Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC | L1 | Accepted-AOC 1st Lowest | |
| 2 | L2₹31.2 L+₹1.1 L (3.63%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹32.1 L+₹2.0 L (6.66%)Rejected-Finance | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹33.9 L+₹3.8 L (12.8%)Rejected-Finance | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹35.0 L+₹4.9 L (16.4%)Rejected-Finance | L5 | Rejected-Finance Higher bid value |
Tender Value
₹28.6 L
EMD Value
₹57,200
Closing Date
9 Jun 2020, 6:00 pmClosed
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
REPAIR_MAINT OF LT CONTROL PANELS AT SUB STN WATER SUPPLY INSTALLATIONS AND FEEDER PILLAR BOX AT RMS UNDER AGE EM OF GE 868 EWS
2020_MES_343521_2
8323/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Rangapahar
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
GE 868 EWS
₹57,200
Yes
25 Sept 2022
27 May 2020
11 Jun 2020
27 May 2020
9 Jun 2020
2 Jun 2020
27 May 2020 - 28 May 2020
Amount
Repair/maint of LT panel board by dismantling all cable connection i.e incoming and outgoings and trenching out of loop of cable by digging, cutting burnt portion of cable, cleaning and fixing of lugs with crimping tool, cleaning of bus bar with emery paper, tightening of bus bar with busbar insulators, re-fixing of cable with busbars, by providing new bolts, nuts and washers cable lugs to be provided for all incoming and outgoing cables all as specified and as directed.
M&L for spray painting to panel board (Inner & outer) with 2 coats of synthetic super enammelled paint, n.exc 2000mm x 1500mm x 600mm after rubbing and cleaning of existing paint, all as specified.
Labour only for removing of creepers grown along with LT panel board/feeder pillar boxes etc surface dressing ( n exc 25 Sq mtr) around the LT panel/sub station and inside the chain link fencing and removing all waste materials from site not exceeding 50mtr including supply and spraying chemical for destruction of grass all as specified and as directed.
Dismantling opening and taking out existing chain link/box type fencing including MS post/RCC post and re-fixing the same in vertical position and tightening to the chain link fencing complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks (Locally available best quality) straight or curved on plan to any radius in cement mortar (1:6) for of plinth of transformer or chain link fencing boundary, including earth work complete all as specified and as directed.
M&L for rendering 10mm thick plaster in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for PCC 1:3:6 type C-2 (Using 40mm gradded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for providing cement concrete Type B1 1:2:4 ( 20 mm graded aggregate) as in coping of poles including weathering, slightly rounded or chamfered angles and throating all as specified and as directed.
Dismantling, opening and taking out MS gate of any size , keeping aside for reuse , making good to disturbed pillar of the gate, grouting of hold fast , preparing the surface of gate for painting and painting with two coats of synthetic enamelled paint superior quality paint and reinstalling the MS gate after repair to its retrieved position all as specified and directed.
M&L for spray painting to chain link/MS box type fencing with two coat of synthetic enamelled aluminium paint including preparation of surface for painting all as specified and as directed.
S&F MCCB, 4 pole, 415V adjustable type 200 Amps with breaking capacity 36 KA all as specified and directed including taking down old one.
All as item No 11 here-in-before but capacity 250 Amp.
All as item No 11 here-in-before but capacity 400 Amp.
All as per item No 11 abve but 163 Amp 25 KA.
S&F MCCB, 3 pole, 415V adjustable type 63 to 100 Amps with breaking capacity 16 KA including taking down old one all as specified and directed.
M&L for laying & testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable Heavy duty with stranded aluminium conductor 1100 volts grade of size 185sqmm 3.5 core all as specified and as directed.
All as per item No 16 but of size 70 sqmm
All as per item No 16 but of size 50 sqmm
All as per item No 16 but of size 35 sqmm
M&L for laying & testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty with stranded aluminium conductor 1100 volts grade of size 16 sqmm 2 core all as specified and as directed.
All as per item No 20 but of size 10 sqmm
S&F energy saving envirnmental friendly die-cast aluminium IP-66 flood light of capacity 90 Watts 5700 K with high power LEDs suitable for single phase 50 Hz AC electric supply including taking down old unsv HPSV/FTL flood lights all as per specified and as directed. Make: Havells cat part No ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO or equivalent in Bajaj/CG.
All as per item No 22 above but cap 70 watts . Make : Havells Cat No ENDURACITYLINERNEOSL70WLED757PASYBOTG or equivalent in Bajaj/CG.
All as per item No 22 above but cap 48 watts . Make : Havells Cat No ENDURAPEARLNEOSL48WLED757PASYTOPC or equivalent in Bajaj/CG.
Material and labour for GI tubing light grade 50 mm bore under road crossing/ on pole for protection of cable all specified and as directed.
All as per item No 25 above but of 80 mm bore
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth strip 32mmx6mm by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm bore light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm bore med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification.
Supply, install, test and commission out door type feeder pillar boxes 600mmx600mmx500mm (Bus bar chamber) with aluminium bus bar 400 amps - 04 Nos fixed over epoxy insulators and outer shell made out of 3.15 mm thick MS sheet supported with MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 90 cm above and 45 cm below the ground level, frame factory fabricated with front openable single door ( door hinged with body at 4 places with hinges ) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93, all as specified.
Excavation in trenches, not exceeding 1.5 m wide and n.exc 1.50 m in depth for foundation etc or for shafts,wells,cesspits, manholes etc n.exc 10 sqm in plan and n.exc 1.5 m in depth and getting out in soft/loose soil.
Returning filling in including spreading, leveling,watering and well ramming in layers not exc 25 cm.
Removing excavated material n.exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point.
M & L for sand cushioing to the full width of trenches for protection of cables and filling under floor including spreading watering and punning down upto 18 cm and consolidation complete all as specified and as directed by Engr-in-charge (.Note :- Only punned down volume of sand to be measured.)
Material and labour for bricks class designation 75, old size, flat, common clay laid in trenches across the trench as cable protection.
Taking out old U/S PVC XLPE cable HT LT of size 35 Sqmm to 120 Sqmm 3/3.5 core all as specified and as directed. (NOTE : Excavation & earth workshall be measured and paid separately)
Taking out existing PVC/ XLPE LT electric cable of size 35 Sqmm to 95 Sqmm 3.5/4 core and shifting the same toother location for relaying including testing all as specified and as directed. (NOTE : Excavation & earth workshall be measured and paid separately)
All as per item No 38 above but 120 to 240 Sqmm
Cutting of existing roads for laying of under ground cable and making good to disturbed surface as per existing specifications not exceeding 0.9 mtr in depth all as specified and as directed.
M&L for replacement of danger notice plate 1.6mm thick mild steel sheet viterous enamelled white with letters ,figures and skull and bones in red colour and fixed to LT electric panel with revets all a sspecified.
Taking out existing LT electrical panel from foundation after disconnection of all incoming and outgoing electric cables incl earthing lead and removing the cable from panel board and removal/demolition of PCC from the footing of the panel (PCC n exc 0.50 cum) and placing the panel safely for reuse at same or other locations incl earthwotk complete all a sspecified.
M&L for replacement of angles bracing supports clamps and back plates fabricated from structural steel sections including nuts bolts washers welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one promer coat , one under coat and one finishing coat of synthetic enamel complete all as specified.
M&L for replacement of copper thimbles of size 25 to 50 Sqmm including crimping to the core of cable with help of crimping tools all as specified. Make : Dowells/Jainsons
All as item No 44 above but of size 95 to 150 Sqmm
All as item No 44 above but of size 185 to 300 Sqmm
S&F new spacer 2 way PVC flat/ clamp/ twisted type LT with nuts, bolts of suitable size for fixing with existing conductor complete including taking down old UNSV spacer.
All as per item No 47 above but 3 way
All as per item No 47 above but 4 way
M/s K P Enterprises
M/S UNITED CONSTRUCTION WORKS
Feroz Alam Khan
M/S ORIENTAL MOTORS COMPANY
VAISHNO ASSOCIATES
commercial enterprises
m/s chakraborty enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .