GE WEST PRAYAGRAJ
GE WEST PRAYAGRAJ PIN-211001
REPAIR / MAINTENANCE OF OH LINES / UG CABLES, POLES IN OTM MD ACCN AND FEEDER PILLAR BOX, REPLACEMENT OF MCB / BUS BAR, LT PANELS AND ITS CONNECTED WORKS AT NEW CANTT PRAYAGRAJ.
2024_MES_662983_1
8715/E8
Open Tender
Civil Works
Item Rate
270 days
NEW CANTT PRAYAGRAJ
As per tender Documents
8 documents required · 8 mandatory
₹500
GE WEST PRAYAGRAJ
₹90,000
Yes
29 Oct 2024
29 Jun 2024
10 Sept 2024
29 Jun 2024
3 Sept 2024
13 Jul 2024
Amount
Disconnecting & dismantling of damaged/unsv cable any type /make and Supply & laying cable PVC Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade of size 25 Sqmm 4 core with stranded aluminium conductor using lugs/ferrul both end of cable & wrapping PVC tape over XLPE insulation cable and testing complete all as specified and directed. Note: - Excavation, earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under respective item.
Disconnecting & dismantling of damaged/unsv cable any type /make and Supply & laying cable PVC Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade of size 35 Sqmm 4 core with stranded aluminium conductor using lugs/ferrul both end of cable & wrapping PVC tape over XLPE insulation cable and testing complete all as specified and directed. Note: - Excavation, earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under respective item.
Disconnecting & dismantling of damaged/unsv cable any type /make and Supply & laying cable PVC Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade of size 50 Sqmm 3.5 core with stranded aluminium conductor using lugs/ferrul both end of cable & wrapping PVC tape over XLPE insulation cable and testing complete all as specified and directed. Note: - Excavation, earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under respective item.
Disconnecting & dismantling of damaged/unsv cable any type /make and Supply & laying cable PVC Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade of size 70 Sqmm 3.5 core with stranded aluminium conductor using lugs/ferrul both end of cable & wrapping PVC tape over XLPE insulation cable and testing complete all as specified and directed. Note: - Excavation, earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under respective item.
Disconnecting & dismantling of damaged/unsv cable any type /make and Supply & laying cable PVC Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade of size 95 Sqmm 3.5 core with stranded aluminium conductor using lugs/ferrul both end of cable & wrapping PVC tape over XLPE insulation cable and testing complete all as specified and directed. Note: - Excavation, earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under respective item.
Disconnecting & dismantling of damaged/unsv cable any type /make and Supply & laying cable PVC Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade of size 120 Sqmm 3.5 core with stranded aluminium conductor using lugs/ferrul both end of cable & wrapping PVC tape over XLPE insulation cable and testing complete all as specified and directed. Note: - Excavation, earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under respective item.
Disconnecting & dismantling of damaged/unsv cable any type /make and Supply & laying cable PVC Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade of size 185 Sqmm 3.5 core with stranded aluminium conductor using lugs/ferrul both end of cable & wrapping PVC tape over XLPE insulation cable and testing complete all as specified and directed. Note: - Excavation, earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under respective item.
Excavation in trenches not exc 1.5 Mtr wide and n.exc 1.5 mtr in depth, getting out for laying of electric cable complete in any type of soil complete all as specified and directed. Note :- For the digging of soil, JCB machine will not be allow at site, it will be done by labour only and contractor will be responsible to repair the existing cable , pcc plinth etc without extra cost which will be damaged during execution of wk.
Removing surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above starting point complete all as specified and directed.
Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed.
M&L for sand cushioning with ganga sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable complete all as specified and directed. Note:- Punned thickness of sand shall be measured for payment.
M&L in replacement for 50 mm bore GI tubing light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor / as garden post including 2 Nos mild steel FI clamps 35x3 mm size to support pipe with pole complete all as specified and directed.
M&L in replacement for 80 mm bore GI tubing light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor / as garden post including 2 Nos mild steel FI clamps 35x3 mm size to support pipe with pole complete all as specified and directed.
Dismantling & taking out defective LT PVC/XLPE cable from trenches with cutting and removing defective parts and supply & making cable joint of size 25 Sqmm 3.5 core to 70 Sqmm, 3.5 core using straight through joint Hot shrink type and making connection of LT cables, meggering & restoration of electric supply complete including jointing material complete all as specified & directed.
Dismantling & taking out defective LT PVC/XLPE cable from trenches with cutting and removing defective parts and supply & making cable joint of size 95 Sqmm 3.5 core to 240 Sqmm 3.5 core using straight through joint Hot shrink type and making connection of LT cables, meggering & restoration of electric supply complete including jointing material complete all as specified & directed.
S&F in replacement, the following items in the existing out door/ indoor LT panels and connection with using aluminium lugs/ferrules including disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection complete all as specified and directed as below:-
MCCB 4 pole 63 to 100 amps rating, 10 KA breaking capacity, 415 Volt with spreader at both side.
MCCB 4 pole 160 amps rating, 36 KA breaking capacity, 415 Volt with spreader at both side.
MCCB 4 pole 200 amps rating, 36 KA breaking capacity, 415 Volt with spreader at both side.
MCCB 4 pole 250 amps rating, 36 KA breaking capacity, 415 Volt with spreader at both side.
MCCB 4 pole 350 amps rating, 36 KA breaking capacity, 415 Volt with spreader at both side.
MCCB 4 pole 400 amps rating, 36 KA breaking capacity, 415 Volt with spreader at both side.
S & F in replacement, connecting to electrical system & testing of busbar panel board, cubical types, for out door use, made out of 3.15 mm thick CRCA sheet factory made, totally enclosed of appropriate size duly fixed on platform not less than 450 mm above ground level duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gasket and sealed mounted on PCC blocks double door type with locking arrangement with handle at front and operable at front & back both side with required hinges heavy duty, compartmentalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- (a) Incomer :- MCCB 250 Amp 35 KA - 01 No. (b) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 400 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. , (c) Phase indication lamp, LED type (set of 3) - 1 Set (d) Ammeter analog type having measuring range (0-300) amp with CTs etc including rotary switch to measure load of each phase. (e) Replacement of volt meter having measuring range 0-500 volt with rotary switch to measure voltage of phase RYB. (f) Grouting of panel including earth work as required PCC 1:3:6 type D2 using 20 mm graded stone aggregate and plastering with cement mortar 1:4 complete.
Supply, installation, commissioning & testing of LT distribution panel board CPRI approved made out of 3.15 mm thick MS sheet duly painted with two coats of synthetic enamelled paint over a coat of red oxide primer wall mounted/semi-grouted in wall with locking arrangement, double door type, compartmentalised and provision for tapping incoming & outgoing electric connections with suitable size of lugs, glands, one MCCB will be mounted on proper din rails and comprising of the followings : (a) Aluminium busbar chamber TPN of 200 amps rating (set of 4 strips) (b) Phase indication lamp-set of 3 (c) MCCB 4 pole 415 Volts, 50 Hz, 100 amps rating, 25 KA breaking capacity - 01 No.(Incoming ) (d) MCB TPN 100 Amp - 2 Nos and MCB SPN 32 Amp -4 Nos as outgoing control
S&F in replacement, ACB 4 pole,415 V,with Thermal Magnetic release (manual draw out type) of capacity 800 Amp , in the existing out door/indoor LT panels and connection with using aluminum lugs/ferruls incl disconnection & connection of cable and making necessary alteration in panel/door using welding work and cutting as required for proper fixing & connection complete all as specified and directed.
S&F in replacement, ACB 4 pole,415 V,with Thermal Magnetic release (manual draw out type) of capacity 1000 Amp , in the existing out door/indoor LT panels and connection with using aluminum lugs/ferruls incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50 m below ground level connected to galvanized iron strip of size 32 x 6mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 15 mm bore medium grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing not less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing , all as shown on electric plate No. 03 of SSR-2009 Part-I as in repair complete all as directed. Notes: 1. The rate quoted shall also deemed to include the cost of earth test point and earth wire and protection pipe upto 7.50 metre beyond the earth plate electrode. 2. Earth filling shall be done by vegetable soil. 3. Soil should be free from stone, boulders, aggregate, gravels etc.
S&F (in replacement) pole box junction three phase of size 297 mm x 250 mm x 130 mm, made of 2 mm MS sheet factory painted with synthetic enamel paint and inbuilt locking arrangement, outdoor type fix to pole with suitable MS clamp comprising of aluminium bus bar 16 Amp 04 Nos fix on epoxy insulated support and MCB 6 Amp 10 KA 240 volt complete all as specified & directed.
Disconnecting of OH line of ACSR conductor/GI earthing wire, opening of binding wires, jumper connections any size and restringing, tightening of conductor with suitable line vice, replacing all worn out jumper connection with suitable conductor, re-tightening and straightening all cross arms, insulators, clamps etc including replacement of all worn out nut bolts and washers complete all as specified and directed. Note:- Each conductor shall be measured separately.
M & L in replacement for factory made busbar chamber box of 1.6 mm sheet with tinned plated 04 Nos suitable for copper bars of rating 100 amps mounted on pole / wall including all connections with aluminum strips/lugs, glands to be provided at cable entries, powder coated paint complete all as specified & directed.
M & L in replacement for factory made busbar chamber box of 1.6 mm sheet with tinned plated 04 Nos suitable for copper bars of rating 200 amps mounted on pole / wall including all connections with aluminum strips/lugs, glands to be provided at cable entries, powder coated paint complete all as specified & directed.
Schedule of Credit (MINUS) Rs. 219790.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. ] This amount shall be automatically deducted to arrive at tendered sum
Aawadh associates (BID ID -3078705)
Titco Electricals (BID ID -3064704)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .