Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.9 LAccepted-AOC H NO 2 19 1 VELGANOOR VILLAGE DANDEPALLI MANDAL MANCHERIAL DISTRICT TELANGANA 504 215 | PRAKASAM | ANDHRA PRADESH | 504215 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹48.6 L+₹2.1 L (4.41%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹49.3 L+₹2.8 L (5.97%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹49.3 L+₹2.8 L (6.08%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹49.6 L+₹3.1 L (6.68%)Rejected-Finance 94A APR COLONY BILHARI JABALPUR MP | JABALPUR | MADHYA PRADESH | 482020 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹48.2 L
EMD Value
₹96,380
Closing Date
10 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIRS TO ROOF IN TECHNICAL LABS AND TEST BEDS IN ASL BLDGS INSIDE DRDL AREA, BRAHMOS, QRSAM AREA UNDER AGE BR-I, KANCHANBAGH, HYDERABAD
2024_MES_675737_1
8865
Open Tender
Civil Works
Item Rate
180 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹96,380
Yes
6 Jan 2025
20 Sept 2024
12 Oct 2024
20 Sept 2024
10 Oct 2024
4 Oct 2024
21 Sept 2024 - 26 Sept 2024
Amount
Demolition of cement concrete in any position incl removal of any type of old treatment, tarfelt & debries etc complete all as specified & directed by Engr-in-Charge.
Demolition of Cement Concrete (Reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for and removing the same from Site(s), complete all as specified and as directed.
M&L Pre-painted galvalume aluminium zinc coating GI based corrugated /trepezoidal steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws including dismantling old AC sheet complete all as specified and directed.
M&L Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in ridges fixed with self tapping screws including taking down old ridges complete all as directed.
Cleaning of Roof gutter including water outgoing holes at any hight of bldg,work shop and hangers and removing the materials leaves, vegitation mud or oter waste materials to distance n exc 50m, complete all as specified and directed by Engineer-in-Charge.
Cutting /removing of plants and grass growth on bldg's roofs, chajjas and edges on bldgs,work shop, hangers (at any floor and any height) including spreding chemicals at plant roots area and finished the damaged area with PCC 1:2:4/ Cement plaster in CM 1:4 as required and remove the wast to distance n exc 50m, complete all as specified and directed by Engineer-in-Charge.
Cleaning of Roof sorrounding area mud, tree leaves etc including water outgoing holes at any hight of bldg, removing the materials (sludge) to distance n exc 50m, complete all as specified and directed by Engineer-in-Charge.
Cleaning of drains by excavating of the filled earth. Vegetation and all forged material average width 45 cm & depth 50cm and removing the excavated material to a distance exc. 50m and not exc. 250m complete all as specified and as directed
M&L Brick work with sub- class 'B' class bricks straight or curved on plan exc 6m mean radious in CM (1:6), including demolition of brick work complete all as specified and directed by Engineer-in-Charge.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs etc and holding if required reconnection and refixing in position, capacity of tank exc 250 & n.exc 500 Ltrs capacity complete all as specified.
All as item No.10 above but for capacity of tank exc 500 & n.exc 1000 Ltrs capacity complete all as specified.
M&L for 40mm thick PCC type B0, 1:2:4 (using 12.5 mm graded aggregate) as in padding in roof complete all as specified. Note: (Work shall be carried out upto G+2 storey bldg, contractor to quote rates accordingly).
M&L for cement screed/rendering 10mm thick in C.M (1:3) over roof slab including parapets inverted beams etc. mixed with water proofing compound, rendering all as specified and directed (WPC shall be measured and paid separately and finished even and smooth without using extra cement complete all as directed by engr-in- charge. Note:- WPC will be measured & paid separately.
M&L for APP based polymeric membrane minimum weighing 3Kgs/Sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) over a coat of hot bitumen 85/25 grade applied @ 1.20 Kg/Sqm after priming the surface with bitumenious emulsion (tack coat) @ 100 gms/sqm with 10 cm overlap of the membrane to be provided duly fused uniformly by LPG torch flame complete all as directed .
M&L for preparation of surface and applying one coat of aluminium paint @ 100 ml/sqm over APP membrane all as specified and directed.
Supply only liquid water proofing compound.
Waterproofing for terrace: (i) Cleaning the surface areas thoroughly so that they are free of all contaminants like dirt and laitance & to remove all the loose materials by various mechanical means. Removal of all surface Imperfections, protrusions, loose concrete & filling of cracks using Seal PU or Polymer Modified Mortar in the ratio Seal Crete : Cement : Sand (1 : 2 : 5 ) . (ii) Providing and making vata at the junction of the walls and the slabs using PMC mortar in the ratio of Seal Crete : Cement : Sand (1 : 2: 5 ) using SBR Latex as the bond coat. (iii) Correct all construction joints by grouting wth grout IP at 1m apart and opening of joints in "V" cut groove and fill with PMC mortar, using SBR Latex as the bond coat. (vi) Providing and applying brush applied water based PU dispersed polymer modified Elastomeric liquid membrane, Urethane BTD with Zero VOC to form the membrane in situ at site with 3 layers of monolithic, seam less finish having > 500% elongation The first layer is to be apply primer @ 200 Gms per Sqm and shall act as the prime coat to fill in the cavities. This can be brush or roller applied. For spray application, using any airless spray system with recommended nozzle size at 30:1 at 2 bar pressure.
(v) Providing and applying the second coat @ 1 kg per Sqm using the soft brush, roller or Spray system with the recommended nozzle size on to the primed surface. Providing and applying 45 Gsm Fiber cloth over the 1 st coat,when substrate till the coat is tacky Providing and applying 3 rd coat @ 1 kg per Sqm to finish the application for a thickness of 1.5 mm membrane formed in place. The second coat should be applied perpendicular to the first coat for cross linkage and complete as per the specification. (vi) Top Screed modified with Integral Waterproofing Chemical: Placing a seperation layer of 120 GSM geotextile fabric over the waterproofing membrane and carrying out sloping screed on top of it over the with cement modified @ 0.4% with Manufacturer plast LW+ for waterproofing.
Notes: - 1. To be applied by the Rep of manufacturers authorized applicator only. Contractor has to provide manufacturer’s test certificate for the above mentioned Technical parameters and purchase Vrs. 2. Removal of existing treatment to be paid separately. 3. Roof top to be ensured to avoid water ponding. 4. For accessible terrace and inaccessible terrace, 300mm height of vertical surface/ parapet wall to be treated with same specification of slab. Make: - STP , Bostik, Berger, Fosroc, Sika, Asian or any other make approved by E-in-C’s Branch for PU based water proofing treatment.
M&L PCC 1:2:4 type B-0 (using 12.5 mm grade stone agg)as in roof kerbs,mud stops, rounded or chamfered on edges complete all as specified and directed
S&F 20mm thick hydraulically pressed cement tiles laid over 15mm thick cement screed bed 1:6 mixed with water proofing compound and joined with CM 1:3 mixed with 5% crude oil by weight of cement over APP membrane,incl dismantling of old PCC tiles.
All as per item No.19 above but except tiles
Framed work such as grills, gratings etc with ends of bars shouldered and or riveted or forged into spikes framed guard bars barred iron doors ladders framed balusters walk ways railings framework of water tanks and similar work conforming to Fe- 290. Gde E-165 including dismantling wrought iron complete all as specified and as directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats Fe-290 (Gde E?165) ec., including dismantling wrought iron complete all as specified and as directed.
Preparation of two coat synthetic enamel paint with one coat of red oxide primer on new or previously untreated steel surface of any description over 10 cm in width or girth not otherwise described.
S&F in repairs 3mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with coach screw and washer in roof, wall etc.
S&F in repairs 12mm thick glass reinforced gypsum (GRG) ceiling tiles of size 595 x 595mm of approved design fixed with powder coated (powder coating on web bottom only) GI grid consisting of main Tee section of size (15mm x 30mm), cross Tee section of size (15mm x 23mm) and powder coated GI wall angle of size (20mm x 20mm) suitable for mounting tiles of 595 x 595mm with 4mm dia GI wire suspender including fabrication complete as per manufacturers instructions fixed with steel rawl plug with nut and bolts arrangement with grid size 60x120cm complete all as specified and directed by Engineer - in -Charge. Make : Diamond Brand TM/ Dexune or equivalent approved by GE
S&F in repairs 12mm thick glass reinforced gypsum (GRG) ceiling tiles of size 595 x 595mm of matching design fixed in existing frame at any height complete all as specified and as directed by Engineer-in-Charge. Make : Diamond Brand TM/ Dexune or equivalent approved by GE
M&L for preparation of old distempered surfaces of walls by washing, rubbing down and stopping and applying one coat of oil emulsion distemper complete all as directed.
M&L for preparation of old distempered surfaces of ceiling by washing, rubbing down and stopping and applying one coat of oil emulsion distemper complete all as directed.
M&L for preparation of old distempered surfaces of walls by washing, rubbing down and stopping and applying one coat of weatherproof antifungal exterior paint complete all as directed.
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as directed.
M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as directed.
S & F PVC (SWR) pipes 110mm bore, single socketed in any length with rubber ring joints fixed to wall or laid in floors including taking down old pipe complete all as directed.
S & F PVC (SWR) pipes 150mm bore, single socketed in any length with rubber ring joints fixed to wall or laid in floors including taking down old pipe complete all as directed.
S&F 150mm PVC (SWR) bends with access door of any radius all as specified & directed.
M&L for PCC (1:2:4) type B-2(using 40 mm graded stone aggregate) of 100 mm thick as in plinth protection / Path / PCC floor, finished even and fair, complete all as specified and as directed.
S&F 15mm bore Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors etc including taking down old tubing complete all as specified and as directed.
S&F 20mm bore Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors etc., including taking down old tubing complete all as specified and as directed.
S&F 25mm bore Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors etc., including taking down old tubing complete all as specified and as directed.
S&F in repair 20mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
S&F in repair 25mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
S&F in repair 25 mm bore Ball valves high pressure of PTMT with epoxy coat ed Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0mm-210gms./ 25mm-455gms)
Cleaning and removing all scale and dirt, etc, from tanks of exc 500 & nesc 1000 ltr capacity and from mouths of circulating pipes, etc. complete all as specified and as directed.
M&L for 1000 ltr capacity Rotational moulded polyethylene water storage tanks tripple layer ISI Mark (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I incl dismantling of old tanks.
M/s Kasturi Pedda Subbaiah Enterprises/M/s K.P.S Enterprises (BID ID -3133354)
Venkat Sai Enterprises (BID ID -3134423)
PAVAN ENTERPRISES (BID ID -3131856)
Ravi Enterprises (BID ID -3132206)
MM PROJECTS (BID ID -3134809)
MVS ENTERPRISES (BID ID -3132077)
SRI SAI ENTERPRISES (BID ID -3132180)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .