Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC | ₹32.5 L Quoted ₹33.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹34.5 LRejected-Finance 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹34.5 L | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹35.0 LRejected-Finance | ₹35.0 L | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹41.8 LRejected-Finance 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹41.8 L | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹42.6 LRejected-Finance | ₹42.6 L | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/s Luxmi Constructions L2 | Sukhmander Singh Contractor L1 | FATEH ENTERPRISES L3 | REYANSH GARG AND COMPANY L5 | SHARDA ENTERPRIES L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00SCH 'A' PART - I (BUILDING WORK B/R-II PORTION) | ||||||||
| 1.00 | Taking down cement or cement lime plaster of any description and any thickness on brick, concrete or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engineer in Charge. | 1,000 | SQUARE METRE | 18 ₹18,000 | 10 ₹10,000 | 12 ₹12,000 | 70 ₹70,000 | 15 ₹15,000 |
| 1.00 | M&L for rendering 15 mm thick cement plaster in CM (1:4) on fair faces of brick or concrete surfaces and finishing the surface even and fair etc, complete all as specified and directed by Engineer in Charge. | 400 | SQUARE METRE | 162 ₹64,800 | 200 ₹80,000 | 210 ₹84,000 | 250 ₹1 L | 280 ₹1.1 L |
| 1.00 | M&L for rendering 15 mm thick cement plaster in CM (1:6) on fair faces of brick or concrete surfaces and finishing the surface even and fair etc, complete all as specified and directed by Engineer in Charge. | 420 | SQUARE METRE | 144 ₹60,480 | 200 ₹84,000 | 200 ₹84,000 | 250 ₹1.1 L | 260 ₹1.1 L |
| 1.00 | M&L for rendering 5 mm thick cement plaster in CM(1:3) on fair faces of concrete surfaces in ceiling, complete all as specified and directed by Engineer in Charge. | 50 | SQUARE METRE | 144 ₹7,200 | 100 ₹5,000 | 220 ₹11,000 | 160 ₹8,000 | 260 ₹13,000 |
| 1.00 | M&L for rough cast plaster on brick wall consisting under coat of cement and sand mortar (1:4) not less than 10mm thick and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel mixed with coarse sand and cement in the ratio 1:1:1 shall be applied and finish even, complete all as specified and directed by Engineer in Charge. | 100 | SQUARE METRE | 333 ₹33,300 | 270 ₹27,000 | 200 ₹20,000 | 380 ₹38,000 | 260 ₹26,000 |
| 1.01 | M&L for complete removal of existing treatment from walls, pillars, cornices upto plaster surface by electric sand paper grinder, washing, rubbing down and stopping of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces finally rubbed and smooth with sand paper and applying two coat of premium quality exterior emulsion paint over priming coat of exterior primer, complete all as specified and directed by Engineer in Charge. | 540 | SQUARE METRE | 54 ₹29,160 | 30 ₹16,200 | 65 ₹35,100 | 60 ₹32,400 | 85 ₹45,900 |
| 1.01 | M&L for preparation new wall surface for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed by Engineer in Charge. | 500 | SQUARE METRE | 54 ₹27,000 | 50 ₹25,000 | 60 ₹30,000 | 120 ₹60,000 | 55 ₹27,500 |
| 1.01 | M&L for preparation of new plastered surfaces of Ceiling and applying three coats of white wash on Ceiling, complete all as specified and directed by Engineer in Charge. | 50 | SQUARE METRE | 18 ₹900 | 10 ₹500 | 8 ₹400 | 30 ₹1,500 | 20 ₹1,000 |
| 1.01 | M&L for Complete removal of existing treatment and preparation of old plastered /unplastered surfaces of Ceiling and applying three coats of white wash on Ceiling, complete all as specified and directed by Engineer in Charge. | 350 | SQUARE METRE | 18 ₹6,300 | 20 ₹7,000 | 10 ₹3,500 | 30 ₹10,500 | 20 ₹7,000 |
Tender Value
Refer Docs
EMD Value
₹87,400
Closing Date
15 Oct 2025, 6:00 pmClosed
GE (AF) BHISIANA
GE (AF) BHISIANA PIN - 151201
ADDN/ ALTN TO CERTAIN SMQs AT AF STN BHISIANA
2025_MES_730776_1
GE/BHI/CAP-05/2025-26
Open Tender
Civil Works
183 days
GE (AF) BHISIANA
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) BHISIANA
₹87,400
Yes
10 Jan 2026
13 Sept 2025
17 Oct 2025
13 Sept 2025
15 Oct 2025
1 Oct 2025
13 Sept 2025 - 22 Sept 2025
Amount
SCH 'A' PART - I (BUILDING WORK B/R-II PORTION)
Taking down cement or cement lime plaster of any description and any thickness on brick, concrete or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engineer in Charge.
M&L for rendering 15 mm thick cement plaster in CM (1:4) on fair faces of brick or concrete surfaces and finishing the surface even and fair etc, complete all as specified and directed by Engineer in Charge.
M&L for rendering 15 mm thick cement plaster in CM (1:6) on fair faces of brick or concrete surfaces and finishing the surface even and fair etc, complete all as specified and directed by Engineer in Charge.
M&L for rendering 5 mm thick cement plaster in CM(1:3) on fair faces of concrete surfaces in ceiling, complete all as specified and directed by Engineer in Charge.
M&L for rough cast plaster on brick wall consisting under coat of cement and sand mortar (1:4) not less than 10mm thick and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel mixed with coarse sand and cement in the ratio 1:1:1 shall be applied and finish even, complete all as specified and directed by Engineer in Charge.
M&L for complete removal of existing treatment from walls, pillars, cornices upto plaster surface by electric sand paper grinder, washing, rubbing down and stopping of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces finally rubbed and smooth with sand paper and applying two coat of premium quality exterior emulsion paint over priming coat of exterior primer, complete all as specified and directed by Engineer in Charge.
M&L for preparation new wall surface for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed by Engineer in Charge.
M&L for preparation of new plastered surfaces of Ceiling and applying three coats of white wash on Ceiling, complete all as specified and directed by Engineer in Charge.
M&L for Complete removal of existing treatment and preparation of old plastered /unplastered surfaces of Ceiling and applying three coats of white wash on Ceiling, complete all as specified and directed by Engineer in Charge.
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash, complete all as specified and directed by Engineer in Charge.
M&L for Complete removal of existing treatment and preparation of old plastered /unplastered surfaces of walls and applying three coats of white wash, complete all as specified and directed by Engineer in Charge.
M&L for Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper acrylic, white or tinted over a coat of primer of same make, complete all as specified and directed by Engineer in Charge.
M&L for Complete removal of existing treatment and preparation of old plastered surfaces of walls and applying two coats of Oil bound distemper acrylic, white or tinted over a priming coat of same make on wall surfaces, complete all as specified and directed by Engineer in Charge.
M&L applying 1.5 avg mm thick wall care putty (JK/Birla/berger) on walls, including making surface even and smooth using sand paper before applying Priming coat, complete all as specified and directed by Engineer in Charge.
Demolition of reinforced cement concrete of any description and in any position, cut as required to facilitate demolition, complete all as specified and directed by Engineer in Charge.
M&L for reinforced cement concrete Type-B-1, 1:2:4 ) 20mm graded aggregate as in roofs, floors, kitchen platform, beams, lintels, Columns, shelves, staircase, landing, parapets and railings and with similar suspended works including necessary form work required at site and applying a coat of cement slurry over old surfaces of concrete to make perfect binding, complete all as specified and directed by Engineer in Charge.
M&L for providing precast cement concrete cover slabs using cement concrete Type B1, 1:2:4, (using 20 mm graded stone aggregate), for manholes etc and similar works, complete all as specified and directed by Engineer in Charge.
Formwork to chullah hoods, shelves, chajjas, troughs and similar items in flats including edges, complete all as specified and directed by Engineer in Charge.
M&L for mild steel TMT bars 8 to 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer in Charge.
All as per srl iten no 1.019 above but 6 to 8 mm dia.
S&F chicken wire mesh/ hard drawn wire fabric of weight not exc 4 kg per sqm, cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and directed by Engineer in Charge.
Demolition of cement concrete unreinforced of any description in any position not exceeding 150 mm thick (below or above ground level), complete all as specified and directed by Engineer in Charge.
M&L for 75 mm thick Plain Cement Concrete, 1:3:6, type C-1 (using 20mm graded stone aggregate) as in plinth protection finishing cement concrete surface even and fair without using extra cement, including making construction joint at a interval not exceeding 3.00 m and at each corner and filled with sealing compound with grade A(normal) in 25/30, complete all as specified and directed by Engineer in Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed by Engineer in Charge.
M&L for 25 mm thick cement concrete Type B1, 1:2:4, (using 20 mm graded stone aggregate), as in sub base of floor, complete all as specified and directed by Engineer in Charge.
M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. including 15mm thick screed bed in CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed by Engineer in Charge.
M&L for vitrified tiles 9 to 10 mm thick light shade (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM (1:6) for laying floor finishes, complete all as specified and directed by Engineer in Charge.
M&L for vitrified tiles 9 to 10 mm thick light shade (square/ rectangular) on vertical surfaces as in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick cement plaster in CM 1:4 to receive vertical tiles, complete all as specified and directed by Engineer in Charge.
M&L for Glazed ceramic coloured tiles in vertical surface 350x250x7 or of desire size mm thick including 10mm thick cement plaster in CM 1:4 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specified and directed by Engineer in Charge.
Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar, complete all as specified and directed by Engineer in Charge.
M&L for Granite (of any Type) work table rubbed and polished 18 mm thick machine cut, in steps, jams, pillars, window cills, cooking platforms and like laid and bedded over 15 mm thick cement mortar in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, including making 01 x hole for gas pipe in each cooking platform, complete all as specified and directed by Engineer in Charge.
Rounding the edge of stone slabs one edge such as in steps, cooking platforms, and the other similar situation, complete all as specified and directed by Engineer in Charge.
M&L machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over 15mm thick screed bed of CM 1:4 including rubbing and polishing, complete all as specified and directed by Engineer in Charge.
M&L machine cut kota stone slab 14-16 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and cement slurry including 10mm thick cement plaster 1:3 CM to receive kota stone and jointed rubbing and polishing, complete all as specified and directed by Engineer in Charge.
Demolition of cement concrete (unreinforced) exc 15 cm thickness but above ground floor, sunkan floor, complete all as specified and directed by Engineer in Charge.
M&L for 15 mm thick rendering in cement mortar (1:3) as in sunken portion walls and floor, mixed with water proofing compound 3% by weight of cement, finishing surfaces even & smooth without using extra cement, complete all as specified and directed by Engineer in Charge. Note:- water proofing compound shall be measured and paid under appropriate item of this Sch ‘A’.
Supply only integral water proofing compound, mixed as per instruction given over as per manufactures direction, complete all as specified and directed by Engineer in Charge.
M&L for bitumen hot blown any grade, applied hot, in two coats to concrete surfaces at the rate of 1.5 Kg per Sqm per coat, including cleaning of surfaces, complete all as specified and directed by Engineer in Charge.
M&L for laying 50 micron polyethylene film, black in floors of sunken, complete all as specified and directed.
M&L for Plain Cement Concrete, 1:5:10, type E-2 (using 40mm graded stone aggregate) as in filling of sunken floor and mass concrete, complete all as specified and directed by Engineer in Charge.
M&L for 50 mm dia GI spought pipe fixed in sunken floors by means of cutting holes in wall/ taking down old u/s pipe, fixed and bedded in cement mortar/PCC (1:2:4) and making good the disturbed portion of wall, complete all as specified and directed by Engineer in Charge.
S&F in repair PVC (SWR) floor trap 75mm, plain with grating including jointing with solvent cement, complete all as specified and directed by Engineer in Charge.
S&F in repair stack clamp for 75 mm bore pipe out of 50 mm by 5 mm flat iron and 16 round round iron stay including bolt and nuts and securing ends of stay to walls or roof, complete all as specified and directed by Engineer in Charge.
S&F in repair stack clamp for 100 mm bore pipe out of 50 mm by 5 mm flat iron and 16 round round iron stay. Including bolt and nuts and securing ends of stay to walls or roof, complete all as specified and directed by Engineer in Charge.
Dismantling of drain pipes including all fittings (AC/PVC) fixed wall/trenches upto 110mm dia, complete all as specified and directed by Engineer in Charge.
S&F 110 mm bore PVC (SWR) pipes Medium duty single socketed in any length with rubber ring joints fixed to walls/floor with and including taking out of old outlet pipe etc, complete all as specified and directed by Engineer in Charge.
S&F 110 mm bore PVC (SWR) bends any radius, complete all as specified and directed by Engineer in Charge.
S&F 110mm PVC (SWR) branch piece, single (single Y) equal or unequal, complete all as specified and directed by Engineer in Charge.
S&F 75 mm bore PVC (SWR) pipes (Medium duty) single socketed in any length with rubber ring joints fixed to walls/floor with and including taking out of old outlet pipe etc, complete all as specified and directed by Engineer in Charge.
S&F 75 mm bore PVC (SWR) bends any radius, complete all as specified and directed by Engineer in Charge.
S&F 75mm PVC (SWR) branch piece, single (single Y) equal or unequal, complete all as specified and directed by Engineer in Charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store, complete all as specified and directed by Engineer in Charge.
M&L 15 mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed by Engineer in Charge.
Fixing only 15 mm dia steel tubes any grade to walls and ceilings or laying in floors, including new fittings as required, complete all as specified and directed by Engineer in Charge.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store, complete all as specified and directed by Engineer in Charge.
M&L 20 mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed by Engineer in Charge.
Fixing only 20 mm dia steel tubes any grade to walls and ceilings or laying in floors, including new fittings as required, complete all as specified and directed by Engineer in Charge.
Cutting chases, pining in making good to facing where required and pointing in cement mortar 1:3 for concealed water tubing, cutting not exc 10 cm girth, complete all as specified and directed by Engineer in Charge.
Dismantling PVC water tanks Exc 250 Ltr and n exc 500 Ltr and removing to store, complete all as specified and directed by Engineer in Charge.
M&L for three layered white colour Rotational moulded polyethylene water storage tanks of 500 ltr Capacity (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, complete all as specified and directed by Engineer in Charge.
M&L for 20mm Ball valves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed as in repairs, complete all as specified and directed by Engineer in Charge.
M&L for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed Screwed both ends for iron pipes or for union and fixed in repair to 20mm dia of pipe, complete all as specified and directed by Engineer in Charge.
M&L for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed Screwed both ends for iron pipes or for union and fixed in repair to 15 mm dia of pipe, complete all as specified and directed by Engineer in Charge.
M&L for Vitreous china squatting pan, 'Orissa' pattern, size 580 x 440 mm white, with integral foot rests complete including connection to trap and to flushing pipe, anti-syphonage pipe, etc fixed as in repairs, complete all as specified and directed by Engineer in Charge.
Supply only PVC (SWR) 'P’ trap 100 mm bore, complete all as specified and directed by Engineer in Charge. Note:- Rate for fixing deemed to be included in the Quoted Unit Rate of item No 1.64
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass corner shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed by Engineer in Charge.
Supply only PVC valve less, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle, completewith flush pipe of polyethylene of low or high density or PVC 32 mm dia , including brackets/ fastening assesoriesof 10 litres capacity, fixed in repair, complete all as specified and directed by Engineer in Charge. Note:- Rate for fixing deemed to be included in the Quoted Unit Rate of item No 1.64
S&F in repair for mirror cabinet of min size 430x330 mm with openable door shutter as approved by GE, complete all as specified and directed by Engineer in Charge.
S&F Vitreous China wash basin, white , flat back, size 550x400mm fixed on brackets or stands, including 32 mm waste coupling of PTMT (half or full threaded)/ CP Brass and corrugated waste pipe with adopter of 900 mm long, fixed in repair, complete all as specified and directed by Engineer in Charge.
S&F in repair wash hand basin Brass CP mixture 15mm bore for mixing hot and cold water screwed down for 15 mm iron pipe and fixed, complete all as specified and directed by Engineer in Charge.
S&F wash hand basin Brass CP mixture 15mm bore for mixing hot and cold water screwed down for 15 mm iron pipe and fixed, complete all as specified and directed by Engineer in Charge.
S&F in repair 15 mm dia bore CP angular stop cock/angle cock with wall flange cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union, complete all as specified and directed by Engineer in Charge.
S&F in repair 15 mm dia bore CP concealed stop cock/ angle cock cast copper alloy chromium plated with long sahnk, fancy type, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union, complete all as specified and directed by Engineer in Charge.
S&F Aqua guard nozzle tea valve fixing with 15mm bore GI pipe, complete all as specified and directed by Engineer in Charge.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 450mm, complete all as specified and directed by Engineer in Charge.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 600 mm, complete all as specified and directed by Engineer in Charge.
S&F in repair, 15 mm dia Bib taps, fancy type Chromium plated, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed by Engineer in Charge.
S&F in repair, brass CP Wall mixer 3 in 1, 15 mm bore, for mixing hot and cold water, screwed down for iron pipe, complete all as specified and directed by Engineer in Charge.
S&F brass CP Wall mixer 3 in 1, 15 mm bore, for mixing hot and cold water, screwed down for iron pipe and fixed, complete all as specified and directed by Engineer in Charge.
S&F in repair, 15mm bore wall mounted goose neck sink mixer (Hot and Cold) with provision of swivel arm, connecting legs and wall flanges, complete all as specified and directed by Engineer in Charge.
S&F 15mm bore wall mounted goose neck sink mixer( Hot and Cold) with provision of swivel arm, connecting legs and wall flanges, complete all as specified and directed by Engineer in Charge.
S&F in repair, Brass Chromium plated shower rose 125 mm size with or without swivel joints, including fixing to steel pipe or union, complete all as specified and directed by Engineer in Charge.
S&F in repair, stainless steel soap dish of size 115x85mm, complete all as specified and directed by Engineer in Charge.
S&F in repair, Brass CP tubular towel rail of 20 mm dia, D type, 60 CM long between flange, complete all as specified and directed by Engineer in Charge.
S&F Brass CP tubular towel rail of 20 mm dia, D type ,60 CM long between flange, complete all as specified and directed by Engineer in Charge.
S&F in repair, sinks made of stainless steel 1mm thick kitchen or labo-ratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm , including 40 mm bore dia CP waste coupling (half/full threaded with 900 mm and PVC waste pipe min 900 mm long, complete all as specified and directed by Engineer in Charge.
S&F in repair Kitchen Plate rack with of size 750x600x250mm of stainless steel, complete all as specified and directed by Engineer in Charge.
S&F Kitchen Plate rack with of size 750x600x250mm of stainless steel, complete all as specified and directed by Engineer in Charge.
S&F coat hooks of six pegs made out of stainless steel 45 cm long (as per sample), complete all as specified and directed by Engineer in Charge.
Dismantling of boarding in any position and in any description fixed with nail, complete all as specified and directed by Engineer in Charge.
S&F of 18 mm thick PVC ply of Plain colour fixed with screws, solvent cement/ adhesive to make cupboards, kitchen cabinet sides top and bottom and shelves inside the cabinets/ cupboards, complete all as specified and directed by Engineer in Charge.
S&F of 18 mm thick PVC ply of one side Prelam/Rigidlam and other side balancing laminate colour to make cupboard, kitchen cabinet Shutter/ drawer Front sides, complete all as specified and directed by Engineer in Charge.
S&F of 5 mm thick PVC ply of plain white colour fixed with screws, solvent cement/ adhesive to make cupboards, kitchen cabinet back covering and pull out drawer base, complete all as specified and directed by Engineer in Charge.
S&F for 20mm wide & 1mm thick PVC EDGE BEDDING of PVC pested on edges with suitable adhesive, complete all as specified and directed by Engineer in Charge.
S&F of Ball bearing runners 45 mm Telescopic Channel (20 Inch) full extension load capacity 50 kgs, complete all as specified and directed by Engineer in Charge.
S&F of stainless steel handles 100 mm size for kitchen cabinet shutters, complete all as specified and directed by Engineer in Charge.
M&L for Continuous piano hinges stainless steel, bright finish width of flaps when open 30 mm, complete all as specified and directed by Engineer in Charge.
S&F Hasp and staple safety type aluminium powder coated with mild steel pin including bolt to hinge plate and fix with screws 150 mm size of hasps and staples, complete all as specified and directed by Engineer in Charge.
S&F Magnetic catcher for cupboards, complete all as specified and directed by Engineer in Charge.
S&F in repair MS powder coated Curtain Rods 18 to20 mm bore over doors and windows, with fixing MS powder coated brackets, including screws,rawal plug and PVC powder coated fineals/ fancy type end bulbs at each end of curtains rod, any colour etc, complete all as specified and directed by Engineer in Charge.
Taking down Chowkhats or frames/ steel windows/ventilators, not exc 1.5 Sqm each (without taking off shutters from the frames), complete all as specified and directed by Engineer in Charge.
S&F steel window/ventilator of box section having 1.25 mm thick CRC sheet frame with double shutter inside gauged shutter and outside glazed shutter with one nos steel handle in each shutter, one nos peg stay in each shutter, complete with glazing bars and 08 Nos of 10 mm square guard bars in equal spacing, devoited or welded as per sample shown by Engr-in-Charge. (The rates includes 4 mm thick plain sheet glass and galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and 2 coat of synthetic enamel paint over a red oxide primer), complete all as specified and directed by Engineer in Charge. Note:- The design of window to be facilitated by cooler fixing provision where ever reqd.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length, complete all as specified and directed by Engineer in Charge. Note:- M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length, complete all as specified and directed by Engineer in Charge. Note:- M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed by Engineer in Charge. Note:- stainless steel butt hinges and necessary S S screws shall be paid separately.
Taking down chowkats & shutters without taking off shutters from the frame, size of opening exc. 1.50 sqm but not exc 4 sqm each, complete all as specified and directed by Engineer in Charge.
S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed of size 105 X 60mm, complete all as specified and directed by Engineer in Charge.
M&L for Plain Cement Concrete, 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in back of pressed steel chowkhats etc, complete all as specified and directed by Engineer in Charge.
M&L for Plain Cement Concrete 1:2:4, type B2 (using 20 mm graded stone aggregate) as in hold fast of steel chowkhat/ frames etc, complete all as specified and directed by Engineer in Charge.
S&F Factory made 35mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces using 2nd class HW as in rail and style. The size of rail and style as per IS-1003 (part – I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engineer in Charge.
S&F 35mm thick glazed and Skelton shutter IInd class hard wood ,open rebated and prepare to receive glass, gauge etc. (without sash bars) edge of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of member of shutters as specified in SSR part-1 , section 8 , clause 8.24(a), complete all as specified and directed by Engineer in Charge.
Taking down shutter of any description exc 1.00 sqm but not exc 2.0 sqm each and refixing in same opening after easing and adjusting (Chowkat/frame changed) etc, complete all as specified and directed by Engineer in Charge.
S&F floor door stopper of size 140 mm of aluminium ally body and tongue, anodised, with hard drawn steel spring fixed in floors, complete all as specified and directed by Engineer in Charge.
S&F mild steel 300mm ordinary rat tail rod pattern springs, including roller and roller plate fixed in repairs, complete all as specified and directed by Engineer in Charge.
S&F in repair of Aluminium body door cill upto 1mtr length at bottom part of door to stop entry of insect inside the room, complete all as specified and directed by Engineer in Charge.
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tack or galvanised wire staple, complete all as specified and directed by Engineer in Charge.
S&F in repair Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tack or galvanised wire staple, complete all as specified and directed by Engineer in Charge.
S&F 100 mm size hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21l butt hinges, complete all as specified and directed by Engineer in Charge.
S&F 100 mm extruded Aluminium alloy handles, fabricated type anodised, complete all as specified and directed by Engineer in Charge.
S&F 150 mm extruded Aluminium alloy handles, fabricated type anodised, complete all as specified and directed by Engineer in Charge.
S&F 150 mm extruded Aluminium alloy handles, fabricated type anodised, fixed in repair handles, complete all as specified and directed by Engineer in Charge.
S&F 150 Aluminium anodised barrel tower bolts of extruded section, complete all as specified and directed by Engineer in Charge.
S&F 150 Aluminium anodised barrel tower bolts of extruded section and fixed in repair tower bolt, complete all as specified and directed by Engineer in Charge.
Double action spring hinges, mild steel with steel wire spring, stove enamelled, black, complete all as specified and directed by Engineer in Charge.
S&F 300 mm aluminium ally, anodised , sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, complete all as specified and directed by Engineer in Charge.
S&F in repair 300 mm aluminium ally, anodised , sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, complete all as specified and directed by Engineer in Charge.
M&L applying Two coats of Synthetic enamel paint over a coat of pink primer including preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10 cm width or girth, complete all as specified and directed by Engineer in Charge.
M&L Preparation of old wooden surface and applying one coat of synthetic enamel paint, complete all as specified and directed by Engineer in Charge.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed by Engineer in Charge.
M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer exposed to view surfaces, complete all as specified and directed by Engineer in Charge.
M&L for preparation of old steel surfaces of any description not otherwise described over 10cm width or girth and applying one coats of synthetic enamel paint over, complete all as specified and directed by Engineer in Charge.
Taking down existing cement plaster/roof treatment including raking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed.
M&L for providing cement concrete type BO (1:2:4) 12.5 mm graded stone aggregate for providing slope, maintain level, roof kerbs or mud stops rounded or chamfered edges, complete all as specified and directed by Engineer in Charge.
M&L for 10mm thick Screed bed or bedding layer in cement mortar 1:4, laid on roof, mixed with water proofing compound when concrete is green, as per manufacturer instructions, complete all as specified and directed by Engineer in Charge. Note: - Water proofing compound shall be measured and paid separately.
Supply only integral water proofing compound, ISI marked, complete all as specified and directed by Engineer in Charge.
M&L for APP based polymeric membrane of minimum 3 mm thick and minimum weight not less than 3.0 Kg/sqm, reinforced with polyester non woven fabric matt (weight not less than 150 gm/sqm), laid with forced application over roof surface with a coat of hot blown bitumen conforming to IS-3384-1965 of grade 85/25 @ 1.2 kg/Sqm at bottom of the membrane as bonding material, complete all as per manufacturer's instructions, complete all as specified and directed by Engineer in Charge.
M&L for providing precast cement concrete louvers and jallies 25mm thick type B0 (1:2:4 using 12.5mm graded aggregate), (measured solid), including all mouldings etc, complete all as specified and directed by Engineer in Charge.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar, complete all as specified and directed by Engineer in Charge.
M&L for brick work with subclass B bricks, straight or curved on plan exc 6 m mean radius , built in cement mortar (1:6), complete all as specified and directed by Engineer in Charge.
M&L for brick work with subclass B bricks, straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4), complete all as specified and directed by Engineer in Charge.
SCH 'A' PART - I (BUILDING WORK E/M PORTION)
Taking down carefully copper/ aluminium point wiring (light fan socket or power) complete along with fittings such as switches, ceiling roses, Pendants regulators Tube fittings and other Kits & fittings/ conduit from surface /wall. Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface/ location, complete all as specified and directed by Engineer in Charge. Note:- Serviceable fitting/ fixtures will be reused in the work as directed by Engineer- in-Charge.
Taking down un-serviceable main switch, DB’s insulators, DB for MCB etc of any type and any capacity and further disposal including making good the disturbed surface and matching the colour of wall with the existing colour wash/ paint/ distemper wherever required (as per the existing), complete all as specified and directed by Engineer in Charge.
Taking down ceiling fan of any descriptions, servicing and repairs of fans as required, fixing back, connecting and testing the fan for its satisfactory function including making good the disturbed surface and matching the colour of wall with the existing colour wash/ paint/ distemper wherever required (as per the existing), complete all as specified and directed by Engineer in Charge.
S&F exhaust fans steel body AC single phase 230/ 240 V ,50 HZof size 300 mm sweep with louver, complete all as specified and directed by Engineer in Charge.
Taking down elect water heater of any descriptions, servicing and repairs (Including replacement of old pvc connection hot & cold 2 Nos & 4 Nos fasteners) of geyser as required, fixing back, connecting and testing the geyser for its satisfactory function including making good the disturbed surface and matching the colour of wall with the existing colour wash / paint / distemper wherever required (as per the existing), complete all as specified and directed by Engineer in Charge.
M&L for point wiring with FRLS PVC insulated unsheathed multi-stranded copper conductor 1.5 Sq.mm (nominal area) single core cable 1100 Volt grade drawn in and including rigid non metallic concealed PVC Conduit of suitable size (not less than 20 mm) on wall, surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes (Terminal boxes) with earth dolly, duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLS PVC insulated unsheathed stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable as earth continuity conductor to common earth and connected to earth dolly, complete all as specified and directed by Engineer in Charge.
All as per srl item No. 2.06 here-in-before but One light/fan point controlled by one 1-way switch
All as per srl item No. 2.06 here-in-before but One light/fan point controlled by two 2-way switch
All as per srl item No. 2.06 here-in-before but One 3/5 pin socket outlet, 5 Amp on independent board
All as per srl item No. 2.06 here-in-before but One 3/5 pin socket outlet, 5 Amp on same board
All as per srl item No. 2.06 here-in-before but One bell /buzzer point controlled by one push button on independent board
M&L for point wiring with FRLS PVC insulated unsheathed multi-stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawn in and including rigid non metallic concealed PVC Conduit on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes (Terminal boxes) with earth dolly, duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLS PVC insulated unsheathed stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable as earth continuity conductor to common earth and connected to earth dolly, complete all as specified and directed by Engineer in Charge.
Dismantling/ Taking down existing unserviceable sub main wiring from batten/ conduit of any size all as directed. Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface/ location, complete all as specified and directed by Engineer in Charge.
M&L for sub main surface wiring with PVC insulated unsheathed copper conductor cable of size 6 Sqmm single core through concealed rigid non-metallic PVC conduit of suitable size (Not less than 25 mm dia) in wall and surface of ceiling including 6 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly including making good the disturbed potion of wall, complete all as specified and directed by Engineer in Charge. Note:- Two run of 6 Sqmm copper cable one run of 6 Sqmm copper cable and PVC conduit will be measured as a single length.
S&F Switch Modular type, 6 Amp, 240 Volts , one way, complete all as specified and directed by Engineer in Charge.
S&F Switch Modular type, 6 Amp, 240 Volts , Two way, complete all as specified and directed by Engineer in Charge.
S&F Switch Modular type, 16 Amp,240 Volts , one way, complete all as specified and directed by Engineer in Charge.
S&F Socket outlet, Modular type, 6 Amp, complete all as specified and directed by Engineer in Charge.
S&F Socket outlet, Modular type, 6&16 Amp, complete all as specified and directed by Engineer in Charge.
S&F Bell Push, Modular type, 6 Amp, complete all as specified and directed by Engineer in Charge.
S&F Fan regulator, modular type electronic step type, complete all as specified and directed by Engineer in Charge.
S&F ceiling rose surface Bakelite two to three terminal 65x50 mm, complete all as specified and directed by Engineer in Charge.
S&F in replacement Tube light fittings LED type 1x20 Watt 4 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable, complete all as specified and directed by Engineer in Charge.
S&F in replacement Tube light fittings LED type 1X10 Watt, 2 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable, complete all as specified and directed by Engineer in Charge.
S&F in bell ding dong operating on AC 230/240 volt 50 HZ single phase, complete all as specified and directed by Engineer in Charge.
S&F MCB DB SPN 8 Way with acrylic double door, complete all as specified and directed by Engineer in Charge.
S&F including flushing in wall MCB distribution board vertical TPN 4 way 415 Volts AC double door type sheet steel phosphatised powder painted with bus bar neutral earth bar including provision of MCB TPN, FP 100 Amp conforming to IP 43 as incomer, complete all as specified and directed by Engineer in Charge.
S&F MCCB 4 pole 100 Amp 415 volt with breaking capacity of 16 KA, complete all as specified and directed by Engineer in Charge.
S&F MCB SPN 240V 40 Amps C series 10 KA, complete all as specified and directed by Engineer in Charge.
S&F MCB SP 240V 6 to 32 Amps C series 10 KA, complete all as specified and directed by Engineer in Charge.
Taking Down the KWH meter along with wooden board/DB after removing all electrical connection, complete all as specified and directed by Engineer in Charge.
Refixing & connecting the same or new serviceable KWH energy meter after wiring, complete all as specified and directed by Engineer in Charge.
S&F Sheet metal enclosure factory made of size 20cm x 25cm x 12.5 cm deep box made out of 2mm thick ms sheet with double door with locking arrangement , epoxy power coated holes drilled for cable entries suitable for accommodating electric energy meter including brick/cement works as per site requirement including flushing the box in wall and making good the disturbed portion of wall /surface, complete all as specified and directed by Engineer in Charge.
M&L for sub main surface wiring with PVC insulated unsheathed copper conductor cable of size 4 Sqmm single core through concealed rigid non-metallic PVC conduit of suitable size (Not less than 25 mm dia) in wall and surface of ceiling including 4 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly including making good the disturbed potion of wall, complete all as specified and directed by Engineer in Charge. Note:- Two run of 4 Sqmm copper cable one run of 4 Sqmm copper cable and PVC conduit will be measured as a single length.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, complete all as specified and directed by Engineer in Charge.
Taking down old U/S LT UG cable of any size from trenches/ pipe/ floor/ walls, complete all as specified and directed by Engineer in Charge.
Supply laying jointing cable XLPE insulated PVC sheathed strip wire armoured 1100 volt 4 core 25 sqmm multi stranded aluminium conductor laid in trenches/wall/ducts etcincluding necessary fixing arrangement such as cable lugs glands etc complete after removing/taking out extg unsv cable to the entire satisfaction, complete all as specified and directed by Engineer in Charge.
Excavation in trenches n.exc 1.5 mtr deep and n.exc 1.5 mtr wide getting out soil, complete all as specified and directed by Engineer in Charge.
Returning filling in including spreading leveling, watering and well ramming in layers, complete all as specified and directed by Engineer in Charge.
Removing excavated soil to a distance not exc. 50 mtr and depositing where directed, complete all as specified and directed by Engineer in Charge.
Supply and spreading dry sand in trenches for cushioning of cable, complete all as specified and directed by Engineer in Charge.
Supply and laying reinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm, complete all as specified and directed by Engineer in Charge.
S&F GI Tube light grade 50 mm dia as in cable protection pipe, complete all as specified and directed by Engineer in Charge.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2 mtr deep below ground level with top edgw of the plate not less than 1.4 mtr below normal ground level, connected earth wire 4 sqmm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit in PCC (1:3:6) type C-1 cast iron frame 50mm thick pre cast RCC (1: 1 1/2:3) nominal mix cover slab reinforced with 8 mm dia mild steel deformed bar 15cc and suitable handle of 10 mm Dia round bar including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc 50m and funnel with watering pipe wire mesh copper lugs etc GI protection pipe of size 15 mm bore including testing, complete all as specified and directed by Engineer in Charge.
M/s Luxmi Constructions (BID ID -3442557)
FATEH ENTERPRISES (BID ID -3451631)
SHARDA ENTERPRIES (BID ID -3451811)
REYANSH GARG AND COMPANY (BID ID -3445804)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid