Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC AT AMRITPUR PO NB CHILKA VIA BALUGAON DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹19.8 L+₹3.0 L (17.6%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹20.1 L+₹3.3 L (19.4%)Rejected-Finance AMRITPUR PO INS CHILKA DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical 309 VINAYAK TOWER CUTTACK PURI ROAD BHUBANESWAR 751 006 | KHORDHA | ODISHA | 751006 | - | Rejected-Technical Not recommended due to Slow progress, show cause notice issued by HQ ADG (Project) Chennai in WLR for the QE Mar 2023. |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
31 Jul 2023, 6:00 pmClosed
GE Chilka
Garrison Engineer, Chilka, Odisha-752037
REPAIR REPLACEMENT AND MAINTNANCE OF INTERNAL WIRING LIGHT FITTINGS MCBs DBs AND OTHER ACCESSORIES IN ZONE I AREA AT INS CHILKA UNDER GE CHILKA
2023_MES_605839_1
GE/CHL/8885 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Wise
270 days
Garrison Engineer Chilka
MES Enlisted contractor of Class E Category b i
7 documents required · 7 mandatory
₹500
Yes
GE CHILKA
₹40,000
Yes
2 Sept 2023
27 Jun 2023
2 Aug 2023
27 Jun 2023
31 Jul 2023
8 Jul 2023
28 Jun 2023 - 6 Jul 2023
Amount
Taking down carefully copper/ aluminium point wiring for light, fan, socket or power point complete with fittings such as switches, fan regulators, light fittings, tube light fittings, bracket light fittings and ceilling rose, holders and including making good the disturbed surface on walls, complete all as directed.
M & L for point wiring with PVC insulated unsheathed multi stranded copper conductor cable, 1100 volt, FRLSH grade of size 1.5Sqmm drawn through and including surface PVC casing & caping (ISI Marked) with accessories including 1.5 sqmm copper conductor cable for earth continuty green in colour for one light point/fan point/Bell point/ 5 Amp socket independent board controlled by one 5/6 Amps one way switch, complete all as specified and as directed by Engr-in-charge. Note:-(i) All the disturbed surfaces of wall / ceiling shall be made good to match the existing wall / ceiling finishes and as directed by the Engineer-in-Charge. (ii) Unserviceable hylem sheet and ms sunken boxes/PVC boxes wil be replaced as per requirment and same shall be measured and paid seperatly under relevant items of this schedule.
Ditto all as per item No 2 above but, one socket outlet, three pin, 5/6 Amp on the same board with other switches
Ditto all as per item No 2 above but for one light point controlled by two 5/6 Amps two way switch
Ditto all as per item No. 2 above but for 15/16Amp switch socket out let, independent with 2.5 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 2.5 Sqmm for earth continuity conductor, complete all as specified
Supply and fixing of switch paino, flush type, single pole, one way, 5/6 Amp, complete all as specified.
Supply and fixing of bell push, 5 Amp, 230Volt, complete all as specified.
Supply and fixing of bell electric Ding Dong type, Ac 230 volts fixed complete all as specified
Supply and fixing of ceiling rose, surface Bakelite 65 x 30mm, three terminals, complete all as specified.
Supply and fixing of switch socket combination 2 pin & 3 pin 5 Amp, 230 volt, multipurpose, 2 screw to fix on board complete all as specified.
Supply and fixing of switch socket combination 5 in 1 type, 3 pin 5 / 15Amp, 230 volt, multipurpose, 4 screws to fix on board complete all as specified.
Supply and fixing of Fan regulator, electronic step type for ceiling fan of any sweep including connecting in circuit with three core flexible PVC copper conductor of size 1.5 Sq.mm, complete all as specified.
Supply and fixing of switch paino, flush type, single pole, two way, 5/6 Amp, complete all as specified.
Supply and fix in replacement of factory made sheet metal enclosure with protected type 2 pin and earth plug and complete socket with one MCB SP 240 volt, 20 Amps all as specified.
Supply and fix in replacement 9 W tubelight fitting with lamp, Endura linear LED Wall mounted LED batten with polycarbonate housing & intergated driver for efficient heat dissipation having THD<20% with ccomplete fitting all as specified and as directed. Make-Bajaj/Havells/CG/Philips
Supply and fix in replacement of 10 Watt LED Bulk Head fitting Environmenatal friendly, ultra morden, energy saving, surface mounted, decorative oval bulk head edge- lit LED luminaries comprising of high brightness LEDs complete all as specified and as directed. Make-Bajaj/Havells/CG/Philips
Supply and fix in replacement of 20 W tubelight fitting with lamp, Endura linear LED Wall mounted LED batten with polycarbonate housing & intergated driver for efficient heat dissipation having THD<20 % with complete fitting all as specified and as directed. Make-Bajaj/Havells/CG/Philips
Supply and fix in replacement 18 Watt T-8 LED retrofit tubelight in existing fitting complete all as specified and as directed. Make : Havells cat part No PHOTONULTRA1213T8SSTL18WLED865SPC (LED Lamp) or equivalent model in crompton Greaves/ Phillips
Supply and fix in replacement of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt, 8 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete all as specified. Make- C&S/Standard/Havells/Indoasian.
Supply and fix in replacement of Factory made sheet metal enclosure for DBs single door (Fixed flush to the wall), SPN, 240 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified. Make- C&S/Standard/Havells.
Supply and fix in replacement of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified. Make- C&S/Standard/Havells.
Supply and fix in replacement of MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, as complete all as specified Make- C&S/Standard/Havells.
Supply and fix in replacement of MCB 32 Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, as, complete all as specified Make- C&S/Standard/Havells.
Supply and fix in replacement of MCB 63Amp, 415 Volt, TPN, breaking capacity 10 KA 'C' series, as complete all as specified Make- C&S/Standard/Havells.
Taking down and re-fixing of existing hanging conduit wiring with proper saddles, complete all as specified. Note :- (i) Unsv PVC conduit will be measured and paid separately (ii) Making good distrubed surface deemed to be inclusive of quoted rate
Supply and fixing in repair of Hylem sheet (ISI Marked) of size 9X11inch with 4 no of screws and washers all as directed by Engr-in-charge.
Supply and fixing in repair of Hylem sheet (ISI Marked) of size 5X7 inch with 4 no of screws and washers all as directed by Engr-in-charge.
Supply and fixing in repair of Hylem sheet (ISI Marked) of size 5X5 inch with 4 no of screws and washers all as directed by Engr-in-charge.
Supply and fixing in repair MS sunken box of size 8 x 10 inch with 4 no of screws and washers including taking down the existing and making good to match the existing surface complete all as directed by Engr-in-charge.
Supply and fixing in repair MS sunken box of size 4 x 6 inch with 4 no of screws and washers including taking down the existing and making good to match the existing surface complete all as directed by Engr-in-charge.
Supply and fixing in repair MS sunken box of size 4 x 4 inch with 4 no of screws and washers including taking down the existing and making good to match the existing surface complete all as directed by Engr-in-charge.
M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galavanised lead wire 4.0 mm dia (upto 7.5 M in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel complete all as specified and testing on completion.
S&F in repairs earth continuity fixed to wall on batten or rececc or chases or buried in ground or drawn in conduit/pipe or other indicated situation for loop earthing etc as required 4mm dia GI or steel earth wire complete all as specified.
S&F in repairs earth continuity fixed to wall on batten or rececc or chases or buried in ground or drawn in conduit/pipe or other indicated situation for loop earthing etc as required 6 mm dia copper multi stranded earth wire complete all as specified.
supply and fix in repairs sub main wiring with two run of 4.0 Sq. mm PVC sheathed, copper conductor cable, 1100 Volt, FRLSH grade and one run of copper earth wire 4.0 Sq mm drawn through PVC casing and caping, complete all as specified. Note : Copper conductor 2 run and one run of copper earth wire along with PVC casing and caping shall be measured as one length and including making good the disturbed surface and matching the colour of wall with the existing colour of the wall with wash/paint/distemper whenever required will be included in quoted rates.
supply and fix in repairs sub main wiring with two run of 6.0 Sq. mm PVC sheathed, copper conductor cable, 1100 Volt, FRLSH grade and one run of copper earth wire 6.0 Sq mm drawn through PVC casing and caping, complete all as specified. Note : Copper conductor 2 run and one run of copper earth wire along with PVC casing and caping shall be measured as one length and including making good the disturbed surface and matching the colour of wall with the existing colour of the wall with wash/paint/distemper whenever required will be included in quoted rates.
Taking down the complete hanging lamp fitting of any type and any location and refixing the same with accessories, including provision for cable from celling rose to fitting, complete all as spcefied.
Supply and fixing in repair 15 Amp Switch complete all as specified and directed by Engr in Charge
Supply and fix in replacement of LED street light 25W, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-charge. Make-Bajaj/Havells/CG/Philips
Supply and fix in replacement switch paino, flush type, single pole, one way, 5/6 Amp, complete all as specified and as directed.
Supply and fix in replacement ceiling rose, surface Bakelite 65 x 30mm, three terminals, complete all as specified and as directed.
Supply and fix in replacement of bell push, 5 Amp, 230Volt, complete all as specified and as directed.
Supply and fix in replacementr of bell electric Ding Dong type, Ac 230 volts fixed in repair, complete all as specified and as directed.
Supply and fix in replacement of Fan regulator, electronic five step socket type for ceiling fan of any sweep including connecting in circuit with three core flexible PVC copper conductor of size 1.5 Sq.mm, complete all as specified and as directed.
Supply and fix in replacement switch socket combination 2 pin & 3 pin 5 Amp, 230 volt, multipurpose, 2 screw to fix on board complete all as specified and as directed.
Supply and fix in replacement switch socket combination 5 in 1 type, 3 pin 5 / 16Amp, 230 volt, multipurpose, 4 screws to fix on board complete all as specified and as directed.
Supply and fix in replacement switch socket combination 2 pin & 3 pin 5 Amp, 230 volt, multipurpose, 2 screw with PVC box fix on wall complete all as specified and as directed.
Supply and fix in replacement switch socket combination 5 in 1 type, 3 pin 5 / 16Amp, 230 volt, multipurpose, 4 screws with PVC box to fix on wall complete all as specified and as directed.
Supply and fix in replacement of switch paino, flush type, single pole, two way, 5/6 Amp, complete all as specified and as directed.
S&F in repairs sub main wiring with 4 runs of 6 sqmm PVC insulated unsehathed copper cable multistand 1100 V of FRLSH grade with drawn in surface casing-caping not less than 25mm dia and one run of PVC insulated unserviceable of 6 sqmm as earth continuity conductor drawn in PVC conduit / casing and capping with accessories complete NOTE: 4 runs of 6 Sqmm, 1 run of 6 Sqmm and 1 run of casing capping will be measured as one unit i.e RM and including making good the disturbed surface and matching the colour of wall with the existing colour of the wall with wash/paint/distemper whenever required will be included in quoted rates.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth all as directed by Engr-in Charge.
S&F in repair Rigid non-metallic PVC conduit of size 32 mm in dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc
S&F in repair Rigid non-metallic PVC conduit of size 25 mm in dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc
S&F in repair Rigid non-metallic PVC conduit of size 20 mm in dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc
Supply and fix in repairs round dummy plate for electric wiring junctions, Complete all as specified
Supply and fix in repairs PVC rectangular block for mounting, switches, sockets, fan regurators etc with 3 mm thick plastic laminated sheet cover of size 100mmX100mm and 50 mm deep, Complete all as specified
Supply and fix in repairs PVC rectangular block for mounting, switches, sockets, fan regurators etc with 3 mm thick plastic laminated sheet cover of size 175mmX100mm and 50 mm deep, Complete all as specified
Supply and fix in replacement LED retrofit lamp B22 holder base with polycarbonate body and aluminium heat sink of 09/10W all as specified and as directed. Make : Bajaj/Havells/Philips
Supply and fix in replacement angle holder for LED bulb of any type Complete all as specified
Supply and fix in replacement of modular switch 1 way 6 Amp 1 module complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of modular socket 6 Amp 2/3 pin combined 2 module complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of modular socket 6/16 Amp 2/3 pin combined 2 module complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of modular fan regulator 2 module complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of modular switch 1 way 16 Amp 2 module complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacement street light bracket fabricated from 25mm dia medium grade GI pipe bent to shape not exceeding 1.5mtr long alongwith 2 Nos clamps of size 32x6mm flat iron and including nuts, bolts, washers suitable for fixing on Buildings including 2 coats of synethic enamel paint over a coat of red oxide primer complete all as specified
Supply and fix in replacement 18 Watt ultra bright glass T-5 LED aluminium heat sink & polycarbonate diffuser retrofit tubelight in existing fitting with internal driver and high efficiency complete all as specified and as directed. Make : Havells cat part No TITANIASLEEK1149T5DSTL18WLED865SPC(LED Lamp)or equivalent model of Phillips/ Crompton Greaves
S & F in repairs sub main wiring with 4 runs of 10 sqmm PVC insulated unsehathed copper cable multistand 1100 V of FRLSH grade with drawn in surface casing-caping not less than 32 mm dia and one run of PVC insulated unserviceable of 6 sqmm as earth continuity conductor drawn in PVC conduit / casing and capping with accessories complete NOTE: 4 runs of 10 Sqmm, 1 run of 6 Sqmm and 1 run of conduit will be measured as one unit i.e RM and including making good the disturbed surface and matching the colour of wall with the existing colour of the wall with wash/paint/distemper whenever required will be included in quoted rates.
Supply and fix in replacement of 36 W, 240 Volt, 50 HZ LED recessed mounted 2X2 tile, glare free uniform illumination having THD<20 %, Cool day light temp, with complete fitting all as specified and as directed and including making good the disturbed surface and matching the colour of wall with the existing colour of the wall with wash/paint/distemper whenever required will be included in quoted rates. Make-Bajaj/Havells/CG/Philips
Supply and fix in replacement of 12 W, 240 Volt, 50 HZ LED recessed mounted glare free uniform illumination having THD<20 %, Cool day light temp, with complete fitting all as specified and as directed. Cat part no LSDSMN-12W-CDL of Make CG or its equivalent in Bajaj/Havells/Philips
M/S KAMAL KEE ENGINEERS WORK
PRASANTA KUMAR PANDA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .