Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 CrAccepted-AOC 216 C SIVA COLONY MAYO LINK ROAD AJMER RAJASTHAN 305007 | AJMER | RAJASTHAN | 305007 | ₹24.3 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹24.6 CrRejected-Finance MANATHA ENCLAVE 3RD FLOOR OLIMUGAL KAKKANAD P O KOCHI 682 030 KERALA | ERNAKULAM | KERALA | 682030 | ₹24.6 Cr | L2 | Rejected-Finance NOT BEING L1 |
| 3 | L3₹25.4 CrRejected-Finance | ₹25.4 Cr | L3 | Rejected-Finance NOT BEING L1 |
| 4 | L4₹25.5 CrRejected-Finance | ₹25.5 Cr | L4 | Rejected-Finance NOT BEING L1 |
| 5 | L5₹27.8 CrRejected-Finance | ₹27.8 Cr | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹24.4 Cr
EMD Value
₹15 L
Closing Date
21 Feb 2022, 6:00 pmClosed
CHIEF ENGINEER CG GOA
HQ CE CG GOA 403806
CONSTRUCTION OF CGOM AT FORT KOCHI
2021_MES_494955_1
82040/E8
Open Tender
Civil Works
750 days
Kochi
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (I) (CG) KOCHI
₹15 L
Yes
25 Mar 2022
15 Dec 2021
22 Feb 2022
15 Dec 2021
21 Feb 2022
9 Feb 2022
Amount
SCHEDULE ‘A’ PART-I (BUILDING & STRUCTURE WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II ( SITE CLEARENCE, EXCAVATION AND EARTH WORK ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/HARDSTANDING/ OPEN PAVED AREA) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (SEA WALL ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX(HIGH SECURITY WALL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII (SOLAR HOT WATER SYSTEM) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII (FIRE FIGHTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIV (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XV (SUMMER APPLIANCE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XVI (STAINLESS STEEL BARRICADE RAILINGS) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII (LIFT & DG SET) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XIV (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
INTERNAL WATER SUPPLY Supply & fixing wall mixer Jaguar make ( CQT-CHR-23273G) equevlent with provision for over head shower with 115 mm long bend pipe on upper side, connecting legs, wall flenges & flow ristrictor of 2.5 LPM at 3 bar pressure complete all as specified 15 mm dia
Supply & fixing 15 mm dia regular body stop cock Jaguar make (ALD-CHR-089CQT) or equevlent with fitting sleeve etc complete screwed both ends for pipe or for unions and fixed suitable for 20 mm bore of pipe , complete all as specified.
Supply & fixing 15 mm dia regular body concealed stop cock Jaguar make (ALD-CHR-089CQT) or equevlent Exposed part kit Jaguar make ( CQT-CHR-23083K) or equevlent of concealed stop cock with fitting sleeve etc complete screwed both ends for pipe or for unions and fixed suitable for 20 mm bore of pipe , complete all as specified.
Supply & fixing 15 mm dia Jaguar make Angular stop cock ( CQT-CHR-23053) or equevlent complete all as specified.
Supply & fixing 15 mm dia Jaguar make 2 way bib cock ( CQT-CHR-23041GD) or equevlent with flow restrictor 3.8 LPM at 3 bar prssure complete all as specified.
Supply & fixing Over head shower 100 mm dia jaguar make ( OHS-CHR-1989GA) single flow (ABS body chrome plated with grey face plate) with rubit cleaning system and flow restrictor 6.0 LPM at 3 bar pressure and with shower arm (SHA-CHR-477P) with flege complete all asspecified.
Supply & fixing Jaguar make health faucet ( ALD-CHR-583GA) (ABS Body) with 1 Meter Long PVC Tube & Wall Hook) & Flow resrictor 6.0 LPM at 3 bars pressure or equevlent complete all as specified.
Supply & fixing 15mm dia Brass CP Wash hand basin mixer for hot & cold water, flow restrictor of 2.5 LPM at 3 bar pressure complete all as specified .
Supply & fixing of pvc flexible pipe connections complete all as specified 15mm dia.
INTERNAL ELECTRIC SUPPLY: S&F Ceiling fan 1200mm sweep, BLDC, 5 star rating including fixing of down rod and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 Sq mm from ceiling rose/ connector to fan all as specified and as directed.
S&F Exhaust fan copper winding, BLDC, 5 star rating 250 mm sweep 230 Volts AC 50 Hz PVC body with and including louvers complete all as specified and directed at site.
S&F Exhaust fan copper winding 5 star rating 450 mm sweep 230 Volts AC 50 Hz , 900 rpm heavy duty metal body with copper wound with and including louvers complete all as specified and directed at site.
S&F LED tube light fittings with lamp 1X40 Watts,extruded aluminium housing and diffuser, free illumination for continuous operation all as per cat No. BCLAB 40W WH LED P (cool white) of Bajaj or its equivalent make as mentioned in list of manufacturer all as specified and as directed.
S&F LED tube light fittings with lamp 1X20 Watts,extruded aluminium housing and diffuser, free illumination for continuous operation all as per cat No. BCLAB 20W WH LED P (cool white) of Bajaj or its equivalent make as mentioned in list of manufacturer all as specified and as directed.
S&F Surface mounted round LED down lighter with Al die-cast body, , finished with drop down PC diffuser to deliver low glare illumination with optimised heat sink for efficient heat dessipation as per cat No. BGSLO SLEEK SURFACE 15W WH RD ( white) of Bajaj or its equivalent make as mentioned in list of manufacturer all as specified and as directed. .
S&F Surface mounted square LED down lighter with Al die-cast body, , finished with drop down PC diffuser to deliver low glare illumination with optimised heat sink for efficient heat dessipation as per cat No. BGSLO SLEEK SURFACE 15W WH SQ ( white) of Bajaj or its equivalent make as mentioned in list of manufacturer all as specified and as directed. .
S&F Surface mounted square 1 X 1 LED luminaire with white powder coated CRCA housing, seamless front frame with flat white high transmission acrylic cover as per cat No. BZSSQL18W LED WH i ( white) of Bajaj or its equivalent make as mentioned in list of manufacturer all as specified and as directed. .
S&F Surface mounted square 4 X 1 LED luminaire with white powder coated CRCA housing, seamless front frame with flat white high transmission acrylic cover as per cat No. BZSSLL 36W LED WH i ( white) of Bajaj or its equivalent make as mentioned in list of manufacturer all as specified and as directed. .
S&F Bulk head luminaire with opal diffuser with energy saving new generation 10 Watt LED lamp, IP 65 protection as per cat No. BIBWP 10W LED (white) of Bajaj or its equivalent makes from list of makes all as specified and as directed.
S&F Multi purpose low highe bay application type LED fitting, 80 watts, with IP-65 protection as per cat No. BGPPR 80W LED VX of Bajaj or its equivalent make as mentioned in list of manufacturer all as specified and as directed. .
S&F TV socket including GI Box and modular inner and outer plate complete all as specified and as directed.(Make Crabtree Cat No. ACVKTOW001 or equivalent of Legrand)
S&F Telephone socket RJ-11including GI Box and modular inner and outer plate complete all as specified and as directed. Make Crabtree Cat No. ACVKRTW111 or equivalent of Legrand
S&F Cable tray for telephone wire using PVC rigid cable tray from grond floor junction box to all individual qtr of size A- 60x60 complete all as per Cat No. WWA6060SG of L&T or its equivalent make from list of makes all as specified and as directed.
S&Fn Cable tray for TV co axial wire using PVC rigid cable tray from grond floor junction box to all individual qtr of size B- 100x80 complete all as per Cat No. WWB10080SG of L&T or its equivalent make from list of makes all as specified and as directed.
S&F VTPN MCCB 250 A, 12 way distribution board, with 200 Amps rated bus bar, double door flush type as per IS 8623 with IP-54 protection, isolated neutral bars, door earthing, suitable for 4P MCCB of rating 250 A as incomer (frame F2) complete with all accessories all as specified and directed by Engineer-in Charge. Make: Indo Asian Cat No 812048 or equivalent in list of make enclosed
S&F VTPN MCCB 125 A, 8 way distribution board, with 200 Amps bus bar,double door flush type, with IP-54 protection, isolated neutral bars, door earthing, suitable for 4P MCCB of rating 125 A as incomer (frame F1) complete with all accessories all as specified and directed by Engineer-in Charge. Make: Indo Asian Cat No 812042 or equivalent in list of make enclosed
S&F VTPN MCCB 125 A, 4 way distribution board, with 200 Amps rated bus bar, double door flush type, with IP-54 protection, isolated neutral bars, door earthing, suitable for 4P MCCB of rating 125 A as incomer (frame F1) complete with all accessories all as specified and directed by Engineer-in Charge. Make: Indo Asian Cat No 812045 or equivalent in list of make enclosed
S&F SPN, 4 way MCB distribution board, with 200 Amps rated bus bar, double door flush type, with IP-54 protection, isolated neutral bars, door earthing, suitable for SPN/DP MCB/RCBO as incomer and SP MCB as outgoing complete with all accessories all as specified and directed by Engineer-in Charge. Make: Indo Asian Cat No.811824 or equivalent in list of make enclosed
S&F SPN, 8 way MCB distribution board, with 200 Amps rated bus bar, double door flush type, with IP-54 protection, isolated neutral bars, door earthing, suitable for SPN/DP MCB/RCBO as incomer and SP MCB as outgoing complete with all accessories all as specified and directed by Engineer-in Charge. Make: Indo Asian Cat No 811826or equivalent in list of make enclosed
S&F SPN, 12 way MCB distribution board, with 200 Amps rated bus bar, double door flush type, with IP-54 protection, isolated neutral bars, door earthing, suitable for SPN/DP MCB/RCBO as incomer and SP MCB as outgoing complete with all accessories all as specified and directed by Engineer-in Charge. Make: Indo Asian Cat No 811828 or equivalent in list of make enclosed
S&F MCCB, 4 pole, adjustable thermal setting type, confirm to IEC 60947-II, F2 frame of rating 250 A, breaking capacity 25 kA complete with all accessories all as specified and directed by Engineer-in Charge. Make: Indo Asian Cat No 830297 or equivalent in list of make enclosed
S&F MCCB, 4 pole, adjustable thermal setting type, confirm to IEC 60947-II, F1 frame of rating 125 A, breaking capacity 25 kA complete with all accessories all as specified and directed by Engineer-in Charge. Make: Indo Asian Cat No 830273 or equivalent in list of make enclosed
S&F MCCB, 4 pole, adjustable thermal setting type, confirm to IEC 60947-II, F1 frame of rating 100 A, breaking capacity 25 kA complete with all accessories all as specified and directed by Engineer-in Charge. Make: Indo Asian Cat No 830272 or equivalent in list of make enclosed
S&F MCCB enclosure sheet metal, powder coated suitable for frame 1 and suitable for 4 pole MCCB with all accessories all as specified and directed by Engineer-in Charge. Make: Indo Asian Cat No 811985 or equivalent in list of make enclosed
S&F MCCB enclosure sheet metal, powder coated suitable for frame 2 and suitable for 4 pole MCCB with all accessories all as specified and directed by Engineer-in Charge. Make: Indo Asian Cat No 811987 or equivalent in list of make enclosed
External Water Supply: Supply and fix Cast iron air release valve with 50 mm bore and two outlets as per IS:14845.
M & L Valve chamber of internal size 1.20 m X 1.20 m X 1.20 m (internal dimentions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation , brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to both internal and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The estimated cost includes all earthwork and connected items.
External Electric Supply: Supply, installation, and Commissioning of cubicle type, floor mounting totally enclosed outdoor weather proof powder coated CRCA sheet steel enclosure with provision for mounting 3 No. resin cast indoor type single phase CT's of ratio 60/5A, 1 No. resin cast indoor type 3 phase PT, Provision for receiving 3 core 95 Sq.mm , 11 KV HT Cable, provision for mounting 1 No. HT TOD meter, Test terminal blocks, necessary control cabling etc. with TOD meter). NOTE: Rate quoted is inclusive of excavation & earh work and cost of suitable foundation recommonded by the manufacturer
Cutting bituminous road/ PCC path way/or any other indicated direction , not exceeding to a width of 0.5 mtr and not exceeding to a depth of 0.5 mtr, laying pipe for UG Cable protection and refilling with the excavated material, watering and well ramming in layers and finishing with 1:3:6 PCC up to a thickness of 100 mm, removing the surplus material away from the site, all as specified and directed by the Engr-in-charge.
Supply,install,test and commision LT Panel,indoor type, powder coated , dust and vermin and weather proof outdoor, Cubicle type, outer shell made out of 2.00 mm thick CRCA Sheet & MS angle iron section of 50X50X6 mm frame , factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides having chromium plated 19 mm dia fancy keys, louvers & air vent gasket for natuaral flow of air. Suiable gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCB's/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Location:- (Main LT Panel board).
Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 1000 Amps for phases and 500 Amps for Neutral. Incoming:- (a) MCCB 500 Amp FP 50 KA - 01 (Incoming) Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. (c) CT's - 500/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB 315 Amp FP 36 KA - 01 (Outgoing) (b) MCCB 125 Amp FP 36 KA - 01 (Outgoing) (c) MCCB 100 Amp FP 36 KA - 01 (Outgoing)
-Ditto- all as per item no.18.36 above but with the following fixtures:- ( Standby Supply Panel) Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 500 Amps for phases and 250 Amps for Neutral. Incoming:- (a) Change over switch, 415 V, four pole 125 Amp. - 01 (Incoming) (b) MCCB 125 Amp FP 36 KA - 01 (Incoming) Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. (c) CT's -200/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB 100 Amp FP 25 KA - 01 (Outgoing) (b) MCCB 63 Amp FP 25 KA - 01 (Outgoing)
-Ditto- all as per item no.18.36 above but with the following fixtures:- ( Pump House) Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 250 Amps for phases . Incoming:- (a) MCCB 63 Amp FP 36 KA - 01 (Incoming) Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. (c) CT's -200/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB 36 Amp FP 25 KA - 01 (Outgoing) (b) MCCB 36 Amp FP 25 KA - 01 (Outgoing)
Supply and spread LT Rubber mat of 1 mtr x 2 mtr x 19 mm
Supply and fix cable route indicator HT/LT embedded in PCC and marking whether HT/LT cable with embossed arrow mark towards cable direction.
Supply and fix 70W LED path way light fitting with IP65 alluminum diacast housing, inbuilt drive and all acessories etc. . complete all as specified. Make: Havells cat part No RUBYMAXIPT70WLED757PSYMTOPC or equivalent specification in Philips/Wipro.
Supply and fix bollard light fitting , 8w retrofit made out of extruded alluminum and poly carbonate diffuser etc. . complete all as specified. Make: Havells Model 3.5MPOLE HSN7308 or equvalent in Philips/ Wipro NOTE: Rate quoted is inclusive of excavation & earh work and cost of suitable foundation recommonded by the manufacturer
Supply and fix Aesthetically designed decorative hot dipped 3.5m galvanized mild steel step pole with grey powder finish. Compatible for all Havells post top range, window plasma cut & duly champhered opening window of 300 x 110mm for terminal connections & mounting accessories. Window cover if fitted with allen screws to the pole Make:- Havells/ Wipro/ Bajaj NOTE: Rate quoted is inclusive of excavation & earh work and cost of suitable foundation recommonded by the manufacturer
Supply and install solar street light post top stand alone fitting with 2500m LED luminaire integrated mono silicon PV cells, Life PO4 100Ah 12.8V battery, alluminium alloy powder painted body, necessary fixing arrangement including excavation and PCC in foundation etc all complete as specified Make : Philips/ Havells/ Wipro
Supply & Fix LED flood light fitting 110W with suitable fixing arrangement made out of GI pipe of size not less than 40mm dia
Supply & Fix LED Flame proof type, Exhaust fan 12" (300mm) sweep, Copper wound suitable to work on single phase supply, Ac 230V, 50Hz, 3 Blades including shutter/ louver connecting complet all as specified & as directed. Make: Sudhir or equivalent in list of approved make enclosed
FIRE FIGHTING: Electrically controle panel board of cubical construction ,wall mounting type ,fabricated out of 3.15 mm thick CRCA sheet factory made , certified with hinged lockable doors,inter connection, having switch gears and accessories mounting and internal wiring ,earth terminal ,numbering etc ,complete in all respect ,suitable for operation on415V,3 Phase ,50hz AC Supply comprising the following :- (a) MCCB 150 Amps, 4P -01no.(in comer) (b) MCCB 100 Amps, TP, MCCB -01 no. (c ) MCCB 63 Amps, TP, MCCB -01 no. (d) Digital panel multi function meter -01 Nos. (e) Starter with auto manual controle -02 Nos (Exclusively for jockey pump and terrace pump only . (f) Set of 3 phase indicating lamp -01 set
NOTE: Automatic operation of main pump set (01 No) other than jocky pump set within 10 seconds while jocky pump is running to meet the requird pressure in main line .if the main pump set fails to start within 10 seconds , run procedure /programe for automatic start operation of engine driven pump sets to meer the requiredconstant pressure from varying low pressure in main line within 10 seconds .(f) Digital /analog display of parameters /status of engine as under:- (i) Low fuel(the display should match the corresponding fuel capacity of engine driven pump set in item No 25 .(ii) Over heat (iii)Low oil pressure etc and all standard features as per manufactures guide line.Note: -(a)The minimum pressure to be maintained in line is 4.5kg per CM².Cost of all accssories to operate the pumps in automatic /manual operation and the sequence of operation is deemed to be incuded in unit rate. The control panel shall meet the conditions of main pump, jockey pump and engine driven pumps here in above
Supply, connect, joint and lay MS flanged pipe heavy duty ISI marked with all fittings of size 100 mm dia with flanged ends and including flanges, leather gaskets, heavy duty bolts, nuts, washers etc, laid in trenches,floors, fixed on walls/floors/roof ete including fixing with clamps on wall for the wet riser including painting with approved synthetic enamel paint all as specified and directed by Engr-in-charge.
-Ditto- all as item No.14.44 above but of size 80 mm and directed by Engr-in-charge.
Supply erection testing and commissioning of Gun metal Air release valve 50mm dia complete.
Supply, installation, testing and commissioning of Analog addressable type active Loop Repeater (Loop power/External power) fire terminal with inbuilt turbo isolator, Backlit LCD display 6 X 40 characters display, having controls for reset, mute, accept, silence alarms and self test with programmable free keys and duly approved by EN54/LPCB/VDS/FM Make:- SIEMENS/NOTIFIER/BOSCH
Supply, installation testing and commissioning of XLPE insulated electric cable with copper coductor of size 1.5 sq.mm, 2 core suitable for working pressure 1100 Volts to IS:7098 and drawn into PVC coduit pipe 20 mm. complete all as specified and directed.
S&F wall mounted LED emergency Exit signage luminaire Light up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours (Cat No LSSR5W Make CG or equivalent to Bajaj/havells.
S & F fire extinguisher dry chemical powder (ABC) type (IS:15683) of capacity 4 Kg complete with installation brackets all as directed.
S & F fire extinguisher CO2 (light weight squeeze grip type) (IS:15683) of capacity 4.5 Kg complete with installation brackets all as directed.
M & L Valve chamber of internal size 1.20 m X 1.20 m X 1.20 m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation , brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to both internal and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The estimated cost includes all earthwork and connected items.
Supply,install,test and commision LT feeder pillar box type panel,outdoor type, powder coated , dust and vermin and weather proof outdoor, Cubicle type, outer shell made out of 3.15 mm thick CRCA Sheet & MS angle iron section of 50X50X6 mm frame , factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides having chromium plated 19 mm dia fancy keys, louvers & air vent gasket for natuaral flow of air. Suiable gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCB's/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge.
Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 100 Amps for Neutral. Incoming:- (a) MCCB 4 pole, 415 Volts, 63 Amps, breaking capacity 18 KA- 01 No. Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. (c) CT's -63/5A, CL-1, 15 VA - 1 set Outgoing:- (a) MCB TPN 32 Amps "D" curve 10 KA - 1 No. (b) Direct on line starter suitable for 7.5 HP motor- 01 No. (c) Single phase preventer - 01 No. (d) Contactor suitable for 7.5 HP motor - 01 No. (e) Provn for pressure switch -01 No
NOTES FOR LIFT: (i) Double button with 7 segmental display at all floors. (ii) Car opening panel with micro stroke push button with 7 segment digital car position indicator, car direction indicator (iii) Fireman's which provided at main lobby. (iv) Battery operated alarm bell and emergency lift with battery. (v) Voice Syntesizer (vi) Car Chime (vii) Provision of cross flow rectangular (low noise/mild air flow) fan-01 of approved make. (viii) S&F Decorative spot light (ix) Provn of emergency intercom system (car machine room-control system) (x) Oveload function, constant indication/buzzer. (xi) 5/15 A power socket & light point at every floor level in the hoist way. (xii) MS Ladder(xiii) 3 Phase power supply & earthing from machine room to all equipment. (xiv) Muti beam full length infrared door sensor (minimum of 32) (xv) Emegency landing device ELD (ARD) (xvi) Extra cores in travelling cable for customer smoke detectors. (xvii) Back ground music speakers.
DG SET: Supply and install Static silent Disel Engine with accoustic enclosure, capable of delivering 50 Kw (63 KVA), water cooled, 415 volts (AC three phase, 4 wire system of supply) , frequency 50 Hz, at power factor 0.80 minimum. The DG set shall consists of a diesel engine coupled to a matching the alternator through flexible coupling and mounted on a common based frame and complete with control panel standardized by the manufacturer, fuel tank with mounting arrangements and with standard fuel pipes for inlet, outlet and return inlet oil arrangements, exhaust pipe, silencer and asbestrose rope protection complete and shall be suitable for conditions prevailed at Kochi. (Designed capacity of Diesel engine and alternator shall be worked out by considering all derating factors prevailed at the area to be installed) The foundation of Gen Set shall be as specified by the manufacturer and shall be mounted on a suitable Channel frame structure with anti-vibration pads and including all technical features to comply with latest CPCB guidelines and comprising of followings:-
(i) DIESEL ENGINE (Prime Mover): Diesel Engine 1500 RPM, direct injection, four cylinders, four stroke, confirming to ISO3046/BS5514, water cooled, natuarally turbo charged, capable of giving adequate BHP to drive alternator capable of delivering 50Kw(63 KVA) at outdoor atmospheric conditions at Fort Kochi(Considering all derating factors prevailed in the area). Batteries 12/24 Volts and desired ampere hours (as per manufacturers recommendations), electric battery start, complete with fly wheel and all standard fittings and fixtures as per manufacturer and including suitable panel with techo meter, lub oil temperature, pressure gauge and frequency meters. The engine shall have self starter, dynamo, FIP, oil pump, fuel electric control panel with mechanical governor (ECPG) and Engine protection system (Shut down, High water temperature, low lub oil, oil pressure, over speed etc. , recommented capacity of fuel tank and first filling of fuel and lub oil and other consumables etc. (ii) ALTERNATOR: Brushless AC alternator, 3 phase, 415 Volts, 4 wire rated for output of 50 Kw (63 KVA) minimum power factort 0.80, 1500 RPM, IP 23 ptotection class enclosure, insulation class 'H', salient pole, revolving field, single bearing, automatic voltage regulator coupled through flexible coupling with and match the above engine. (iii) BASE PLATE:- Made of structural steel as per manufacturers recommended design/specifications. (iv) ACOUSTIC ENCLOSURE:- Sheet metal fabricated canopy type, silent enclosure, manufactured on CNC machines as per CPCB norms and shall be powder coated. The enclosure shall be designed for reducing the sound level to 75 DB at a distance of 1 mtr at 75% load under field condition and 70DB at 3 M from Gen Set when DG set is working at full load along with testing performance, labeling certification etc. as laid down in GSR No. 371(E) dt 17 May 2002. (i) Foundation/Plinth/Base shall be provided as per manufacturers recommendations, however minimum 0.50 M space should be available all around the set and height of plinth shall not be less than 0.50 M.
(ii) Standard Diesel Engine tank of adequate capacity for running the Gen Set continuously for 12 hours including standard pvc pipes from tank to FIP, overflow pipe from FIP to tank. (v) MISCELLANEOUS:- Tool kit, Operation and maintenance catalogue, spare parts list, overhauling manuals, guarantee cards, test certificate of Engine and alternator etc. shall be provided as per manufacturer standard practice. (vi) AMF CONTROL PANEL:- factory made cubicle type floor mounted LT Panel board, indoor type made out of MS angle not less than 40x40x50 mmand 2 mm thick MS CRCA Sheet, front opening type, protection class IP-54, duly powder coated, copper bus bar with coloured PVC sleeves and of suitable rating for four poles mounted on suitable porcelain insulators at recommended intervals, with all standard switch gear and protection, internal wiring with adequate size and rating PVC insulated multistranded copper conductor cables etc. and also consisting the following: Copper busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 300 Amps for phases and 150 Amps for Neutral. Incoming:- (a) MCCB 4 pole,415 Volts, 100 Amps, breaking capacity 25 KA- 02 Nos. Metering Unit and other accessories :- (a) R Y B Indications (LED Type) - 1 set. (b) Indicator for on/off GEN/MAIN supply- 2 Nos. (c) Digital Multi function meter - 01 No. ( d) CT's - 100/5A, CL-1,15 VA - 1 set (e) 3 pole line Contactorwith AC coil, 100 Amps- 2 Nos. (f) All standard relays, circuits and protection required for automatic operation of DG set. (g) Charger for recharging the battery and armoured copper cable of suitable rating from battery charger to the engine- one job. Outgoing:- (a) MCCB 4 pole,415 Volts, 100 Amps, breaking capacity 25 KA- 02 Nos.(one spare)
M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.5 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 40mm dia light grade GI protection pipe for earth lead etc., complete.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
AVIATION OBSTRUCTION LIGHTS: Supply and fix aviation obstruction light integral aviation light comprising of aluminmium housing with poly carbonate enclosure 302 nod LED . Make Bajaj Cat No. BGAV 302 LED/equivalent.
Supply,fix including testing comissioning XLPE insulated screened PVC bedded galvanised steel strip or wire armoured power cable (Heavy duty) 1100 V grade with stranded aluminium conductor of size 2 core 6 Sqmm on poles /walls as cable for aviation obstruction light all as specified and directed.
S&F timer switch and MCB SPN, 230 V, 10 Amp enclosed in a metal enclosure.
SUMMER APPLIANCE: S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of +2.5% and of capacity 3KVA
Supply & Fix refrigerator, electric driven single phase capacity more than 360 litres BEE 5 Star rated
SOLAR HOT WATER SYSTEM: Supply and lay 3 layer (Inner antimicrobial) outer UV stabilized ISI marked, IS15801, PPR pipe SDR 7.4 (PN-16) and PPR plain fittings in trench/ wall/ ceiling or laying in floors completeof size 20mm dia including fittings
Supply and fix PPR gate valve (Brass insert) of 20mm dia
S&F Hot water pipe of size 20mm duly insulated with glass wool and alluminium clading
S&F Hot water pipe of size 25mm duly insulated with glass wool and alluminium clading
TREATED WATER SUPPLY: Supply and lay 3 layer (Inner antimicrobial) outer UV stabilized ISI marked, IS15801, PPR pipe SDR 7.4 (PN-16) and PPR plain fittings in trench/ wall/ ceiling or laying in floors completeof including fittings (a) size 20mm dia
(b) Size 25mm
© Size 40mm
Supply and fix PPR gate valve (Brass insert) of 20mm bore
Supply and fix PPR gate valve (Brass insert) of 25mm bore
Supply and fix PPR gate valve (Brass insert) of 40mm bore
Supply and fix water impact Garden Srinkler made of brass having 20mm dia
SEWAGE TREATMENT PLANT: Designing (hydraulically, structurally & aesthetically), providing, constructing, hydraulic testing, commissioning and giving satisfactory trials of STP of capacity not less than 08KLD consisting of Inlet chamber, Fine bar Screen chamber(manual) with steel screen, Oil & Grease Remover, Grit separator, Equalization Tank( 2 Tanks of 50% Capacity each), Air Grid for Equalization Tanks, Feed Pumps(2 No), Moving Bed Bio Reactor(s) with plastic media (of appropriate density, size and quantity to keep very high MLSS > 15,000 mg/lit), Air Blowers for MBBR, Tube Settler assembly, Sludge Drying Bed of appropriate size, Chlorine Dozing System, Chlorine contact tank, Foundation for all E/M equipments, Associated piping work with required valves, gates, drains, pathways, Electrical control Panel with interconnecting cable, spare parts for 2 years of operation, etc. complete as turnkey job with all involved civil, electrical, digital and mechanical works as per detailed specifications for civil, electrical and mechanical components, Including tertiary treatment consist of Filter Feed Tank, Filter Feed Pumps, Dual Media Filter, Activated Carbon Filter, Treated water Tank etc all. (a) Site survey of total area (b) Collection of present population data, arrive at futurisitic population and design the sewerage line network for complete area of 18 Acre and sewage treatment plant (From first manhole to last pertaining point of treated water) (c) Collection of existing water supply data and sewage network data. (d) Qualitative and quantitive assessment of waste water. (e) Design of STP of on the principle of aerobic attached growth non clogging randomly Moving bed Bio- Reactor (MBBR) including mechanical and civil works for STP of approximate capacity 200Cum/ day as per the OEM specification to achive desired treated sewage parameters as given in Appx 'B' or parameters as per NGT principle bench New Delhi is supirior (Refer E-in-C's branch letter No 86435/Mis/policy/54/E4 (U3) dtd 24/04/2020
(f) Design of STP shall comply guideleine issued by Kerala pollution Control Board including management of soild waste/ sludge generated out of treatment process and also guideline issued by NGT. (g) Design of STP shall include complete Arch design, Structural Design including treated water collection sump with pump house, Mechanical control & circuiting instrumenation (MEP design) etc. Schematic treatment process flow diagram with drawings will be enclosed as per Kerala State Pollution Control Board. (h) all equipment and civil works will be designed considering atmosphere conditions prevailing at Kochi. (j) Before finalizing the report, a presentation shall be made by the firm in the presence of officials from both Coast Guard and MES at Kochi and CE office to finalize the details. (k) Sunbmission of interim report incl design calculations & Drawings (l) Submission of final report with all parameters, calculation of scheme, schematic layout of prop. system Arch, Structural, mechanical and Electrical drawings dully vetted by IIT/ NIT. Desired quality effluent of non portable reuses is given as per E-in-C’s Branch letter No. 86435/Misc/E4(U3) dated 19 May 2017 or parameters as per NGT principle bench New Delhi judgement as delivered on 30 April 2020 on OA No. 1069/2018, which ever is superior (please refer E-in-C’s Branch letter No. 86435/Misc/policy/54/E4 (U3) dated 24 Apr 2020) Scope of Work (as per Design)
PILE FOUNDATION: Boring of cast in situ pile of 900 mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place out side MD land all as specified and directed.
Boring of cast in situ pile of 700 mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place out side MD land all as specified and directed.
Boring of cast in situ pile of 600 mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place out side MD land all as specified and directed.
Boring of cast in situ pile of 500 mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place out side MD land all as specified and directed.
Boring of cast in situ pile of 500 mm dia under reamed pile to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place out side MD land all as specified and directed.
Reinforced cement concrete of grade M-30 design mix (RMC) as per IS-456 with using 20 mm graded stone aggregate in cast in situ DMC bored pile of any length/any sections complete all as specified and as shown on drg as in bored pile including non destructive integrity test on all pile as per IS-2911 part-IV. (Note: The unit rate quoted under this item is deemed to be inclusive of charges for non destructive integrity test)
Reinforced cement concrete of grade M-30 design mix (RMC) as per IS-456 with using 20 mm graded stone aggregate in cast in situ Under reamed bored pile of any length/any sections complete all as specified and as shown on drg as in bored pile including non destructive integrity test on all pile as per IS-2911 part-IV. (Note: The unit rate quoted under this item is deemed to be inclusive of charges for non destructive integrity test)
Reinforced cement concrete of grade M-30 design mix (RMC) as per IS-456 with using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg (Note:- Reinforcement will be measured and paid for seperately under relavent items of this schedule)
Providing TMT bars (CRS/HCR/CRM) in reinforcement 10 mm dia and over for bored piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCR/CRM) in reinforcement 10 mm dia and over for pile caps/ grade beams all as shown on drgs including cut to length, bend to required shape, cranking/ hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCR/CRM) in reinforcement 5 mm dia and over up to and including 10mm dia conforming to IS-1786 as Helical/stirrups for piles cut to length, bent to shape required, and binding with 0.9mm dia MS wire annealed or welding
Providing TMT bars (CRS/HCR/CRM) in reinforcement 5 mm dia and over up to and including 10mm dia conforming to IS-1786 as stirrups for pile caps/ grade beams cut to length, bent to shape required, and binding with mild steel wire (annealed) not less than 0.9mm dia or welding
PCC (1:4:8) type D2 using 40 mm graded stone aggregate for concrete layer below pile capsfoundation complete all as specified and directed.
Formwork to sides of pile caps/ grade beams rough finished surface of concrete flat. All as specified and as directed.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M deep or area not exceeding 10 sqm on plan and getting out in soft/loose soil for pile caps
Returning filling in and ramming in layers around pile cap , plinth beams, tie beams etc using excavated soil including spreading levelling and well ramming in layers not exc 25 cm thick all as specified and as directed.
Removal excavated soil to distance not exceeding 50M and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and as directed.
Testing of piles (Initial Load test )for compression load, lateral load & uplift load) all as per IS 2911 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 600mm dia cast in situ pile. Note: Rate inclusive for casting of 04 piles for above test. However concrete, steel and boring shall be measured under respective items
Testing of piles (Routine Load test) all as per IS for 900 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
Testing of piles (Routine Load test) all as per IS for 700 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
Testing of piles (Routine Load test) all as per IS for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
Testing of piles (Routine Load test) all as per IS for 500 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L barricade railing, stainless steel pipe of any size as embedding in concrete and welding etc confirming to grade 316L complete all as specified & directed
M & L for provision of Mild steel Ornamental Gate with pillars, facade including finishes complete all as specified, shown on drawing and as directed by Engr-in-charge
Providing and fixing in positionto lines and levels 15 tonne capacity cast steel bollard single horn (single lobe) type,as shown in the drawing including supplying and fixing in position with all fixtures such as Hot Dip galvanized M24 anchor bolts,nuts,gruting inside with cement concrete of M40 grade excluding reinforcement and including fixing the anchor bolts with template arrangements in the proper algnment as shown in the drawing,including paintig the bollards and all steel works with two coats of anticorrosive epoxy paint over a coat of epoxy primer etc.Complete as per drawings,detailed specified and directed.
Provision and fixing in position Flat top Arch type rubber fender 800mm H and 2500mm long of approved quality having energy absorption of 22 Ton-m per metre at max 52.5% deflection and max reaction force 66.3 T per metre with 30mm thick UHMW-PE face pads including bolts,nuts and washers of stainless steel SUS 316 grade,all fixtures,rigidly in correct alignment and position at seaside of wall as per drawings,handling ,transportation,third party inspection,materials,labour,staging,tools,equipmentplants,machinaries,etc complete as per drawings all as specifiied and as directed
S&F Building Name boards made of 3mm thick Aluminium composite panel (ACP) of 1st quality and any colour of size 195cm x 30cm, fixed on walls/ any position and fixing 3D capital letters over ACP Board " COAST GUARD OFFICER'S MESS" of size 25cm (Height) x 20cm (width) x 4cm (Thickness) made of 2mm thick Acrylic sheet and face of letter shall be covered with 2mm thick Stainless steel of grade 302 and letters illuminated by LED peanut bulb (Samsung/ Osram/ L&T) including necessary electrical connection from nearest building distribution board with switch control operations complete all as specified & directed.
Mecone Construction Contractors
Kurian And Varghese
Agarwal Jagdish Construction Company Pvt. Ltd.
RDS PROJECT LTD
SHAIJAL T M
KCP INFRA LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid