| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC B 1 16 MILAN GARDEN SABHAPUR EXTENSION NEAR BHIKAM SINGH TUBE WELL NEW DELHI 110094 | NORTH EAST | DELHI | 110094 | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹18.7 L+₹2.0 L (11.9%)Rejected-Finance THIS INFORMATION IS NOT AVAILABLE IN THE PROVIDED DOCUMENT | KAMRUP METRO | ASSAM | 781005 | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹18.9 L+₹2.2 L (12.9%)Rejected-Finance RANGIYA STATION ROAD WARD NO 2 PO RANGIYA DIST KAMRUP ASSAM PIN 781365 | BAKSA | ASSAM | 781365 | L3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L4₹19.3 L+₹2.6 L (15.4%)Rejected-Finance P O RANGIA WARD NO 3 DIST KAMRUP ASSAM | KAMRUP | ASSAM | 781354 | L4 | Rejected-Finance BEING L4 BIDDER | |
| 5 | Rejected-Technical | - | Rejected-Technical 10 WKS STILL PENDING AND SLOW PROGRESS WOULD BE INITIATED FOR QTR ENDING JUN 2022 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
14 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE RANGIA
GE Rangia C/O 99 APO Rangia
REPAIRS TO SEWAGE LINES, SEPTIC TANKS SOAK WELL, MANHOLES AND OTHER ALLIED WORKS AT CHANGSARI AND RANGIA MILITARY STATION UNDER GE RANGIA
2022_MES_524834_1
8560/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
RANGIA AND CHANGSARI
AS PER NIT
9 documents required · 9 mandatory
₹500
GE RANGIA
₹40,000
Yes
11 Jul 2022
19 May 2022
16 Jun 2022
19 May 2022
14 Jun 2022
2 Jun 2022
75 days
Amount
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work built in any cement mortar including obtaining brick bats from demolished bricks and filled it to the existing soak wells at foul position complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specificied provided for, complete all as per specified and as directed by Engineer-in-charge.
Cleaning of sewage line of any diameter and of any description including manholes by manually or other means, to clear the sludge/blockage inside the sewage line and manholes and will be flushing with water to drain out sludge etc. inside the sewage line from manhole to ease the flow of sewage including removing the sludge and re- fixing the manhole cover complete all as specified and as directed by Engineer-in-charge.
Cleaning of manhone including removal of sludge of any size and depth upto 0.75 meter complete all as specified and as directed by Engineer-in-charge.
Cleaning of manhone including removal of sludge of any size and depth from 0.75 meter to 1.50 meter complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D2 ( using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC (1:2:4) type B-1 ( using 20 mm grade crushed stone aggregate) as in benching/coping including necessary form work mould and finished exposed surfaces even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
M&L for for precast cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified and as directed by Engineer-in-charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends complete all as specified and as directed by Engineer-in-charge.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan 6m mean radius in cement mortar 1:6 complete all as per specified and as directed by Engineer-in-charge.
M & L for Brickwork with sub-class 'B' bricks in one brick thick honey comb walling, built in CM 1:6 complete all as specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge.
Demolition of unreinforced cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as per specified and as directed by Engineer-in-charge.
M&L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in plinth protections/foothpath, finished even and smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge.
M&L for 75 mm thick PCC type C-2 1:3:6 using (40mm gradded aggregate) as in sub base complete all as per specified and as directed by Engineer-in-charge.
S&F Non-skid colour ceramic tiles (300x300) x 6 to 7mm thick in floors/skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including over 15 mm thick screed bed or bedding layer of CM (1:6) for laying floor surface finishes, complete all as specified and as directed by Engineer-in-charge
S&F for coloured glazed ceramic tiles (300x200) x 6 or7mm thick, in dado/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over 10 mm thick screed bed or bedding layer of CM (1:6) for laying floor surface finishes, complete all as specified and as directed by Engineer-in-charge
M&L 15mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:4), mixing with water proofing compound @2% by weight of cement consumed and surface finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. Note: WPC shall be measured and paid separately as supply only under relevent item.
Supply only integral water proofing compound confirming to IS complete all as per specified and as directed by Engineer-in-charge.
S&F in repair 110 mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair 75 mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors, complete all as per specified and as directed by Engineer-in-charge.
S&F of 150 mm internal diameter of double wall corrugated (DWC) high density polyethelene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked (with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 part-2 complete all as per specified and as directed by Engineer-in-charge.
S&F in repair PVC (SWR) 110 mm bore bends complete all as per specified and as directed by Engineer-in-charge.
S&F in repair 75 mm dia bore PVC (SWR) bends, complete all as specified and as directed by Engineer-in-charge.
S&F in repair 75 mm dia bore PVC (SWR) junction (single T) equal or un-equal fixed to walls including all necessary work, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair 110 mm dia bore PVC (SWR) junction (single T) equal or un-equal fixed to walls including all necessary work, complete all as per specified and as directed by Engineer-in-charge.
S&F cast iron (sand cast) soil, waste and vent pipes 100mm bore ISI Marked, in any length with or without ears with cement joints laid in trenches or in floors complete all as specified and as directed by Engineer-in-Charge.
S&F in repair cast iron (sand cast) fittings ISI Marked such as bends (any radius), diminishing pieces or tapers (larger bore measured) for 100mm bore complete all as specified and as directed by Engineer-in-Charge.
M&L for 100mm dia (internal) salt glazed stone ware drain pipes (Grade A) ISI Marked as in sewage lines laid in trenches and jointed complete all as specified and as directed by Engineer-in-charge.
M&L for 150mm dia (internal) salt glazed stone ware drain pipes (Grade A) ISI Marked as in sewage lines laid in trenches and jointed complete all as specified and as directed by Engineer-in-charge.
Dismantaling of cast iron or reinforced concrete drain pipes 100mm dia (internal) jointed in cement mortar and taking out from the trenches complete all as specified and as directed by Engineer-in-charge.
Demolition and breaking up including removing salt glazed stoneware or DWC HDPE pipe 150mm bore (internal) with concrete bedding and haunching complete including necessary earth work as required complete all as specified and as directed by Engineer-in-charge.
Demolition and breaking up including removing salt glazed stoneware or DWC HDPE pipe 100mm bore (internal) with concrete bedding and haunching complete including necessary earth work as required complete all as specified and as directed by Engineer-in-charge.
M&L for concrete bed 1:3:6 type C2 (40 mm graded stone aggregate) to 150 mm dia. drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as per specified and as directed by Engineer-in-charge.
M&L for concrete bed 1:3:6 type C2 (40 mm graded stone aggregate) to 100 mm dia. drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as per specified and as directed by Engineer-in-charge.
Demolition of reinforcement cement concrete pipe of 300mm dia below GL complete all as specified and as directed by Engineer-in-charge.
M&L for reinforced concrete pipes of dia 300mm class NP2, laid and jointed complete with collars complete all as specified and as directed by Engineer-in-charge.
S&F in repair Vitreous China squatting pan "Orissa" patern size 580x440mm white with integral foot rest including connection to trap and to flushing pipe, anti-syphonage pipe, etc including 'P' or 'S' trap complete all as per specified and as directed by Engineer-in-charge.
S&F in repair PVC Low level flushing cistren 10 Ltr capacety including all fitting such as flush pipe brackets complete all as per specified and as directed by Engineer-in-charge.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for pipe of internal dia. 150mm, complete all as specified and as directed by Engineer-in-Charge.
Opening of blokage to nahni trap,WC, floor trap,exc including washing/cleaning upto Ist manhole complete all as specified and as directed by Engineer-in-charge.
Opening of blokage to gully trap,of WC outlet, including washing/cleaning upto Ist manhole complete all as specified and as directed by Engineer-in-charge.
Cleaning of septic tanks of any capacity with removing of sludges etc and carrying to a distance exc 100 meters but n.exc 250 meters and depositing in ditches and deposited with spreading and leveling of excavated soils in the ditches over the sludge, removing surplus soils to a distance n.exc 50m and supply and sprinkling bleaching powder over the area of ditches with one meter around complete all as per specified and as directed by Engineer-in-charge. (Note: Excavation and bleaching catered separately)
All as per serial item No 49 above but cleaning of manholes of any size and depth.
Rough excavation in soft/loose soil and getting out for shallow pit n. exc 1.5 m deep and spraying adequate quantity of bleaching powder inside the bottom pits and its walls as well over the sludge for hygienic condition, and spreading levelling in layers the excavated earth on the shallow pits to cover the sludge in the pit, complete all as specified and as directed by Engineer-in-charge. Note: Bleaching powder shall be measured and paid separately.
Supply of bleaching powder confirming to IS code and ISI marked brand complete all as specified and as directed by Engineer-in-charge.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 of 60 mm thickness of M-35 grade with grey cement and pigment including dismantling & removing old unserviceable paver blocks, complete all as per specified and as directed by Engineer-in-charge.
M&L for for sand cushioning layer 40m thick over sub baqse for fixing of interlocking tiles spread levelled to reqd level complete all as specified and directed by Engineer-in-charge.
M&L for brocken bricks for Loose filling with aggregates (broken bricks) of gauge 80 to 150 mm in soakage pits, soakage wells, complete all as per specified and as directed by Engineer-in-charge.
M&L for cleaning of cast iron pipe 100mm dia (internal) by rodding/pumping carefully from water closet to first manholes/inspection chamber or cleaning eye and removing all blockage in pipe lines and well flushing with water including making good of leakage in joint wherever required in cement mortar (1:2) complete all as specified and as directed by Engineer-in-charge.
M&L for cleaning of salt glazed stone ware (SGSW) sewage pipe line 150 mm dia (internal) by rodding/pumping between intermediate/1st manholes to manholes or between manholes to septic tanks or between septic tank to soak pits to remove all blockage and well flushing with water including making good of leakage in joints wherever required in cement mortar (1:2) complete all as specified and as directed by Engineer-in-charge.
M&L for cleaning of salt glazed stone ware (SGSW) sewage pipe line 100 mm dia (internal) by rodding/pumping between intermediate/1st manholes to manholes or between manholes to septic tanks or between septic tank to soak pits to remove all blockage and well flushing with water including making good of leakage in joints wherever required in cement mortar (1:2) complete all as specified and as directed by Engineer-in-charge.
M&L for cleaning of blocked WC by using vaccum pump including opening & refixing/CI cover bend and branch pieces and finally cleaned with water, complete all as specified and as directed by Engineer-in-charge.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed by Engineer-in-charge.
M&L 15mm thick rendering in CM (1:4) on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:3), mixing with water proofing compound @2% by weight of cement consumed and surface finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. Note: WPC shall be measured and paid separately as supply only under relevent item.
M&L for concrete bed 1:3:6 type C2 (40 mm graded stone aggregate) to 100 mm dia. drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as per specified and as directed by Engineer-in-charge.
M&L for concrete bed 1:3:6 type C2 (40 mm graded stone aggregate) to 150 mm dia. drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as per specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S Rajkamal Enterprise
M/s SHARMA BUILDERS & ENGINEERS
MUKUL CHOUDHURY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .