| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 CrAccepted-AOC | ₹6.0 Cr Quoted ₹6.1 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹6.2 Cr+₹7.2 L (1.17%)Rejected-AOC | ₹6.2 Cr+₹7.2 L (1.17%) | L2 | Rejected-AOC NOT BEING LOWEST |
| 3 | L3₹6.4 Cr+₹32.3 L (5.27%)Rejected-AOC | ₹6.4 Cr+₹32.3 L (5.27%) | L3 | Rejected-AOC NOT BEING LOWEST |
| 4 | L4₹7.1 Cr+₹1.0 Cr (16.5%)Rejected-AOC NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹7.1 Cr+₹1.0 Cr (16.5%) | L4 | Rejected-AOC NOT BEING LOWEST |
| 5 | L5₹7.9 Cr+₹1.8 Cr (28.9%)Rejected-AOC | ₹7.9 Cr+₹1.8 Cr (28.9%) | L5 | Rejected-AOC NOT BEING LOWEST |
Tender Value
₹6.5 Cr
EMD Value
₹6.5 L
Closing Date
11 Mar 2024, 6:00 pmClosed
Chief Engineer Chennai Zone
HQ CE Chennai Zone, Island Grounds, Anna Salai, Chennai 600009
PROVN OF ADM BUILDINGS AND CLASS ROOMS INCL LABS AND LIBRARY AT RASHTRIYA MIL SCHOOL, BELGAUM
2023_MES_633395_1
88551/E8
Open Tender
Civil Works
Lump-sum
549 days
Belgaum
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Garrison Engineer Belgaum
₹6.5 L
Yes
12 Apr 2024
9 Jan 2024
13 Mar 2024
9 Jan 2024
11 Mar 2024
27 Feb 2024
Amount
Lumpsum price worked out by the tenderer for BUILDINGS / STRUCTURES as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for ROAD/PATH/CULVERT & HARD STANDING as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for RAIN WATER HARVESTING as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for DISMANTLING & DEMOLITION as listed in Schedule ‘A’ Part-X
SCHEDULE 'A' PART X (MISCELLANEOUS ITEMS) Note: This schedule is not pre-priced by MES
INTERNAL WATER SUPPLY
Supply and fix 15mm two way bib tap. Brass chromium plated, fancy type , with crutch or butterfly handle, suitable for CPVC pipe complete al as specified and as directed.
INTERNAL ELECTRIC SUPPLY
Material and labour for point wiring complete all as specified with 1100 Volts grade 1.5 Sqmm PVC insulated FRLSH unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking (for Phase, Neutral and Earthing) in and including non metallic PVC rigid conduit medium grade of size 19mm dia with all accessories concealed in wall / ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLSH unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including factory made modular metal flush boxes concealed in walls and modular white plate covers for mounting of modular switches/sockets/fan regulators etc complete all as specified for the following :
One light/ ceiling fan/ exhaust fan point controlled by one switch.
One three pin switch socket 5/6 amps outlet on independent board.
One three pin switch socket 5/6 amps outlet on same board.
One light point controlled by two 2 way switches.
One bell/buzzer point controlled by one bell push switch.
Material and labour for point wiring complete all as specified with 1100 volts grade 4.00sqmm PVC insulated FRLSH, unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking (for Phase, Neutral and Earthing) in and including non metallic PVC rigid conduit medium grade of size 19mm dia with all accessories concealed in wall / ceiling including continuous earth wire 4.00 Sqmm PVC insulated FRLSH unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including factory made modular metal flush boxes concealed in walls and modular white plate covers for mounting of modular switches/sockets 16Amps outlet on independent board complete all as specified.
Supply and fix LED lights fitting 1x 20W, 220V, AC decorative box type wall mounted LED Batten (1144x25x35mm) with powder coated white extruded aluminium housing with integrated electronic driver, and LED lamp all as per Cat No. ENDURALINEARNEOBS20WLED865SPCWH of Havells or technocommercially equivalent of other specified makes including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fix LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type, wall mounted LED batten (581x25x35mm) powder coated white extruded aluminium housing with integrated electronic driver holder and LED lamp all as per Cat No. ENDURALINEAR NEOBS10WLED865SPCWH of Havells or technocommercially equivalent of other specified makes including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fix LED square light fitting 15W, 220V AC, asthetically designed, 300x300x70mm flat panel for surface mounting Cat No : PLUTOSURFACE 1X1PLS15WLED840S of Havells or techno commercial equivalent of other specified makes including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed
Supply and fix 2ft x 2ft Surface mounted LED Luminaire, 36 Watts with white powder coated CRCA housing with LEDs surface luminaire to enhance the delight of occupants with front frame with classic design & glare free soft illumination flat white high transmission acrylic cover complete with all accessories as per Cat No : PLANOSUR2X2 PLS36WLED857S0720 of Havells or techno commercial equivalent of other specified makes including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed
Supply, fix, connecting and testing MCCB, Four pole, 100 Amps, 415 Volts, with breaking capacity 10KA, (lcs=50%lcu) with fixed TM setting, conforming to IEC 60947-II, suitable for isolation, fixed overload and fixed short circuit settings all as per Cat no. 830717 of Indoasian or techno-commercially equivalent of other specified makes etc, complete all as specified and as directed.
Supply, fix, connecting and testing factory made, prewired Vertical type distribution board, (MCCB DB) TPN, 4 way, having degree of protection IP 43-IK-09 with metal double door, 415 Volts, flush type made out of CRCA sheet metal, duly powder coated and conforming to IS 8623 with 250 Amps rated copper bus bar all as per Cat No.DHDLVDRWAOFO04 of Havells or 5077 45 of Legrand or 811893 of Indoasian or techno-commercially equivalent of other specified makes with common neutral link earth bar, din bar for mounting MCBs, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc as required complete concealed and fixed flush to wall and making good the disturbed surfaces etc., complete all as specified and as directed. Note: MCCBs and MCBs will be measured and paid separately.
Supply, fix, connecting and testing factory made, prewired Vertical type distribution board, (MCCB DB) TPN, 6 way, having degree of protection IP 43-IK-09 with metal double door, 415 Volts, flush type made out of CRCA sheet metal, duly powder coated and conforming to IS 8623 with 250 Amps rated copper bus bar all as per Cat No.DHDLVDRWAOFO06 of Havells or 5077 46 of Legrand or 811894 of Indoasian or techno-commercially equivalent of other specified makes with common neutral link earth bar, din bar for mounting MCBs, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc as required complete concealed and fixed flush to wall and making good the disturbed surfaces etc., complete all as specified and as directed. Note: MCCBs and MCBs will be measured and paid separately.
EXTERNAL WATER SUPPLY
Construction of valve chamber of size 1000 x 1000 mm (Internal size) 900 mm deep for 150mm dia sluice valve with 200mm thick PCC block masonary walls built in CM 1:4 over 100 mm thick foundation concrete in PCC 1:4:8 type D2, (Using 40 mm graded coarse aggregate) with 100 mm off set, 15mm thick complete internal plaster and external plaster up to a depth of 15 cm below GL in CM (1:6), 3 mm thick MS sheet cover, double door welded to 40 mm x 40 mm x 6mm MS angle frame fixed with hold fasts in PCC 1:2:4 type B1 coping 50 mm thick in PCC (1:2:4) type B-1, 20mm x 6mm flat iron hinges with locking arrangement including lock 65mm, brass and keys (Godrej/Shell), MS handles and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any type of soil /soft disintegrated rock and disposal of surplus soil to a distance not exceeding 50 Mtr complete all as specified and directed
Construction of valve chamber of size 450 x 450 mm (Internal size) 450 mm deep for 50mm dia gate valve with 200mm thick PCC block masonary walls built in CM 1:4 over 100 mm thick foundation concrete in PCC 1:4:8 type D2, (Using 40 mm graded coarse aggregate) with 100 mm off set, 15mm thick complete internal plaster and external plaster up to a depth of 15 cm below GL in CM (1:6), 3 mm thick MS sheet cover, double door welded to 20 mm x 20 mm x 6mm MS angle frame fixed with hold fasts in PCC 1:2:4 type B1 coping 50 mm thick in PCC (1:2:4) type B-1, 20mm x 6mm flat iron hinges with locking arrangement including lock 65mm, brass and keys (Godrej/Shell), MS handles and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any type of soil /soft disintegrated rock and disposal of surplus soil to a distance not exceeding 50 Mtr complete all as specified and directed
Material and labour for road crossing/drain crossing by adopting trenchless tunneling work through specified pipe jacking method by erecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunneling, excavation in any type of soils, hard rock etc., including provision of HDPE pipe heavy duty of size 110 mm dia suitable for 0.4mpa working pressure as casing pipe in any length with jointing materials, inserting GI tubing, medium grade upto 50mm bore with Horizontal Directional Drilling (HDD) technique to a depth not less than 2m below the ground level from starting point to end point, necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorities etc., complete all as specified and as directed. Note : - (i) GI pipe medium grade will be measured and paid seperately under relevant item as supply only. (ii) The unit rate quoted shall be deemed to include the cost of 110mm dia heavy duty HDPE pipe, Earthwork and excavation in any type of soil for erecting the equipment.
EXTERNAL ELECTRIC SUPPLY
Supply install commission and test outdoor floor mounted cubical type LT panel board factory fabricated made out of CRCA sheet not less than 3.15 mm thick including enclosed busbar chamber with aluminium bus bar 400 Amps complete and painting with 2 coats of powder coated paint over a coat of red oxide primer including with 250 Amps MCCB as incomer 4 pole 415 volts thermal magnetic setting type, 35 KA breaking capacity complete all as specified and as directed.
Supply & Fix Hot press moulded SMC Junction box of size 270 mm x 200 mm x 135 mm with right operable hinged door with two number aluminium bus bars mounted on porcelain insulator including clamps of MS flat iron 25 x 3 mm with bolts and nuts and including one MCB SP upto 6A, 10 KA for ON/OFF street light, fixed on pole Complete all as specified and directed.
Material and labour for Trenchless boring horizontaly underneath the existing bituminous macadam road/drain crosswise by adopting trenchless tunneling work through specified pipe jacking method by erecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunneling, excavation in any type of soils, hard rock etc., including provision of HDPE pipe heavy duty of size 110mm bore as casing pipe with all fittings and inserting it into the trenchless boring to carry LT UG cables of size upto 300 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorities etc., complete all as specified and as directed. Note: (i) LT UG cable shall be measured and paid separately under relevant item and Schedule (ii) The unit rate quoted shall be deemed to include the cost of 110mm dia heavy duty HDPE pipe, Earthwork and excavation in any type of soil for erecting the equipment.
EARTHING
Earthing complete with Galvanised steel earth plate electrode 600x600x 6mm buried directly in the ground vertically to depth not less than 3 Mtr below the ground level with the top edge of earth plate, depth not less than 2.25 Mtr below the ground level connected to GI earth strip of 32 mm x 6 mm size by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia upto Test point 20 mm dia watering pipe with funnel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus soil and providing charcoal dust & salt layers all around the earth plate upto 15 cm all as required specified & directed by engr in charge Note :- The rate is deemed to be inclusive of the cost of earth work, excavation on any type soil and removal of surplus soil to a distance of 50 Mtrs, PCC 1:2:4 type B1 for earth pit cover 6 Nos 6 mm dia CTD bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI strip length up to 7.50M will be measured as one unit)
Earthing complete with Galvanised steel earth plate electrode 600x600x 6mm buried directly in the ground vertically to depth not less than 3 Mtr below the ground level with the top edge of earth plate, depth not less than 2.25 Mtr below the ground level connected to GI earth wire 4 mm size by means of bolts, nuts and washers protected by GI tubing light grade 15 mm dia up to Test point 20 mm dia watering pipe with funnel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus soil and providing charcoal dust & salt layers all around the earth plate upto 15 cm all as required specified & directed by engr in charge Note :- The rate is deemed to be inclusive of the cost of earth work, excavation on any type soil and removal of surplus soil to a distance of 50 Mtrs, PCC 1:2:4 type B1 for earth pit cover 6 Nos 6 mm dia CTD bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI wire length up to 7.50M will be measured as one unit) For Building Earthing - 03 Nos For Street light pole - 06 Nos
KARNI BUILDERS
M/s S N Atiwadkar
Phoenix Infra
ASHIRWAD ELECTRICALS
SOOD ASSOCIATES PVT LTD
M/S B.SHRAVAN KUMAR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .