Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PLOT 26 3RD FLOOR MANAK VIHAR DELHI 92 | NEW DELHI | NEW DELHI | DELHI | 110092 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical Due to not conforming TE terms and conditions |
Tender Value
Refer Docs
EMD Value
₹94,500
Closing Date
2 Nov 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DIGP GC CRPF GURUGRAM
DIGP GC CRPF GURUGRAM
AS PER TE/ BOQ
2020_CRPF_592646_1
B.V-1/2020-21-Bldg- GC-GGM
Open Tender
Civil Works
Works
40 days
GC, CRPF, GURUGRAM HARYANA
AS PER TE
10 documents required · 10 mandatory
₹0
₹94,500
12 Nov 2020
23 Oct 2020
3 Nov 2020
23 Oct 2020
2 Nov 2020
23 Oct 2020
23 Oct 2020 - 28 Oct 2020
180 days
Earth work in excavation by mechanical means (Hydraulic excavator) / manual…………………………….. excavated soil as directed, within a lead of 50 m. (Details as per Appendix - A of NIT) 1.1) - All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 2.1) - 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
SH- REINFORCED CEMENT CONRETE WORK - 3.11) - Centering and shuttering including strutting, propping etc. and removal of form for : 3.12) Foundations, footings, bases of columns, etc. for mass concrete.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Steel reinforcement…………………. position and binding all complete up to plinth level. (Details as per Appendix A of NIT) 3.21) - Thermo-Mechanically Treated bars.
Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. 3.3) - Thermo-Mechanically Treated bars.
Providing and laying in position ready mixed M-25 grade concrete …………………...content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). (Details as per Appendix A of NIT) 3.41 ) - All works upto plinth level
All works above plinth level upto floor V level
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 4.1)- Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common………... to floor V level in all shapes and sizes in :(Details as per Appendix A of NIT) 5.1) -Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).
12 mm cement plaster of mix : 7.1 ) -1:6 (1 cement: 6 coarse sand)
15 mm Cement plaster on rough side of Single or half brick wall of mix. 8.1) - 1:6 (1 cement: 6 coarse sand)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
62 mm thick cement concrete flooring ………………..cement slurry, but excluding the cost of nosing of steps etc. complete. (Details as per Appendix - A of NIT)
Providing and laying vitrified floor tiles……………………………..including grouting the joints with white cement and matching pigments etc., complete. ( Matt finish ) (Details as per Appendix - A of NIT) 11.1) - Size of Tile 600x600 mm
Structural steel work riveted,…………... approved steel primer all complete. (Details as per Appendix - A of NIT)
Providing and fixing precoated galvanised iron profile sheets …………………...excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Details as per Appendix - A of NIT)
Providing and fixing precoated galvanised ……………………………………. coat 15-18 microns using self drilling/ self tapping screws complete : (Details as per Appendix - A of NIT). 14.1) - Ridges plain (500 - 600mm)
Providing and fixing false ceiling at all height including providing and fixing of frame work …………………………………….. in Charge but excluding the cost of painting with : (Details as per Appendix - A of NIT). 15.1) - Fully Perforated Gypsum Plaster Board of -…………………...with NRC value not less than 0.60 sqm (Details as per Appendix - A of NIT)
Providing and laying Polished Granite stone flooring……………………….rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (Details as per Appendix - A of NIT). 16.1) - Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Designing, fabricating, testing, …………………………….. for all heights and all levels etc. including: (Details as per Appendix - A of NIT). 17.1) - (a) Structural analysis & design and preparation of …………………….including checking of all the structural and functional design (Details as per Appendix - A of NIT). 17.2) - (b) Providing, fabricating and supplying and fixing panels…………………….as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (Details as per Appendix - A of NIT). 17.3) - (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised …………………………. with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. (Details as per Appendix - A of NIT)
Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately).
Providing and fixing 12 mm thick frameless ………………... fixing required door fittings, all complete as per direction of Engineer-incharge. (Details as per Appendix - A of NIT)
Providing and fixing 12 mm thick toughened glass for Windows……………….. Engineer-incharge (Door handle, lock and stopper etc.to be paid separately). (Details as per Appendix - A of NIT)
Providing and fixing Door handle, lock etc.for 07 nos. Windows
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin-charge 22.1 Extrucded sanction profile size 42.50 mm
supplying and fixing Man hole lid with frame made with GI and all accessories
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : - 23.1) - Water thinnable cement primer.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with 100% Premium acrylic emulsion paint………………. of required shade (Company Depot Tinted) with silicon additives. (Details as per Appendix - A of NIT). 25.1) - New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
WIRING IN STEEL AND PVC CONDUIT --Wiring for light point/ fan point/ exhaust fan point………………..with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Details as per Appendix - A of NIT). 26.1) - Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 29.1) - 5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. 32.1) - 3 Module (100mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 33.1) - 3 Module
6 Module
8 Module
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing suitable Airconditioner Industrial socket with 32 amps MCB inbuils with required accessories and Iron box
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 37.1) - 100 A, 16 KA,TPMCCB
Supplying and fixing following way, ………………. painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Details as per Appendix - A of NIT). 38.1) - 8 way (4 + 24), Double door
Providing and fixing of 12" x 12" LED light 20 watt with all fittings.
Providing and fixing of 5" x 5" LED light 9 watt with all fittings.
Strip light moulded tyoe water proof half white colour with required regulator and connectors
Providing anf fixing of designer Ceiling fan with all fittings.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 43.1) - Above 35 sq. mm and upto 95 sq. mm
Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 44.1) 450 mm dia. R.C.C. pipe
Providing and laying and shifting existing GI pipe lines with different dia 19 - 75 mm with required accessories as per site engineer / site incharge direction
SHIVALIK ENTERPRISES
A.K.G. Associates
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .