Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹10.5 L+₹65,421 (6.66%)Rejected-Finance | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | Rejected-Technical RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | - | Rejected-Technical No |
Tender Value
₹11 L
EMD Value
₹22,000
Closing Date
16 Jan 2020, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
REPAIR/ REPLACEMENT OF CEILING FANS EXHAUST FANS FRESH AIR FAN WALL MOUNTED FANS GEYSERS SOLAR WATER HEATERS AND CONNECTED WORKS AT TARAPORE ENCLAVE UNDER AGE E/M (S) OF GE (SOUTH) DELHI CANTT 10
2019_MES_294511_2
GE/DS-66/2019-20
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹22,000
Yes
4 Mar 2020
16 Dec 2019
18 Jan 2020
16 Dec 2019
16 Jan 2020
30 Dec 2019
17 Dec 2019 - 27 Dec 2019
Amount
Taking down of ceiling fan/ Fresh Air Fan / Exhaust fan/Wall Mounting Fan ,dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation and testing complete all as specified and directed by Engineer-in-Charge. Note:- Rewinding will be measured and paid separately under respective item of this Schedule.
M&L for Rewinding of ceiling fan 1200/1400 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper, applying of varnish drying of varnish and assembling of fan including replacement of gun metal bush and Shaft where ever required complete all as specified and directed by Engineer-in-Charge. Note:- Gun metal bush and Shaft will be measured and paid separately under respective item of this Schedule.
M&L for Rewinding of Exhaust Fan / Fresh Air fan upto 200 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper, applying of varnish drying of varnish and assembling of fan including replacement of gun metal bush & shaft where ever required complete all as specified and directed by Engineer-in-Charge. Note:- Gun metal bush and shaft will be measured and paid separately under respective item of this Schedule.
M&L for Rewinding of Exhaust Fan / Wall Mounted fan upto 400 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper, applying of varnish drying of varnish and assembling of fan including replacement of gun metal bush & shaft where ever required complete all as specified and directed by Engineer-in-Charge. Note:- Gun metal bush and shaft will be measured and paid separately under respective item of this Schedule.
S&F in replacement for ceiling fan/ Exhaust fan Ball bearing of suitable size & model (as per sample) complete all as specified and directed by Engineer-in-Charge. Make:- NBC/ SKF
S&F in replacement for fan condenser 2.0 Mfd complete all as specified and directed by Engineer-in-Charge. Make :- Epcos/Tibcon/Havells
S&F in replacement for fan condenser 2.5 Mfd complete all as specified and directed by Engineer-in-Charge. Make :- Epcos/Tibcon/Havells
S&F in replacement for fan condenser 3.15 Mfd complete all as specified and directed by Engineer-in-Charge. Make :- Epcos/Tibcon/Havells
M&L for painting of ceiling fans complete in situ with one coat of synthetic enamel piaint by spraying after cleaning all dust complete all as specified and directed by Engineer-in-Charge.
M&L for Cleaning , de-scaling and greasing of Exhaust fan with louvers,Fresh Air Fan and Wall mounted Fan with necessary cleaning material complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of MS louvers suitable for exhaust fan of size 300 mm sweep as per sample complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of exhaust fan blades/ Fresh Air Fan blades for size upto 300 mm sweep as per sample complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of Wall mounted fan blades for size upto 400 mm sweep as per sample complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of Ceiling fan blades (Set of 03) heavy duty suitable for 1200mm / 1400 mm sweep complete all as specified and directed by Engineer-in-Charge.
S&F PVC canopy for ceiling fan of size 1200/1400 mm as per sample complete all as specified and directed by Engineer-in-Charge.
Taking down geyser 25 ltrs capacity of any make, opening up complete for inspection descalling by chemical treatment of internal tank , themrostat pipe, base plate assembly, carrying out minor repairs including replacement of gaskets, testing and refixing in position including making electrical and water connection complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for heating element 1.5 KW for any make of geyser of 25 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge. Make:- Micronking/Theeta/Standard
S&F in replacement for thermostat ( 11 inch Long) for 25 ltrs capacity geysers complete all as specified and directed by Engineer-in-Charge. Make:-Micronking/Theeta/ Standard
S&F in replacement for indicating lamp round / flat type as required for geyser 25 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for safety valve ISI marked for geyser 25 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for safety plug for geyser 25 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for CP connection 15mm x 450 mm long complete with 2 Nos brass/CP nuts and washers etc suitable for geyser 25 ltrs capacity as per sample complete all as specified and directed by Engineer in Charge.
S&F in replacement for PVC connection with brass nipple 15 mm x 450 mm long for geyser 25 ltrs capacity as per sample complete all as specified and directed by Engineer in Charge.
S&F in replacement for base plate geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket for any make of geyser of 25 litres cap as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for 25 Ltr inner stainless tank suitable for 25 Ltr storage water heater complete all as specified and directed by Engineer-in-Charge.
S&F FR PVC Sheathed Round , Copper conductor (Flexible) industrial cable , 1100 Volts , conforming to IS: 694 of size 2.5 Sqmm 3 core for connecting geyser, including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.
M&L for welding /brazing the inner shell made out of stainless steel /copper sheet for geyser 25 ltrs capacity of any make and make the shell water tight including testing complete all as specified and directed by Engineer-in-Charge. Note:- Taking down, de-scaling, replacement of rubber gasket and any minor repair involved will be measured and paid separatly.
S&F in replacement for Rubber gasket for Water heater (storage type) of any capacity complete all as specified and directed by Engineer-in-Charge.
M&L for outer body suitable for 25 Ltrs Water storage heater made of MS Sheet complete as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L for Top & Bottom cover body suitable for 25 Ltrs Water storage heater made of MS Sheet as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for MS fastner bolt 8 mm dia and upto 150mm long for fixing Geyser/Exhaust Fan with nuts and washers complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Metal Clad Socket 240 Volts , 20 Amps, 2P + E, upto 20 Amps capacity of Ovory or blue cap colour complete all as specified and directed by Engineer-in-Charge. Make:- Legrand / Indo Asian / C&S
S&F in replacement of Metal Clad Plug Top 240 Volts , 20 Amps, 2P + E, upto 20 Amps capacity of Ovory or Grey colour complete all as specified and directed by Engineer-in-Charge. Make:- Legrand / Indo Asian / C&S
S&F in replacement of Single Phase Motor Starter Switch 16/20/25 Amps for AC's Point complete all as specified and directed by Engineer-in-Charge. Make:- Precision , Cat No- 0901/0902/0903 or Equivalent in CrabTree/Cona
Taking up and down 15 mm bore steel water tubing including connections complete all as specified and directed by Engineer-in-Charge.
Taking up and down 20 mm bore steel water tubing including connections complete all as specified and directed by Engineer-in-Charge.
Taking up and down 25 mm bore steel water tubing including connections complete all as specified and directed by Engineer-in-Charge.
S&F for galvanised steel water tubing medium grade of size 15 mm dia with all GI fittings laid in trenches , wall , ceilings and floor complete all as specified and directed by Engineer-in-Charge.
S&F for galvanised steel water tubing medium grade of size 20 mm dia with all GI fittings laid in trenches , wall , ceilings and floor complete all as specified and directed by Engineer-in-Charge.
S&F for galvanised steel water tubing medium grade of size 25 mm dia with all GI fittings laid in trenches , wall, ceilings and floor complete all as specified and directed by Engineer-in-Charge.
All as per item No. 38 here-in-before but fixing only.
All as per item No. 39 here-in-before but fixing only.
All as per item No. 40 here-in-before but fixing only.
S&F in replacement for Solar Flat Plate Collector of 100 LPD of 2.0 mm thick SS304 with heat Exchanger all as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for Toughned Glass of Flat Plate Collector of Solar water of capacity 100 LPD all as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L for De-Scaling of Solar Flat Plate Collector by Chemical process upto capacity 300 LPD complete to clear the deposits of temperory hardness in sides of collector tubes including brazing of leaking joint all as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for old SS-304 Nuts and bolts 6 x 25 mm size all as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for Dead plug of Collector complete all as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for Gaskets of Collector complete all as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for Washers of Collector complete all as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for Ball valve of Size 20mm (NB) Bronze all as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for Ball valve of Size 25mm (NB) Bronze all as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L for Gas welding (TIG/Argon Welding) for leakage Joint of Hot water storage tank of Solar water tank of capacity 300 LPD / Flat plate collector including welding of broken stand of solar water tank all as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for Makeup tank of Heat Exchanger of Hot Solar water of capacity 300 LPD all as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L for descaling of solar water tank of 300 LPD capacity including descaling of heat exchanger and replacement of suitable CPVC pipes for hot and cold water from tank to collector and vice versa including replacement of sockets, unions, clamps, nuts, bolts and washers complete all as specified and directed by Engineer-in-Charge.
M&L for cleaning of cold water tank of capacity 500 to 1000 ltrs including replacement of broken tank covers complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Heating Element 2 KW complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Thermostat for Heating Element 2 KW complete all as specified and directed by Engineer-in-Charge.
M&L for Insulation of Hot water tank of capacity 200-500 Ltrs with thickness of insulation of 10 cm around the tank and aluminium sheet of thickness 24 SWG complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for Sheet metal enclosure for DB's (Double Door Type) when MCB's to be used , Single pole and neutral 8 Way with 200 Amps rated busbars , 240 voltssunk / flush to the wall complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for MCB SPN 63 Amps C curve including taking down Old MCB any type complete all as specified and directed by Engineer-in-Charge. Make : Legrand/ABB/Crabtree
S&F in replacement MCB SP 6 to 40 AMPs C curve including taking down Old MCB any type complete all as specified and directed by Engineer-in-Charge. Make : Legrand/ABB/Crabtree
Taking down old Submain wiring with conduits / battens of any type , keeping away from site and M&L for submain wiring of two runs of 6 Sqmm size for main cable and one run of 4 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn into and including electrical grade PVC conduit not less than 25 mm dia ISI marked with all accessories fixed concealed including cutting chases in brick/stone masinery for fixing conduit and making good to the disturbed surface of wall as per existing complete all as specified and directed by Engineer-in-Charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
M/S Malik Construction Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .