| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹4.8 L+₹28,330 (6.31%)Rejected-Finance NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹5.0 L+₹55,420 (12.3%)Rejected-Finance 2 FLAT NO 2 B GEETHANJALI CLASSIK APARTMENT 9TH CROSS KAGGADASAPURA CV RAMAN NAGAR BANGALORE 560 093 | BENGALURU URBAN | KARNATAKA | 560093 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹5.1 L+₹65,000 (14.5%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹5.6 L+₹1.1 L (24.1%)Rejected-Finance 25 A RR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹9,000
Closing Date
29 Oct 2022, 5:00 pmClosed
AGE I AF CHIMNEY HILLS BANGALORE
Asst Garrison Engineer I AF Chimney Hills Chikkbanavara Post Bangalore, PIN- 560 090
COMPREHENSIVE MAINTENANCE OF DG SETS, SERVO VOLTAGE STABILIZER, AMF PANELS, AND CONNECTED MISC ITEMS AT 58 SU AF STN CHIMNEY HILLS
2022_MES_551738_2
8557/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
AGE I AF CHIMNEY HILLS BANGALORE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹300
AGE I AF CHIMNEY HILLS BANGALORE
₹9,000
Yes
12 Jan 2023
8 Oct 2022
31 Oct 2022
8 Oct 2022
29 Oct 2022
15 Oct 2022
8 Oct 2022 - 10 Oct 2022
Amount
Maintenance and servicing of Diesel Generator set of capacity 400 KVA alongwith connected Alternator and Panel Board once in 02 (Two) months installed at Power House by carrying out routine 'A' check of the engine (Except during the month when 'B' check is carried out) complete for smooth functioning all as per manufacturer's instructions and as directed and the quoted rates shall deemed to include the following :- (a) Servicing of DG set with connected Alternator and Panel Board including 'A' check of the Engine shall be carried out once in 2 months, (Except during the month when 'B' check is carried out). Contractor shall carry out periodical inspections during the maintenenace period and shall be responsible for the smooth functioning of the DG set for a period of 60 days from the date of service and shall also attend all the maintenence / breakdown repairs as and when required during the period except in case of major repairs. (b) Repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replacement of minor parts, cleaning & servicing all contact points. (c) Cost of all consumables required during the maintenance period. (d) Cost of all labour for fixing the spares. NOTES :- (i) Spare parts other than mentioned in para (b) above required for replacement during the maintenance period hall be measured & paid separately "UNDER SUPPLY ONLY RATES" (ii) List of checks to be carried out under 'A' check is attached as Appendix 'A' to the Particular specifications.
All as per item No. 1, here in before but 62.5 KVA installed at Pump House,STP,Power House
All as per item No. 1, here in before but 40 KVA installed at Power House,Main Gate
All as per item No. 1, here in before but 30 KVA installed at Power House
All as per item No. 1, here in before but 20 KVA installed near Tower No 10
All as per item No. 1, here in before but 10 KVA installed at Helipad
Maintenance and servicing of Diesel Generator set of capacity 400 KVA alongwith connected Alternator and Panel Board once in every 06 (six) months or 250 hours of running of DG Set whichever is earlier installed at Power House by carrying out routine 'B' check of the engine including items covered in 'A' check complete for smooth functioning all as per manufacturer's instructions and as directed and the quoted rates shall deemed to include the following :- (a) Servicing of DG set with connected Alternator and Panel Board carrying out routine 'B' check of the Engine once in 06 (six) months, including items covered in 'A' check. Contractor shall carry out periodical inspections during the maintenenace period and shall be responsible for the smooth functioning of the DG set for a period of 30 days from the date of service and shall also attend all the maintenence / breakdown repairs as and when required during the period except in case of major repairs. (b) Repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replacement of minor parts, cleaning & servicing all contact points. (c) Cost of all consumables such as diesel/oil filters etc., required during the maintenance period. (d) Cost of all labour for fixing the spares. NOTES :- (i) Engine oil, radiator coolant and spare parts other than mentioned in para (b) above required for replacement during the maintenance period hall be measured & paid separately "UNDER SUPPLY ONLY RATES" (ii) List of checks to be carried out under 'B' check is attached as Appendix 'A' to the Particular specifications.
All as per item No. 7, here in before but 62.5 KVA installed at Pump House,STP,Power House
All as per item No. 7, here in before but 40 KVA installed at Power House,Main gate
All as per item No. 7, here in before but 30 KVA installed at Power House
All as per item No. 7, here in before but 20 KVA installed near Tower No 9
All as per item No. 7, here in before but 10 KVA installed at Helipad
Supply only Engine Oil SAE 15W-40W all as specified and directed by engineer in charge. Make :- VOLVOLINE/IOC/Kirloskar/HP
Supply only radiator coolant allas specified and directed by engineer in charge. Make :- VOLVOLINE/IOC/Kirloskar
Dehydration and Filtering the Servo Stabilizrer cooling oil having the dielectric strength when below 40KV and testing of Stabilizer oil after filtration as per IS-335-1972 and removing the moisture contents in the transformer cores/winding as directed by Engr-in-Charge.
Supply and filling top up Stabilizer cooling and insulating oil,Packed in sealed packed container, conforming to IS 335 in the Stabilizer up to the marked level all as specified and directed by Engr-in-Charge.
Comprehensive maintenance of servo voltage stabilizer of capacity 650 KVA, 3 phase, including spares, lubricants and labour installed at Power House complete all as directed. NOTE: Comprehensive maintenance shall include the following:- (i) Routine maintenance every 2 months. (ii) Replacement of defective PCB, Servo motor, multifunction meter, rubber gaskets, Indicator lamps including the above quoted rates etc .,
All as per item No. 17, here in before but but 400 KVA Capacity.
All as per item No. 17, here in before but but 200 KVA Capacity.
Supply and fix in repairs, Battery 180 AH, 12 volts, suitable for DG sets including battery terminals complete all as specified and directed. Make : Exide/Amaron/Tata
All as per item No. 20, here in before but battery 88 AH, 12 volts Make : Exide/Amaron/Tata
Supply and fix Heavy duty Contactor for AMF Panel 30 KVA DG set ,Maximum optimium current AC3 50 Amps with Integrated auxiliary contacts 2 NO +2 NC,Control voltage 415 V with capacitive switching units all as specified and direcetd by engineer in charge.
Supply and fix Heavy duty Contactor for AMF Panel 20 KVA DG set ,Maximum optimium current AC3 32 Amps with Integrated auxiliary contacts 2 NO +2 NC,Control voltage 415 V With capacitive switching units all as specified and direcetd by engineer in charge.
UNIVERSAL ENGINEERING
Sreyas Enterprises
M/S SRI BALAJI ENTERPRISES
rvelectricals
shakti engineering and electrical works
Lucky Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .