Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance VILL JIAR P O CHOURI TEH SUJANPUR DISTT HAMIRPUR H P | SUJANPUR | HAMIRPUR | HIMACHAL PRADESH | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹7.5 L
EMD Value
₹14,945
Closing Date
6 Oct 2022, 5:00 pmClosed
Executive Engineer T/well Divn Gagret
Executive Engineer T/well Divn Gagret
Drilling lowering of MSERW Pipes in various Tubewells under Jal Shakti Tubewell Division, Gagret(SH Providing and lowering of MSERW pipes of various dia and thickness) for Tubewell at Singhpura 125.00 mtr. Deep under Jal Shakti Division, Paonta etc
2022_HPIPH_65707_1
No.JSVTDG-CB-Tender/22- 1481-82 dated 28-09-2022
Open Tender
Civil Works
Item Rate
30 days
Tubewell at Singhpura
as per NIT
5 documents required · 5 mandatory
₹250
Yes
Executive Engineer T/well Divn Gagret
₹14,945
Yes
7 Oct 2022
29 Sept 2022
7 Oct 2022
29 Sept 2022
6 Oct 2022
29 Sept 2022
29 Sept 2022 - 6 Oct 2022
Amount
Providing and lowering of IS marked Electric Resistance welded M.S Pipe 300 mm nominal dia, size 8 mm thick having outside dia metre 323.90 mm with plain and bevelled end, confirming to IS 4270-2001 with up to date amendments (in any) about 4 metres to 7 metres in length, welded without any circumferential joints, into bore in vertical position including cost of all scaffolding derricks, poles, clamps embedded in foundation etc. including cost of all cutting threading and welding of pipes etc. within all leads and lifts, complete in all respecsts as per the direction of the Engineer-in-Charge.
Providing and lowering of IS marked Electric Resistance welded M.S slotted Pipe of 300 mm nominal dia size 8 mm thick with slot opening 1.57x0.75 mm as per IS 8110-1978, having outside diametre 323.9 mm, with plain and bevelled end confirming to IS 4270-2001 with up to date amendments (in any) about 4 metres to 7 metres in length, welded without any circumfrential joints, into bore in vertical position including cost of all scaffolding derricks, poles, clamps embedded in foundation etc. including cost of all cutting threading and welding of pipes etc. within all leads and lifts, complete in all respecsts as per the direction of the Engineer-in-Charge.
Providing and lowering of IS marked Electric Resistance welded M.S.Pipe 200 mm dia nominal size housing, 6.40 mm thick having outside dia metre 219.10 mm with plain and bevelled end, confirming to IS 4270-2001 with up to date amendments(in any) about 4 metres to 7 metres in length, welded without any circumferential joints, into bore in vertical position including cost of all scaffolding derricks, poles, clamps embedded in foundation etc. including cost of all cutting threading and welding of pipes etc. within all leads and lifts, complete in all respecsts as per the direction of the Engineer-in-Charge.
Lowering of IS marked Electric Resistance welded M.S. slotted Pipe of 200 mm dia nominal size, 6.40 mm thick with slot opening 1.57x0.75 mm, as per IS 8110-1978 having outside diametre 219.10 mm, with plain and bevelled end confirming to IS 4270-2001 with up to date amendments (in any) about 4 metres to 7 metres in length, welded without any circumfrential joints, into bore in vertical position including cost of all scaffolding derricks, poles, clamps embedded in foundation etc. including cost of all cutting threading and welding of pipes etc. within all leads and lifts, complete in all respecsts as per the direction of the Engineer-in-Charge.
M/S Sharma Enterpirses
Vats Associates
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .