Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 42A NEAR ALOK SCHOOL PANCHWATI UDAIPUR RAJASTHAN 313001 | UDAIPUR | RAJASTHAN | 313001 | Admitted-Finance |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
25 Mar 2021, 3:30 pmClosed
Executive Director Work, RTDC
RAJASTHAN TOURISM DEVELOPMENT CORRPORATION, JAIPUR
SITC 62.5 KVA D.G. set at Hotel Ghoomar Jodhpur
2021_RTDC_216959_1
NIT 06/2020-21
Open Tender
Civil Works
Percentage
30 days
Jodhpur
As per Bid Document
2 documents required · 2 mandatory
₹1,000
Executive Director Work, RTDC
₹10,000
Yes
25 Mar 2021
16 Mar 2021
25 Mar 2021
16 Mar 2021
25 Mar 2021
16 Mar 2021
Amount
SITC of Silent DG Set (As per CPCB norms) complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown). Engine shall have residential silencer, up to 3 M exhaust piping , electronic / Mechanical governor, Manual & electric Start ,Batteries, Engine instruments panel, AVM and with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mmCRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with 100mm thick glass wool(96Kg/m3)/Foam. as per IS 8183 the doors of 100 mm thick and fabricated from 1.6mm CRCA sheet packed with accoustic material, canopy fixed with axial flow fan , All doors/ opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 degree centigrade. All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring & control system, MCCB, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dBA at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity :Radiator Cooled & Turbo Charged /AC 62.5 KVA at 0.8 pf 415V 50Hz 3-ǿ Kirloskar( KOEL) Make including By Back old unserviceable DG Set 62.5 KVA of kirloskar make complete in all respect.
SARTHAK EQUIPMENT SOLUTIONS
Abha gensets
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .