Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.4 LAccepted-AOC 01 AGNI AUTOMATION AND SECURITY 01 KUNDAN BHAWAN SHIVAM VIHAR COLONY OPP KIET ENGG COLLEGE MURADNAGAR GHAZIABAD 201206 U P INDIA MURADNAGAR | GHAZIABAD | UTTAR PRADESH | 201206 | 1 | Accepted-AOC 1 | |
| 2 | 2₹13.9 L+₹43,322 (3.22%)Rejected-AOC MOHALLA MISHRANA PIHANI HARDOI | PIHANI | HARDOI | UTTAR PRADESH | 2 | Rejected-AOC 2 | |
| 3 | 3₹14.1 L+₹63,122 (4.70%)Rejected-AOC | 3 | Rejected-AOC 3 | |
| 4 | 4₹15.6 L+₹2.1 L (15.8%)Rejected-AOC 01 KATYANI CONSTRUCTION COMPANY H NO 1 SHOP NO 1 RATAN LAL NAGAR KANPUR NAGAR UTTAR PRADESH 208022 | KANPUR NAGAR | UTTAR PRADESH | 208022 | 4 | Rejected-AOC 4 | |
| 5 | Not Admitted-Fee | - | Not Admitted-Fee Insufficient Fee amount |
Tender Value
₹16.9 L
EMD Value
₹17,000
Closing Date
15 Feb 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC-I, Kanpur
SE ETC-I, Kanpur
Work
2022_UPTCL_675014_1
ET-107/ETC-I(K)/2021-22
Open Tender
Electrical Works
Fixed-rate
365 days
Kanpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,006
PNB Account No 0727002100004177
₹17,000
29 Jul 2022
21 Jan 2022
16 Feb 2022
21 Jan 2022
15 Feb 2022
21 Jan 2022
120 days
Amount
OPERATION
Monthly operation of 132/33 KV Substation round the clock in 03 shift of 08:00 hours each one helper in each shift for operation of substation equipments along with maintenance of records. (Annexure A-I).
Skilled Coolie/Helper, 04 No. (one in each shift & one for rest/leave period)
MAINTENCE
Preventive and breakdown maintenance of complete substation round the clock consisting of all type equipment, in 132/33kv Sub-station, such as transformers, CB,CT,PT,LA, Isolaters, Capacitor Bank, etc.The work involves regularly checking & tightening and replacement of all jumpers & replacement of damaged 132 & 33 kv CT/PT/LA/Isolator/33kv VCB Pole/Capacitor bank unit cells,VCB Tripping/Closing coil, and MCBs of CBs/Isolator jaw ,Blades if required including the adjustment a mechanism of CBs & Isolators, servicing & overhauling of cooling fan motor of Transformer etc, maintenance of fire equipment, cleaning of battery set, leveling of fluids and maintenance of gravity regarding battery parameters as per norms of department identification & rectification of fault of light HPSV & other lights in control room and switch yard to keep them in order. The above work carried out by following technical person. NOTE-Grinder (Cutter),Welding Machine and other all T&P must be provided by contractor during annual maintenance period.
TG-2 (ITI Electrical grade)-01 No.
Line Man/Technician-01 Nos.
Helper -02 Nos.
GENERAL CLEANING
General cleaning of floors in control room building, Toilet, wash basin by phenyl & wet cloth including cleaning of CC road drains in the periphery of substation.
Provide of Phenyle, Harpic, Colin Spray, Broom, Handwash etc. for general cleaning work every month by contractor.
LAWN MAINTENANCE
Regular monthly maintenance of lawn trees, shrubs, hedge, ground cover flower beds in lawn including weeding out of all undesired growth watching ,trimming, forking, making loose soil around plants and applying manure for survival and healthy growth of plants grass with fresh plant including cost of all T&P and skilled labour. Note- Trowel, Hoe, Hansia and 100mtr. hose pipe provided by contractor during Lawn maintenance period.
Supply of different type flower &18” size Cement flower pot alongside well rooted approx 30cm tall flower plant filled with soil and dung , manure & then painted with two coat good quality Red colour paint called Terracotta.
Cleaning of cable trenches of various sizes (200,400,600,800,1000 mm by removing earth deposit and other foreign material in bottom and over the cable racks including removal of cables from the racks and placing it outside trench carefully without causing any damage to cable, removal of trench cover and its fixing & all other associated works to complete the job satisfactorily.
Proper cleaning of complete yard( 132/33 kv) by cutting grass, Kansa and bushed by hansia4 times & Chemical spray 01time in a year as per technical specification and details enclosed. ( NOTE- The job includes disposing the grass at least 500mtr. away from the S/S premises.)
(1) Grass Cutting
(2) Chemical Spray
Refilling of mechanical foam type fire extinguishers including replacement of chemical & 300 gms./02 Kg CO2 Gas cartridge suitable for 50 ltr./09 ltr. capacity including replacement of hose & horn pipe & painting work & its testing including work of carriage from S/S to works & back.
Refilling of 27/11/4.5 Kg. CO2 type fire extinguishers including replacement of hose & horn pipe & painting work & its testing including work of carriage from S/S to works & back.
Miscellaneous work like Air Conditioning, T/Fs Cooling Fan Repairing etc.
Servicing & proper cleaning of filters, condenser coils, & fins of radiators, cooling chamber of radiator, air ducts with the help of air blower, pressurized water jet, Nirma powder along with checking of gas pressure with the pressure gauge toinsure the unit function properly. (split type AC 02 Ton capacity.).
Recharging of R-22 (Freon) Gas in sufficient quantity in compressor of 2 Ton window AC including cost of material and skilled labour.
Repairing of auto transformer and control circuit (PCB) and OEN relay of 15 A -230V voltage stabilizer.
Providing & fixing compressor of 2ton split type Hitachi make AC including dismantling & assembling.
Providing & Fixing MCB box 25A, 240V, 50Hz for 2 ton AC of Havells/ Anchor make.
COOLING FAN
Overhauling of 40 MVA T/Fs cooling fan motor having abnormal sound of size 450mm sweep, 1400 rpm, 3 phase 415volts including replacement of ball bearings and their oiling and greasing work along with demounting and mounting of fan and all the cable connection work complete in all respect.
Repairing and rewinding of burnt/damaged cooling fan motor of 450mm sweep, 3phase 415volts with replacement of their ball bearing complete in all respect along with dismantling and re-installation of fan on 40 MVA T/Fs including checking/termination of circuit of fan working on auto mode.
AWASTHI ENTERPRISES
N K MISHRA
Katyani Construction Co.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .