| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹88.5 LAccepted-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹89.9 L+₹1.4 L (1.56%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹93.3 L+₹4.8 L (5.38%)Rejected-Finance RSD STREET HALL BAZAR AMRITSAR 143001 PUNJAB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹98.9 L+₹10.3 L (11.7%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹99.4 L+₹10.9 L (12.3%)Rejected-Finance PHAYANG GOMPA COMPLEX AGLING ROAD SKALZANGLING LEH LADAKH J K 194101 | LEH | LEH | LADAKH | 194101 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
24 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col S S Babu
Headquarters 138 Works Engineers Pin-914138 C/o 56 APO
PROVN OF EXTERNAL ELECTRIFICATION ALONG WITH ALLIED INFRA FOR SATA REGT UNDER GE 865 EWS
2021_MES_444358_1
138WE/L-24/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
GE 865 EWS
₹2.1 L
Yes
22 Jul 2021
20 May 2021
26 Jun 2021
20 May 2021
24 Jun 2021
10 Jun 2021
60 days
Amount
Supply , Installation, Testing and commissioning of out door type transformer with standard fitting and accessories. Step down copper wound 11 KV on HT side and 433 volts on LT side at no load 3 phase 4 wire system 50 C/S AC supply of 250 KVA oil immersed laminated iron core naturally cooled with external tubes, delta connected on HT side and star connected on LT side corresponding to vector group DY-II with neutral brought out separately for earthing including off road change tap arrangement up to +7.5% in steps of +2.5% each complete with first filling of transformer oil up to appropriate level and LT side suitable for connection with trunk bus bar including RCC foundation for TFR at suitable height and cattle fencing of 1.5 m height around the transformer confirming with IS 2026, complete all as specified and as directed.
Steel tubular swaged poles complete with base plate welded with pole, finial taper plug, bolt , nut and screws as specified type 410 SP-55 (11m long ) including one coat of red oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30 cm wide strips (total 05 Nos ) with yellow and black paint alternatively on external surface above PCC benching and painting with bituminous paint internally including writing the pole number in white letters on black background complete and externally for portion embeded in PCC complete all as specified and as directed. Note:- Excavation, Earth work and PCC in foundation of poles, coping etc shall be measured and paid under respective items.
Material and Labour for Cross arms, bracings, supports, clamps and back plates fabricated from structrual steel sections including nut, bolts, washers, welding, bending cold or hot. Drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
Supply and Fixing Lightning arresters explusion type suitable for 11 KV complete with all fittings, transmission class, discharge capacity of 65 KA complete all as specified and as directed.
Supply, Installation Testing and Commissioning of dropout fuse unit complete set suitable for 11 KV HT outdoor and dropout type of capacity 200 Amps including jumper connections with copper flexible designed jumper complete all as specified and as directed.
Supply, Installation Testing and Commissioning of 11 KV outdoor type gang operated air break switch vertical mounting complete with GI operating rod of suitable length for operating mechanism worked from ground level complete in OFF and ON position for current rating up to 200 Amp complete all as specified and as directed.
Supply and Installation Overhead aluminium conductor, steel reinforced, including making connections and fixing on poles with all necessary arrangements complete all as specified and as directed. Note:- Weight of ACSR or all aluminium conductors drawn for overhead lines is to be determined by measuring taut horizontal distance between centres of two adjcent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers etc.
Material and Labour for installation of Cradles, Hexagonal/ Rectangular, fabricated with galvanised steel wire 4 mm dia complete all as specified and as directed.
Supply and erection of Steel tubular swaged poles complete with cast iron base plate welded with pole, finial taper plug, bolt , nut and screws as specified type 410 SP-31 (9.0 m long ) including one coat of red oxide zinc chrome primer an two coats of aluminium paint on surfaces exposed to view and making 30 cm wide strips (total 05 Nos ) with yellow and black paint alternatively on external surface aboce PCC benching and painting with bituminous paint internally including writing the pole number in white letters on black background complete and externally for portion embeded in PCC complete all as specified and as directed. Note:- Excavation, Earth work and PCC in foundation of poles, coping etc shall be measured and paid under respective items.
Supply and Laying XLPE Insulated, Screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables, heavy duty with aluminium conductor, 11000 Volts (Earthed) grade cross sectional area 95 Sqmm 3 Core complete all as specified and as directed.
Material and Labour for cable Jointing Kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed.
Supply and Laying in trenches or passing through pipe or fixed on surface XLPE insulated, armoured, heavy duty electric cable 400 Sqmm 3.5 Core with aluminium conductor 1100 volts grade complete all as specified and as directed.
Supply and Laying in trenches or passing through pipe or fixed on surface XLPE insulated, armoured, heavy duty electric cable 16 Sqmm 4.0 Core with aluminium conductor 1100 volts grade complete all as specified and as directed.
Supply and Laying in trenches or passing through pipe or fixed on surface XLPE insulated, armoured, heavy duty electric cable 10 Sqmm 2.0 Core with aluminium conductor 1100 volts grade complete all as specified and as directed.
Excavation in trenches n. exc 1.5m wide and n. exc 1.5 m in depth for foundation, laying of pipes, cables etc or for manholes pier holes, poles not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and as directed .
Returning filling in soil including spreading, levelling watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Material and Labour for cement concrete 1:3:6, type C-2(using 40 mm graded crushed stone aggregates) for foundation of poles/ stay including form work etc complete all as specified and as directed.
Material and Labour for cement concrete 1:3:6, type C-1 (using 20 mm graded crushed stone aggregates) as in coping of poles studs including form work etc complete all as specified and as directed.
Removing excavated soil to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point including spreading and levelling complete all as specified and as directed .
Supplying , Spreading and levelling sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying complete all as specified in clause 19.75 of SSR Part -I and as directed.
Supply and laying Unreinforced precast concrete cable cover LV type-I, flat size 250 mm x 150 mm x 40 mm complete all as specified and as directed .
Supply and laying Unreinforced precast concrete cable cover HV type-I, flat size 300 mm x 180 mm x 40 mm complete all as specified and as directed .
Suplying and laying GI pipe light grade for cable protection in road crossing of size 80 mm dia complete all as specified and as directed .
Suplying and laying GI pipe light grade for cable protection in road crossing of size 40 mm dia complete all as specified and as directed .
Material and labour for earthing complete with galvanized Iron plate of size 600x600x6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised strip 32x6mm by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.0 kg/Sqm) with cast iron frame, funnel, with wire mesh, 20mm bore light grade GI watering pipe, lugs, 15mm bore light grade GI protection pipe, test point etc complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 m GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 m copper strip earth lead. (iii) Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.
Material and labour for stay assembly using stay rod 20 mm dia complete with accessories as shown in Electric plate No. 1 of SSR 2009 Part-I including galvanised steel wire standed of size 7/4 mm complete all as specified and as directed .
Supply and fixing LED street light fitting 45 watt, having pressure die cast housing with IP 66 efficient, protection with heat resistant toughned glass with individual LED lenses complete including making connections with street light box using PVC insulated and sheathed single core multi stranded copper conductor cable of size 1.5 Sqmm complete all as specified and as directed .
GI Bracket made out of 50 mm dia medium grade pipe 1.2 m length to shape for fixing on pole and suitable for 45 watt street light with 02 Nos clamps of flat iron (40 mm x4 mm ) nuts, bolts and washers including painting with two coats of aluminium paint over a coat of primer complete all as specified and as directed.
Supply and fixing FRP Junction box, light weight low corrossive suitable for pole mounting including MCB SP 6 Amps, box size 250 mm x 200 mm x 100 mm including necessary connection for loop in and loop out cable connector and suitable size for cable glands complete all as specified and as directed.
M/S MALIK CHAND SIRI RAM
Intrernational Engineers
R B TRADERS
betong construction company
Rajindera Enterprises
KAMLA CONSTRUCTION COMPANY
M/S R P SINGH AND COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .