Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LQualified | L1 | Qualified MII | |
| 2 | L2₹1.9 L+₹560 (0.30%)Qualified 22 14A CHAMAN VIHAR EXT CONEL COLONY AKHIL LANGER TALAB TILLO JAMMU TALAB TILLO JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Qualified MII | |
| 3 | L3₹2.2 L+₹39,832 (21.5%)Qualified F 18 15 JOGABAI EXTENSION JAMIA NAGAR OKHLA OKHLA SIR SYEED ROAD NEW DELHI SOUTH DELHI DELHI 110025 | SOUTH EAST DELHI | DELHI | 110025 | L3 | Qualified MII | |
| 4 | L4₹2.3 L+₹47,300 (25.6%)Qualified H NO 315 LANE NO 10 TALAB TILLO JAMMU JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L4 | Qualified MII | |
| 5 | L5₹2.4 L+₹58,410 (31.6%)Qualified 310 COLONEL COLONY BOHRI JAMMU JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L5 | Qualified MII |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
6 Aug 2022, 7:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
REPAIR
3641198
GEM/2022/B/2399461
REPAIR AND MAINTANCE,REPAIR AND MAINTANCE,REPAIR AND MAINTANCE,REPAIR AND MAINTANCE,REPAIR AND MAIN
30 days
Jammu And Kashmir; Udhampur
Total value wise evaluation
BOQ
8 documents required · 8 mandatory
3 yrs
50%
Exempted
6 Aug 2022
31 Jul 2022
6 Aug 2022
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | REPAIR AND MAINTANCE | Disconnecting electrical connections from HT and LT sides of old serviceable/ damaged/ burnt step down transformers of any descriptions, capacity 100 KVA, any type and taking down from the platforms or mounted on exisiting position (four poles/ two pole structure) by hydraulic cranes of suitable capacity and transporting by truck/ lorry to the workshop, opening top cover, draining out the transformer oil in clean barrels, cleaning of sludge from oil tank and conservator tank, cleaning and polishing of tapping contact point, refitting top cover with replacement of studs, nuts, bolts, washers and gasket after repairs/ replacement of unserviceable parts and cleaning the transformer and making the transformer absolutely leak proof, pouring in the insulating oil in the transformer, placing in original position on four pole/ two pole structure/ platform at site and making all HT/LT connections including testing the transformer after necessary repairs, complete all as specified and as directed by Engineer-in-Charge. | 1 | EACH | AGEI-U | 30 |
| 2 | REPAIR AND MAINTANCE | Replacement of old unserviceable/ damaged HT bushing assembly with new HT bushing assembly (Set of three) with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, capacity 200 KVA, complete all as specified and as directed by Engineer-in-Charge. | 1 | EACH | AGEI-U | 30 |
| 3 | REPAIR AND MAINTANCE | Replacement of old unserviceable/ damaged tap changing assembly with new tap changing assembly, off load, on HT winding to vary the voltage �7.5%, in steps of 2.50%, including necessary connection, HT winding, re-insulation for complete functioning of tap changer, transformer capacity 200 KVA, complete all as specified and as directed by Engineer-In-Charge. | 1 | EACH | AGEI-U | 30 |
| 4 | REPAIR AND MAINTANCE | Replacement of old unserviceable/ damaged LT bushing assembly with LT bushing assembly (Set of Four) with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, capacity 200 KVA, complete all as specified and as directed by Engineer-In-Charge. | 1 | EACH | AGEI-U | 30 |
| 5 | REPAIR AND MAINTANCE | Replacement of old unserviceable/ damaged air breather assembly with new air breather assembly with silica gel suitable for 11/0.433 KV transformer including nuts, bolts and washers, suitable for transformer 200 KVA, complete all as specified and as directed by Engineer-in-Charge. | 1 | EACH | AGEI-U | 30 |
| 6 | REPAIR AND MAINTANCE | Dehydration and filtration of transformer oil after draining out oil from transformer by the dehydration machine at site or nearby transformer workshop to achieve di-electric strength 40 KV at 4mm gap, complete all as specified and as directed by Engineer-in-Charge.
Note Cost of transportation of dehydration machine and other required materials and tools, plants shall be deemed to be included in the quoted rates. | 75 | PER LITER | AGEI-U | 30 |
| 7 | REPAIR AND MAINTANCE | Supply only fresh transformer oil to top.up and filling in the existing transformer, di.electric strength not than 45 KV, meeting Bureau of Indian Standards IS 335 1993 Reaffirmed.2005 specification, examined in a 100mm thick layer at 270�C, clear, transparent and free from all type of suspended matter or sediment, complete all as specified and as directed by Engineer-in-Charge. | 100 | Per LITER | AGEI-U | 30 |
| 8 | REPAIR AND MAINTANCE | Supply and fixing in replacement of HT coil of transformer capacity 100 KVA, made of super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engr-in-Charge.
Note HT coil shall have same number of turns of winding wire and with matching to manufacturer design. | 60 | Per Kg | AGEI-U | 30 |
| 9 | REPAIR AND MAINTANCE | Supply and fixing in replacement of LT coil of transformer capacity 200 KVA, made of super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-in-Charge.
Note LT coil shall have same number of turns of winding wire and with matching to manufacturer design. | 30 | Per Kg | AGEI-U | 30 |
| 10 | REPAIR AND MAINTANCE | Preparation of old, external surface of transformers capacity 100 KVA, by removing the scrap, dust/ rust, washing and cleaning including cleaning and spray painting with two coats of synthetic enamel paint including numbering MES No in white colour synthetic enamel paint, complete all as specified and as directed by Engineer-in-Charge. | 1 | EACH JOB | AGEI-U | 30 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_3641198.pdf
GEM_BID
specification_2022-07-31-17-55-29_84845e0144c15ee735024578aef95f78.pdf
BOQ
boq_item_sample_file_2022-07-31-17-55-29_f553f90a780cc17023dce6d3002535bf.csv
BOQ
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .