Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L1 | Accepted-AOC Being a lowest bidder and reasonable | |
| 2 | L2₹44.2 L+₹1.2 L (2.79%)Rejected-Finance PO CHANDL PS BISHNUPUR DIST SOUTH 24 PGS PIN 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹44.3 L+₹1.3 L (3.03%)Rejected-Finance 6 NALAPUKUR LANE FLAT 2C SENHATI COLONY KOLKATA 700034 WEST BENGAL | KOLKATA | WEST BENGAL | 700034 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹44.9 L+₹1.9 L (4.50%)Rejected-Finance 107 1F TOLLYGUNGE ROAD KOLKATA 700026 WB | KOLKATA | WEST BENGAL | 700026 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹45.3 L+₹2.3 L (5.41%)Rejected-Finance BHANGARMATH THAKURANI CHAWK PO SAMABYPALLY BALLY HOWRAH 711 205 WEST BENGAL | HOWRAH | WEST BENGAL | 711205 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹39.6 L
EMD Value
₹79,200
Closing Date
1 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/ MAINT OF VARIOUS CENTRIFUGAL/ MANOBLOCK AND SUBMERSIBLE PUMPING SETS, BOOSTER PUMPING SETS WITH CONNECTED ACCESSORIES AND ALLIED WORKS AT OUTSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2023_MES_622762_1
8184/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE(FW) Kolkata
Refer tender documents
7 documents required · 7 mandatory
₹500
GE (FW) Kolkata
₹79,200
29 Jan 2024
11 Oct 2023
3 Nov 2023
11 Oct 2023
1 Nov 2023
25 Oct 2023
Amount
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and directed.
Demolition of Cement Concrete (un-reinforced) in Ground Floors and Pavings not exc. 150mm thickness (above or below Ground Level), complete all as specified and directed.
M&L Plain Cement Concrete type B1 (1:2:4) using 20 mm stone aggregate as in Foundation of monoblock pump / centrifugal pump, Filling and Mass Concrete, surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L Brick Work with Flyash Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
Material and labour for 10 mm thick rendering in cement mortar (1:6) to fair faces of brick or concrete wall surfaces, finished even and smooth without using extra cement all as specified and as directed by the Engineer-in-Charge.
Disconnecting all electric / water supply connection from the monoblock / centrifugal pump set of any make/model, electric driven AC 3 phase, 415 Volts, from any installation, transporting to workshop, dismantling, removing the burnt out windings, cleaning the starter slots and rewinding with super enamelled copper wire of suitable gauge, insulating, proper heat varnishing, re-transportation and re-installation at same position including commissioning and testing complete for the following capacity :-
Motor of capacity 2 to 3 HP
Motor of capacity 5 HP
Motor of capacity 7.5 HP
Motor of capacity 10 HP
Motor of capacity 12.5 to 15 HP
Motor of capacity 20/25 HP
Motor of capacity 40 HP
Motor of capacity 72/90 HP
S&F Ball bearing for AC 3 phase 415 Volts induction motor / monoblock pump set of the following capacities as in repair, complete all as directed by the Engineer-in-Charge :-
Motor of capacity 2 to 3 HP (Make of Bearing - SKF with Cat No. 6305-RS1 or equivalent model in NBC / TATA / NRB)
Motor of capacity 5 HP (Make of Bearing - SKF, 6306-2RS1/C3 or equivalent model in NBC / TATA / NRB)
Motor of capacity 7.5 HP (Make of Bearing: SKF, 6306-2Z, 6306-2Z/C3 or equivalent model in NBC / TATA / NRB)
Motor of capacity 10 HP (Make of Bearing - SKF, 6307-2RS1 or equivalent model in NBC / TATA / NRB)
Motor of capacity 12.5 to 15.0 HP (Make of Bearing - SKF, 6308-2 RZNR/C3 or equivalent model in NBC / TATA / NRB)
Motor of capacity 20/25 HP (Make of Bearing - SKF, 6309-2RS1 or equivalent model in NBC / TATA / NRB)
Motor of capacity 40 HP (Make of Bearing: SKF, 6311-2Z/C3 or equivalent model in NBC / TATA / NRB)
Motor of capacity 72/90 HP (Make of Bearing - SKF, 6313-2Z, 6313-2Z/C3 or equivalent model in NBC / TATA / NRB)
Disconnecting of all electric connection, taking out 3 phase, 415 Volts induction electric motor from any installation of any make (other than as catered under Item No. 06 here-in-before), transporting to workshop, dismantling, overhauling with proper heat varnishing, (for proper insulation), re-metalling, machine polishing of rotor shaft, terminal box and applying one coat synthetic enamel paint, transporting back to work-site for reinstallation of the same including testing complete for the following capacities :-
Motor of capacity 2 to 3 HP
Motor of capacity 5 HP
Motor of capacity 7.5 HP
Motor of capacity 10 HP
Motor of capacity 12.5 to 15.0 HP
Motor of capacity 20/25 HP
Motor of capacity 40 HP
Dismantling and taking out of the following capacity pump sets of any type (monoblock/centrifugal) complete of any make from any installation , transporting to workshop and re-installation in same position after replacement of worn out spares and painting with one coat of synthetic enamelled paint to pump only including commissioning and testing on completion all as directed by the Engr-in-Charge. (Note: Spares replaced, will be measured and paid separately under relevent item of this schedule).
Capacity of 2 to 3 HP
Capacity of 5 HP
Capacity of 7.5 HP
Capacity of 10 HP
Capacity of 15 HP
Capacity of 20/25 HP
Capacity of 40 HP
Motor of capacity 72/90 HP
Supply only cast iron impeller, suitable for 2 / 3 / 5 HP capacity monoblock pump complete all as specified and directed.
All as per item No.10 above, but suitable for 7.5 HP to 15 HP
All as per item No.10 above, but suitable for 20 HP to 40 HP
M & L for re-metalling, grinding and re-polishing of damaged CI impeller of any pump capacity, as directed by the Engineer-in-Charge.
Supply and fix in replacement of gun metal gland bush including graphite gland packing for induction / monoblock pump set of capacity 5 HP to 20 HP, complete all as specified and directed.
All as per item Ser No 14 here in before, but pump set of capacity 25 to 40 HP
All as per item Ser No 14 here in before, but pump set of capacity 92/90 HP
Re-metalling, grinding, and polishing of impeller cover of any size 5 HP to 20 HP monoblock pump complete all as specified and directed.
All as per item ser No. 17 above, but of size 25 to 40 HP
Drilling and tapping of any size pump & motor base / body for removing old broken Nuts & bolts and fixing with new nuts, bolts & washers complete all as specified and directed. (Note : New nuts, bolts & washers wiil be paid separetely).
Re-metalling and re-shaping of impeller key slot, for pumps complete all as specified and directed.
Removing the existing foot valve/check valve of any type carefully by dismantling water supply pipes of size 40mm to 80mm dia and opening, cleaning incl replacement of new bolt, nut, washers of suitable size & gasket, re-fixing after repairs complete all as specified and directed.
All as per item ser No. 21 above, but of pipe size 100 mm to 200 mm.
S&F MS studs with nut as per exsiting size & shape of size 1/4" to 5/8" in repairs, complete all as specified and directed.
S&F impeller key suitable for any type of pump, in repairs complete all as specified and directed.
S&F check nut (suitable for any type of pump), in repairs complete all as specified and directed.
M&L Checking and balancing of old shaft for monoblock / centrifugal pump of any capacity / type including re-metalling and polishing, and re-fixing complete all as specified and directed.
Dismantling existing rusted / damaged base plate/frame of monoblock pump / centrifugal pump of capacity 5 HP to 15 HP, any make, incl demolition of existing PCC foundation and providing new base plate/frame as per existing specifications and new MS foundation nuts, bolts washers of suitable size including providing new PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) block of suitable size complete all as specified and directed.
All as per item No 27 above, but of capacity 20 HP to 25 HP
All as per item No 27 above, but of capacity 40 HP Capacity
S&F motor cooling fan suitable for 5 HP to 15 HP induction motor in repairs , complete all as specified and directed.
All as per item No 30 above, but for 20 to 40 HP induction motor.
S&F SS Sleeve for any type of monoblock & centrifugal pump of capacity 5 to 40HP in repairs ,complete all as specified and directed.
Disconnecting of all electric / water supply connection from the panel/water line, taking out submersible pump set including column pipe (motor and pump) of 15.0 HP to 25 HP capacity of any make / model by using tripod & chain pully from site to workshop, dismantling the pump part by part, after stripping off the pump and motor, segregating the unserviceable and serviceable parts, cleaning, re-metalling and machine polishing, slot cutting, threading of all parts as required, re-assembling including replacement of worn out spares and painting with one coat of synthetic enamel paint, re-transporting to work-site lowering the pump set including column pipe and re-connection of electrical and mechanical joint, testing of pump set complete all as specified and directed. (Note : New spares, nuts, bolts, gasket & painting of column pipes are to be measured and paid separately).
Supply only following spare parts for replacing unserviceable parts against Item No. 33 here-in-before:-
Cable guard
Suction case strainer
Counter thrust bearing
Diffuser ring
Bearing sleeve
Bearing bush upper / lower
Suction case (Intermediate)
Neck ring (Intermediate seal ring)
Pump shaft
Shaft sealing bush
Impeller (Gun metal)
Key of impeller
Sand guard
Non-return valve assembly
Seal cap
Coupling for pump
Stage casing (Bowl)
Adjusting cap
Rubber 'O' ring
Sleeve for shaft
Seal for shaft
Ring insert for non-return valve
MS nipple 150 mm size with heavy flange with suitable holes and reducer complete duly welded and threaded as required
MS nipple 80mm / 100 mm size with heavy flange with suitable holes and reducer complete duly welded and threaded as required
Oil seal
Diaphragm
Circlip
Coupling sleeve
Upper bearing bush
Lower bearing bush
Thrust bearing plate
Counter thrust segments
Drain plug
Seeking ring
Stud ring upper / lower
Thrust carbon
Rotor sleeve
Motor base
Pressure compensation rubber
Gunmetal bearing bush
Stainless steel stud
SS nut of size 8 mm / 12 mm
Nylon washer
Bearing bush (rubber)
Flange upper / lower
Lock nut
Re-metalling grinding, polishing of existing gun metal impeller (of any size) of submersible pump set of 15.0 HP to 25 HP capacity of any make / model complete all as specified and directed
Repairing of existing NRV (by replacement of valve iron balls and cleaning etc) of submersible pump set of 15.0 HP to 25 HP capacity of any make / model complete all as specified and directed
Re-metalling, grinding, polishing of existing stage casing (Bowl) of submersible pump set of 15.0 HP to 25 HP capacity of any make / model complete all as specified and directed
Re-metalling, grinding & polishing of existing gun metal impeller for submersible pump set of 15.0 HP to 25 HP capacity of any make / model complete all as specified and directed
M & L for rewinding of submersible motor of capacity 17.5 HP to 25 HP of any make and any type with super enamelled copper wire of suitable gauge, insulated & water proof including re-assembling the motor, jointing with insulated materials etc,. incl testing complete all as directed by Engr-in-Charge.
M & L for rewinding of submersible motor of capacity 5 HP to 10 HP of any make and any type with super enamelled copper wire of suitable gauge, insulated & water proof including re-assembling the motor, jointing with insulated materials etc,. incl testing complete all as directed by Engr-in-Charge.
S&F in repair MS column pipe 100mm bore medium grade (heavy duty) flanged type complete with nuts, bolts, rubber including groove for cable entrée system with gasket etc of 10 ft length complete all as directed by the Engr-in-Charge.
All as per item 41 above, but of size 150 mm bore
S&F in repair bore well cap for 8" x 12" tube well, made with 10 mm thick mild steel sheet, in two parts with cable/column pipe entry system and locking arrangements complete as directed by the Engr-in-Charge.
Supply and fixing MS nut and bolt with MS washer of any size for jointing of MS column pipes / pump mounting bolts / valves etc.as in repair, complete all as specified and directed.
S&F in replacement of rubber gasket 3mm thick for jointing of column pipe of 100 to 150 mm bore complete all as specified and directed.
M & L for greasing for bearing (of centrifugal pumps / Monoblock pumps) of 5 to 15 HP pump sets any make as directed by the Engr-in-Charge. Note:- (Each greasing job will be measured and paid as one unit)
All as per item No. 46 above, but of 20 to 40 HP pump sets
S&F MS star/round coupling with star rubber bush / Rubber round copling with MS plate incl necessary nut, bolt & washers complete of centrifugal pumps 5 HP to 15 HP capacity as in repair, complete all as specified and directed by Engr-in-Charge.
All as per item No. 48 above, but of pump capacity 20 to 40 HP.
M&L for cleaning of old painted surfaces of 100 mm bore column pipe with iron brushes and applying one coat of black bituminous paint (suitable for drinking) on the surface of column pipe (inside and outside) of length 10' - 0', complete all as specified and directed by Engr-in-Charge.
All as per item No 50 above, but of pipe size 150 mm bore
M&L for welding work in running pipe line / MS frame in any length and thickness not exceeding 9 mm thcik in any position complete all as specified and directed by Engr-in-Charge.
S&F MS gland coupling suitable for 40 HP DSM pump set by opening the pump cover & shaft as in repair, complete all as specified and directed.
M&L complete removal of existing paint from water supply pipeline network of 50mm bore including valves, NRVs/joints of any type and size at various pump houses and aplying two coats of synthetic enamel paint (colour/shade as approved by Engr-in-Charge) and marking the water flow directions on pipe lines complete all as specified and as directed for the following sizes :-
50 mm bore pipe
65 mm bore pipe
80 mm bore pipe
100 mm bore pipe
150 mm bore pipe
200 mm bore pipe
S&F in repair Cast Iron Sluice valve of Class PN-1.6 long body type, heavy duty, ISI marked (IS 1538) flanged end with iron wheel and brass spindle including rubber gasket joints, nuts, bolts etc complete all as specified and directed for the following size of pipes :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
S&F in repair, Cast Iron non-return valve, with bypass arrangement, ISI marked, with flanged ends including rubber gasket joints, nuts, bolts etc complete all as specified and directed for the following size of pipes :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
S&F in repair butterfly valve, SG iron body, lever operated, with stainless steel disc and stem, conforming to BS:5155, PN-16 with necessary nitrile rubber gaskets, nuts and bolts and washers of suitable size as directed by the Engineer-in-Charge for the following size :- (MAKE: ZOLOTO, Cat No: 1078B or equivalent model in other makes specified in CA)
40 mm bore
50 mm bore
80 mm bore
100 mm bore
150 mm bore
200 mm bore
S&F in repair butterfly valve, gear operated, conforming to BS:5155, PN-16 with necessary rubber gaskets, nuts and bolts and washers of suitable size as directed by the Engineer-in-Charge.
100 mm bore
150 mm bore
200 mm bore
S&F Push button Actuator switch of any colour incl necssary connections as in repair, complete all as specified and directed by Engr-in-Charge. (Make: L & T, Cat No : SS91519 or equivalent model in other makes specified in tender)
S&F Indication lamp set, RYB, LED type, as in repair, complete all as specified and directed by Engr-in-Charge.
S&F ML bi-metal overload relays, ranging from 9 Amp to 14 Amp, incl necessary incoming & outgoing elect connections, copper lugs, etc as in repair., complete all as specified and directed by Engr-in-Charge. (Make : L&T, Cat No: SS 91859 OOAO or equivalent model in other makes specified in tender)
All as per item No 64 above, but relay ranging from 20 Amp to 32 Amp. (Make : L&T, Cat No: SS 91859 OOEO or equivalent model in other makes specified in tender)
S&F in repairs Single Phase Preventor Relay, type SDz5, 415 Volts incl necessary electrical connections complete all as specified and directed. (Make : L & T, Cat No: XM81809OOOO or equivalent model in other makes specified in tender)
S&F in repairs Single Phase Preventor Relay, type SDz5, 380 Volts incl necessary electrical connections complete all as specified and directed. (Make : L & T, Cat No: XM81807OOOO or equivalent model in other makes specified in tender)
S&F in repair electronic timer of type ST-100, suitable for 3 - 30 seconds, 160-500 V, incl necessary incoming & outgoing elect connections, copper lugs etc complete all as specified and directed. (Make : L&T, Cat No: ST80328OOOO or equivalent model in other makes specified in tender)
S&F in repair 3 pole power contactor of type ML-1.5, (2NO + 2NC), suitable for 415 Volts, AC1 & AC3 rating of 25 Amps incl necessary incoming & outgoing elect connections, copper lugs, etc. complete all as specified and directed. (Make : L&T, Cat No: SS 91851 or equivalent model in other makes specified in tender)
All as per item No 69 above, but contactor of type ML-2 (2NO + 2NC), AC1 rating 40 Amps and AC3 rating 32 Amps (Make : L&T, Cat No: SS 90701 or equivalent model in other makes specified in tender)
All as per item No 69 above, but contactor of type ML-3, (2NO + 2NC), AC1 rating 45 Amps and AC3 rating 40 Amps (Make : L&T, Cat No: SS 90721 or equivalent model in other makes specified in tender)
S&F in repair Submersible pump controller fully automatic star delta starter for 30 HP motor in sheet steel enclosure (motor rating AC-3 Duty, 415 V, 50 Hz, 3 Phase) with relay range 30-50 Amps complete type MU-G30 including stripping off the existing starter from panel etc and necessary incoming & outgoing elect connections, copper lugs, etc. complete all as specified and directed (Make : L&T, Cat No: CS96008COGO or equivalent model in other makes specified in tender)
Aall as item No.74 above, but for motor of 15 HP with relay range 13-22 Amps (Make : L&T, Cat No CS94091SODO or equivalent model in other makes specified in tender)
S&F in repair fully automatic star delta starter in sheet steen enclosure, type ML 2 (Max Motor output 20 HP, 440V, 50Hz, 3Ph) relay range 13-21 Amps and necessary incoming & outgoing elect connections, copper lugs, etc. complete all as specified and directed. (Make : L&T, Cat No SS90705POCO or equivalent model in other makes specified in tender)
S&F in repair HRC bolted type fuse with base 63 Amps capacity, incl necessary incoming & outgoing elect connections, copper lugs, etc., complete all as specified and directed. (Make : L&T, Cat No: ST35828 & ST30761 or equivalent model in other makes specified in tender)
S&F DOL starter in sheet steel enclosure, type MN16 DOL, max output 7.5 HP, 415 Volts, 50 Hz, 3 phase, relay range 9-15 Amps incuding all necessary electric connections and fixing arrangement complete all as specified and directed. (Make :- L&T, Cat No: SS 94351 or equivalent model in other makes specified in tender)
S&F in repair MCB, TPN, 63 Amps, 'C' curve, 10 kA including necessary incoming & outgoing elect connections, copper lugs, etc., as in repair, complete all as specified and directed. (Make :- L&T, Cat No: BB40630C or equivalent model in other makes specified in tender)
S&F in repair MCB, DP, 32 Amps, 'C' curve, 10 kA including necessary incoming & outgoing elect connections, copper lugs, etc., as in repair, complete all as specified and directed. (Make :- L&T, Cat No: BB20320C or equivalent model in other makes specified in tender)
S&F in repair PVC insulated flat industrial copper cable, of cross-sectional area 10 sq mm x 3 core, suitable for submersible pump, including necessary incoming & outgoing elect connections, copper lugs, water proofing compound etc., connected to starter / motor, complete all as specified and directed by Engr-in-Charge.
All as per item No 81 above, but of size 6 sq mm x 3 core
S&F in repair FRLS-H PVC insulated single core copper cable, of cross-sectional area 6 sq mm incl necessary copper lugs etc to connect MCB/MCCB/ contactor etc incl necessary incoming & outgoing elect connections, copper lugs, complete all as specified and directed by Engr-in-Charge.
All as per item No 83 above, but of cross sectional area 10 sqmm
All as per item No 83 above, but of cross sectional area 16 sqmm
M & L for dismantling the existing CI foot valve of size 200 mm dia from the underground sump replace the leather gasket of suitable thick and size / door, MS weights, cleaning and re fixing the same with new GI MS bolt, nut and washer of required size complete all as specified and directed by Engr-in-Charge.
All as per item No 86 above, but of size 150 mm dia
S&F Rubber star / round coupling suitable for pump sets 10 to 20 HP capacity incl replacement of nut, bolt & washers as in repair, complete all as specified and directed by Engr-in-Charge.
All as per item No 88 above, but for pumpsets of 25 to 40 HP capacity
S&F in repair Cast iron bend (any type, radius and angle) taper any type (straight, bend, increasing, decreasing or double socket etc) tee pieces, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs, complete all as specified and directed.
Burning out lead joints in position of cast iron pipes, fittings and re-making joints using old retrieved lead complete all as specified and directed for following size of pipes :-
80mm bore
100mm bore
150mm bore
200mm bore
Note for Item No 91.01 to 91.04: In case, inadequate lead is retrieved from burning out, for remaking joints, additional lead required shall be measured and paid separately as "Supply only".
Supply only lead confirming to IS 782 complete all as specified and as directed.
S&F in repair 50 mm bore Gun metal gate valve with iron wheel head, screwed both ends for iron pipes or for unions, as in repair, as per IS : 778-84 Marked CL-2 Pressure tested 2.4 Mpa complete all as specified and directed.
All as per item No 93 above, but of size 40 mm bore
All as per item No 93 above, but of size 25 mm bore
All as per item No 93 above, but of size 20 mm bore
Taking out suction pipe of 200mm bore with defective CI foot valve/stainer of 200 mm dia for replacement of the foot valve (ISI marked) including necessary nut, bolt, washers and cutting threading of GI pipe and lowering in the sump complete all as directed by the Engr-in-Charge.
All as per item No 97 above, but of size 150 mm bore foot valve
All as per item No 97 above, but of size 100 mm bore foot valve
All as per item No 97 above, but of size 80 mm bore foot valve
Taking down UP/down Unserviceable / rust valve pit cover and frame / support or platform etc of any size/thickness and supply, fabrication and fixing of framed bracket, made of mild steel plate/flat/angle iron (of required size ), cut to shape and size,as in valve pit cover /frame/support or platform including two coats of black bituminous paint over a coat of red oxide zinc chome primer complete all as directed .
S&F in repair MCCB, 100 Amps, 3 pole, 18 KA breaking capacity, with thermal magnetic release complete all as directed by the Engr-in-Charge. (Make : L&T, Cat No: CM90517OOKO or equivalent model in other makes specified in tender)
S&F in repair MCCB, 100 Amps, 4 pole, 18 KA breaking capacity, with thermal magnetic release complete all as directed by the Engr-in-Charge. (Make : L&T, Cat No: CM90518OOKO or equivalent model in other makes specified in tender)
S&F in repair MCCB, 200 Amps, 4 pole, 25 KA breaking capacity, with thermal magnetic release complete all as directed by the Engr-in-Charge. (Make : L&T, Cat No: CM90634OONO or equivalent model in other makes specified in tender)
S&F in repair MCCB, 250 Amps, 4 pole, 25 KA breaking capacity, with thermal magnetic release complete all as directed by the Engr-in-Charge. (Make : L&T, Cat No: CM90634OOPO or equivalent model in other makes specified in tender)
Disconnecting and lifting up of submersible pump set (motor, pump & column pipe) and development of tubewell by using chemical with suitable capacity air compressor and vertical turbine equipment (till sand free potable water is available upto the satisfaction of the Engr-in-Charge) including to & fro hire charge of special T&P including lowering of pump and motor complete and testing on load of pump set (motor and pump) complete all as specified and directed.
Supply, installation, testing and commissioning of Chemical Solution Dosing System comprising of dosing pump (suitable for chlorine solution prepared from calcium based granules/ solution prepared from Poly Aluminium Chloride (PAC) Inorganic soluble polymer raw water flocculants powder), AC, single phase, 230 Volts, 50 HX, electrically operated with high starting torque, having positive displacement diaphragm type accurated by a solenoid solid state pulsar, with discharge capacity of 1 to 6 Litres/ Hour of standard mixture of calcium based calcium base Chlorine granule with water/ PAC with water, of any strength and suitable for injecting chemical mixture at 4 to 6 Kg per sq cm pressure, with provision of polypropylene / LDPE suction and discharge pipes of suitable size and length with swing seal foot valve at bottom end of suction pipe, and with 150 Litres capacity FRP tank with FRP Lid having post hole for pouring calcium based chlorine granules/ PAC and water, including provision for mounting the dosing pump on the lid/ wall of FRP tank, provision of Level Gauge, Agitator (1280 to 1400 RPM) with shaft and blade in SS 316 (FRP Coated/ Epoxy Coated/ Plastic Coated) mounted on tank complete with all accessories required for installation as per Manufactures instruction including supply of 02 (Two) Years normal maintenance Spares i.e (i) PVC Pump roller tube - 02 (Two) Nos. (ii) Mixing Blade complete with PVC shaft and pin as per Manufacturers instructions - 02 (Two) Sets. and including making provision of mouniting the pump set and provision of PCC foundation for placing the FRP tank, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 32 X 6 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
Taking out unserviceable LT panel board (of any size) and Supply, install, commissioning and testing of indoor type LT panel board, cubical type, dust and vermin proof, made out of 2.0 mm thick CRCA sheet of adequate size, fabricated in CPRI approved factory with front and back openable door (with locking arrangement) and making compartment for each ACB/MCCB/change over switch separately, duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer inclusive of four numbers copper bus bar of 300 Amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with angle iron with base 40x40x6mm with legs not more than 60cm including grouting with PCC 1:2:4 type B1 complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories :- Location: Taramondal Pump House
OUTGOING (i) MCB, 4 pole, 32A, 10 kA, adjustable type - 03 Nos. (ii) MCB DP 32 A, 10 KA adjustable type - 04 Nos (Make: L&T, Cat / HAGER, / SCHNEIDER, / LEGRAND, / C&S) iIii) FASD starter for Cap 7.5 HP with motor protection relay suitable for motor protection against overload, single phasing, reverse running, abnormality in supply, unbalanced current etc - 02 Nos (iv) FASD starter for Cap 10 HP with motor protection relay suitable for motor protection against overload, single phasing, reverse running, abnormality in supply, unbalanced current etc - 02 Nos (v) FASD starter for Cap 30 HP with motor protection relay suitable for motor protection against overload, single phasing, reverse running, abnormality in supply, unbalanced current etc - 02 Nos (Make L&T/BCH/SCHNEIDER or equivalent model in other makes specified in tender) Note:- (i) All incoming and out going cables, duly thimble along with suitable size of brass cable glands, to be connected to accessories. (ii) All ACB, MCCB & Changeover to be connected internally with suitable size of copper strip.
Taking out unserviceable LT panel board (of any size) and Supply, install, commissioning and testing of indoor type LT panel board, cubical type, dust and vermin proof, made out of 2.0 mm thick CRCA sheet of adequate size, fabricated in CPRI approved factory with front and back openable door (with locking arrangement) and making compartment for each ACB/MCCB/change over switch separately, duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer inclusive of four numbers copper bus bar of 300 Amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with angle iron with base 40x40x6mm with legs not more than 60cm including grouting with PCC 1:2:4 type B1 complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories :- Location: Pump House No.03
OUTGOING (i) MCB, 4 pole, 32A, 10 kA, adjustable type - 03 Nos. (ii) MCB DP 32 A, 10 KA adjustable type - 04 Nos (Make: L&T, Cat / HAGER, / SCHNEIDER, / LEGRAND, / C&S) iIii) FASD starter for Cap 7.5 HP with motor protection relay suitable for motor protection against overload, single phasing, reverse running, abnormality in supply, unbalanced current etc - 02 Nos (iv) FASD starter for Cap 10 HP with motor protection relay suitable for motor protection against overload, single phasing, reverse running, abnormality in supply, unbalanced current etc - 02 Nos (Make L&T/BCH/SCHNEIDER or equivalent model in other makes specified in tender) Note:- (i) All incoming and out going cables, duly thimble along with suitable size of brass cable glands, to be connected to accessories. (ii) All ACB, MCCB & Changeover to be connected internally with suitable size of copper strip.
Taking out unserviceable LT panel board (of any size) and Supply, install, commissioning and testing of indoor type LT panel board, cubical type, dust and vermin proof, made out of 2.0 mm thick CRCA sheet of adequate size, fabricated in CPRI approved factory with front and back openable door (with locking arrangement) and making compartment for each ACB/MCCB/change over switch separately, duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer inclusive of four numbers copper bus bar of 300 Amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with angle iron with base 40x40x6mm with legs not more than 60cm including grouting with PCC 1:2:4 type B1 complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories :-
UNITED ENGINEERS
SOMANI BUILDERS
DEEPAK KHATTAR
dutta and dutta
GHOSH ENTERPRISE
ARJUN DAS VALECHA
S.K. TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .