| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC | L1 | Accepted-AOC Tender Accepted | |
| 2 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹5.0 L
EMD Value
₹9,900
Closing Date
6 Apr 2022, 5:00 pmClosed
Project Engineer MPPHIDCL Bhopal Division-02
Project Engineer MPPHIDCL Bhopal Division-02 MPPHIDCL BHADBHADA RAOD BHOPAL
Work of HT and LT Line Shifting for Upgardation 300 to 500 Beds Hospital at Rajgarh.
2022_MPPHC_193293_1
15/2021-22
Open Tender
Electrical Works
Item Rate
30 days
Bhopal
AS PER NIT
4 documents required · 4 mandatory
₹2,000
Yes
₹9,900
Yes
6 May 2022
25 Mar 2022
8 Apr 2022
25 Mar 2022
6 Apr 2022
25 Mar 2022
Amount
Supplying and erection of HT/LT overhead line single length supporting complete with aligning and keeping it in truly vertical position including digging pit of required size filling with 1:3:6 cement concrete of 0.60 meter. dia of required length around the pole including muffing of 0.50 meter. from ground level as per specifications with 20 cm. thick base foundation providing and busying 15 mm dia G.I. pipe from bottom to 1.5 meters above ground level on pole refilling the pit including painting of pole with bitumen paint in bottom and one coat of red oxide and two coats of aluminum paint etc. complete as per specification. The depth of foundation shall be 1/6th of the length of pole. (a)H- Beam 152 x 152 mm 37.1 kg/meter weight 13meter long
Supplying and erection of HT/LT overhead line single length supporting complete with aligning and keeping it in truly vertical position including digging pit of required size filling with 1:3:6 cement concrete of 0.60 meter. dia of required length around the pole including muffing of 0.50 meter. from ground level as per specifications with 20 cm. thick base foundation providing and busying 15 mm dia G.I. pipe from bottom to 1.5 meters above ground level on pole refilling the pit complete as per specification. The depth of foundation shall be 1/6th R S joist 175X85mm 19.6kg/mtr 9.3 mtr long
Supplying and errection of stay set completed with stay rod, anchor plate, thimble, stay clamp, turn buckle etc. with stay wire strain insulator nut bolts as per specifications including concreting in required size and excavation in all type of soil Rocks and also foundations in cement concrete 1:3:6 complete of required size and other necessary materials complete as per specification. (A) Stay rod 20 mm with 7/3.15 mm stay wire
Supplying and errection of stay set completed with stay rod, anchor plate, thimble, stay clamp, turn buckle etc. with stay wire strain insulator nut bolts as per specifications including concreting in required size and excavation in all type of soil Rocks and also foundations in cement concrete 1:3:6 complete of required size and other necessary materials complete as per specification. (A) Stay rod 16 mm with 7/3.15 mm stay wire
Supplying and fixing of Angle/ channel/flat iron, V cross Arms reinforcement of RS joist/ flat iron fittings for overhead lines and poles such as cross arms/ bracket/ clamps/ stiffness for poles etc. all required steel work including' cutting to size making proper shapes drilling scan welding etc. including nuts & bolts plan & spring wisher and other necessary material including one coat of red oxide and two coat of aluminum paint etc. as required.
Supplying and fixing Polymer type 11 K.V. pin insulator with G.I. pin of approved make on existing pole or bracket with necessary materials and hardware complete as required.
Supplying and fixing polymer type 11 K.V. disc (strain) insulator of approved make on existing pole or bracket with necessary materials and hardware complete as required.
Supplying and drawing AAAC conductor of approved make with stringing, making off complete with binding at existing insulator, jointing , jump ring, billing off connecting, making 'D' loops connections etc. complete and clearing of obstacles (if any) as specified and directed. (A) AAAC Rabbit Conductor 0.075 Sq. Inch (80 sq.mm) aluminum or Equivalent .
Providing and fixing ear thing arrangement for H.T./L.T. poles with G.I. wire of 115 turn of 50mm dia. connection with bracket/ cross arm/ pole with 4mm dia. G.I. lead through 20 mm dia. G.!. Protection pipe of length from bottom of pole to 2 meter above ground level, packing of charcoal powder and salt as per specification including excavation of pit in all type of soil / rock etc. complete.
Supplying and fixing of danger/ caution Board as per specification with necessary materials complete for H.T. lines and other equipments as required.
Supplying and fixing 12x16 gauge barbed wire antidumping device around the existing H.T. pole and sub station poles for safety measures as per IE rules including all staples and all other necessary materials complete as per mpseb specification.
Supplying & drawing / laying of PVC insulated XLPE Aerial bunch power cable conductor H2/H4 grade Aluminium Solid/stranded confirming to IS-14255- 1995, Alu. Alloy insulated messenger 1100 volts grade cable of approved make in Air with necessary material as per specification ofrequired size as mentioned below– 3x50 Sq.mm, 1x16(St.Light), 1x35( Insulated neutral messenger)
Piercing Connecter type -I 1p/3p(main 16-50 Sqmm tap-off 16-50sqmm)
Piercing Connecter type -II (main 16-50 Sqmm tap-off 16-50sqmm)
Suspention Clamp For LT AB Cable
AB Cable Dead End Clamp (Galvanized) /tension Clamp
11 Kv AB Switch polymer Type 400Amp with Complete Fitting
Dismantling of existing steel pole, R.S. Joist, girder with bracket clamp insulator or stay from the cement concrete foundation and making the site clear by refilling the pit to ground level i/c transportation to required destination within township.
Dismantling of existing overhead ACSR, AAAC, GI, conductor and making the site clear i/c transportation to required destination within township.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .