Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹20.8 L+₹11,125 (0.54%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹21.5 L+₹87,524 (4.23%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹24.7 L+₹4.0 L (19.5%)Rejected-Finance PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | L4 | Rejected-Finance High Rate |
Tender Value
Refer Docs
EMD Value
₹57,000
Closing Date
10 Oct 2020, 6:55 pmClosed
GE NDA KHADKWASLA
GE NDA KHADKWASLA
REPAIR/MAINT OF STANDBY DG SETS INSTALLED AT VARIOUS LOCATIONS UNDER AGE E/M I NDA KHADAKWASLA
2020_MES_378459_1
GE (K) 24 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE NDA KHADKWASLA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE NDA KHADKWASLA
₹57,000
Yes
23 Jan 2021
17 Sept 2020
12 Oct 2020
18 Sept 2020
10 Oct 2020
27 Sept 2020
19 Sept 2020 - 26 Sept 2020
Amount
M & L for servicing of DG sets carryout inspection/checking of cylinder assembly, piston system, piping system, cylinder liners, radiator function and cleaning throughly with cleaning agents, repair any mechanical and electrical fault etc of following capacities at different following locations :- (i) 320 KVA DG Set model greaves at (Manoj Pandey Block -01) (ii) 320 KVA DG Set model greaves at (Cadet Mess-02 ) (iii) 320 KVA DG Set model greaves at (Vyas Library) Note : - (a) The cost of spares (material) shall be measured and paid separately under respective item of Sch Á'. (b) The rates quoted against the above mentioned Items is deemed to be included for cost of labour, cost of T & P required.Contractor is responsible to provide 24x7 call back service and repair facility through competent and well experience technician. No DG Set will be left unserviceable more than 4 hrs. If DG set found unserviceable for more than 04 hrs from the time it was reported to the contractor in writing during the term of this contract recovery of 1000/-Rs per such Non fnctional DG per day will be imposed and will be recovered from the amount due to the contractor. Regarding this the decision of GE will be final and binding. (c) All dismantled old unserviceable items, except those listed in schedule of credit, retrieved from any DG set shall be deposited to MES store yard.
Ditto all as per item No 1 above but 250 KVA DG Set Model Kirloskar at Power house
Ditto all as per item No 1 above but 200 KVA DG set make Greaves at A SUB STN
Ditto all as per item No 1 above but 200 KVA DG Set, Model Greaves at swimming pool No 2 /ATT
Ditto all as per item No 1 above but 160 KVA DG set make Kirloskar at MH
Ditto all as per item No 1 above but 125 KVA DG set Make Kirloskar Trolly Mounted
Ditto all as per item No 1 above but 50 KVA DG set make Kirloskar at VIP area
Ditto all as per item No 1 above but 50 KVA DG set Cummins at AFTT
Ditto all as per item No 1 above but 62.5 KVA DG set make Greaves at power house
Ditto all as per item No 1 above but 82.5 KVA DG set model Greaves at Kondhana
Ditto all as per item No 1 above but 50 KVA DG set make kirloskar at New pashan gate
Ditto all as per item No 1 above but 50 KVA DG set make kirloskar at AFTT Addl Hanger
Ditto all as per item No 1 above but 25 KVA DG set make kirloskar at AFTT (HRDF)
Ditto all as per item No 1 above but 5 KVA DG set make Greaves at Tower No 6
Ditto all as per item No 1 above but 5 KVA DG set make Greaves at Tower No 10
Ditto all as per item No 1 above but 5 KVA DG set make Greaves at Tower No 11
Ditto all as per item No 1 above but 5 KVA DG set make Greaves at Tower No 16
Ditto all as per item No 1 above but 1 KVA Genset petrol make Birla power solution ltd
S&F in replacement V belt for fan/water pump assy etc for 320 KVA DG set including taking down existing one.
S&F in replacement V belt for fan/water pump assy etc for 200-300 KVA DG set including taking down existing one.
S&F in replacement V belt for fan/water pump assy etc for 25-190 KVA DG sets including taking down existing one.
S&F in replacement V belt for fan/water pump assy etc for 1-5 KVA Petrol genset and DG sets including taking down existing one.
S&F in replacement Air filter elements for 320 KVA DG set including taking down existing one
S&F in replacement Air filter elements 200-300 KVA DG set including taking down existing one.
S&F in replacement Air filter elements for 25-190 KVA DG sets including taking down existing one.
S&F in replacement Air filter elements for 1-5 KVA genset including taking down existing one.
S&F in repair oil Sump gasket for 320 KVA DG set including taking down existing one.
S&F in repair oil sump gasket for 200-300 KVA DG set including taking down existing one.
S&F in repair oil sump gasket for 25-190 KVA DG sets including taking down existing one.
S&F in repair oil sump gasket for 1-5 KVA Petrol genset and DG sets including taking down existing one.
S&F in repair gasket for Exhaust manifold for 320 KVA DG set including taking down existing one.
S&F in repair gasket for Exhaust manifold 200-300 KVA DG set including taking down existing one.
S&F in repair gasket for Exhaust manifold for 25-190 KVA DG sets including taking down existing one.
S&F in repair gasket for Exhaust manifold for 1-5 KVA genset including taking down existing one.
S&F in repair water hose set for 320 KVA DG set including taking down existing one.
S&F in repair water hose 200-300 KVA DG set including taking down existing one.
S&F in repair water hose for 25-190 KVA DG sets including taking down existing one.
S&F in repair water hose for 1-5 KVA Petrol genset and DG sets including taking down existing one.
S&F in repair hose clamp set for 320 KVA DG set including taking down existing one.
S&F in repair hose clamp set for 200-300 KVA DG set including taking down existing one.
S&F in repair hose clamp set for 25-190 KVA DG sets including taking down existing one.
S&F in repair hose clamp set for 1-5 KVA genset including taking down existing one.
S&F in repair Air hose set for 320 KVA DG set including taking down existing one.
S&F in repair water temp gauge for 320 KVA DG set including taking down existing one.
S&F in repair water temp gauge for 200-300 KVA DG set including taking down existing one.
S&F in repair water temp gauge for 25-190 KVA DG sets including taking down existing one.
S&F in repair water temp gauge for 1-5 KVA genset including taking down existing one.
S&F oil filter for 320 KVA DG set including taking down existing one.
S&F oil filter 200-300 KVA DG set including taking down existing one.
S&F oil filter for 25-190 KVA DG sets including taking down existing one.
S&F oil filter for 1-5 KVA genset including taking down existing one.
S&F Diesel filter for 320 KVA DG set including taking down existing one.
S&F Diesel filter 200-300 KVA DG set including taking down existing one.
S&F Diesel filter for 25-190 KVA DG sets including taking down existing one.
S&F Diesel/ Petrol filter for 1-5 KVA genset including taking down existing one.
S&F in repair solenoid valve for 320 KVA DG set including taking down existing one.
S&F in repair solenoid valve for 200-300 KVA DG set including taking down existing one.
S&F in repair solenoid valve for 25-190 KVA DG sets including taking down existing one.
S&F in repair solenoid valve for 1-5 KVA genset including taking down existing one.
Supply only engine oil of grade SAE 15 W 40 as directed in standard packings / sealed container including taking down existing one.
Supply and toping up of distilled water in standard packing /sealed container including taking down existing one.
Supply and toping up of coolant in standard packings / sealed container including taking down existing one.
Supply & fixing in repair Asbestos rope of any size as required at site including taking down existing one.
S&F Lead acid battery 180 AH 12 Volt including disconnecting existing battery terminals and reconnecting with all necessry accessories complete all as specified.
M &L Lifting loading and transportation of lead acid battery to work shop and repair to lead acid battery of 12 volt of 90/130/180 AH by filling up of distilled water,change of worn out cells, changing of unseviceble electrode/electrolyte and changing of unserviceble terminal etc all as directed.
Disconnecting all electrical connections from burnt out alteranator diesel engine set any type any make , removing burnt out winding wires from alternator slot without damage including any other connected accessories and cleaning the alternator internally and externally and provide same gauge copper wire and number of suitable runs used for winding with two coats of varnishing and reassembled the same winded alternator and graesing to all parts , tightening of all electrical terminals, removing dust from armature/stator and applying varnishing incl testing complete all as specified and directed for DG set of capacity 320 KVA DG set
Ditto all as per item no 66 above but 200-300 KVA DG set
Ditto all as per item no 66 above but 25-190 KVA DG set
Ditto all as per item no 66 above but 1-5 KVA Genset
Overhauling, repairing,calibartion of FIP set as per manufacturer's instruction and replacement of unserviceable component by providing new ones as per existing size and make all as required at site for DG Set 320 KVA
Ditto all as per item no 70 above but DG Set 200 to 300 KVA
Ditto all as per item no 70 above but DG Set 25 to 190 KVA
Ditto all as per item no 70 above but Genset 1-5 KVA
Disconnecting all incoming and outgoing rubber. Hose & drain out checking radiator assembly of the following various capacities of DG sets and taking down the radiator assembly transporting the same to civil workshop for carrying out servicing, cleaning thoroughly the choke pipe, soldering/ brazing the leakage pipe after completion in of above work reflixing the same to its original position for the following DG sets of capacity 25 KVA - 190 KVA all as directed by Engineer-in-charge.
Ditto all as per item no 74 above but DG set 200 to 300 KVA
Ditto all as per item no 74 above but DG set 320 KVA
Ditto all as per item no 74 above but Genset 1-5 KVA
M & L for draining out from the fuel tank of DG set of capacity 320 KVA and keeping it in a separate container, cleaning the fuel tank all lnternally & externally by removing all the accumulated sediments, leak testing the tank and welding/brazing including one coat of black synthetic enameled paint over a coat of red oxide and reflxing the tank to its original position & refilling the fuel back into the tank
Ditto all as per item no 78 above but DG Set of capacity 200 to 300 KVA
Ditto all as per item no 78 above but DG Set of capacity 25 to 190 KVA
Ditto all as per item no 78 above but Genset 1-5 KVA
M & L for Repair of AMF panel of various DG set by properly finding the faults, doing wiring work and repairs/replace the spares required in the panel, (Spares parts reqd for repair will be paid and measured separately). DG set of 320 KVA Note : The rates quoted against the above mentioned Items is deemed to be included for cost of labour, cost of T & P required.Contractor is responsible to provide 24x7 call back service and repair facility through competent and well experience technician. No DG Set will be left unserviceable more than 4 hrs. If DG set found unserviceable for more than 04 hrs from the time it was reported to the contractor in writing during the term of this contract recovery of 1000/-Rs per such Non fnctional DG per day will be imposed and will be recovered from the amount due to the contractor. Regarding this the decision of GE will be final and binding.
Ditto all as per item No 82 above but 200-300 KVA
Ditto all as per item No 82 above but 25- 190 KVA
Ditto all as per item No 82 above but 1-5 KVA
Supply & fixing in repair AMF controller for DG set 320 KVA including taking down existing one.
Supply & fixing in repair controller for DG set 200 to 300 KVA
Supply & fixing in repair controller for DG set 25 to 190 KVA including taking down existing one.
Supply & fixing in repair controller for Genset 1 to 5 KVA including taking down existing one.
Supply & fixing in repair electronic timers including taking down exsiting one.
Supply & fixing in repair single phase preventer including taking down existing one.
Supply & fixing in repair AVR suitable for 200 - 320 KVA DG sets including taking down existing one.
Supply & fixing in repair VMR multi function display unit with LCD for voltage, Current and frequency etc
Supply & fixing in repair Indicating lamp LED type including taking down existing one.
Supply & fixing in repair Push botton including taking down existing one.
Supply & fixing in repair Toggle switch including taking down existing one.
Disconnecting all electrical cable connection from 12 Volts DC self starter for carying out repairs, rewinding of self starter motor with super enamelled copper wires of size matching to the existing one complete with varnishing, drying, providing insulating material etc and complete overhauling the system including replacing the unserviceable parts such as bendex, contacts etc and reassembling & refixing the self starter to its original position including connection of cables & testing all as specified and directed by Engr-in-charge. (Note: spare parts except material reqd for rewinding of self starter shall be supplied sepeately).
Ditto all as per item no 98 above but 24 Volts DC
Supply only following spares for self starter :- Carbon brush
Ditto all as per item no 100 above but Carbon brush holder
Ditto all as per item no 100 above but Bearing of armature ( Make SKF)
Ditto all as per item no 100 above but Bendex drive
Ditto all as per item no 100 above but Battery terminal posltive/ Negative heavy duty of suitable model for 180 AH capacity
Supply & fix in replacement self starter suitable for 12 Volt DC operation Make - Lucas including disconnecting and taking down the existing unserviceable self starter & depositing to MES store yard.
Supply & fix in replacement self starter suitable for 24 Volt DC operation Make - Lucas including disconnecting and taking down the existing unserviceable self starter & depositing to MES store yard.
Supply and fix Fuel level pipe of 10 mm dia including taking down existing one complete all as specified and directed.
S & F in replacement of neoprene rubber gaskets of suitable size including taking down old one.
Supply and fix power contactors of AC1 630 Amps 3 Pole 415 volts including taking down existing one all as specified and directed. Make Indoasian/Schnider/L&T
Supply and fix power contactors of AC1 500 Amps 3 Pole 415 volts including taking down existing one all as specified and directed. Make TC/Schnider/L&T
Supply and fix power contactors of AC1 400 Amps 3 Pole 415 volts including taking down existing one all as specified and directed. Make L&T/TC/Schnider
Supply and fix power contactors of AC1 300 Amps 3 Pole 415 volts including taking down existing one all as specified and directed.Make Siemens/TC/Schnider
Supply and fix power contactors of AC1 250 Amps 3 Pole 415 volts including taking down existing one all as specified and directed.Make TC/Schnider/Siemens
Supply and fix power contactors of AC1 200 Amps 3 Pole 415 volts including taking down existing one all as specified and directed.Make TC/Schnider/Siemens
Supply and fix power contactors of AC3 80 Amps 3 Pole 415 volts including taking down existing one all as specified and directed.Make TC/Schnider/Siemens
Supply and fix power contactors of AC3 25 to 63 Amps 4 Pole 415 volts including taking down existing one all as specified and directed.Make TC/Schnider/Siemens
S & F MCCB 3P 630 amps, 36 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed.Make Havells/C&S/Legrand
S & F MCCB 4P 500 amps, 36 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed.Make C&S/L&T/Legrand
S & F MCCB 4P 250 amps, 25 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed.Make C&S/L&T/Legrand
S & F MCCB 4P 200 amps, 25 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed.Make.Standard/Legrand/Havells
S & F MCCB 4P 100 amps, 16 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed.Make Standard/Legrand/Havells
S & F MCCB 4P 63-80 amps, 16 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed.Make L&T/Standard/Legrand
S&F in replacement 630 amps current rating On load change over switch four pole with manual changeover open execution conforming Make - L&T/Havells/Indoasian/Standard
S&F in replacement 400 amps current rating On load change over switch four pole with manual changeover open execution conforming Make - L&T/Havells/Indoasian/Standard
S&F in replacement 200 amps current rating On load change over switch four pole with manual changeover open execution conforming Make - L&T/Havells/Indoasian/Standard
S&F in replacement 160 amps current rating On load change over switch four pole with manual changeover open execution conforming Make - L&T/Havells/Indoasian/Standard
S& F HRC Fuses DIN type 200 Amp Size 1 with fuse base including taking down existing one, drilling, screwing etc all as specified and directed. Make:L&T Cat Part No SF 94232 /Havells/Legrand
Ditto all as per item no 129 above but 250 Amp Size 1. Make:L&T Cat Part No SF 94233/Havells/Legrand
Ditto all as per item no 129 above but 315 Amp Size 1. Make:L&T Cat Part No SF 94234/Havells/Legrand
Ditto all as per item no 129 above but 400 Amp Size 2. Make:L&T Cat Part No SF 94335/Havells/Legrand
Ditto all as per item no 129 above but 500 Amp Size 3. Make:L&T Cat Part No SF 94436/ Havells /Legrand
Ditto all as per item no 129 above but 630 Amp Size 3. Make:L&T Cat Part No SF 94437 /Havells/Legrand
S & F control wiring of 1.5 Sqmm size single core stranded FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters etc. including suitable size of copper lugs, pvc CABLE ducts , suitable size of galvanised or cadmium plated high tensile nuts, bolts and washers etc all as specified and directed.
S & F control wiring of 2.5 Sqmm size single core stranded FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters including suitable size of copper lugs, with galvanised or cadmium plated high tensile nuts, bolts and washers etc all as specified and directed.
Supply,fixing, testing in replacement of Speed control unit suitable for 320 KVA as per exising make.
Supply,fixing, testing in replacement of Speed control unit suitable for 160-250 KVA as per exising capacity /make.
M&L for painting of DG Set Canopy two coats of powder coated paint as per existing colour by scrapping the old surface of canopy and applying one coat of red oxide on the surface and making good complete all as spceified as directed
M&L for painting of DG Set Exhaust with two coats of synthetic enamel aluminium paint silver colour paint by scrapping the old surface of exhaust and applying one coat of red oxide on the surface and making good. complete all as spceified as directed
Material and labour for DC actuator 24 Volts, DC Actuator alongwith load trail, suitable for 320 kVA Gnerator Make. GAC (Governor America Corp) ,President Engg/Kana Engg
Material and labour for DC actuator 12 Volts, DC Actuator alongwith load trail, suitable for 25-250 kVA Gnerator Make. GAC (Governor America Corp) ,President Engg/Kana Engg
Taking down the unserviceable turbo charger assembly after disconnecting the machanical connections fro DG Set of capacity 100 to 320 KVA of any make /type opening and throughly checking to carrying out repairs to the turbo charger assembly and replacing the turbo charger repair kit and mirror spares as required incl calibrating , servicing and assembling and fixing back the turbo charger assembly to its original position and testing complete all as specified and directed.
S&F in repair piston Assembly (one piston with ring) for 320 KVA DG set including taking down existing one.
S&F Electrically insulated PVC synthetic mat of nominal thickness 2.5 mm class B voltage uoto 11 kV conforming to IS 15652-2006 including taking down existing one and applying adhesive to fix before laying the new one complete all as specified and directed.
S&F first aid kit suitable for electrical installations having Metal cabinet of suitable size front side openable and First aid symbol and Words "FIRST AID KIT" marked on the front lid and mounting on wall with suitable fastners complete all as specified and directed by Engr-in-charge comprising with following items: (a) First Aid Book – 1, (b) Burn Cream – 1, (c) Antiseptic Cream 10g – 2, (d) Safety Pin 0 Size – 10, (e) Cotton Tip Applicator – 10, (f) Adhesive Plaster 19 X 72mm – 25, (g) Adhesive Plaster 25 X 72mm – 10, (h) Adhesive Plaster Round – 5, (i) Knuckle Plaster – 2, (j) Fingertip Plaster – 2, (k) Antiseptic Lotion 100ml – 1, (l) Tweezer – SS 7cm – 1, (m) Wound Cleaning Wipes – ALC – 10, (n) Antiseptic Wipes – 10, (o) Sterile Gauze Swab 10 Cm – 3, (p) Sterile Gauze Swab 7.5cm – 3, (q) Sterile Gauze Swab 5cm – 3, (r) Sterile Burn Dressing 5cm – 1, (s) Sterile Burn Dressing 10cm – 1, (t) Sterile Adhesive Plaster 6x10cm – 2, (u) Gauze Bandage 5cmx3mtr – 2, (v) Absorbent Cotton 20gms – 1, (w) Elastic Gauze Bandage 7.5x4m – 1, (x) Triangular Bandage – 2, (y) Sterile Dressing Medium – 3, (z) Sterile Oval Eye Pad – 2, (aa) Sterile Abdominal Pad 20x25cm – 1, (ab) Sterile Dressing Large – 3, (ac) Crepe Bandage 6cmx3mtr – 2, (ad) Haemostatic Absorbable Sponge – 1, (ae) Hand Sanitizer 50ml – 1, (af) Dusting Powder 10g – 1, (ag) Tincture Iodine 20ml – 2, (ah) Microporous Tape 1.25x5mt – 1, (ai) Pain Gel Cream – 1, (aj) Thermal Blanket – 1, (ak) Cotton Tape 1.25x1mt – 1, (al) Tourniquet Easy Usable – 1, (am) Scissor 5.5″ Tough Cut – 1, (an) Wooden Splint – 2, (ao) Torch Light with Battery – 1, (ap) Instant Cool Pack 50g – 2, (aq) Breathing Mask – 1, (ar) Gloves Examination – 2, (as) Sterile Cover for Amputated Part – 1, (at) Eye/Ear Drops – 1, (au) Electrolyte Powder 4.2gms – 5, (av) Asprin Tablet 75mg – 14, (aw) Paracetamol Tablet 500mg – 10, (ax) Plastic Glass – 1, (ay) Soft Stretcher – 1, (az) Digital Infrared Thermometer
Suchit constructions
Rama Electricals
ASHWAMEDH ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .