Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical 685 G F PANA SAKTAN NEAR DADA BHAIYA MANDIR BAWANA DELHI 110039 | DELHI | BAWANA | DELHI | 110039 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical CJSF ROAD GALI NO 12 NEAR SHRI RAM GARDEN VIKAS NAGAR PANIPAT 132103 HARYANA | PANIPAT | PANIPAT | HARYANA | 132103 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical VPO BARHI DISTT SONEPAT 131101 | BARHI | SONIPAT | HARYANA | 131101 | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical GROUND FLOOR 353 RUPANA PANA RATHDHANA NEAR SHIV MANDIR RATHDHANA SONIPA HARYANA | AMBALA | HARYANA | 133001 | Admitted-Fee/PreQual/Technical |
Tender Value
₹12.0 L
EMD Value
₹23,920
Closing Date
24 Nov 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DEVINDER KUMAR KAUSHIK
Electrical Rohtak
A/Mtc. of duct-able Air Conditioning System in HSVP office building sec-3, Rohtak for operation and maintenance for the year 2025-2026.
2025_HBC_482568_1
2025D9FE3113 9CA0 4649 8D27 A67755D65805247HSV
Open Tender
Electrical Works
Works
365 days
Rohtak
2 documents required · 2 mandatory
₹500
₹23,920
Yes
27 Nov 2025
11 Nov 2025
25 Nov 2025
11 Nov 2025
24 Nov 2025
11 Nov 2025
[23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA
[23.22.1.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.7. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 400 Amp, 50 KA
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE
Overall maintenance of split type ceiling suspended duct able air conditioners including Periodical servicing of indoor and outdoor units, repair of indoor and outdoor units, refilling of refrigerant as required, providing thermal insulation on copper pipes, replacement of drain pipe, repair of defective ID/OD units including replacement of defective compressor, exhaust motors, I/D unit Blower fans, including electrical wiring, connection plates, PCB, contactor, remote, TandP required, ladder, safety equipments required with complete materialand labour to make the A.C. system always in running condition complete in all respect upto the entire satisfaction of Engineer-in-charge of work. 11TR Machine (Make Voltas) (Excluding GST)
Overall maintenance of split type ceiling suspended duct able air conditioners including Periodical servicing of indoor and outdoor units, repair of indoor and outdoor units, refilling of refrigerant as required, providing thermal insulation on copper pipes, replacement of drain pipe, repair of defective ID/OD units including replacement of defective compressor, exhaust motors, I/D unit Blower fans, including electrical wiring, connection plates, PCB, contactor, remote, TandP required, ladder, safety equipments required with complete materialand labour to make the A.C. system always in running condition complete in all respect upto the entire satisfaction of Engineer-in-charge of work. 5.5TR Machine (Make Voltas) (Exculding GST)
Overall maintenance of split type ceiling suspended duct able air conditioners including Periodical servicing of indoor and outdoor units, repair of indoor and outdoor units, refilling of refrigerant as required, providing thermal insulation on copper pipes, replacement of drain pipe, repair of defective ID/OD units including replacement of defective compressor, exhaust motors, I/D unit Blower fans, including electrical wiring, connection plates, PCB, contactor, remote, TandP required, ladder, safety equipments required with complete materialand labour to make the A.C. system always in running condition complete in all respect upto the entire satisfaction of Engineer-in-charge of work. 8.5 TR Machine (Make Voltas) (Exclulding GST)
S/E of 16 Sqmm x 4-core (Armd.) PVC insulated and sheathed underground cable, loose in existing pipe or trenches 1100 volts core having solid aluminium conductor wires confirming to IS: 694:2010, including making necessary connections complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. Cable Size: Make: Grandlay/Polycab/Havell`s. (Rate Excluding G.S.T.)
stage.html
html • 0.03 MB
tech_bid_open.pdf
cancelled_1.PDF
pdf • 1.25 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.96 MB
BOQ_560565.xls
BOQ • 0.34 MB
OT0129652.pdf
Other Document • 0.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .