Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹37.3 L+₹4.3 L (13.2%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹39.1 L+₹6.1 L (18.6%)Rejected-Finance NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹43.1 L+₹10.2 L (30.9%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹44.5 L+₹11.5 L (35.0%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
14 Jun 2024, 6:00 pmClosed
LT COL CHANDRAKANT JOSHI
DRDO Complex, CV Raman Nagar PO, Bangalore 560 093
REPAIRS REPLACEMENT OF STREET LIGHTS PATHWAY LIGHTS GARDEN LIGHTS FLOOD LIGHTS AND CONNECTED WORKS AT PHASE II PHASE III CASDIC RTC DSC LINES GE OFFICE COMPLEX CDA RD AND GTRE UNDER GE I RD EAST BANGALORE
2024_MES_654509_1
8488/E8
Open Tender
Civil Works
Item Rate
270 days
GE I R AND D EAST BANGALORE
CLASS D CATEGORY b(i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D EAST BANGALORE
₹94,000
Yes
20 Sept 2024
17 May 2024
21 Jun 2024
17 May 2024
14 Jun 2024
1 Jun 2024
17 May 2024 - 31 May 2024
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying cables / poles foundation / stay assembly and getting out in hard / dense soil all as directed by Engs-in -charge.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed.
Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc. 25cm thick all as specified all as directed.
Material and labour for sand cushioning to under ground cable providing with a layer of 8cm thick before laying the cable and 15 cm thick after laying the cable complete all as specified and as directed. NOTE :- Punned thickness only will be measured for the purpose of payment.
Material and labour for common burnt clay building bricks sub class 'B' laid in trenches over sand cushioning for protection of UG cable in trenches complete all as specified and as directed.
Material and labour for un- reinforced pre cast concrete covers, class LV type 250mm x 150mm x 40mm size factory made for cable protection complete all as specified and directed.
Cutting of bituminous road / floor for laying of pipe / cables not exceeding 1.5 meter wide and not exceeding 1.5 meter deep including refilling / with material and watering, well ramming / compacting and making good with PCC (1:2:4), type B-1, 100mm thick complete all as specified and as directed. NOTE :- PCC shall be measured separately.
Material and labour for Plain Cement Concrete, (1:3:6), type C1, using 20 mm graded stone aggregate for making good the disturbed portion of road / floor / platform etc., including form work compaction etc all as specified and as directed.
Material and labour for laying, jointing and testing XLPE insulated, armoured heavy duty under ground electric cable with stranded aluminium conductor 1100 voltage grade cross-sectional area 50 sq.mm 3.5 core complete connection with proper through cable lugs including taking out / down old existing unserviceable LT UG Cable complete all as specified and directed . NOTE :- Excavation, sand cushioning and bricks shall be measured and paid separately under respective items of Schedule.
All as per Sl Item No. 9 above but of size 35 sq.mm, 3.5 core all as specified and as directed
All as per Sl Item No-9 above but of size 25 sq.mm 3.5 core all as specified and as directed
All as per Sl Item No -9 above but of size 16 sq.mm 4.0 core all as specified and as directed
All as per Sl Item No- 9 above but of size 10 sq.mm 4.0 core all as specified and as directed
All as per Sl Item No- 9 above but of size 10 sq.mm 2.0 core all as specified and as directed
Material and labour for GI pipe 40mm dia light grade, for road crossing / on wall / on pole for cable protection complete all as specified and directed.
All as per Sl Item No 15 above but of size 50 mm dia all as specified and as directed
Fixing only LED street light /flood light fittings of any rating / wattage including complete connection with fixing arrangement all as directed and specified by Engr in charge including taking down all as specified and as directed Note : Street light /flood light fitting will be issued under schdule 'B' free for fixing.
Laying only, jointing and testing XLPE insulated, armoured heavy duty under ground electric cable with stranded aluminium conductor 1100 voltage grade any rating /capacity including complete connection with proper through cable lugs including taking out/down old existing unserviceable LT UG Cable complete all as specified and directed. Note : LT XLPE Cable will be issued under schdule 'B' free for fixing only. Note: Excavation, sand cushioning and bricks shall be measured and paid separately under respective items of BOQ.
Material and labour for LT underground cable straight through joint heat shrinkable of size 16 to 35 sq.mm 3.5 Core complete all as specified and directed by Engr-in-Charge.
Material and labour for LT underground cable straight through joint heat shrinkable of size 50 to 95 sq.mm 3.5 Core complete all as specified and directed by Engr-in-Charge.
Dismantling of old steel tubular pole/RCC pole of any size with necessary disconnection of electric wire, demolition of concrete foundation including excavation, earth work as required and removing the same from site complete all as specified and as directed.
Material and labour for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31(9.0 metre long) including painting with two coats of synthetic aluminium paint complete all as specified and as directed. NOTE :- Execuation in PCC will be measured and paid seperately.
Material and labour for Plain Cement Concrete 1:3:6, type C2 (using 40 mm graded stone aggregate) for pole foundation including compaction etc all as specified and directed by Engineer-in-Charge.
Material and labour for Plain Cement Concrete 1:2:4, type B1 (using 20 mm graded stone aggregrate) for pole coping including form work compaction etc all as specified and directed by Engineer-in-Charge.
Material and labour for painting on existing LT Steel Pole 9 mtr long above the PCC foundation/coping surface including removing dust and painting with aluminium paint including cross arm bracing supports, clamp, back plates etc and all other MS structure including preparation of surfaces complete all as specified and as directed.
Material and labour for painting on existing LT Steel Pole 1.5mtr to 3mtr long above the PCC foundation/coping surface including removing dust and painting with aluminium paint including cross arm bracing supports, clamp, back plates and marking of pole No in synthetic enamel black paint of minimum height 40mm all other MS structure including preparation of surfaces complete all as specified and as directed.
Material and labour for painting of GI pipe suitable for post top latern of any type / size with one coat of existing paint and cleaning the PCC area by brush and two coat of white wash after minor repair in the bottom portion complete all as specified and as directed by Engr in charge. NOTE :- If PCC required then measured and paid separately.
Material and labour for repairs / maintenance of the street light fittings / High bay light fittings/Flood light fittings on pole or building / Workshop (at any height) by replacing the spares as per site requirement complet all as specified and as directed. NOTE :- (i) Replacement of accessories shall be measured and paid separately under relevant items of BOQ, no extra cost will be paid to the contractor for T&P and tradesmen as required. (ii) Taking down the fitting as required for maintenance for cleaning or minor repairs such as replacement of screws, wires including taking down etc., deemed to be included in the rate quoted. (iv) The contractor shall attend repairs with in 48 hours of intimation of complaint to him by concerned JE, failing which penality of Rs 250/- per day will be levied for non complianceof time limits indicated. (v) Quoted rate is deemed to be included the charges of necessary boom lift.
Material and labour for LED driver suitable for LED street light / flood light fittings (as requirement at site) of capacity upto 50 Watts of existing make complete as directed and specified by Engr in charge.
Material and labour for LED driver suitable for LED street light / flood light fittings (as requirement at site) of capacity upto 70 to 150Watts of existing make complete as directed and specified by Engr in charge.
Material and labour for LED driver suitable for LED street light / flood light fittings(as requirement at site) of capacity upto 150 to 250 Watts of existing make complete as directed and specified by Engr in charge.
Taking down the High mast light fitting safely electrically /manually from the pole at site and cleaning the entire fitting after minor repairs, checking of all electric connections, remove the old unserviceable LED light fitting from the pole and replacement of the driver (as required at site) after replacement of driver complete checking the connections, refixing the same complete all specified and as directed. NOTE :- (i) Minior repairs and spares are deemed to be included in the quoted rates. (ii) If driver replacement is necessarythe same will be measured and paid separately.
Material and labour for replacement of LED street light fitting 35 Watt 230 V AC outdoor type with new generation energy saving and environment friendly long life LED street light made up of pressure dia cast aluminium housing with high power LED as a light source with driver, and IP 65/66 protection complete with all fixing arrangement complete all as directed and specified
Material and labour for replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with all fixing arrangements complete as directed and specified.
Material and labour for replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with all fixing arrangements all as directed and specified
Material and labour for replacement LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with all fixing arrangement complete as directed and specified
Material and labour for replacement LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp with all fixing arrangement complete as directed and specified
Material and labour for replacement LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp with all fixing arrangement complete as directed and specified
Material and labour for replacement LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp with all fixing arrangement complete as directed and specified
Material and labour for replacement LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp with all fixing arrangement complete as directed and specified
Material and labour for replacement post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete with all fixing arrangement complete as directed and specified
Material and labour for replacement of post top lantern light fitting with LED 40 Watts energy saving environmental friendly, long life aesthetically designed die cast aluminium landscape luminaire for download lighting with high power LED as light source with all accessories and complete fixing arrangement with connection and painting of GI pipes with two coats of gray paint complete as directed and specified
Material and labour for wiring in rigid PVC conduit with conduit accessories, with 2 run of 2.5 sq.mm single core PVC insulated copper wire complete secured to LT pole surface from junction box to street light fitting complete connected all as specified and directed.
Material and labour for fixing or passing, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of standard conductor 6 sq. mm single core nominal cross section in service connections of complete connection all as directed and specified by Engr in charge.
Material and labour for replacement of unserviceable MS clamp with new clamp made out of MS flat iron 25 x 5mm including fixing nuts bolts, washers etc and painting with two coats of syntetic enamel paint over a coat of red oxide primer complete all as specified and directed
Material and labour for replacement of street light bracket made out of 40mm dia GI Pipe medium grade of 1.5 m long bent to shape with all fixing arrangement complete all as specified and directed by Engr in charge.
Material and labour in replacement for pole mounted junction box (street light boxes) Top hinged Door fixed with hinges on top of size 205mm x 255 x 112mm made out of FRP sheet with weather proof, locking arrangements vertical operated with one No. 6 /10 Amps MCB SP, EPOXY. Technical connector upto 8 ways, fixed on pole with 25mm x 3mm MS flat iron clamps and painting with two coats of synthetic enamel paint over one coat of red oxide primer for fixing clamps all as specified and directed
Material and labour for replacement of MCB SP 5-32Amps 230 Volts single phase all as specified complete all as specified and as directed
Material and labour for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, bigures and conventional shull and bones in signal red colour and fixed with MS clamps, bolts & nuts of approved size for LT 20 x 15 CM complete all as specified.
Material and labour for finding out the cable fault of any size of cable upto 11 KV underground cable (HT and LT and of any capacity of cable with the help of cable fault locator mounting on vehicle and with nessary disconnection of cable from two ends and making connection by joining after repairs and having the following items with electrician at site to find fault of up to length of 10 KM cable complete all as specified and directed by Engr-in-Charge with help of the following accessores- (a) Surge Generator with accessories (b) Head Phone (c) Pin Point Set T-505 with accessories (d) Earthing cable with clamp (e) Cable fault Locator T-905 with accessories (f) TC-808 with accessories (g) Soldering Iron/wire/capacitor unit/capacitor connecting cables/ power cable/nose plier. Notes: Excavation for the cable fault shall be done by the contractor by his own arrangement.
Material and labour for opening of all connection of electric power cable of any size from the electrical panel , cleaning and replacing of aluminium lugs of existing cable of size upto 400 sq.mm upto 20 Nos in each panel and checking of all electrical wiring of panel and servicing of bus bar strip changing etc and tightening of nuts and bolts and making all connection as per original including testing for entire satisfaction of Engr-in-charge.
Material and labour for repairs to LT panel board complete with neccessary welding works to doors, replacement of unserviceable hinges and old nut bolts and painting with one coat of synthetic enamel paint of approved colour internally & externaly all as specified and directed by Engr-in-Charge
Material and labour in repairs Moulded Case Circuit Breakers for Distribution Network with thermal magnetic release type DPX 250, 3 pole 100 Amps capacity, 16 KA rupturing capacity in existing panel board including modification on existing panel if required, necessary connectioning with copper strips/suitable size of copper conductor wire from bus bar, provison of suitable size of copper lugs as per the out going cable complete as directed and specified
All as per Sl Item No 53 above but 3 pole 160 Amps 36 KA complete all as specified and directed
All as per Sl Item No 53 above but 4 pole 200 Amps 36 KA complete all as specified and directed
All as per Sl Item No 53 above but 4 pole 250 Amp 36 KA complete all as specified and directed
All as per Sl Item No 53 above but 4pole 400 Amps 36 KA complete all as specified and directed
Material and labour for steel MCCB enclosure on wall suitable for fixing of MCCB of 3 pole / 4 pole cap upto 250 AMP all as specified and directed by Engr-in- charge
Material and labour for steel MCCB enclosure suitable for fixing of MCCB of 3 pole/4 pole cap upto 315 Amp to 630 Amp all as specified and directed by Engr-in- charge
Material and labour for servicing of 415 Volt electrical panel indoor /outdoor type for cleaning of dust particle inside the panel like MCCB , relay/contactor with help of blower etc and tightening of all electrical connection including complete testing and replacement of burnt lugs etc all as specified and directed.
Material and labour for disconnecting burnt LT Cable of size 50 sq.mm x 3.5 core from MCCB/Main switch etc and cleaning the bus bar and removing carbon and rusted nuts bolts etc complete and reconnecting the LT cable after replacement of amuminium lugs, glands etc all as specified and directed.
All as per Sl Item no. 61 above but UG Cable of 35 sq.mm x 3.5 core all as specified and directed.
All as per Sl Item no. 61 above but UG Cable of 25 sq.mm x 3.5 core all as specified and directed.
All as per Sl Item no. 61 above but UG Cable of 16 sq.mm x 4 core all as specified and directed.
All as per Sl Item no. 61 above but UG Cable of 10 sq.mm x 4 core all as specified and directed.
Material and labour for copper earth continuity main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit of size 20 x 3 mm all as specified and directed.
Material and labour for earthing complete with galvanised iron plate electrode 600 x 600 x 6.00mm thick GI earthing lead burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with the top edge of the plate at a depth not less than 1.5 mtr from below normal GL, connected to and including Galvanised iron strip 32x6 mm as earthing lead by means of nuts, bolts, washers, checknuts of galvanised iron and connected to earthing test point all as shown in electric plate No. 3 of SSR Part l of 2010 and as specified or indicated and testing on completion including excavation / earth work in any type of strat PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement cioncreat (1:2:4) type B1 (Reinforced with welded steel wire fabric (XPM)) weight not less than 4 Kg/sqm,cast iron frame, funnel with wire mesh, including GI earth strip with GI protection pipe of 40mm medium grade 7.5 meter long etc complete and testing on completion all as specified and directed. NOTE :- (i) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (ii) GI strip above 7.5m will be measured and paid seperately. (iii) Earth resistance not exceeding 1.0 ohm.
Material and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm galvanised iron or steel wire all as specified and directed.
Material and labour for installing 300mm width x 50mm depth x 2mm thickness size of perforated hot dipped Galvanised Iron cable tray (Galvanisation thickness not leass than 50 microns) with perforation not more than 17.5% inconenient sections, jointed with connectors, suspended from the ceiling with GI suspenders including GI Bolts & nuts as required all as specified and directed. NOTE :- (i) All necessary fixing/ connecting arrangements of nut, bolt, MS rod, to be provided by the contractor without any extra cost ot Govt. (ii) Quoted rate is to be deemed the charges of necessary boom lift.
Material and labour for MES sub station boards of size 4 x 3 feet with stainless steel 50mm dia pipe support ground aprox 6 feet hight errected in earth with cement concrete, including excavation as required, with superior quality ACP boards with radium/reflective blue letters with maxium 70 letters with maxium size in English with stainless steel frame work complete with fixing of LED fittings inside the board including the complete wiring work with complete connection all as directed and specified by Engineer - in - charge. NOTE :-- Display letter for the boards will be ' name of installation' and "location" all as directed.
Material and labour for one side retro reflective sign boards, made of 3mm thick colured ACP (Aluminium composite panel), including writing/pasting of words/figures/numbers/logos of any size/ pattern & height with self adhesive reflective transparent prismatic engineering grade tape (Radium tape) of approved make complete including stainless steel frame work all as specified and as directed. Note:- (i) The words/figure /number/ logos shall be computer aided machine cut. (ii) Earthwork & excavation if necessary will be measured and paid for under respective items. (iii) Quoted rate shall include for necessary scaffolding etc for fixing of board at required heights.
Material and labour for MES sub station boards of size 4 x 2 feet with SS 50mm pipe support ground aprox 6 feet hight errected in earth with cement concrete, including excavation as required, with superior quality ACP boards with radium/reflective blue letters with maxium 70 letters with maxium size in English with stainless steel frame work complete all as specified by directed by Engineer - in - charge. Note :- Display letter for the boards will be ' name of installation' and "location" all as directed.
Material and labour for Installation Notice board of size 5 x 4 feet (as per sample) of SS cover in out side including fixing on wall all as directed and specified by Engr in charge.
Material and labour for Installation of Key box 2 x 2 feet (as per sample) of wooden and for the proper locking arrangement and fixing of glass in front side including fixing on wall all as directed and specified by Engr in charge.
Material and labour for street light control board / box of size 0.50 x0.50 x 0.20 m made out of 1.60 mm thick MS sheet fixed / mounted on pole by means of 2 Nos of FT clamps of size 25 x 3 mm comprising the following enclosures and connecting with suitable size of copper cable all as directed comprising of following:-. (a) MCB,TPN, 40 Amps -01 No. (b) Timer switch, electronic, 3Pole/230V -01 No (c) Contactor , 32 Amps 415 volts -01 No. MAKE :- Code No. TL040AB0 make of Indo Asian or techno commercially equivalent makes specified in PS
Material and labour for PVC Moulded LED strip with water proof and IP 65 protection variant and bendable material of the streep design in pole (Triple colour) as Indian flag pattern/colour makes it ideal for flexible decoration including all fixing arrangement in pole as directed and specified by Engr in charge.
Material and labour for one driver for connection of LED strip suitable for fixing all electric connection with all fixing arrangements as directed and specified by Engr in charge.
Material and labour for digital time switches 1 Module, 24 hours program, programmable every 15min, backup of 6 years, current capacity 16A, with 1 changover (1 CO) suitable for fixing all electric connection with all fixing arrangement as directed and specified by Engr in charge.
Material and labour for digital time switches 3P Module, 24 hours program, programmable every 15min, backup of 6 years, current capacity 16A, with 1 changover (2 CO) suitable for fixing all electric connection with all fixing arrangement as directed and specified by Engr in charge.
Material and labour for replacement of bollard fitting with LED energy saving, environmental friendly, long life aesthetically designed die cast aluminium landscape luminaire for download lighting with high power LED as light source of 10 Watts with all accessories complete including dismantling old one specified and directed by Engr-in-Charge.
Material and labour for very High efficiency round High Bay LED fittings 120 watt, 220 V AC in PDC housing complete with driver, holders and LED lamp suitable for industrial purpose including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Material and labour for dismantling of existing LT over head line (ACSR conductor) from poles including insulators, cross arms, brackets, clamps nuts & bolts etc and deposited to MES Store yard complete all as specified and as directed.
Material and labour for dismantling of existing stay assembly complete including breaking of concrete complete all as directed and as specified
Material and labour for installation of lithium based energy highly efficient integrated sloar street light 20 watt in FRP body encases solar PV Panel 20W (Orient Solar Street Light), LED Life 50000 Hrs, PIR Sensor - Yes, IP65, Monocrystalline, lithium battery 12.88V, 21AH with inbuilt BMS, High brightness W-LED (120 lm/watt) lamp, CRI 80, color temprature 6000K-6500K, Micro controller based charge controller based charge controller cum driver with automatic dimming function, Dusk to down Operation, LUX output 15-18 (from 6-7 mtr height), working temperature (-) 10C to (+) 55C, weight 6-7 Kgs, with adjustable MS Clamp suitable for pole/wall mounting protections with GI Iron pipe 65mm, 5 mtr high excluding 1 mtr planting depth with aluminium painted foundation of pole with PCC 1:3:6 using 20mm graded aggregate of size 1120 x 305x 140 mm deep all as specified and directed.
M/S Sneha Enterprises
ARUNOTHAYA TRADERS
V.R.Enterprises
Vishwas Enterprises
GKR and CO
SRI LAKSHMI ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .