, hangers as per specification etc. complete as required. (Rates includes one coat of red oxide primer and two coats of fire red synthetic enamel paint).
a)200 mm dia (Thickness 6.35 mm)
(Make : As per List of Preferred makes) | 20 | MTR | 3,000 ₹60,000 Lowest | 3,949 ₹78,980 | 4,500 ₹90,000 | 3,546 ₹70,920 | 3,481 ₹69,620 |
| 6.00Supplying, laying, jointing and testing of following sizes of MS Heavy class pipes conforming to IS-1239 including cutting, welding etc. complete with all fittings viz. tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts, bolts, washer including Installation/fixing the pipe on floor/wall with concrete blocks/MS supports i/c clamps, hangers as per specification etc. complete as required. (Rates includes one coat of red oxide primer and two coats of fire red synthetic enamel paint). (Make : As per List of Preferred makes) | ||||||||
| 6.01 | 150mm dia | 440 | MTR | 2,300 ₹10,12,000 | 2,190 ₹9,63,600 Lowest | 3,500 ₹15,40,000 | 2,790 ₹12,27,600 | 2,258 ₹9,93,520 |
| 6.02 | 100mm dia | 20 | MTR | 1,900 ₹38,000 Lowest | 1,949 ₹38,980 | 2,900 ₹58,000 | 2,110 ₹42,200 | 1,956 ₹39,120 |
| 6.03 | 80mm dia | 24 | MTR | 1,800 ₹43,200 | 1,349 ₹32,376 Lowest | 2,499 ₹59,976 | 1,680 ₹40,320 | 1,592 ₹38,208 |
| 6.04 | 25mm dia | 24 | MTR | 800 ₹19,200 | 449 ₹10,776 Lowest | 1,200 ₹28,800 | 490 ₹11,760 | 485 ₹11,640 |
Tender Value
₹71.5 L
EMD Value
₹2.1 L
Closing Date
20 Oct 2025, 9:30 amClosed
AGM(Engg-E), RHQ/SR
Operational Offices, Southern Region, RHQ, Chennai Airport, Chennai
Replacement of Fire Fighting system for Terminal Building at Puducherry Airport
2025_AAI_250054_1
Provision of Fire Fighting system for Puducherry Airport
Open Tender
Electrical Works
Item Rate
150 days
Puducherry airport
Please refer Tender documents.
15 documents required · 15 mandatory
₹1,180
₹2.1 L
24 Nov 2025
26 Sept 2025
21 Oct 2025
26 Sept 2025
20 Oct 2025
27 Sept 2025
27 Sept 2025 - 6 Oct 2025
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
TenderDoc.pdf
Tender Documents • 8.23 MB
BOQ_287496.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .