| 1 | L1₹40.9 LAccepted-AOC FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹45.9 L+₹4.9 L (12.0%)Rejected-Finance 173 RASTA PETH NIKHIL APARTMENT SHIRAL SETH CHOWK PUNE 411011 | PUNE | MAHARASHTRA | 411011 | L2 | Rejected-Finance High Rate | |
| 3 | L3₹47.7 L+₹6.7 L (16.4%)Rejected-Finance | L3 | Rejected-Finance High Rate |
| Sl No | Description | Qty | Unit | M/S - SUJIT ELECTRICALS L2 | M/s Asrani and sons L3 | Chaulya Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling of existing UNSV Water coolers of any type and capacity Ltrs along with connected items and deposite to AGE E/M store Yard for further disposal. | 29 | Each | 250 ₹7,250 Lowest | 500 ₹14,500 | 500 ₹14,500 |
| 2.00 | Dismantling of existing UNSV Refrigerators any type and capacity along with connected items and deposite to AGE E/M store Yard for further disposal. | 13 | Each | 500 ₹6,500 | 350 ₹4,550 Lowest | 500 ₹6,500 |
| 3.00 | Supply, installation, testing and commissioning of a water cooler with a storage capacity of 150 liters and cooling capacity of 150 liters per hour. The unit shall have 1 normal and 2 cold taps, operate on a single-phase power supply, and include all necessary connections to the existing water tapping point. Additionally, proper arrangements for a drainage pipe shall be made to complete the setup model PC15150-3T Blue Star or equvalient as specified and directed by the Engineer-in-Charge. | 1 | Each | 70,000 ₹70,000 Lowest | 86,600 ₹86,600 | 70,000 ₹70,000 Lowest |
| 4.00 | Supply, installation, testing and commissioning of a water cooler with a storage capacity of 80 liters and cooling capacity of 120 liters per hour. The unit shall have 02 Nos of taps, operate on a single-phase power supply, and include all necessary connections to the existing water tapping point. Additionally, proper arrangements for a drainage pipe shall be made to complete the setup model SDLX80120 Bluestar or equvalient as specified and directed by the Engineer-in-Charge. | 2 | Each | 58,500 ₹1,17,000 | 69,400 ₹1,38,800 | 55,000 ₹1,10,000 Lowest |
| 5.00 | Supply, installation, testing and commissioning of a water cooler with a storage capacity of 80 liters and cooling capacity of 40 liters per hour. The unit shall have 02 Nos of taps, operate on a single-phase power supply, and include all necessary connections to the existing water tapping point. Additionally, proper arrangements for a drainage pipe shall be made to complete the setup model SDLX4080 or equvalient as specified and directed by the Engineer-in-Charge. | 26 | Each | 40,500 ₹10,53,000 Lowest | 53,000 ₹13,78,000 | 42,000 ₹10,92,000 |
| 6.00 | Supply and fix refrigerator, electric driven (single phase), capacity 310 litres or above, 5 star rated with stablizer all as per directed and sample approved by EIC. | 13 | Each | 29,200 ₹3,79,600 Lowest | 40,000 ₹5,20,000 | 50,000 ₹6,50,000 |
| 7.00 | Supply and Fixing Voltage Stablizer for AUTOMATIC OPERATION 1 Phase naturally air cooled indoor type and design and input variation between 170 volt to 250 volt with output voltage stablized at 230volt with accuracy +/- 2.5% and of capacity 1 KVA complete , V Guard VG 400 or equvilent all as specified and as directed | 29 | Each | 2,850 ₹82,650 | 2,260 ₹65,540 Lowest | 3,200 ₹92,800 |
| 8.00 | Supply, installation, testing, and commissioning of a Walk-in Cold Room for medical storage of nominal size 9' x 9' x 9' (dimensions provided are tentative and may vary based on ground conditions and as directed by the Engineer-in-Charge). The unit is designed for a maximum ambient temperature of 40°C and an internal temperature of 4°C ± 2°C. Walk-in-cold room walls and ceiling panels made of PPGI sheets filled with 60 mm PUF insulation, Anti-skid aluminum checkered plate flooring, door of suitable dimensions with, Anti-condensation door heater, Padlock system, door closer, safety release knob. the system will be equipped with digital temperature indicator-cum-controller. Two voltage stabilizers of suitable size for both units, sequential relay to control the start/stop operation of both units, appropriate internal lighting arrangement. Refrigeration System consisting of evaporator and condenser units: Split-type, air-cooled Power supply: 230V, single-phase, 50 Hz, Refrigeration capacity: 10,000 BTU/hr x 2 units (1 working + 1 standby) at 4°C room temperature and 35°C ambient temperature, Refrigerant: R-404 A. Material and labor for fixing of appropriate inlet/outlet refrigerant piping and wiring up to 7 meters included. Additional Work - Careful removal of the existing walk-in cold room (any type/size/make) and transporting it to the E&M store yard included in the above job, complete as specified and directed by the Engineer-in-Charge. | 1 | Each | 7,75,000 ₹7,75,000 | 7,41,000 ₹7,41,000 | 7,00,000 ₹7,00,000 Lowest |
| 9.00 | Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with any type of unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge. | 11 | Point | 15 ₹165 | 40 ₹440 | 10 ₹110 Lowest |
| 10.00M & L for concealed point wiring in wall and floor with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit including accessories/ fittings such as junction boxes, bends, tee, elbow etc alongwith Modular sunken boxes including modular frame / cover plate suitable for mounting switches /sockets etc including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:- | ||||||
Tender Value
₹49.6 L
EMD Value
₹99,200
Closing Date
19 Jun 2025, 6:00 pmClosed
Garrison Engineer (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
SPLECIAL REPAIRS/ REPLACEMENTOF CERTAIN COOLING APPLIANCES (WALK-IN-COOLER, WATER COOLERS REFRIGERATORS) AGAINST BER FOR VARIOUS DEPT OF AFMC PUNE AND ADDN/ALTN AND SPL REPAIRS TO BLDG NO P-182 AND P-219 AT AFMC PUNE UNDER GE (CENTRAL) PUNE
2025_MES_709742_1
8570 SPLECIAL REPAIRS/ REPLACEMENTOF CERTAIN COOLING APPLIANCES WALK- N COOLER, WATER COOLERS REF
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (Central) Pune
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer (Central) Pune
₹99,200
Yes
8 Aug 2025
22 May 2025
23 Jun 2025
22 May 2025
19 Jun 2025
5 Jun 2025
Amount
Dismantling of existing UNSV Water coolers of any type and capacity Ltrs along with connected items and deposite to AGE E/M store Yard for further disposal.
Dismantling of existing UNSV Refrigerators any type and capacity along with connected items and deposite to AGE E/M store Yard for further disposal.
Supply, installation, testing and commissioning of a water cooler with a storage capacity of 150 liters and cooling capacity of 150 liters per hour. The unit shall have 1 normal and 2 cold taps, operate on a single-phase power supply, and include all necessary connections to the existing water tapping point. Additionally, proper arrangements for a drainage pipe shall be made to complete the setup model PC15150-3T Blue Star or equvalient as specified and directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of a water cooler with a storage capacity of 80 liters and cooling capacity of 120 liters per hour. The unit shall have 02 Nos of taps, operate on a single-phase power supply, and include all necessary connections to the existing water tapping point. Additionally, proper arrangements for a drainage pipe shall be made to complete the setup model SDLX80120 Bluestar or equvalient as specified and directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of a water cooler with a storage capacity of 80 liters and cooling capacity of 40 liters per hour. The unit shall have 02 Nos of taps, operate on a single-phase power supply, and include all necessary connections to the existing water tapping point. Additionally, proper arrangements for a drainage pipe shall be made to complete the setup model SDLX4080 or equvalient as specified and directed by the Engineer-in-Charge.
Supply and fix refrigerator, electric driven (single phase), capacity 310 litres or above, 5 star rated with stablizer all as per directed and sample approved by EIC.
Supply and Fixing Voltage Stablizer for AUTOMATIC OPERATION 1 Phase naturally air cooled indoor type and design and input variation between 170 volt to 250 volt with output voltage stablized at 230volt with accuracy +/- 2.5% and of capacity 1 KVA complete , V Guard VG 400 or equvilent all as specified and as directed
Supply, installation, testing, and commissioning of a Walk-in Cold Room for medical storage of nominal size 9' x 9' x 9' (dimensions provided are tentative and may vary based on ground conditions and as directed by the Engineer-in-Charge). The unit is designed for a maximum ambient temperature of 40°C and an internal temperature of 4°C ± 2°C. Walk-in-cold room walls and ceiling panels made of PPGI sheets filled with 60 mm PUF insulation, Anti-skid aluminum checkered plate flooring, door of suitable dimensions with, Anti-condensation door heater, Padlock system, door closer, safety release knob. the system will be equipped with digital temperature indicator-cum-controller. Two voltage stabilizers of suitable size for both units, sequential relay to control the start/stop operation of both units, appropriate internal lighting arrangement. Refrigeration System consisting of evaporator and condenser units: Split-type, air-cooled Power supply: 230V, single-phase, 50 Hz, Refrigeration capacity: 10,000 BTU/hr x 2 units (1 working + 1 standby) at 4°C room temperature and 35°C ambient temperature, Refrigerant: R-404 A. Material and labor for fixing of appropriate inlet/outlet refrigerant piping and wiring up to 7 meters included. Additional Work - Careful removal of the existing walk-in cold room (any type/size/make) and transporting it to the E&M store yard included in the above job, complete as specified and directed by the Engineer-in-Charge.
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with any type of unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
M & L for concealed point wiring in wall and floor with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit including accessories/ fittings such as junction boxes, bends, tee, elbow etc alongwith Modular sunken boxes including modular frame / cover plate suitable for mounting switches /sockets etc including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:-
One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole.
One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
All as per item No 10 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S & F as in repairs modular switch 6A SP one - way 230V white ivory finish complete all as specified
S & F as in repairs modular switch 16A SP one - way 230V white ivory finish complete all as specified
S & F as in repairs modular socket outlet 2/3 pin 6 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified.
S & F as in repairs modular socket outlet 2/3 pin 16 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified.
M & L as in repairs for Sub main wiring complete with Two single core 6 sqmm and one core of 6 sqmm earth wire,1100volts FRLS grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor in and including PVC Conduit /casing caping including accessaries complete. (Note:- Making good of disturbed surfaces will be done by contractor without any claims.(ii) 3 runs of 6 Sqmm conductor and one run of PVC conduig/casing caping shall be measured as one unit length.)
S & F in replacement of LED light fittings 2'x2' of capacity 35/36 watts White/warm white LED surface/reccess environmental friendly, new genereation, aesthetically designed, ultra modern recess mounting luminaire with high brightness glare free soft illumination, white powder coated housing with LEDs, seamless front frame with flat white acrylic cover, 230 volts with all accessories internally pre wired and necessary mounting arrangements complete all as specified. .
Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 12 way complete all as specified and directed.
Supply & Fixing as replacement MCB SPN, 5 to 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,complete all as specified and directed.
Supply & Fixing as replacement MCB SP, 06 to 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked complete all as specified and directed.
Supply and fixing as in replacement of MCB TPN, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L brick work with flyash bricks straight or curved on plan exc 6 m mean raidus built in old size bricks cm 1:4 complete all as specified and directed.
Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L rendering 12 mm thick in CM 1:6 on fair face of brick /concrete surfaces of any description and finishing the surfaces even and smooth without using extra cement complete with complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer of same make over 2mm thick wall care putty complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces of walls / ceiling and applying two coats of oil bound distemper over a coat of primer of same make over 2mm thick wall care putty with and including complete removal of existing treatment of any layer of wall complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces of walls / ceiling and applying two coats of black oil synthetic painting over a coat of primer of same make over 2mm thick wall care putty with and including complete removal of existing treatment of any layer of wall complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
M&L for 40mm average thickness (1:2:4) Type-B-0 (using 12.5mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including Mirror polishing on Kota stone work where ever required to give high gloss finish complete complete complete all as specified and directed.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointedwith grey cement slurry mixed with pigment to match the shade of the slab including Mirror polishing on Kota stone work where ever required to give high gloss finish complete complete complete all as specified and directed.
M&L for glazed ceramic coloured, designer & pattern (dark & light shade combination) tiles in 450 x 300 x 7-8 mm thick on vertical surfaces such as dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match over with and including 10mm thick backing coat in CM 1:3 and d complete all as specified and directed.
Taking down chowkats or frames with shutter (without taking off shutter from the frames) n. exc 1.50 Sqm each with and including including making good the disturbed surfaces as original with CM (1:6) or PCC (1:2:4) type B0 complete all as specified and as directed.
Supply and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. Note: The unit rate quoted by contractor includes cost of glass and wire mesh and includes all other connected accessories. Before creation of doors, windows, ventilators and partitions (Fixed portions), the sample of all materials / accessories / hardware will be submitted to Engr-in-Charge for weighing of powder coated window section and approval of materials / accessories / hardware.
Dismantling of boarding, any description fixed in any position with nails i.e. false ceiling and wall lining etc and similar position fixed with screws complete.
S&F in true horizonal level false ceiling using non asbestos (fibre cement) pre-painted decorative tiles of size 595x595x4mm thick manufactured by V- Board or equivalent including GI snap grid of size (600x600)mm, using hot dipped galvanised steel section, exposed surface with pre-coated capping, main tee of size 24 x 38mm having 0.27mm gauge at every 1200mm, centre to centre maximum and rotary stitched cross tee of size 24x 32mm, having 0.25mm gauge at 1200mm c/c & Wall angle of size 19x 19mm, having 0.35mm gauge fixed to the periphery of the wall. The above grid is suspended at every 1200 mm c/c in both directions using 2.0 mm thick pre-straightened GI wire with and including dismantling of boarding, any description fixed in any position with nails i.e. false ceiling and wall lining etc and similar position fixed with screws complete.
Supply, testing, installation, designing, commissioning of the commercial chimany having Exhaust System wall side cooking kitchen & Exhaust System Centre cooking kitchen both are of size Approx (368 x 48x20) inch with the following accessories for each chimney (Wall side and Centre Cooking Exhaust System):- (a) Suction Area Dimensions approx (368 x 48) inch. (b) Suction Capacity: 10,000 CFM (c) Pressure: 50 MWG (d) Centrifugual Fan/Blower Motor- Capacity: Three-phase capacity 7.5 HP Speed: 1440 RPM (Rotations Per Minute) along with its starter, suitable size canvass/flexible bellow, viberation pad, Bird mesh, motor gaurd, Blower stand etc complete. (e) Provide bright and focused illumination for enhanced visibility, safety, and energy efficiency Long lifespan and low maintenance LED Lights in Hoods: Quantity: (24 pieces, Size: 8x8 inches) (f) Hood Dimensions: Dimensions approx (92 x 48) inch x 4 pieces of material Stainless Steel 304.
Contt.... (g) construction of baffle filters 2 folded system and handles, Stainless Steel 304 , 20 Nos (05 Nos for each hood). (h) Drain Gutter: With box for grease collection (j) All welded edges and surfaces to be properly and smoothly ground and finished, All burrs or sharp edges to be removed, Ensures high-quality, precise, and strong welds with minimal spatter (k) Surface Finish: Steel matt finish. All plain and pipe surfaces should have a brushed or PVC-coated surface for protection and durability. (l) Supply and Installation of GI factory made Ducting of 22 Guage of suitable size as approved by EIC.
NOTE : for ser No 38 Above (i) Work includes ladders, scaffolding, crane, civil work, painting, and electrical work and any support system required for ducting, including holding, hanging rods, and GI frames, will be part of the scope. (ii) All wiring and associated accessories from the designated take over point to the motors and LED lighting shall be deemed included in the scope of the work. (iii) Minor Changes in dimensions of ducting/hood may be done as per site requirements and Before placing an order, the drawing should be approved by the Engineer in Charge. (iv) The contractor shall produce a testing certificate for the chimney as per standard practice. (v) All materials (ducting,supportting structure), fabrication, and installations must comply with relevant industry standards regulations. (vi) All work shall be completed to the highest quality standards and in compliance with safety regulations.
M/S - SUJIT ELECTRICALS (BID ID -3320462)
M/s Asrani and sons (BID ID -3327593)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .