Loading…
Loading…
Tender ID
Tender Value
₹99.3 L
EMD Value
₹2.0 L
Closing Date
4 May 2026, 6:00 pmClosed
EXECUTIVE ENGINEER UIT BHILWARA
EXECUTIVE ENGINEER UIT BHILWARA
Sukhadiya Stadium ke Cricket Ground me Ratri Meacho ke Liya Flood Light Lagane Ka Karya
2026_UITBH_548927_11
NIT-59/2025-26 UIT BHILWARA
Open Tender
Electrical Works
Percentage
120 days
BHILWARA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Secretary UIT, Bhilwara/MD RISL Jaipur
₹2.0 L
Yes
30 Mar 2026
30 Mar 2026
6 May 2026
30 Mar 2026
4 May 2026
30 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SITC of 30 meter Stadium mast in three sections including headframe suitable for wind speed 50 m/sec. and suitable to install 28 nos. of LED luminaries in asymmetrical arrangement Minimum Lux level of 500 Lumens on Cricket field accessories including ladder ,rings for protection around the ladder and other manufactured items & necessary hardware’s including foundation aviation light etc. All the cables from fixtures to the mast on the head frame should be inside the flexible steel conduit pipe , complete in all respect. Specification of the Stadium mast as mentioned below . Make : Philips , Surya , GE . | |||||
| 2Providing & Fixing of IP66 protected high power LED flood light system with pressure die cast housing, toughened glass/IP Lens diffuser with suitable lens cluster for optimum light distribution to achieve beam angle of 30/60 degree, 240 volts AC, 50 Hz, of high power LEDfixture supplied with prewired cable. integrated driver shall be of high efficiency more than 85%. The system level luminaire efficacy >/= 135 lumen / watt with high power LED of CREE / NICHIA / OSRAM / PHILIPS / SEOUL make is to be used. Input Voltage 130V- 270 V AC, Power Factor >0.95, Frequency 50 Hz (+/- 3%), THD < 10%, Colour Temperature 5700 K, CRI > 70, Ingress Protection IP66, Impact Resistance IK 05, Surge Protection Minimum 5 KV internal and 10 KV external. Life expectancy equal to or more than 50000 burning hours withminimum 70% lumen maintenance. Mark / Brand to be engraved / embossed on die cast housing. The manufacture should have NABL accredited lab with photo metric testing facility. HIGH POWER LED FLOOD LIGHT 500 W, Make Surya, Philips GE | |||||
| 3Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
| 3.1 | 3 x 2.5 sq.mm | - | Mtr. | - | - |
| 4Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
| 4.1 | 35.0 Sq. mm | - | - | - | - |
| 4.2 | 3.5 core | - | Mtr | - | - |
| 5SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- | |||||
| 5.1 | (a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided | - | - | - | - |
| 5.2 | (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.43 MB
Tendernotice_2.pdf
PDF • 0.23 MB
Tendernotice_3.pdf
PDF • 3.92 MB
Tendernotice_4.pdf
PDF • 0.92 MB
Tendernotice_5.pdf
PDF • 0.13 MB
Tendernotice_6.pdf
PDF • 2.92 MB
BOQ_978568.xls
BOQ • 0.35 MB
11-Condition-Sukhadia.pdf
Tender Documents • 3.28 MB
Corigundom-59-11.pdf
PDF • 0.10 MB
Cori-Date-02.pdf
PDF • 0.07 MB
Date.pdf
PDF • 0.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .